are 309ted feitshans012-1 unit 12 underground storage tanks

11
ARE 309 Ted Feitshans 012-1 Unit 12 Underground Storage Tanks

Upload: tracy-reed

Post on 05-Jan-2016

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-1

Unit 12

Underground Storage Tanks

Page 2: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-2

What is the Problem?

• Safety (explosion hazard)

• Soil contamination

• Groundwater contamination

Page 3: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-3

Hazardous and Solid Waste Amendments of 1984 (HSWA)

• Upgrade existing UST’s

• Standards for new UST’s

• Licensing required

• Maintenance for existing & new

• Philosophy - prevention

Page 4: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-4

Tanks not covered

• Hazardous waste tanks (SWDA)

• Waste water treatment tanks (CWA)

• Hydraulic lift & electrical equipment tanks

• 110 gallons or less

• de minimus concentrations

• Emergency spill and overflow

Page 5: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-5

Excluded from definition

• Farm or residential tanks for motor fuels, of 1,100 gallons or less

• Heating oil tanks for consumption on premises

• Septic tanks

• Pipelines regulated under other law

Page 6: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-6

Excluded from definition

• Surface impoundments, pits, ponds & lagoons

• Storm or waste water collection systems• Flow-through process tanks• Liquid traps associated with gas or oil

production• Basement storage tanks, above floor

Page 7: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-7

Requirements

• Operating• Release detection• Release reporting• Reporting & cleanup of spills and overfills• Closure• Financial responsibility• State programs

Page 8: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-8

Financial responsibility

• Federal & state governments exempt (local government must comply)

• $1.5 - $3 million worth of assurance• May be reduced by coverage under the

Petroleum Underground Storage Tank Cleanup Funds

Page 9: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-9

How to meet financial responsibility requirements

• Self insurance (tangible net worth test)• Establish a trust fund• Guarantee• Insurance and risk retention group coverage• Surety bond• Letter of credit• Insurance pools

Page 10: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-10

How to meet financial responsibility requirements

• Four additional options for local governments

• Proof must be kept at location of tank or place of business

Page 11: ARE 309Ted Feitshans012-1 Unit 12 Underground Storage Tanks

ARE 309Ted Feitshans 012-11

Home Heating Oil Tanks

• Exempt, no closure requirements

• May impede property sales

• Regulated by local fire inspectors

• Leaks reported to DWM

• Non-commercial Leaking Petroleum UST Cleanup Fund