architect’s addendum no. “1” · 2021. 1. 18. · 102 mary alice park drive suite 103 cumming,...
TRANSCRIPT
-
J E R I C H O D E S I G N G R O U P
ARCHITECT’S ADDENDUM NO. “1”
TO: ALL HOLDERS OF CONSTRUCTION DOCUMENTS AND SPECIFICATIONS CONSTRUCTION DOCUMENT SUBMITTAL January 15, 2021
PROJECT: BL006-21Gwinnett County Fire Apparatus Renovation 650 Swanson Drive Lawrenceville, GA 30043 OWNER: Gwinnett County Department of Support Services ARCHITECT: Jericho Design Group, LLC 102 Mary Alice Park Drive Suite 103 Cumming, GA 30040
The items listed on the attached pages take precedence over referenced portions of Contract Documents for the project and, in executing a contract, shall become a part thereof. Where any item called for in the Contract Documents is supplemented hereby, the original requirements shall remain in effect. All supplemental conditions shall be considered as added thereto. Where any original item is amended, voided, or superseded hereby, the provisions of such items not so specifically amended, voided, or superseded shall remain in effect.
PART 1 - CHANGES TO THE DRAWINGS
1-1 Sheet A-7.01 DOOR & WINDOW SCHEDULE AND ELEVATIONS:
1. Added W3 Elevation 3/A-7.01 2. Reference Sheet A-7.01 DOOR & WINDOW SCHEDULE AND ELEVATIONS revised under
Addendum 1 dated January 15, 2021.
1-2 Sheet ID-6.01 FURNITURE & EQUIPMENT PLAN: 1. Added note for specifications for TV/Monitor Displays 2. Reference Sheet ID-6.01 FURNITURE & EQUIPMENT PLAN revised under Addendum 1 dated
January 15, 2021. PART 2 - CHANGES TO THE SPECIFICATIONS
2-2 SECTION 12 20 00 – WINDOW TREATMENT:
1. Revised 1.01 B to remove motorized unit requirement. 2. Revised 1.03 D to remove requirement for black out shades and the requirement to provide electrical
components that are UL listed. 3. Revised 1.04 A to remove black-out shades and sunscreen requirement.
-
J ERI CHO DESIGN G ROUP Page 2 of 2
ARCHITECT’S ADDENDUM
PART 3 – CONTRACTOR QUESTIONS/PRE-ID REQUESTS FOR INFORMATION
Questions received and answers in red:
1. Please provide a copy of the pre-bid meeting sign in sheet. See attached
2. What is the anticipated start date? The anticipated Construction Start Date is May 1, 2021.
3. What are the Liquidated Damages for this project? No
4. Is there an anticipated construction cost or an Owner???s Stated Cost Limitation for this project? There
is approved funding for this project. Gwinnett County expects each contractor to bid a competitive
price. Award will be made to the lowest responsive and responsible bidder.
5. Will the General Contractor be responsible to include the costs of any permit fees? There are no pay
permit fees on this project, but the General Contractor will be responsible for obtaining all necessary
permits.
6. Will the General Contractor be responsible to include the costs of materials testing and/or special
inspections? No.
7. Will the General Contractor be responsible to include the costs of hazardous materials
testing/abatement? No.
8. Please clarify what the deck height for the existing structure is. Existing Deck height is 19’-10” to roof.
Underside of deck above to unoccupied Attic Space is 10’-8”
9. Specs call for motorized aluminum blinds and blackout shades. Please clarify where these are required.
Revised specifications to remove requirements for motorized blinds and shades.
10. Please provide dimensions for Window W3. Revised Sheet A-7.01 Door & Window Schedule and
Elevations.
11. Please provide a spec for the EQ-1A and EQ-1B Monitors shown on ID-6.01. Revised Sheet ID-6.01
Furniture & Equipment Plan.
END OF ADDENDUM NO. 1
-
GENERAL NOTES
1. SEE GENERAL SPECIFICATIONS FOR DOOR AND FRAME FINISHES.2. ALL DOOR HARDWARE SHALL BE HANDICAP ACCESSIBLE, COMPLYING
WITH 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN.3. WHERE DISCREPANCIES OCCUR BETWEEN THE DOOR SCHEDULE NOTES
AND HARDWARE SPECIFICATIONS, NOTIFY THE ARCHITECT OF DISCREPANCIES TO RECEIVE DIRECTION ON HOW TO PROCEED.
4. TIE MAGNETIC LOCK INTO FIRE ALARM. 5. REFER TO THE PARTITION TYPE OR APPLICABLE WALL SECTION AND
THEN TO TYPICAL DOOR DETAILS FOR APPROPRIATE DETAIL.6. ALL EXTERIOR HOLLOW METAL DOORS TO BE INSULATED.7. ALL EXTERIOR DOORS TO BE WEATHER STRIPPED AND HAVE CLOSERS.8. ALL FIRE RATED DOORS TO HAVE CLOSERS9. PROVIDE BRASS STOP BAR TRANSITION STRIPS AT THE FOLLOWING
FLOORING TRANSITIONS: WOOD-PORCELAIN, WOOD-CARPET, CARPET-PORCELAIN.
ABBREVIATIONS LEGENDDOOR MATERIAL TYPE
ALUM - ALUMINUMHM - HOLLOW METALPLAM - PLASTIC LAM CLADSCWD - SOLID CORE WOOD
FINISH TYPE
STD - STAINPTD - PAINTPF - PREFINISHED
FRAME MATERIAL TYPE
ALUM - ALUMINUMHM - HOLLOW METALSTL - STEELWD - WOOD
GLAZING TYPE
T - CLEAR TEMPERED GLASSTT - TINTED & TEMPERED GLASSIT - INSULATED TEMPERED GLASS
* REFER TO ADA REGULATORY DIAGRAMS FOR MORE INFORMATION
1
FRAME ELEVATIONS
SCALE : 1/4"=1'-0"
DOUBLE DOOR
FSINGLE DOOR
F2
DOOR ELEVATIONS
SCALE : 1/4"=1'-0"
HG
HG2
6"6" 2"
2"
2"
T T
6"
MA
X
3' -
7"
2" 3' - 2" 2"
2"
3' -
8"
2"
7
A-7.01
9
A-7.01
8
A-7.01
T
2" 4' - 8" 2"
2"
3' -
8"
2"
11
A-7.01
11
A-7.01
11
A-7.01IT
2" 3' - 2" 2"
2"
3' -
4"
8" COUNTERTOP
OPEN
7
A-7.01
7
A-7.01
10
A-7.01
T
METAL STUDS -SEE PLANS FOR WALL TYPE
5/8" GYPSUM BOARD (BOTH SIDES)
DOOR AS SCHEDULED
HOLLOW METAL FRAME
2"
BOX HEADER -SEE STRUCTURAL
SEALANT BOTH SIDES
SOUND INSULATION
1/2"1/2"
2"METAL STUDS -SEE PLANS FOR WALL TYPE
5/8" GYPSUM BOARD (BOTH SIDES)
DOOR AS SCHEDULED
HOLLOW METAL FRAME
SEALANT BOTH SIDES
SOUND INSULATION
1/2
"1/2
"
EXISTING
MATCH
EXISTING FRAMING
5/8" GYPSUM BOARD
ALUMINUM STOREFRONT SYSTEM
EXISTING BATT INSULATION
SHIM PROVIDED BY MANUF.
PERIMETER SEALANT
CONTINUOUS 2x PT NAILER, RIP TO FIT -FRT WOOD AT RATED WALLS, TYP.
BACKER ROD & SEALANT BOTH SIDES
STAINLESS STEEL FLASHING WITH HEMMED EDGE - COLOR
TO MATCH SIDING, TYP.
EXISTING METAL BUILDING SYSTEM
EXISTING FRAMING
5/8" GYPSUM BOARD
ALUMINUM STOREFRONT SYSTEM
BATT INSULATION
PERIMETER SEALANTBACKER ROD & SEALANTBOTH SIDES
EXISTING METAL BUILDING
SHIM PROVIDED BY MANUF.
COLUMN
SCHEDULED SILL TO MATCH EXISITNG
CONTINUOUS 2x PT NAILER, RIP TO FIT -FRT WOOD AT RATED WALLS, TYP.
SUB SILL BY STOREFRONT MANUF., SET IN FULL BED OF MASTIC
PROVIDE PT BLOCKING AT EACH STUD - CONTINUOUS SIDING VENT AND BUG SCREEN BETWEEN BLOCKING
1"
EXISTING
MATCH
BACKER ROD & SEALANT BOTH SIDES
ALUMINUM STOREFRONT SYSTEM
CO
LU
MN
EX
IST
ING
MA
TC
HEXISTING METAL BUILDING
EXISTING FRAMING
5/8" GYPSUM BOARD
BATT INSULATION
CONTINUOUS 2x PT NAILER, RIP TO FIT -FRT WOOD AT RATED WALLS, TYP.SCHEDULED
SILL BELOW
SHIM PROVIDED BY MANUF.
PERIMETER SEALANT
1/2"
5/8
"
2"
REFER PARTITION TYPES
REMOVABLE STOP
SCHEDULED GLAZING ON ROOM SIDE OF HM FRAME -TYP
1/2"
5/8
"
2"
REFER PARTITION TYPES
REMOVABLE STOP
SCHEDULED GLAZING ON ROOM SIDE OF HM FRAME -TYP
FRAME ANCHORS (MIN 3 PER SIDE)
INTERIOR OF OFFICE SIDE
1/2"
5/8
"
2"
REFER PARTITION TYPES
REMOVABLE STOP
SCHEDULED GLAZING ON ROOM SIDE OF HM FRAME -TYP
REFER PARTITION TYPES
SCHEDULED GLAZING ON ROOM SIDE OF HM FRAME -TYP
8"
BOTTOM STOP
SOLID SURFACE TRANSACTION TOP AS SPECIFIED
18"
6" 8"
OFFICE SIDE DAYROOM SIDE
7
A-7.01
8
A-7.01
9
A-7.01
2" 2' - 11" 2" 2' - 11" 2"2"
3' -
0"
2"
102 Mary Alice Park Road, Suite 103Cumming, GA 30040
2020,
Jericho D
esig
n G
roup,
LLC
. T
hese d
raw
ings a
re p
rote
cte
d b
y t
he c
opyright
law
s o
f th
e U
nited S
tate
s.
These d
raw
ings o
r any
part
there
of
may n
ot
be u
sed f
or
any p
urp
ose o
r re
pro
duced in a
ny f
orm
or
by a
ny m
eans w
ithout
the w
ritt
en c
onsent
of
Doug S
haw
.
Sheet No.
Date
Sheet Title
Job No.
Drawn By Checked By
PRINT RECORD
RELEASED FOR CONSTRUCTION
1
A
2 3 4 5 6
BC
DE
1/1
5/2
021
11
:54
:37
AM
C:\U
sers
\ejo
hnson
\Docum
en
ts\2
00
24
_G
WC
O F
ire
App
ara
tus R
eno
va
tion
_A
RC
H_
RV
T1
9C
_e
john
so
n7
QH
E5
.rvt
A-7.01
DOOR & WINDOWSCHEDULE ANDELEVATIONS
10/16/2020 20024
WR JDG
GW
CO
FIR
E A
PP
AR
AT
US
RE
NO
VA
TIO
N
GW
INN
ET
T C
OU
NT
Y
65
0 S
WA
NS
ON
DR
IVE
LA
WR
EN
CE
VIL
LE
, G
A 3
00
43
DOOR SCHEDULE
NO.
DOOR FRAME DETAILS
FIR
E R
AT
ING
HA
RD
WA
RE
SIG
NA
GE
RE
Q'D
*
NOTESELEVATIONSINGLE /
PAIR WIDTH HEIGHT THICK. MATL. FINISH ELEVATION MATL. FINISH HEAD JAMB SILL
102 F SINGLE 3' - 0" 7' - 0" 1 3/4" HM STD F1 HM PTD - P-2 5/A-7.01 -- -- INT-REST RESTROOM
105 F SINGLE 3' - 0" 7' - 0" 1 3/4" HM STD F2 HM PTD - P-2 5/A-7.01 6/A-7.01 -- -- INT-OFFICE OFFICE
108 F SINGLE 3' - 0" 7' - 0" 1 3/4" HM STD F1 HM PTD - P-2 5/A-7.01 6/A-7.01 -- INT-OFFICE OFFICE
109 F SINGLE 3' - 0" 7' - 0" 1 3/4" HM STD F1 HM PTD - P-2 5/A-7.01 6/A-7.01 -- INT-OFFICE OFFICE
110 HG2 PAIR 6' - 0" 7' - 0" 1 3/4" HM STD EXISTING EXISTING PTD - P-2 EXISTING EXISTING -- INT-OFFICE OFFICE
120 F2 PAIR 6' - 0" 7' - 0" 1 3/4" HM STD 2 HM PTD - P-2 5/A-7.01 6/A-7.01 -- EXISTING N/A SALVAGED - RELOCATED
121 F2 PAIR 6' - 0" 7' - 0" 1 3/4" HM STD 2 HM PTD - P-2 5/A-7.01 6/A-7.01 -- EXISTING N/A SALVAGED - RELOCATED
DOOR HARDWARE TYPE
HARDWARECODE APPLICATION
CLOSER HINGES TRIM HANDLESET / LOCKSET / LATCH SECURITY ETC.
HARDWARE COMMENTSST
AN
DA
RD
CLO
SE
R
CLO
SE
R W
/ S
TO
P, H
OLD
OP
EN
CLO
SE
R W
ITH
ST
OP
CO
NC
EA
LE
D C
LO
SE
R W
/ S
TO
P
CO
NT
INU
OU
S H
ING
E
OF
FS
ET
PIV
OT
S
ST
AN
DA
RD
HIN
GE
BA
LL-B
EA
RIN
G H
ING
E
NO
N-F
ER
RO
US
BB
WIT
H N
.R.P
.
CO
NC
EA
LE
D P
IVO
TS
WE
AT
HE
RS
TR
IP / G
AS
KE
TIN
G
BU
MP
ER
S
TH
RE
SH
OLD
FLO
OR
SW
EE
P
WA
LL-M
OU
NT
DO
OR
ST
OP
KIC
K-D
OW
N H
OLD
OP
EN
FLO
OR
ST
OP
RA
IN D
RIP
MO
P P
LA
TE
KIC
K P
LA
TE
AR
MO
R P
LA
TE
LO
CK
GU
AR
D
RO
BE
HO
OK
MO
RT
ISE
CY
LIN
DE
R (
DE
AD
BO
LT
)
ST
OR
EF
RO
NT
PU
LL &
PU
SH
BA
R
PA
SS
AG
E L
EV
ER
SE
T
EN
TR
Y L
OC
KS
ET
OF
FIC
E L
EV
ER
SE
T
OF
FIC
E L
OC
KS
ET
ST
OR
ER
OO
M L
EV
ER
SE
T
PR
IVA
CY
LO
CK
SE
T
KE
Y P
AD
PA
NIC
BA
R E
XIT
DE
VIC
E
PU
SH
/PU
LL L
EV
ER
SE
T W
ITH
PLA
TE
EX
TE
ND
ED
DE
CO
RA
TIV
E P
ULL
2N
D E
NT
RY
LO
CK
SE
T
MO
RT
ISE
PU
LL (
RE
CE
SS
PU
LL)
FLU
SH
BO
LT
S (
PA
IR D
OO
RS
ON
LY
)
MA
GN
ET
IC L
OC
K
ELE
CT
RO
NIC
CA
RD
RE
AD
ER
MA
GN
ET
IC L
OC
K P
LA
TE
& C
OV
ER
J-B
OX
FIR
E A
LA
RM
SY
ST
EM
INT-LOCK MGR OFFICES (WOOD OR HM) ● ● ● ● ●
INT-OFFICE OFFICE DOOR (WOOD OR HM) ● ● ● ●
INT-REST RESTROOM DOOR ● ● ● ● ● ● ● ●
SCALE: 1/2" = 1'-0"
W1 ELEVATION1 SCALE: 1/2" = 1'-0"W2 ELEVATION2 SCALE: 1/2" = 1'-0"
W4 ELEVATION4
SCALE: 3" = 1'-0"
HM HEAD DETAIL5 SCALE: 3" = 1'-0"HM JAMB DETAIL6
SCALE: 1 1/2" = 1'-0"
STOREFRONT HEAD DETAIL11
SCALE: 1 1/2" = 1'-0"
STOREFRONT SILL DETAIL12
SCALE: 1 1/2" = 1'-0"
STOREFRONT JAMB DETAIL13
1 HR
103 F SINGLE 3'-0" 7'-0" 1 3/4" HM PTD EXISTING HM PTD - P-2 EXISTING EXISTING -- INT-REST RESTROOM
SCALE: 1 1/2" = 1'-0"
WINDOW - HEAD DETAIL7
SCALE: 1 1/2" = 1'-0"
WINDOW - JAMB DETAIL8 SCALE: 1 1/2" = 1'-0"WINDOW SILL9 SCALE: 1 1/2" = 1'-0"
WINDOW SILL @ TRANS10
No
. DATE DESCRIPTION
08/14/2020 50% Construction Documents
09/23/2020 95% Construction Documents
10/16/2020 100% Construction Documents
A 11/11/2020 Addendum A
1 01/15/2021 Addendum 1
SCALE: 1/2" = 1'-0"
W3 ELEVATION31
-
REF
EQ-1B
EQ-1B
EQ-2EQ-1A
EQ-1A
EQ-1A
EQ-IC
EQ-2
EQ-2
EQ-2EQ-2
EQ-2EQ-2
EQ-3
EQ-4A EQ-4B
EQ-4C
MECHANICS/DRIVERS
110
LT. OFFICE
109
SECTION MGR
108
BSA
102
DAYROOM
101
MENS RR
105
WOMENS RR
103 MECH
107
VESTIBULE
104
CORRIDOR
106APPARATUS BAY
111
STORAGE
112B
STORAGE
112A
WASH BAY
112
TA-G-01
SEE TOILET ACCESSORIES
OVERHEAD FURNITURE CABINET; SEE REFERENCE PLAN FOR BLOCKING NOTE
OVERHEAD FURNITURE CABINET; SEE REFERENCE PLAN FOR BLOCKING NOTE
EQ-4D
FURNITURE, FIXTURE & EQUIPMENT GENERAL NOTES
1. GENERAL CONTRACTOR TO COORDINATE SCHEDULED ITEMS WITH OWNER AND OWNER'S EQUIPMENT REPRESENTATIVE. THIS INCLUDES VERTICAL AND HORIZONTAL MOUNTING HEIGHTS OF ALL DEVICES, COORDINATION WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING.2 LOW VOLTAGE BY OWNER'S EQUIPMENT REPRESENTATIVE, U.N.O.3. FURNITURE & EQUIPMENT SHOWN HATCHED IS TO BE PROVIDED BY OWNER.4. GENERAL CONTRACTOR TO COORDINATE WITH OWNER/OWNER REPRESENTATIVE ON DELIVERY SCHEDULE AND INSTALLATION FOR ALL FFE.5. FURNITURE SHOWN IS TO BE PURCHASED BY OWNER UNDER SEPARATE SUBMITTAL. CONTRACTOR TO COORDINATE WITH CONSTRUCTION SCHEDULE.
102 Mary Alice Park Road, Suite 103Cumming, GA 30040
2020,
Jericho D
esig
n G
roup,
LLC
. T
hese d
raw
ings a
re p
rote
cte
d b
y t
he c
opyright
law
s o
f th
e U
nited S
tate
s.
These d
raw
ings o
r any
part
there
of
may n
ot
be u
sed f
or
any p
urp
ose o
r re
pro
duced in a
ny f
orm
or
by a
ny m
eans w
ithout
the w
ritt
en c
onsent
of
Doug S
haw
.
Sheet No.
Date
Sheet Title
Job No.
Drawn By Checked By
PRINT RECORD
RELEASED FOR CONSTRUCTION
1
A
2 3 4 5 6
BC
DE
1/1
5/2
021
11
:54
:34
AM
C:\U
sers
\ejo
hnson
\Docum
en
ts\2
00
24
_G
WC
O F
ire
App
ara
tus R
eno
va
tion
_A
RC
H_
RV
T1
9C
_e
john
so
n7
QH
E5
.rvt
ID-6.01
FURNITURE &EQUIPMENT PLANS
10/16/2020 20024
WR JDG
GW
CO
FIR
E A
PP
AR
AT
US
RE
NO
VA
TIO
N
GW
INN
ET
T C
OU
NT
Y
65
0 S
WA
NS
ON
DR
IVE
LA
WR
EN
CE
VIL
LE
, G
A 3
00
43
EQUIPMENT SCHEDULE (EQ-)
TAG NO. DESCRIPTION
FURNISHED BY INSTALLED BY
NOTESCONTRACTOR OWNER CONTRACTOR OWNER
EQ-1A 32"- 40" MONITOR; WALL MOUNTED @ 60"AFF; ● ● GC TO COORDINATEELECTRICAL/DATA. PROVIDE WALLBLOCKING DETAIL. SEE NOTE ONID-6.01 FOR SPECIFICATIONS.
EQ-1B 50" - 60" MONITOR; WALL MOUNTED @ 72"AFF; ● ● GC TO COORDINATEELECTRICAL/DATA. PROVIDE WALLBLOCKING DETAIL. SEE NOTE ONID-6.01 FOR SPECIFICATIONS.
EQ-2 COMPUTER MONITOR, FLAT SCREEN, KEYBOARD ● ● GC TO COORDINATEELECTRICAL/DATA. COORDINATEGROMMET LOCATIONS WITHOWNER
EQ-3 COPIER ● ● RELOCATED AND REINSTALLED
EQ-4A REFRIDGERATOR - WHIRLPOOL WRS588FIHZ ● ●
EQ-4B ELECTRIC RANGE 36" - VERONA VEFSEE365SS ● ●
EQ-4C MICROWAVE - WHIRLPOOL WMC50522HZ ● ●
EQ-4D ANSUL HOOD ● ● SEE MEP DRAWINGS FORINFORMATION
EQ-IC 70" - 80" MONITOR; WALL MOUNTED @ 72"AFF ● ● GC TO COORDINATEELECTRICAL/DATA. PROVIDE WALLBLOCKING DETAIL
No
. DATE DESCRIPTION
08/14/2020 50% Construction Documents
09/23/2020 95% Construction Documents
10/16/2020 100% Construction Documents
A 11/11/2020 Addendum A
1 01/15/2021 Addendum 1
NOTE:A. To be considered a Smart TV, the LED TV/Display must possess at least six of the following native (built-in) applications at a minimum:
1. Netflix2. Web Browser3. YouTube4. Facebook5. Pandora6. Hulu/Hulu+7. Amazon Prime8. Vudu9. Web Browser (Flash enabled)10. Skype (with auxiliary or integrated HD camera)11. TV Manufacturer specific app store12. LED TV/Displays without the required quantity of native applications can be made Smart TV capable with the addition of one of the
following:a. Roku 3b. AppleTVc. GoogleTVd. Android TV Boxe. WD TV Livef. ChromeBoxg. ChromeCast
B. Entertainment Grade LED TV/Displays are to be provided complete with appropriate mounting hardware, brackets, housings, safety straps, seismic restraints, connecting cables, and other miscellaneous materials as required for proper operation and as required by local safety codes.
C. Entertainment Grade LED TV/Displays are to be provided and installed with sizes and in locations reflected in the floor plan drawings.
D. Basis of Design/Exemplar Product:1. Sharp Aquos Quattron Series
1
-
Gwinnett County Fire Apparatus Interior Renovation WINDOW TREATMENT
Project #BL006-21 12200-1
SECTION 12 20 00
WINDOW TREATMENT
PART 1 GENERAL
1.01 SUMMARY
A. Furnish labor, equipment, materials and services to provide window treatments, accessories and attaching hardware as specified herein at locations shown or scheduled on the drawings. If no locations or schedules shown on drawings, provide the specified materials at all window locations.
B. This section includes: 1. Metal horizontal louver blinds.
1.02 SUBMITTALS A. Product Data: For each type of treatment described below including data on physical
characteristics, warranties, and recommendations for maintenance and cleaning. B. Shop Drawings: At 1/4 inch scale showing location and extent of treatments including
installation details. C. Samples:
1. Fabric/Shade Cloth: For initial selection purposes showing full range of colors available for each type of treatment specified.
1.03 QUALITY ASSURANCE A. Obtain each type of treatment from one source of a single manufacturer. B. Flame-retardant fabrics shall meet the requirements of the National Fire Protection
Association (NFPA) 701 Flame Test.
1.04 DELIVERY, STORAGE, AND HANDLING A. Do not deliver items to the site, until all specified submittals have been submitted to and
approved by the Architect. B. Do not deliver shades to the project until all concrete, masonry, plaster and other wet
work has been completed and is dry. C. Deliver prefabricated shades to site in labeled protective packages, uniquely identified
for each intended location. Schedule delivery to prevent delays but minimize on-site storage.
1.05 FIELD CONDITIONS A. Prior to installations, building shall be enclosed. Interior temperature shall be maintained
between 50 and 85 degrees F. and relative humidity shall not exceed 60%. B. Check openings by field measurements before fabrication. Where field measurements
cannot be made without delaying the work, guarantee opening dimensions and proceed with fabrication of treatment without field measurements. Coordinate wall and ceiling construction to ensure that actual opening dimensions correspond to guarantee dimensions.
-
Gwinnett County Fire Apparatus Interior Renovation WINDOW TREATMENT
Project #BL006-21 12200-2
1.04 MAINTENANCE A. Clearly label all spare components and supply to Owner upon completion in original
packaging for storage on site by Owner.
PART 2 PRODUCTS
2.01 MANUFACTURERS { Edit out types and manufacturers not used. }
A. Metal Horizontal Louver Blinds 1. Hunter Douglas, Inc. (Pearl River, NY) (www.hunterdouglasgroup.com) 2. Levelor Corporation (High Point, NC) (www.levolor.com) 3. Springs Window Fashions (Montgomery, PA) (www.springswindowfashions.com) ;
Graber. 4. Caco, Inc. Window Fashions (Johnson City, TN) (www.cacoinc.com)
2.02 MATERIALS AND FABRICATION
A. Metal Horizontal Louver Blinds
1. Slats: Shall be aluminum alloy 6011, heat treated, no reprocessed metals, 1" wide x .0073" thick before painting.
2. Headrail: Shall be 1" x 1 9/16" .025" steel, treated to resist corrosion, formed into a U- shape with rolled edges, coated with a baked-on polyester finish to match slats. Hardware shall be enclosed in the headrail.
3. Tilter: Shall be worm and gear type of die-cast metal, enclosed in a .031" thick housing of engineered polymer, with clutch action.
4. Tilt Wand: Shall be extruded, clear acrylic with tubular construction, 5/16" diameter, and detachable without tools.
5. Tilt Rod: Shall be solid steel with corrosion resistant finish. Torsional strength of tilt rod: angle of twist shall not exceed 6 degrees when loaded as the equivalent of a 120" x 120" blind in the closed position when using mating tape eccentrics.
6. Cord Lock: Shall be engineered polymer housing with nickel plated die-cast bearing surface and brass locking dogs. The locking device shall be crash proof.
7. Bottom Rail: Shall be .031" steel, treated to resist corrosion, with baked-on polyester paint, color coordinated to slats. It shall be formed with a double-lock seam into a closed shape, with color matching end caps. Equip to accept hold-down pins and be able to withstand 1/2 ft. lbs. of torque per foot.
8. End Locks: Shall be .024" steel with adjustable tab for centering blinds. 9. Braided Ladder: Shall be 100% polyester yarn with spacing not more than [ 21.5 mm,
14.2 slats per foot ] [ privacy, 18 mm, with hidden rout holes ] of drop. 10.Lift Cords: Shall be two-ply polyester cord filler and braided polyester jacket, .070" in
diameter. 11.Installation Brackets: Brackets shall be .048" steel with polyester baked-on finish to
match handrail. Blinds over 60" wide shall have intermediate support brackets with maximum spacing 60".
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that all blocking and framing necessary to carry shade assembly hardware is properly installed and secure.
3.02 INSTALLATION - GENERAL
A. Blinds and shades shall be installed square and level. Maximum variation of gap at window opening perimeter shall be 0.25 inch in 8 feet of height. Leave all units in perfect working
-
Gwinnett County Fire Apparatus Interior Renovation WINDOW TREATMENT
Project #BL006-21 12200-3
order, free from defect. B. Unless otherwise noted on the drawings, provide blinds on inside face of exterior windows, inside
face of interior windows located in offices and inside face of windows (corridor side) between corridor and apparatus bay area.
END OF SECTION 122000