Airborne Sound Isolation Impact Sound Isolation Seismic Restraint Systems Ceiling Isolation Providing solutions to common noise and vibration problems since 1958. High STC Wall Systems Building Isolation Duct and Pipe Lagging Sound Control Floor Systems STC 84 IIC 70 FLOOR/CEILING IIC 51 STC 72 FLOOR/CEILING STC 73 IIC 70 FLOOR STC 57 to 64 WALL STC 76 IIC 62 FLOOR/CEILING STC 66 IIC 63 FLOOR IIC 59 FLOOR FIIC 72 ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control Building Systems for Floors, Walls, Ceilings, and Structures 13080/KIN BuyLine 1062 Select the Floor, Wall, or Ceiling to meet Design and Acoustical Criteria www.kineticsnoise.com/arch

Upload: lykien

Post on 11-Feb-2018

275 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

Airborne Sound IsolationImpact Sound IsolationSeismic Restraint SystemsCeiling Isolation

Providing solutions to common noise and vibration problems since 1958.

High STC Wall SystemsBuilding IsolationDuct and Pipe LaggingSound Control Floor Systems

STC 84IIC 70FLOOR/CEILING

IIC 51STC 72FLOOR/CEILING

STC 73IIC 70FLOOR

STC 57 to 64WALL

STC 76IIC 62FLOOR/CEILING

STC 66IIC 63FLOOR

IIC 59FLOORFIIC 72

ARCHITECTURAL AND STRUCTURALNOISE CONTROL SOLUTIONS

Sound Control Building Systems forFloors, Walls, Ceilings, and Structures

13080/KINBuyLine 1062

Select the Floor, Wall, or Ceiling to meet Design and Acoustical Criteria

www.kineticsnoise.com/arch

Page 2: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

For more information call 1.800.959.1164 or fax 614.889.0540

Kinetics® Noise ControlProviding solutions to common noise and vibration problems since 1958.

Kinetics®

compositeconstructionreduces soundtransmissionThe ProblemNoise and vibration are majorsources of occupant complaint inmodern buildings. Floors, walls,and ceilings reduce noise ac-cording to the Mass Law, whichstates that doubling of buildingweight will reduce the transmis-sion of sound by up to 6 decibels(dB). Example: a 4" concrete floorhas a sound transmission loss(TL) of 42 dB at 250 Hz. Doublingof the floor to 8" only increasesthe TL to 48 dB. A 6 dB reductionis about 25% quieter.

The SolutionBy introducing Kinetics® compos-ite construction systems, onecan achieve substantially highersound transmission loss. Kinet-ics® Floating Floors, IsolatedCeilings, Isolated Partitions, andComposite Barrier Materials allfar exceed the Mass Law capa-bility and provide greater airborneand structureborne noise control.(See diagram comparisons.)

CertificationKinetics Noise Control providescertified engineering drawingsupon request for its products toassure compliance with jobspecifications. Copies of inde-pendent test reports on specificsystems are available to archi-tects, engineers, and acousticalconsultants upon request.

2

Concrete or Wood Floating Floors

4" Concrete Structural Floor (50 psf)6" Concrete Structural Floor (75 psf)

Concrete “T” sections with 2" ofconcrete topping (75 psf)

4" Concrete Floating Floor1/2" Plywood Pouring FormKinetics® RIM L-2-12(using 2" thick KIP pads)Concrete “T” sections with 2" ofconcrete topping (75 psf)

1" Oak Hardwood Floor3" Tongue and Groove wood sub-floor

3/4" Red Oak Flooring3/4" Sleepers1-1/2" Gypcrete2 Layers 1/2" OSBKinetics® RIM-L-1-16(using 1" thick KIP pads)1" Oak Hardwood Floor3" Tongue and Groove wood sub-floor

3/8" Wood Sheathing2 Layers 3/4" Plywood*Kinetics® RIM-I-2-16(using 2" thick KIP pads)6" Concrete Slab

*Add 2 layers 5/8" Gypsum Boardbetween Plywood

DescriptionAcousticalProperties

STC

4953

54

73

-

FSTC-50

66

71

SectionsIIC

2528

24

70

FIIC-15

FIIC-45

63

64

CONVENTIONALCONSTRUCTION

CONVENTIONALCONSTRUCTION

Ceramic Tile7/16" Glass Mesh Mortar Unit5/8" Kinetics® SR FloorboardConcrete subfloor (56 psf)

Vinyl composition tile1" Gypsum-concrete3/4" Oriented Strand Board18" Deep floor trusses3" Insulation5/8" Gypsum Board on resilient channel

Vinyl composition tile1" Gypsum-concrete5/16" Kinetics® Soundmatt3/4" Oriented Strand Board18" Deep wood floor trusses3" Insulation5/8" Gypsum Board on resilient channel

59

FIIC-33

FIIC-51

59

-

-

WITHOUTSOUNDMATT

WITHSOUNDMATT

CONVENTIONALCONSTRUCTION

Sound Rated Floors Model SR and Soundmatt

LOFT EXPOSED BEAM(NO CEILING)

Page 3: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

3Product Data, Drawings, and Specs at www.kineticsnoise.com/arch

Kinetics® Sound Isolation Products for Floorand Ceiling Composite Construction Systems

13080/KINBuyLine 1062

Ceiling Isolation

DescriptionAcousticalProperties Sections

Parquet Floor1-1/2" Concrete5/8" Plywood3-1/2" Insulation2" x 10" Joists2 Layers 1/2" Gypsum Board

Parquet Floor1-1/2" Concrete5/8" Plywood3-1/2" Insulation2" x 10" JoistsKinetics® ICW Ceiling Hanger2 Layers 5/8" Gypsum Board

6” Concrete SlabSuper-Compact Model KSCHSpring/Neoprene Hanger1-1/2” Insulation2 Layers 5/8” Gypsum Board

6” Concrete SlabModel ICCSpring/Neoprene Hanger3-1/2” Insulation2 Layers 5/8” Gypsum Board

40

62

51

70

51

76

72

84

IIC STC

CONVENTIONALCONSTRUCTION

Sound Control Walls - Model IsoMax

2” x 4” Singe Wood Stud1 Layer 5/8” Gypsum Board, each side.IsoMax with Furring Channel, one side.RIM Insulation

Add 2nd Layer 5/8” Gypsum Board,on one side.

Add 2nd Layer 5/8” Gypsum Board,both sides.

57

61

64

DescriptionAcousticalProperties

STCSections

(see complete marking on product)

Sound Design andConstruction PracticeThe following items should beconsidered in order to achieve fullbenefit from Kinetics products.

1) An acoustical consultantshould be retained wheneverpossible. Their knowledge of asystems overall expected acous-tical performance and the criticaldetails that make a building de-sign work will better assure suc-cess.

2) Holes or any openings throughpartitions, ceilings, or floorsshould be caulked or sealed.Sound leaks of any kind will sig-nificantly reduce the effectivenessof the noise isolation barrier.

3) Doors and windows in the par-titions should exhibit high STCratings to maintain high perfor-mance.

4) Electric outlets thru-the-wallcabinets, etc., should not beplaced back-to-back in order toprevent potential excessive trans-mission of noise.

5) Masonry walls should be plas-tered or sealed with a hard coat-ing.

6) Acoustical treatment and ab-sorptive finishes may be used innoisy rooms to reduce the rever-beration and overall noise levelwithin these rooms.

7) All floating floors, partitions,and ceilings should be con-structed with care. Constructionerrors such as rigid ties, fastenershort-circuiting, improper floor re-inforcing, etc., can create a soundflanking conduit and should beavoided. Supervision by a repre-sentative of the isolation mate-rial manufacturer can minimizefield errors.

Page 4: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

4

Kinetics® Floating Concrete FloorModel RIM Roll-out Isolation Material for Concrete Floated FloorsSTC 73 and IIC 70 ratings - Premier floating floor system selected by acousticalconsultants and architects for sound isolated floor construction in hospitals,performing arts centers, schools, recording studios, office buildings, and any otherbuilding where noise control is an issue.

For more information call 1.800.959.1164 or fax 614.889.0540

Physical properties/benefits• For loads from 2.5 to 500 PSI.• Natural frequencies of 8 to 15 Hz.• Stable, inert material maintains a constant resilience and natural frequency over its life.• Custom Pad sizes and load capacities as required by designer.

Available in various densities andspring rates to provide load-bearingcapacities ranging from 2.5 to 500 psi.

Leaf springs of stabilized glassfibers bonded to each other with awater-resistant resin.

Flexible moisture-impervious membrane

The three key components for reducing sound transmission through any composite floor system you design. KIPIsolation Pads are used in our popular RIM system. Turn the page for more information.

Air Space, Mass, Kinetics® Isolation PadsModel KIP Isolation Pads

Page 5: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

5Product Data, Drawings, and Specs at www.kineticsnoise.com/arch

Kinetics® Liftslab Floating FloorModel LSM Spring Liftslab and Model FLM Pad Liftslab

Kinetics® Floating Wood FloorModel RIM Roll-out Isolation Material for Built-up Floated FloorsSTC 66 and IIC 63 ratings - Excellent for creating a resilient sound control composite woodfloor construction for aerobics, dance, exercise, stage, and loft style floors. Compositewood floor build-ups are often used where concrete is not practical.

FLM Liftslab detail after raising floor.Model FLM incorporates Kinetics

Model KIP or Neoprene Isolation pads.

LSM spring liftslab perimeter detailafter raising floor. For addressing the

most critical structureborne andimpact isolation criteria

Kinetics® Model KIP Isolation Pads withWood Nailer & Steel Channel

13080/KINBuyLine 1062

LOFTSTYLE

Page 6: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

1

Kinetics® Sound Rated Floors

Kinetics Type SR Floorboard is the premier underlayment for control ofimpact noise in condominiums, apartments, multifamily dwellings,commercial buildings, and other areas where footfall and impact noisecan be the cause of complaints.

Type SR Floorboard is a unique 5/8" thick underlayment material whichsubstantially reduces sound transmission through hard surface floor

systems. Ratings of IIC (Impact Insulation Class) 50 to 65 have been achieved in typical applications, compared withIIC-25 to 34 with conventional construction. Where a preference for hard surface floors such as ceramic tile, marble,hardwood flooring or vinyl tile make impact noise an issue, SR Floorboard is recommended. Call for details.

Model Soundmatt Low profile underlayment for Sound Control

Kinetics Soundmatt is a floor underlayment used to control sound transmission of both impact and airborne noise infloor systems. Soundmatt is a 5/16" (8 mm) thick underlayment used to substantially improve IIC (impact) and STCnoise ratings while minimizing the elevation change.

Impact noise can be intrusive to occupants in spaces below. Construction that calls for hard floor surfaces such ashardwood flooring, ceramic tile, quarry tile, marble, wood parquet and vinyl tile are all areas where impact noise is ofconcern. Without a floor underlayment, intrusive impact noise can be objectionable.Please contact Kinetics for specifications.

Certified:Soundmatt and SR Floorboard have been tested with the Tile Council of America, Inc., using method ASTM-C627. Bothsystems achieved a Residential rating or greater for durability under load.

STC - 58 IIC - 54 STC - 60 IIC - 53

For more information call 1.800.959.1164 or fax 614.889.0540

2 3

8" Flexicore concrete subfloor

8" Flexicore concrete subfloor

STC - 60 IIC - 65 STC - 59 IIC - 59 FSTC - 54 FIIC - 53

STC - 63 IIC - 54

6

Model SR Floorboard Superior Sound Rated Floor Underlayment

1 2 3

Page 7: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

Product Data, Drawings, and Specs at www.kineticsnoise.com/arch 7

13080/KINBuyLine 1062New Products for Wall and Ceiling

Sound ControlModel IsoMax Resilient Sound Isolation Wall and Ceiling Clip

Model KSCH Super Compact Ceiling Sound Isolation Hanger

3-1/2”

IsoMax cost effectively sound isolates gypsum board and furring channelfrom the steel and wood framing or concrete/masonry structure.Superior to conventional resilient channel in performance. Lower installedcost than double stud wall assemblies with similar performance.

Wood stud partition, 2 x 4, 16” O.C. with5/8’ gypsum board, one layer one side,two layers on opposite side. R19 fiber-glass in cavity. IsoMax clips and 7/8”furring channel.

STC 61

(see completemarking on product)

STC 72 IIC 51

Model KSCHPatent Pending

Maximize Sound Control and Ceiling Height with a spring and neopreneisolation hanger which carries standard 1-1/2” cold rolled steel channelthrough its center cradle.

6” Concrete Slab1-1/2” InsulationKSCH HangerCold Rolled Steel Channel7/8” furring channel2 Layers 5/8” Gypsum Board

Model IsoMaxPatent Pending

Page 8: ARCHITECTURAL AND STRUCTURAL NOISE CONTROL … Arch Separation Products.pdf · ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS Sound Control ... Control provides certified engineering

Kinetics Duct and Pipe Lagging Barrier - Type KNM-100ALQKinetics Model KNM-100ALQ noise barrier is a composite mate-rial designed to reduce the sound transmission of ductwork, pipingand equipment housings by combining a fire rated limp mass witha decoupling quilted fiber glass lining. (KNM-100AL is availablewithout the quilted fiber glass lining).

• Meets Class 1 fire rating requirements• STC 28*• 1" or 2" fiber glass decoupler included

Product

KNM 100ALQ-1KNM 100ALQ-2

125

1311

250

1616

500

2426

1000

3335

2000

4344

4000

4949

STC

28*28*

Frequency, Hz

Kinetics Noise Control and GERB Vibration Control Systems U.S.A., Inc. formed a partnership in 2001 toaddress vibration isolation and structural noise control in building construction. Expansion of the DallasConvention Center, completed in 2002, required the building addition to be isolated from noise and vibrationgenerated from freight and commuter trains passing on tracks below. Kinetics/GERB engineered and pro-duced spring and pad isolators to meet stringent requirements outlined in the specification.

Kinetics’ new ATLAS pad offers exceptional load capacity and vibration control in a natural rubber or neoprenemount. Visit our web sites to learn more about the products Kinetics Noise Control (www.kineticsnoise.com)and GERB Vibration Control Systems, Inc. (www.gerb.com) offer for building isolation.

Kinetics/GERBStructural Bearing Solutions for Building Isolation

Kinetics Noise Control, Inc.6300 Irelan Place • P.O. Box 655 • Dublin, Ohio 43017Phone: 614.889.0480 • Fax: 614.889.0540www.kineticsnoise.com

For complete specifications and details for anyof the products shown in this brochure call1.800.959.1164. Or FAX to 614.889.0540.

Printed in the U.S.A.

* Rating is for material tested as a free hanging barrier. Performancewill be lower when wrapping duct, pipe or equipment. Contact thefactory for sound reduction estimates.

Kinetics/GERBSpring Isolation Elements

Model ATLAS Rubber Structural BearingPatent Pending