Suspension System ARMSTRONG CEILING

Upload: others

Post on 28-May-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

Suspension SystemA R M S T R O N G C E I L I N G

Page 2: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

Suspension SystemA R M S T R O N G C E I L I N G

Universal Main Runner 24Peakform with Superlock Clip

Cross Tee 24 TL

Universal Main Runner 15Peakform with Superlock Clip

Cross Tee 15 TL

24 mm XL PRELUDE PEAKFORM

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 73 40 42 Main Runner 3600 43BP 73 42 52 P 1200 mm cross tee 1200 35 BP 312022 600 mm cross tee 600 30

24 mm XL PRELUDE 38

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 73 40 32 Main Runner 3600 38BP 31 30 31 1200 mm cross tee 1200 38 BP 31 20 31 600 mm cross tee 600 38

24 mm XL PRELUDE 32

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 73 42 101 Main Runner 3600 32 7.05BP 71 30 62 1200 mm cross tee 1200 27 BP 71 20 11 600 mm cross tee 600 25

23.78

15.34

7.05

PRELUDE 24 - EXPOSED SUSPENSION SYSTEM 24mm (NOMINAL)

SUPRAFINE 15- EXPOSED SUSPENSION SYSTEM 15mm (NOMINAL)

15 mm SUPRAFINE 38

15 mm SUPRAFINE 32

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 73 42 101 Main Runner 3000 38 7.57BP 71 30 62 1200 mm cross tee 1200 38 BP 71 20 11 600 mm cross tee 600 38

BP 75 42 102I Main Runner 3000 32 7.57BP 75 30 102 1200 mm cross tee 1200 32 BP 75 20 11I 600 mm cross tee 600 32

15 mm SUPRAFINE PEAKFORM

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 75 40 42 Main Runner 3600 43 23.71BP 75 30 42 1200 mm cross tee 1200 43 BP 75 20 42 600 mm cross tee 600 43

23.71

14.0

7.57

Page 3: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

Suspension SystemA R M S T R O N G C E I L I N G

Silhouette Main Runner with Black reveal

Silhouette Main Runner with White reveal

Select Main Runner with White reveal

Select Main Runner with Black reveal

Select Cross Tee

SILHOUETTE XL 15mm (NOMINAL) DESIGNER GRIDSilhouette with 6mm reveal is available either in Armstrong Global White or Global White with Black reveal (BI).

SELECT 15mm EXPOSED SUSPENSION SYSTEM 15mm (NOMINAL)

SELECT 15mm with Mitre Cut

eveal)

System load carrying capacity

(mm) kg/m2

45 15.6845 45

eveal)

System load carrying capacity

(mm) kg/m2

38 11.2538 38

15.68

11.25

SILHOUETTE HIGH END (6mm white/black r

Item Nr. Component Dimensions length height (mm) BP 80 40 82/Bl Main Runner 3600 BP 80 30 82/Bl 1200 mm cross tee 1200 BP 80 20 82/Bl 600 mm cross tee 600

SILHOUETTE MID-RANGE (6mm white/black r

Item Nr. Component Dimensions length height (mm) BP 80 42 32/Bl Main Runner 3000 BP 80 30 32/Bl 1200 mm cross tee 1200 BP 80 20 32/Bl 600 mm cross tee 600

15 mm SELECT

Item Nr. Component Dimensions System load length height carrying capacity (mm) (mm) kg/m2

BP 70 42 102 A/BlA Main Runner 3000 32 10.12BP 70 30 102 A/BlA 1200 mm cross tee 1200 32 BP 70 20 102 A/BlA 600 mm cross tee 600 32

7.0

NEW

Page 4: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

Suspension SystemA R M S T R O N G C E I L I N G

ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2

Flat FacedMain Bar

Flat FacedCross Tee Top Hat Main Bar

with joinerTop Hat

Cross Runner

C-SplineRoll-in Clip MR Joiner

600 X 600 mm

1200 X 1200 mm

1500 X 1500 mm

Aluminium Wall Molding

Accessories

Detail Main Bar Cross Tee Cross Tee

Detail Main Bar Cross Runner C-Spline with joiner

Detail Main Bar Cross Runner C-Spline with joiner

Item no Length Dimensions

Detail Roll-in Clip MR Joiner

Item no 4640037S37 4630037S38 4620037S30Height 38 39 38Width 24 24 24Length 3600 1200 600

Item no 4740084S24 4730084M 743054CAHeight 45 45 35Width 32 32 11Length 3600 1200 1200

Item no 4789095S26 4736095M 743654CAHeight 50 50 35Width 32 32 11Length 4500 1500 1500

784005A 3600 15.6 x 9.7 x 9.7 x 15.6 1925HA 3600 25 x 19 784008A 3600 20.5 x 8.2 x 9.5 x 19.1 784009A 3600 20.5 x 9.5 x 9.5 x 19.1

Item no 7515 9329

FLAT FACED

TOP HAT

1800 mm

1200 mm

1500 mm

2100 mm

2400 mm

Detail Main Bar C-Spline Locking Jaw without lock C-Splines Clip

Detail Prelude 38 Prelude 38 Stabiliser Main Beam concealed grid Bar

Detail Prelude 38 Prelude 38 Stabiliser Main Beam concealed grid Bar

Detail Main Bar C-Spline Locking Jaw without lock C-Splines Clip

Detail Main Bar C-Spline Locking Jaw without lock C-Splines Clip

Item no 4740092S34 743494C 743494CT GM1220Height 50 50 50 5Width 32 11 11 20Length 3600 1800 1800 20

Item no 734032 743032 7431Height 38 38 22Width 24 24 22Length 3600 1200 1200

Item no 734032 743632 7436Height 38 38 22Width 24 24 22Length 3600 1500 1500

Item no 4740092S34 747394C 747394CT GM1220Height 50 50 50 5Width 32 11 11 20Length 3600 2100 2100 20

Item no 4740092S34 747094C 747094CT GM1220Height 50 50 35 5Width 32 11 11 20Length 3600 2400 2400 20

SL2 INSTALLATION

K2C2 INSTALLATION

Main BarC-Spline without lock

Locking C-SplinesJaw Clip

Prelude 38Runner /Concealed Grid 8Main

Stabiliser Bar 22

22

Page 5: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

BPGM2010 – Hook ClipConnects 2.68 mm hanger wireto the main runner; recommended for renovation & fast track applications; provides easy adjustment of ceiling height

BPGM2626 - Vertical HangerConnects Anchor Fastener and steel wire.

BPGM 6065 Anchor FastenerUsed to secure the ceilingsuspension hanger wireto the structural soffit/deck

BP 7891 6bd10 – 12 Gauge Soft HangerWire ( 2.68mm, L 1800mm)Used to hang suspended ceilingsfrom structural deck

26 mm

26 mm

25 mm

BERC2 – 50mm Beam EndRetaining Clip – Joins mainbeam or cross tee to wall molding and web of grid with no visible pop rivets■■ BERC2

Seismic Joint Clip CT – Offers afaster, easier and better seismicsolution for Seismic Category D,E and F installations. Armstrongoffers the only StateUniversity of NewYork, University of Buffalo-testedapproach tocreating seismicseparation joints inIBC Category D, E and F installations.■■ SJCG

Seismic Joint Clip – MB – Allows theceiling to be divided at a splice on mainbeam to accommodate the IBC mandate forceiling areas greater than230 m2 to have seismicseparation joints. ES4expansion sleeve is usedto cover 19mm gap.■■ SJMR15

200mm

22mm

22mm

22mm

200mm

19mm

19mm

38mm

200mm

600mm

22mm

22mm10mm 600mm

Suspension SystemA R M S T R O N G C E I L I N G

SUSPENSION HANGERS SEISMIC ACCESSORIES

Page 6: ARMSTRONG CEILING Suspension System · 2015-02-12 · Suspension System ARMSTRONG CEILING ALUMINUM MODULAR SUSPENSION SYSTEM SEMI-CONCEALED SYSTEM SL2/K2C2 Flat Faced Main Bar Flat

PRIN

TLIN

E

It’s simple to install with these easy steps:

Complete

How to install the SeismicSeparation Joint Clip.Step One: Install suspension systemcompletely, in a conventional manner.

Step Two: Decide upon which run(s)of Main Runners to create the seismicseparation. NOTE: the Seismic JointClip allows for cross-tees to movealong the axis of the cross-tees.NOTE: Divide

6mm

1.2m

1.2m

metres.metres,

230 m2 by the lengthof the run of mains in The resultwill be the maximum spacing, infor the separation joint. Round thisresult down to the nearestincrement when mains are installed

on center.

Step Three: Attach two adjacentsides of each section of the dividedceiling to the structure. Where thesesections touch the wall theattachment may be by riveting to thewall molding or by means of theBERC2 clip with a tight screw.Sections that do not touch walls ontwo adjacent sides must be braced tostructure.

Step Four: Cut XL through the enddetails of cross-tees inserted intoMain Runner designated for theSeismic Separation. NOTE: Thisshould be done one intersection at atime or the system willfall apart.

Step Five: Assemble the two sides ofJoint clip into one unit.

Step Six: Snap completed assemblyover the bulb of the Main Runner atthe intersection of the cross-tees.

Step Seven: Insert a long #10screw through slot in clip, into theupper XL clip stake hole. Use verticalstamp mark below the horizontal slotto properly position the screw withinthe clip. Install one screw from eachside of the assembled clip to hold theproper shape. Do not allow screwthreads to strip out the stake hole.

Step 4

Steps 1-3

Step 5

Step 6

Step 7

steel angle

Armstrong World Industries (India) Pvt. Ltd.

Branches:

Representatives:

Boomerang, A-304, Chandivali Farm Road (near Chandivali Studio) Andheri (E), Mumbai - 400 072Tel: 022-3048 0800, Fax: 022-3046 0439 / 2491 3604 | e-mail : [email protected]

Ahmedabad : +91-93272 11062 Bengaluru : +91-80-2657 6367 Chandigarh : +91-172-2633 680Chennai : +91-44-4217 5303

Kochi : +91-96330 09209

Deharadun : +91-84008 84455Bhubaneswar: +91-99370 42387 Coimbatore : +91-87544 57957

Hyderabad : +91-40-3200 9868

Jaipur : +91-87692 17000

Kolkata : +91-33-2401 4755 Lucknow : +91-522-2626 097

Ludhiana : +91-93161 21529

Gurgaon : +91-124-2385 671

Guwahati : +91-96780 69393Indore : +91-73899 42297

Raipur : +91-93259 95527

Pune : +91-93711 56669

Nashik : +91-93259 95556: +91-93756 76005 Vadodara

: +91-97714 15113 Patna: +91-80088 02772Vizag

Hubli : +91-96861 33160Goa : +91-99673 47004