as built document
TRANSCRIPT
As Built Report of Monem Business Center
1
INDOOR REPEATER COVERAGE PROJECT
In association with……………
As Built Report of Monem Business Center
2
C O N T E N T S Welcome 01 Contents 02 Site Details 03 Project Overview 05 Implementation Report 06 Coverage Details 06
Repeater & Yagi Antenna Location 07 Sample Antenna Photo 08
Floor plan with cable routine 09 14TH Floor 10
Trunking Diagram with EiRP 11 14TH Floor 12
Antenna Location 13 14TH Floor 14
VSWR 15
VSWR of Antenna with feeder 16 VSWR Measurement 17 VSWR of Antenna with Trace graphs 18
Empirical Path Loss Calculation 22 As Built Link Budget Table 23 All Antenna Rx Level and Rx Quality Repeater OFF & ON condition 24 Bill of Materials 25 IBS Accessories 26 Mechanical Accessories 27 Walk Test Report 28
14TH Floor 29
As Built Report of Monem Business Center
3
SITE DETAILS
As Built Report of Monem Business Center
4
SITE DETAILS
Site Name Monem Business Center
Implementation Date 22-11-2011
Continent Asia
Country Bangladesh
City Dhaka
Location & Building Address 111, Bir Uttam C.R Dutta Road, (Sonargaon Road), Dhaka-1205.
Contact Person at Monem Business Center
Md. Sayd Monirul Islam Mobile No : +880 1712135609, 01819054575
Contact Person at Robi
Mr. Zaved Parvez Mobile No: 01819210661
Contact Person at Cellcomm
Md. Jahangir Kamal Senior Engineer (RF) Mobile No: 01611198108
Survey Done By Cellcomm Solutions Dhaka Ltd.
As Built Report of Monem Business Center
5
PROJECT OVERVIEW
As Built Report of Monem Business Center
6
IMPLEMENTATION REPORT
As per the survey, we have implemented a solution to provide complete in - building cellular coverage inside the MONEM BUSINESS CENTER building 14th floor. Kindly find enclosed herewith the implemented project report regarding the same. The Repeater installed with around 16 no’s of Indoor antennas. The enclosed document gives details of the distributed antenna system, as built floor plan with cable routing, Trunking diagram, Antenna locations etc. The Repeater installed in the 14TH floor shaft room of the building. The cable used was ½’’ low loss feeder cable. Which runs through cable ducts and supported with flexible pipes, clamps saddles etc. The picture of the Repeater and Yagi antenna location is given below. Coverage Details: As per the implementation, details coverage descriptions are shown below. Antenna 16 Nos Floor 14TH Floor
As Built Report of Monem Business Center
7
Picture: 1 Repeater Location (Inside of the 14TH Floor shaft room)
Picture: 2 Yagi Antenna Location (6TH Floor)
As Built Report of Monem Business Center
8
Antenna Picture
Antenna Picture
As Built Report of Monem Business Center
9
FLOOR PLAN WITH CABLE ROUTING
As Built Report of Monem Business Center
10
As Built Report of Monem Business Center
11
TRUNKING DIAGRAM WITH EiRP
As Built Report of Monem Business Center
12
As Built Report of Monem Business Center
13
ANTENNA LOCATION
As Built Report of Monem Business Center
14
ANTENNA LOCATIONS
ANTENNA REF. NO. ANTENNA LOCATION ANTENNA TYPE
14TH FLOOR F14A1 INFRONT OF THE LIFT AREA CEILING F14A2 INSIDE OF THE OFFICE AREA CEILING F14A3 INSIDE OF THE OFFICE AREA CEILING F14A4 INSIDE OF THE OFFICE AREA CEILING F14A5 INFONT OF THE LIFT AREA CEILING F14A6 INSIDE OF THE OFFICE AREA CEILING F14A7 INSIDE OF THE OFFICE AREA CEILING F14A8 INSIDE OF THE OFFICE AREA PANEL F14A9 INSIDE OF THE OFFICE AREA CEILING F14A10 INSIDE OF THE OFFICE AREA CEILING F14A11 INSIDE OF THE OFFICE AREA CEILING F14A12 INSIDE OF THE OFFICE AREA CEILING F14A13 INSIDE OF THE OFFICE AREA CEILING F14A14 INSIDE OF THE OFFICE AREA CEILING F14A15 INSIDE OF THE OFFICE AREA CEILING F14A16 INSIDE OF THE OFFICE AREA CEILING
As Built Report of Monem Business Center
15
VSWR
As Built Report of Monem Business Center
16
VSWR OF ANTENNAS WITH FEEDER
S/N Antenna Name VSWR(Highest)
14TH FLOOR 1 F14A1 1.04 2 F14A2 1.03 3 F14A3 1.04 4 F14A4 1.04 5 F14A5 1.04 6 F14A6 1.04 7 F14A7 1.04 8 F14A8 1.05 9 F14A9 1.04 10 F14A10 1.18 11 F14A11 1.18 12 F14A12 1.23 13 F14A13 1.19 14 F14A14 1.05 15 F14A15 1.04 16 F14A16 1.05
As Built Report of Monem Business Center
17
VSWR Test Method with Anritsu Site Analyzer Set the measuring frequency band as per the operator allotted frequency and calibrate the Site analyzer with the calibrating unit. Select the mode measure match (SWR) from the menu for taking the VSWR against frequency and connect the feeder cable to the site master and save the trace to the site master with the feeder name or antenna name if the VSWR is with in the limit. (Standard for GSM 900 & 1800MHz the limit is less than 1.4 with antenna & less than 1.2 with load) For taking the VSWR from the menu and save, the trace to the site master with the feeder name or antenna name. For down loading the traces from site analyzer to laptop by using the Bird site analyzer software and take the print out for the hard copy.
As Built Report of Monem Business Center
18
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1M2
VSWRF14A1
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.043 @ 1876.047 MHz M2: 1.013 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1M2
VSWRF14A2
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.03 @ 1799.612 MHz M2: 1.005 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1M2
VSWRF14A3
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.048 @ 1798.395 MHz M2: 1.026 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A4
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.042 @ 1746.999 MHz M2: 1.005 @ 1789.170 MHz
As Built Report of Monem Business Center
19
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1M2
VSWRF14A5
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.049 @ 1802.248 MHz M2: 1.016 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A6
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.048 @ 1742.946 MHz M2: 1.034 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A7
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.048 @ 1744.364 MHz M2: 1.009 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A8
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.051 @ 1746.999 MHz M2: 1.021 @ 1789.170 MHz
As Built Report of Monem Business Center
20
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A9
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.049 @ 1749.535 MHz M2: 1.036 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A10
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.184 @ 1746.999 MHz M2: 1.164 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A11
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.189 @ 1746.999 MHz M2: 1.173 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A12
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.233 @ 1746.999 MHz M2: 1.203 @ 1789.170 MHz
As Built Report of Monem Business Center
21
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A13
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.199 @ 1771.938 MHz M2: 1.166 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A14
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.056 @ 1750.953 MHz M2: 1.011 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A15
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.048 @ 1753.588 MHz M2: 1.01 @ 1789.170 MHz
1.0
1.1
1.2
1.3
1.4
1.5
1725 1750 1775 1800 1825 1850 1875
M1 M2
VSWRF14A16
Std: --- Channel: N/AResolution: 130 CAL:ON(COAX) CW: OFF
VSWR
Frequency (1710.0 - 1880.0 MHz)
M1: 1.055 @ 1746.999 MHz M2: 1.022 @ 1789.170 MHz
As Built Report of Monem Business Center
22
Empirical Path Loss (Indoor)
Loss A (dB) = 32.4 + 20Log (f/GHz) + 10nLog (d/m) + kF + pW
Where, A = path Loss in dB f = frequency in GHz d = distance between transmitter and terminal in meters k = number of floors F = attenuation per floor n = power decay index [ from 2 (for LOS to mobile) to 4
(obstructed) ] p = number of walls W = attenuation per wall
n=2.5 & 3.0 & 3.8
As Built Report of Monem Business Center
23
As Built Report of Monem Business Center
24
MONEM BUSINESS CENTER
Repeater OFF Condition
Repeater ON Condition S/N Floors Antenna
Rx Level Rx Qual Rx Level Rx Qual Remark
A1 -85 5~9 -50 0~4 A2 -88 5~9 -55 0~4 A3 -81 5~9 -56 0~4 A4 -90 5~9 -54 0~4 A5 -88 5~9 -54 0~4 A6 -90 5~9 -55 0~4 A7 -85 5~9 -54 0~4 A8 -87 5~9 -50 0~4 A9 -86 5~9 -48 0~4 A10 -90 5~9 -47 0~4 A11 -85 5~9 -51 0~4 A12 -90 5~9 -50 0~4 A13 -91 5~9 -55 0~4 A14 -89 5~9 -54 0~4 A15 -86 5~9 -57 0~4
1 14TH FLOOR
A16 -90 5~9 -55 0~4
As Built Report of Monem Business Center
25
BILL OF MATERIAL
As Built Report of Monem Business Center
26
IBS ACCESSORIES
S/N Item Description Quantity (Received)
Quantity (Used)
Balance Material
Given to Robi
01 Repeater Multiband Selective 33 dBm 1 No 1 No ---- 02 1/2” Low loss feeder cable 400 Mtrs 330 Mtrs 70 Mtrs 03 N(m) connecters for 1/2”low loss feeder cable 52 Nos 56 Nos ---- 04 Indoor ceiling Antenna 16 Nos 15 Nos 01 No 05 Indoor panel Antenna 01 No 01 No ---- 06 Yagi Antenna 01 No 01 No ---- 07 2- way Power splitter 06 Nos 07 Nos ---- 08 3- way Power splitter 01 Nos 01 Nos ---- 09 7 dB Couplers 03 Nos 03 Nos ---- 10 10 dB Couplers 01 Nos 01 Nos ---- 11 15 dB Couplers 03 Nos 03 Nos ---- 12 0.5M (M-M) Jumper Cable 5 Nos 5 Nos ---- 13 N(M-F) Right Angle Adapters 15 Nos 15 Nos ---- 14 UPS 01 No ---- 01 No
As Built Report of Monem Business Center
27
MECHANICAL ACCESSORIES
S/N Item Description Quantity (Received)
Quantity (Used)
Balance Material Given to
Robi 01 Indoor ceiling Antenna clamp 15 Nos 15 Nos 01 Nos 02 Indoor Panel Antenna clamp 01 Nos ---- 01 Nos 03 2” White Box Chanel 100 Mtrs ---- 100 Mtrs 04 1“ metal saddle 5 Pkts (1 Pkts=100 Nos) 5 Pkts (1
Pkts=100 Nos) ----
05 1“ screws 5 Pkts (1 Pkts=100 Nos) 5 Pkts ---- 06 8mm Royal plug (gutties) 5 Pkts (1 Pkts=100 Nos) 5 Pkts ---- 07 Cable ties 12” 05 Pcs 200 Pcs ---- 08 10mm Royel Bolt 04 Nos 04 Nos ----
As Built Report of Monem Business Center
28
WALK TEST REPORT
As Built Report of Monem Business Center
29
14TH FLOOR
As Built Report of Monem Business Center
30
TEMSTM Investigation 9.0.2 Data Collection