SECTION 10 71 13.19 EXTERIORROLLING SHUTTERS Display hidden notes to specifier. (Don't know how? Click Here ) Copyright 2019 - 2019 ARCAT, Inc. - All rights reserved 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Exterior Rolling Shutters. 1.1.2 Exterior Security Rolling Shutters. 1.1.3 Exterior Hurricane Rolling Shutters. 1.2 RELATED SECTIONS 1.2.1 Section 04 20 00 - Unit Masonry. 1.2.2 Section 06 10 00 - Rough Carpentry0 - Rough Carpentry; for rough opening and blocking required for installation of shutters. 1.2.3 Section 08 50 00 - Windows. 1.2.4 Section 26 00 00 - Electrical. 1.3 REFERENCES 1.3.1 AAMA 2604/05 - Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels; 1998. 1.3.2 ASTM International (ASTM): 1.3.2.1 ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials. 1.3.2.2 ASTM E330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference. 1.3.2.3 ASTM E1886, Standard Test Method for Performance of 10 71 13.19-1

Upload: others

Post on 06-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

SECTION 10 71 13.19EXTERIORROLLING SHUTTERS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2019 - 2019 ARCAT, Inc. - All rights reserved

1 GENERAL

1.1 SECTION INCLUDES

1.1.1 Exterior Rolling Shutters.

1.1.2 Exterior Security Rolling Shutters.

1.1.3 Exterior Hurricane Rolling Shutters.

1.2 RELATED SECTIONS

1.2.1 Section 04 20 00 - Unit Masonry.

1.2.2 Section 06 10 00 - Rough Carpentry0 - Rough Carpentry; for rough opening and blocking required for installation of shutters.

1.2.3 Section 08 50 00 - Windows.

1.2.4 Section 26 00 00 - Electrical.

1.3 REFERENCES

1.3.1 AAMA 2604/05 - Voluntary Specification, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels; 1998.

1.3.2 ASTM International (ASTM):1.3.2.1 ASTM E 84 - Standard Test Method for Surface Burning Characteristics of

Building Materials.1.3.2.2 ASTM E330 - Standard Test Method for Structural Performance of Exterior

Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.

1.3.2.3 ASTM E1886, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials.

1.3.2.4 ASTM E1996, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes.

10 71 13.19-1

Page 2: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

1.3.3 European Standards (EN):1.3.3.1 EN 13125 - Shutters and Blind - Additional Thermal Resistance - Allocation of a

Class of Air Permeability to a Product.1.3.3.2 EN 13241 - Industrial, Commercial, Garage Doors and Gates - Product

Standard, Performance Characteristics.1.3.3.3 EN 13659 - Shutters and External Venetian Blinds - Performance Requirements

Including Safety.

1.3.4 Florida Building Code.

1.3.5 German National Standards (DIN)1.3.5.1 DIN 1624 - Flat Products of Steel - Cold Rolled Narrow Strip in Widths Less

Than 25.59 inch (650 mm) Of Mild Unalloyed Steels - Technical Delivery Conditions.

1.3.5.2 DIN 4108 - Thermal Protection and Energy Economy in Buildings - Part 2: Minimum Requirements to Thermal Insulation.

1.3.5.3 DIN EN ISO 12567 - Thermal performance of windows and doors -- Determination of thermal transmittance by the hot-box method -- Part 1: Complete windows and doors.

1.3.6 Metro-Dade County, FL Building Code Compliance Office Protocol:1.3.6.1 TAS 201 - Impact Test Procedures.1.3.6.2 TAS 202 - Criteria for Testing Impact and Non-Impact Resistant Building

Envelope Components Using Uniform Static Air Pressure.1.3.6.3 TAS 203 - Criteria for Testing Products Subject to Cyclic Wind Pressure

Loading.

1.3.7 Texas Building Code.

1.3.8 VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

1.4 SUBMITTALS

1.4.1 Submit under provisions of Section 01 30 00 - Administrative Requirements.

1.4.2 Product Data: Manufacturer's data sheets on each product to be used, including:1.4.2.1 Preparation instructions and recommendations.1.4.2.2 Storage and handling requirements and recommendations.1.4.2.3 Installation methods.

1.4.3 Shop Drawings: Include details of construction and relationship with adjacent construction.

1.4.4 Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) long representing actual product, color, and patterns.

1.4.5 Operating and maintenance data.

1.5 QUALITY ASSURANCE

1.5.1 Manufacturer Qualifications: Minimum 5 year experience manufacturing similar products.

1.5.2 Installer Qualifications: Minimum 2 year experience installing similar products.

1.5.3 Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.1.5.3.1 Finish areas designated by Architect.1.5.3.2 Do not proceed with remaining work until workmanship is approved by Architect.

10 71 13.19-2

Page 3: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

1.5.3.3 Remodel mock-up area as required to produce acceptable work.

1.6 PRE-INSTALLATION MEETINGS

1.6.1 Convene minimum two weeks prior to starting work of this section.

1.7 DELIVERY, STORAGE, AND HANDLING

1.7.1 Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation.

1.7.2 Handling: Handle materials to avoid damage.

1.8 PROJECT CONDITIONS

1.8.1 Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.9 SEQUENCING

1.9.1 Ensure that products of this section are supplied to affected trades in time to prevent interruption of construction progress.

1.10 WARRANTY

1.10.1 Warranty: Provide manufacturer's standard limited warranty.

2 PRODUCTS

2.1 MANUFACTURERS

2.1.1 Acceptable Manufacturer: heroal USA Inc., which is located at: 7022 TPC Dr. Suite 100; Orlando, FL 32822; Toll Free Tel: 888-437=6257; Email:request info ([email protected]); Web:https://www.heroal.de/us

2.1.2 Substitutions: Not permitted.

2.1.3 Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

2.2 EXTERIOR ROLLING SHUTTERS

2.2.1 Slats; Mini:2.2.1.1 Model RS 32: Small roller shutter slat with high level of wind resistance.

2.2.1.1.1 System Dimensions and Properties:2.2.1.1.1.1 Material: Roll-formed aluminum alloy.

2.2.1.1.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.1.1.1.1.2 Slat Fill: Polyurethane foam.2.2.1.1.1.2 Coverage Width: 1.26 inch (32 mm).2.2.1.1.1.3 Slat Thickness: 0.33 (8.5 mm).2.2.1.1.1.4 Overall Dimensions:

2.2.1.1.1.4.1 Maximum Width: 137.79 inch (3500 mm).2.2.1.1.1.4.2 Maximum Height: 137.79 inch (3500 mm).2.2.1.1.1.4.3 Maximum Area: 80.7 sq ft (7.5 sq m).

2.2.1.1.1.5 Finished Curtain Weight: 0.98 lbs per sq ft (4.8 kg per sq m).2.2.1.1.1.6 Optimized Noise Insulation: Plus 10 dB.

10 71 13.19-3

Page 4: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.2.1.1.1.7 Wind Load Resistance Class Per EN 13241: 2. With 106.3 inch (2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.2.1.1.1.8 Hail Class: 4. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.1.1.2 Design Options:2.2.1.1.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.1.1.2.2 Color: _____.2.2.1.1.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.1.1.2.4 Color: As determined by the Architect from the RAL color

selection.2.2.1.2 Model RS 37: Small roller shutter slat with high level of wind resistance.

2.2.1.2.1 System Dimensions and Properties: Design Options:2.2.1.2.1.1 Material: Roll-formed aluminum alloy.

2.2.1.2.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.1.2.1.1.2 Slat Fill: Polyurethane foam.2.2.1.2.1.2 Coverage Width: 1.46 inch (37 mm).2.2.1.2.1.3 Slat Thickness: 0.31 inch (8 mm).2.2.1.2.1.4 Overall Dimensions:

2.2.1.2.1.4.1 Maximum Width: 118.11 inch (3000 mm).2.2.1.2.1.4.2 Maximum Height: 137.79 inch (3500 mm).2.2.1.2.1.4.3 Maximum Area: 66.74 sq ft (6.2 sq m).

2.2.1.2.1.5 Finished Curtain Weight: 0.72 lbs per sq ft (3.5 kg per sq m).2.2.1.2.1.6 Optimized Noise Insulation: Plus 10 dB.2.2.1.2.1.7 Wind Load Resistance Class Per EN 13241: 1. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.2.1.2.1.8 Hail Class: 4. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.1.2.2 Design Options:2.2.1.2.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.1.2.2.2 Color: _____.2.2.1.2.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.1.2.2.4 Color: As determined by the Architect from the RAL color

selection.2.2.1.3 Model RS 38: The roller shutter for high wind loads.

2.2.1.3.1 System Dimensions and Properties:2.2.1.3.1.1 Material: Roll-formed aluminum alloy.

2.2.1.3.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.1.3.1.1.2 Slat Fill: Polyurethane foam.2.2.1.3.1.2 Coverage Width: 1.5 inch (38 mm).2.2.1.3.1.3 Slat Thickness: 0.35 inch (9 mm).2.2.1.3.1.4 Overall Dimensions:

2.2.1.3.1.4.1 Maximum Width: 145.67 inch (3700 mm).2.2.1.3.1.4.2 Maximum Height: 149.61 inch (3800 mm).2.2.1.3.1.4.3 Maximum Area: 86.11 sq ft (8.0 sq m).

2.2.1.3.1.5 Finished Curtain Weight: 0.92 lbs per sq ft (4.5 kg per sq m).2.2.1.3.1.6 Optimized noise insulation: Plus 10 dB.2.2.1.3.1.7 Wind Load Resistance Class Per EN 13241: 3. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm)

10 71 13.19-4

Page 5: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

immersion depth.2.2.1.3.1.8 Hail Class: 3. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.1.3.2 Design Options:2.2.1.3.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.1.3.2.2 Color: _____.2.2.1.3.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.1.3.2.4 Color: As determined by the Architect from the RAL color

selection.2.2.1.4 Model RS 41: Tightly wound slat with wide coverage width.

2.2.1.4.1 System Dimensions and Properties:2.2.1.4.1.1 Material: Roll-formed aluminum alloy.

2.2.1.4.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.1.4.1.1.2 Slat Fill: Polyurethane foam.2.2.1.4.1.2 Coverage width: 1.61 inch (41 mm).2.2.1.4.1.3 Slat Thickness: 0.33 inch (8.5 mm).2.2.1.4.1.4 Overall Dimensions:

2.2.1.4.1.4.1 Maximum Width: 137.79 inch (3500 mm).2.2.1.4.1.4.2 Maximum Height: 137.79 inch (3500 mm).2.2.1.4.1.4.3 Maximum Area: 75.35 sq ft (7.0 sq m).

2.2.1.4.1.5 Finished Curtain Weight: 0.76 lbs per sq ft (3.7 kg per sq m).2.2.1.4.1.6 Optimized Noise Insulation: Plus 10 dB.2.2.1.4.1.7 Wind Load Resistance Class Per EN 13241: 2. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.2.1.4.1.8 Hail Class: 4. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.1.4.2 Design Options:2.2.1.4.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.1.4.2.2 Color: _____.2.2.1.4.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.1.4.2.4 Color: As determined by the Architect from the RAL color

selection.

2.2.2 Slats; Standard:2.2.2.1 Model RS 42: Tightly wound slat with wide coverage width.

2.2.2.1.1 System Dimensions and Properties:2.2.2.1.1.1 Material: Roll-formed aluminum alloy.

2.2.2.1.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.2.1.1.1.2 Slat Fill: Polyurethane foam.2.2.2.1.1.2 Coverage Width: 1.65 inch (42 mm).2.2.2.1.1.3 Slat Thickness: 0.37 inch (9.3 mm).2.2.2.1.1.4 Overall Dimensions:

2.2.2.1.1.4.1 Maximum Width: 137.79 inch (3500 mm).2.2.2.1.1.4.2 Maximum Height: 137.79 inch (3500 mm).2.2.2.1.1.4.3 Maximum Area: 75.35 sq ft (7.0 sq m).

2.2.2.1.1.5 Finished Curtain Weight: 0.80 lbs per sq ft (3.9 kg per sq m).2.2.2.1.1.6 Optimized Noise Insulation: Plus 10 dB.2.2.2.1.1.7 Wind Load Resistance Class Per EN 13241: 2. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm)

10 71 13.19-5

Page 6: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

immersion depth.2.2.2.1.1.8 Hail Class: 3. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.2.1.2 Design Options:2.2.2.1.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.2.1.2.2 Color: _____.2.2.2.1.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.2.1.2.4 Color: As determined by the Architect from the RAL color

selection.2.2.2.2 Model RS 52: Tightly wound slat with wide coverage width.

2.2.2.2.1 System Dimensions and Properties:2.2.2.2.1.1 Material: Roll-formed aluminum alloy.

2.2.2.2.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.2.2.2.1.1.2 Slat Fill: Polyurethane foam.2.2.2.2.1.2 Coverage Width: 2.05 inch (52 mm).2.2.2.2.1.3 Slat Thickness: 0.53 inch (13.5 mm).2.2.2.2.1.4 Overall Dimensions:

2.2.2.2.1.4.1 Maximum Width: 149.61 inch (3800 mm).2.2.2.2.1.4.2 Maximum Height: 177.17 inch (4500 mm).2.2.2.2.1.4.3 Maximum Area: 75.35 sq ft (9.0 sq m).

2.2.2.2.1.5 Finished Curtain Weight: 0.82 lbs per sq ft (4.0 kg per sq m).2.2.2.2.1.6 Optimized Noise Insulation: Plus 10 dB.2.2.2.2.1.7 Wind Load Resistance Class Per EN 13241: 4. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.2.2.2.1.8 Hail Class: 5. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.2.2.2 Design Options:2.2.2.2.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.2.2.2.2 Color: _____.2.2.2.2.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.2.2.2.4 Color: As determined by the Architect from the RAL color

selection.2.2.2.3 Model RS 54: Tightly wound slat with wide coverage width.

2.2.2.3.1 System Dimensions and Properties:2.2.2.3.1.1 Material: Roll-formed aluminum alloy.

2.2.2.3.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.2.2.3.1.1.2 Slat Fill: Polyurethane foam.2.2.2.3.1.2 Coverage Width: (54 mm).2.2.2.3.1.3 Slat Thickness: 0.53 inch (13.5 mm).2.2.2.3.1.4 Overall Dimensions:

2.2.2.3.1.4.1 Maximum Width: 177.17 inch (4500 mm).2.2.2.3.1.4.2 Maximum Height: 149.61 inch (3800 mm).2.2.2.3.1.4.3 Maximum Area: 75.35 sq ft (9.0 sq m).

2.2.2.3.1.5 Finished Curtain Weight: 0.86 lbs per sq ft (4.2 kg per sq m).2.2.2.3.1.6 Optimized Noise Insulation: Plus 10 dB.2.2.2.3.1.7 Wind Load Resistance Class Per EN 13241: 4. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.2.2.3.1.8 Hail Class: 5. Per VKF (Swiss Association of Cantonal Fire

10 71 13.19-6

Page 7: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.2.2.3.2 Design Options:2.2.2.3.2.1 Highly weather-resistant surface with 2-layer thick coating.2.2.2.3.2.2 Color: _____.2.2.2.3.2.3 Color: As determined by the Architect from manufacturer's

selection.2.2.2.3.2.4 Color: As determined by the Architect from the RAL color

selection.

2.2.3 Guiderails:2.2.3.1 F2.2.3.2 LHF2.2.3.3 LHTF2.2.3.4 LHTF 402.2.3.5 HF2.2.3.6 HTF2.2.3.7 HTF 402.2.3.8 HTF-V-40 N2.2.3.9 M-HTF2.2.3.10 F-HTF 122.2.3.11 F-HTF 20

2.2.4 Enclosures; Roller Shutter Angular Profile:2.2.4.1 Material: high quality aluminum alloy. Two box ends and two panel parts.2.2.4.2 Completely external enclosures with no building cavities.2.2.4.3 No thermal bridging.2.2.4.4 No acoustical bridging.2.2.4.5 Insect Screening.2.2.4.6 Highly weather-resistant surface with 2-layer thick coating.2.2.4.7 Color: _____.2.2.4.8 Color: As determined by the Architect from manufacturer's selection.2.2.4.9 Color: As determined by the Architect from the RAL color selection.2.2.4.10 FMR 20 Degrees: Elegant angled porch panel with 20 degree slanted lower part.2.2.4.11 FMR 45 Degrees: Five-cornered porch panel with a distinctive look. With a

Greater incidence of light thanks to 45 degree slant.2.2.4.12 FMR 90 Degrees: Square porch panel with clear right-angled outline.2.2.4.13 Box Sizes: 3.94 inch (100 mm).2.2.4.14 Box Sizes: 4.92 inch (125 mm).2.2.4.15 Box Sizes: 5.39 inch (137 mm).2.2.4.16 Box Sizes: 5.91 inch (150 mm).2.2.4.17 Box Sizes: 6.50 inch (165 mm).2.2.4.18 Box Sizes: 7.09 inch (180 mm).2.2.4.19 Box Sizes: 8.07 inch (205 mm).2.2.4.20 Box Sizes: 9.06 inch (230 mm).

2.2.5 Enclosures; Roller Shutter Flush Mounting:2.2.5.1 Material: high quality aluminum alloy. Two box ends and two panel parts.2.2.5.2 Insect screen.2.2.5.3 High-quality hwr powder coating.2.2.5.4 Color: _____.2.2.5.5 Color: As determined by the Architect from manufacturer's selection.2.2.5.6 Color: As determined by the Architect from the RAL color selection.2.2.5.7 FMB 20 Degrees: Screen with 20 degrees slant.2.2.5.8 FMB 45 Degrees: Screen with 45 degrees slant.2.2.5.9 FMB 90 Degrees: Screen with 90 degrees slant.

10 71 13.19-7

Page 8: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.2.5.10 Box Sizes: 4.92 inch (125 mm).2.2.5.11 Box Sizes: 5.39 inch (137 mm).2.2.5.12 Box Sizes: 5.91 inch (150 mm).2.2.5.13 Box Sizes: 6.50 inch (165 mm).2.2.5.14 Box Sizes: 7.09 inch (180 mm).2.2.5.15 Box Sizes: 8.07 inch (205 mm).

2.2.6 Enclosures; Roller Shutter Rounded Profile:2.2.6.1 Material: high quality aluminum alloy. Two box ends and two panel parts.2.2.6.2 Wide selection of colors.2.2.6.3 Clip-on rounded attachment profiles for guide rails.2.2.6.4 Insect screen.2.2.6.5 Highly weather-resistant surface with 2-layer thick coating.2.2.6.6 Color: _____.2.2.6.7 Color: As determined by the Architect from manufacturer's selection.2.2.6.8 Color: As determined by the Architect from the RAL color selection.2.2.6.9 FMR Q: Quarter-circle porch panel system specifically for flush installation in

reveals.2.2.6.9.1 Box Sizes: 5.39 inch (137 mm).2.2.6.9.2 Box Sizes: 5.91 inch (150 mm).2.2.6.9.3 Box Sizes: 7.09 inch (180 mm).2.2.6.9.4 Box Sizes: 8.07 inch (205 mm).

2.2.6.10 FMR HC: Fully rounded porch panel system.2.2.6.10.1 Box Sizes: 5.39 inch (137 mm).2.2.6.10.2 Box Sizes: 5.91 inch (150 mm).2.2.6.10.3 Box Sizes: 6.50 inch (165 mm).2.2.6.10.4 Box Sizes: 7.09 inch (180 mm).2.2.6.10.5 Box Sizes: 8.07 inch (205 mm).

2.2.7 Motor and Controls:2.2.7.1 As recommended by manufacturer of motor and controls.2.2.7.2 Refer to the appropriate sections in Division 16 that specify motors and controls.

2.3 EXTERIOR SECURITY ROLLER SHUTTERS

2.3.1 Slats; Burglary resistant per DIN 16272.3.1.1 Model RS 37 RC 2: RC 2 security roller shutter slat with burglary resistance.

2.3.1.1.1 System Dimensions and Properties:2.3.1.1.1.1 Material: Roll-formed aluminum alloy.

2.3.1.1.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.3.1.1.1.1.2 Slat Fill: Polyurethane foam with melamin resin.2.3.1.1.1.2 Coverage Width: 1.46 inches (37 mm).2.3.1.1.1.3 Slat Thickness: 0.37 inch (9.5 mm).2.3.1.1.1.4 Overall Dimensions:

2.3.1.1.1.4.1 Maximum Width: 165.35 inch (4200 mm).2.3.1.1.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.1.1.1.4.3 Maximum Area: 113 sq ft (10.5 sq m).

2.3.1.1.1.5 Finished Curtain Weight: 1.80 lbs per sq ft (8.8 kg per sq m).2.3.1.1.1.6 Optimized Noise Insulation: Plus 10 dB Design.2.3.1.1.1.7 Wind Load Resistance Class Per EN 13241: 4. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.1.1.1.8 Burglary Resistance: RC 2 per DIN 1627.2.3.1.1.1.9 Hail Class: 7. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value

10 71 13.19-8

Page 9: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

reflects the mechanical functional capability.2.3.1.1.2 Design Options:

2.3.1.1.2.1 Highly weather-resistant surface with 2-layer thick coating.2.3.1.1.2.2 Color: _____.2.3.1.1.2.3 Color: As determined by the Architect from manufacturer's

selection.2.3.1.1.2.4 Color: As determined by the Architect from the RAL color

selection.2.3.1.2 Model RS 37 RC 3:

2.3.1.2.1 System Dimensions and Properties:2.3.1.2.1.1 Material: Stainless steel.

2.3.1.2.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.3.1.2.1.1.2 Slat Fill: Durable two-component composite material.2.3.1.2.1.2 Coverage Width: 1.46 inches (37 mm).2.3.1.2.1.3 Slat Thickness: 0.37 inch (9.5 mm).2.3.1.2.1.4 Overall Dimensions:

2.3.1.2.1.4.1 Maximum Width: 196.85 inch (5000 mm).2.3.1.2.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.1.2.1.4.3 Maximum Area: 129.17 sq ft (12.0 sq m).

2.3.1.2.1.5 Finished Curtain Weight: 2.87 lbs per sq ft (14.0 kg per sq m).2.3.1.2.1.6 Optimized Noise Insulation: Plus 10 dB.2.3.1.2.1.7 Wind Load Resistance Class Per EN 13241: 6. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.1.2.1.8 Resistance Class: RC 2 Per DIN 1627.2.3.1.2.1.9 Resistance Class: Up to RC 3 Per DIN 1627.2.3.1.2.1.10 Hail Class: 7. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.3.1.3 Model RS 53 RC 2 (Cat. D): Highly durable and secure due to 14 mm nominal thickness.

2.3.1.3.1 System Dimensions and Properties:2.3.1.3.1.1 Material: Roll-formed aluminum alloy.

2.3.1.3.1.1.1 Roll-Formed Wall Thickness: As standard with manufacturer.

2.3.1.3.1.1.2 Slat Fill: Polyurethane foam with melamin resin.2.3.1.3.1.2 Coverage Width: 2 inches (51 mm).2.3.1.3.1.3 Slat Thickness: 0.55 inch (14 mm).2.3.1.3.1.4 Overall Dimensions:

2.3.1.3.1.4.1 Maximum Width: 216.53 inch (5500 mm).2.3.1.3.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.1.3.1.4.3 Maximum Area: 177.60 sq ft (16.5 sq m).

2.3.1.3.1.5 Finished Curtain Weight: 2.15 lbs per sq ft (10.5 kg per sq m).2.3.1.3.1.6 Optimized Noise Insulation: Plus 10 dB.2.3.1.3.1.7 Wind Load Resistance Class Per EN 13241: 6. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.1.3.1.8 Enhanced Burglary Resistance: RC 2 Per DIN 1627.2.3.1.3.1.9 Hail Class: 7. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.3.1.3.2 Design Options:2.3.1.3.2.1 Highly weather-resistant surface with 2-layer thick coating.2.3.1.3.2.2 Color: _____.2.3.1.3.2.3 Color: As determined by the Architect from manufacturer's

10 71 13.19-9

Page 10: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

selection.2.3.1.3.2.4 Color: As determined by the Architect from the RAL color

selection.2.3.1.4 Model RS 53 RC 3 (Cat. E): Extremely high resistance level.

2.3.1.4.1 System Dimensions and Properties:2.3.1.4.1.1 Material: Stainless steel.

2.3.1.4.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.3.1.4.1.1.2 Slat Fill: Heavy-duty two-component composite material.2.3.1.4.1.2 Coverage Width: 2 inches (51 mm).2.3.1.4.1.3 Slat Thickness: 0.55 inch (14 mm).2.3.1.4.1.4 Overall Dimensions:

2.3.1.4.1.4.1 Maximum Width: 236.22 inch (6000 mm).2.3.1.4.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.1.4.1.4.3 Maximum Area: 193.75 sq ft (18.0 sq m).

2.3.1.4.1.5 Finished Curtain Weight: 3.69 lbs per sq ft (18.0 kg per sq m).2.3.1.4.1.6 Optimized Noise Insulation: Plus 10 dB.2.3.1.4.1.7 Wind Load Resistance Class Per EN 13241: 6. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.1.4.1.8 Available Resistance Class: Up to RC 3 Per DIN 1627.2.3.1.4.1.9 Hail Class: 7. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.3.2 Enclosures; Burglary resistant per DIN 1627:2.3.2.1 Model: FMS 45 Degrees:2.3.2.2 Material: high quality aluminum alloy. Two box ends and two panel parts.

2.3.2.2.1 Wall Thicknesses: 1/8 inch (3 mm) thick minimum.2.3.2.2.2 Lower panel beveled at a 45 degree angle.

2.3.2.3 Extruded panel system made from high quality aluminum alloy.2.3.2.4 Resistance Class: RC2.2.3.2.5 Resistance Class: RC3.2.3.2.6 Security lock.2.3.2.7 Box Size: 8.07 inch (205 mm).2.3.2.8 High-quality hwr powder coating.2.3.2.9 Color: _____.2.3.2.10 Color: As determined by the Architect from manufacturer's selection.2.3.2.11 Color: As determined by the Architect from the RAL color selection.

2.3.3 Slats; Burglary resistant per the technical directive TR 111 from the BVRS (German federal association for manufacturers of roller shutters and sun protection).2.3.3.1 Model RS 37 SL: Security roller shutter slat with burglary resistance.

2.3.3.1.1 System Dimensions and Properties:2.3.3.1.1.1 Material: Roll-formed aluminum alloy.

2.3.3.1.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.3.3.1.1.1.2 Slat Fill: Polyurethane foam.2.3.3.1.1.2 Coverage Width: 1.46 inches (37 mm).2.3.3.1.1.3 Slat Thickness: 0.38 inch (9.5 mm).2.3.3.1.1.4 Overall Dimensions:

2.3.3.1.1.4.1 Maximum Width: 157.48 inch (4000 mm).2.3.3.1.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.3.1.1.4.3 Maximum Area: 66.74 sq ft (9.0 sq m).

2.3.3.1.1.5 Maximum Width x Height: 157.48 x 157.48 inches (4000 x 4000 mm).

10 71 13.19-10

Page 11: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.3.3.1.1.6 Maximum Area: 96.88 sq ft (9.0 sq m).2.3.3.1.1.7 Finished Curtain Weight: 1.21 lbs per sq ft (5.9 kg per sq m).2.3.3.1.1.8 Optimized Noise Insulation: Plus 10 dB.2.3.3.1.1.9 Wind Load Resistance Class Per EN 13241: 4. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.3.1.1.10 Burglary Resistance: In accordance with technical directive TR 111 from the BVRS (German federal association for manufacturers of roller shutters and sun protection).

2.3.3.1.1.11 Hail Class: 5. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.3.3.1.2 Design Options:2.3.3.1.2.1 Elegant slat design.2.3.3.1.2.2 Highly weather-resistant surface with 2-layer thick coating.2.3.3.1.2.3 Color: _____.2.3.3.1.2.4 Color: As determined by the Architect from manufacturer's

selection.2.3.3.1.2.5 Color: As determined by the Architect from the RAL color

selection.2.3.3.2 Model RS 55 SL: Security roller shutter slat with burglary resistance.

2.3.3.2.1 System Dimensions and Properties:2.3.3.2.1.1 Material: Roll-formed aluminum alloy.

2.3.3.2.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.3.3.2.1.1.2 Slat Fill: Polyurethane foam.2.3.3.2.1.2 Coverage Width: 2.16 inches (55 mm).2.3.3.2.1.3 Slat Thickness: 0.55 inch (14 mm).2.3.3.2.1.4 Overall Dimensions:

2.3.3.2.1.4.1 Maximum Width: 196.85 inch (5000 mm).2.3.3.2.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.3.3.2.1.4.3 Maximum Area: 66.74 sq ft (12.0 sq m).

2.3.3.2.1.5 Finished Curtain Weight: 1.02 lbs per sq ft (5.0 kg per sq m)2.3.3.2.1.6 Optimized Noise Insulation: Plus 10 dB Design.2.3.3.2.1.7 Wind Load Resistance Class Per EN 13241: 5. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.3.3.2.1.8 Burglary Resistance: In accordance with technical directive TR 111 from the BVRS (German federal association for manufacturers of roller shutters and sun protection).

2.3.3.2.1.9 Hail Class: 5. Per VKF (Swiss Association of Cantonal Fire Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.3.3.2.2 Design Options:2.3.3.2.2.1 Used in Roller Shutters or Roller Doors.2.3.3.2.2.2 Elegant slat design.2.3.3.2.2.3 Highly weather-resistant surface with 2-layer thick coating.2.3.3.2.2.4 Color: _____.2.3.3.2.2.5 Color: As determined by the Architect from manufacturer's

selection.2.3.3.2.2.6 Color: As determined by the Architect from the RAL color

selection.

2.3.4 Enclosures; Burglary Resistant per the Technical Directive TR 111 from the BVRS (German federal association for manufacturers of roller shutters and sun protection).2.3.4.1 General:

10 71 13.19-11

Page 12: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.3.4.1.1 Material: High quality aluminum alloy. Two box ends and two panel parts.2.3.4.1.2 Insect screen.2.3.4.1.3 High-quality hwr powder coating.2.3.4.1.4 Color: _____.2.3.4.1.5 Color: As determined by the Architect from manufacturer's selection.2.3.4.1.6 Color: As determined by the Architect from the RAL color selection.

2.3.4.2 Model FME 20: Elegant angled, extruded porch panel with 20 degree slant.2.3.4.3 Model FME 45: Distinctive, extruded porch panel with 45 degree slant.2.3.4.4 Model FME 90: Square, extruded porch panel with clear right-angled outline.2.3.4.5 Model FME HC: Full half-circle rounded profile.

2.3.4.5.1 Clip-on rounded attachment profiles for guide rails.2.3.4.6 Box Sizes: 3.94 inch (100 mm) (only FME 45).2.3.4.7 Box Sizes: 4.92 inch (125 mm).2.3.4.8 Box Sizes: 5.39 inch (137 mm).2.3.4.9 Box Sizes: 5.91 inch (150 mm).2.3.4.10 Box Sizes: 6.50 inch (165 mm).2.3.4.11 Box Sizes: 7.09 inch (180 mm).2.3.4.12 Box Sizes: 8.07 inch (205 mm).

2.3.5 Motor and Controls:2.3.5.1 As recommended by manufacturer of motor and controls.2.3.5.2 Refer to the appropriate sections in Division 16 that specify motors and controls.

2.4 EXTERIOR HURRICANE ROLLER SHUTTERS

2.4.1 Performance Requirements:2.4.1.1 Florida Building Code - High Velocity Hurricane Zone.2.4.1.2 Texas Dept. of Insurance, TAS 201, TAS 202, and TAS 203.2.4.1.3 Tested per the Following:

2.4.1.3.1 ASTM E330.2.4.1.3.2 ASTM E1886.2.4.1.3.3 ASTM E1996.

2.4.2 Slats; Hurricane Roller Shutters:2.4.2.1 Model RS 53 RC 2 (Cat. D): Highly durable and secure due to 14 mm nominal

thickness.2.4.2.1.1 System Dimensions and Properties:

2.4.2.1.1.1 Material: Extruded aluminum alloy.2.4.2.1.1.1.1 Roll-formed Wall Thickness: As standard with

manufacturer.2.4.2.1.1.1.2 Slat Fill: Polyurethane foam with melamin resin.

2.4.2.1.1.2 Coverage Width: 2 inches (51 mm).2.4.2.1.1.3 Slat Thickness: 0.55 inch (14 mm).2.4.2.1.1.4 Overall Dimensions:

2.4.2.1.1.4.1 Maximum Width: 216.53 inch (5500 mm).2.4.2.1.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.4.2.1.1.4.3 Maximum Area: 177.60 sq ft (16.5 sq m).

2.4.2.1.1.5 Finished Curtain Weight: 2.15 lbs per sq ft (10.5 kg per sq m).2.4.2.1.1.6 Optimized Noise Insulation: Plus 10 dB.2.4.2.1.1.7 Wind Load Resistance Class Per EN 13241: 6. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.4.2.1.1.8 Enhanced Burglary Resistance: RC 2 Per DIN 1627.2.4.2.1.1.9 Hail Class: 6. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

10 71 13.19-12

Page 13: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.4.2.1.2 Design Options:2.4.2.1.2.1 Highly weather-resistant surface with 2-layer thick coating.2.4.2.1.2.2 Color: _____.2.4.2.1.2.3 Color: As determined by the Architect from manufacturer's

selection.2.4.2.1.2.4 Color: As determined by the Architect from the RAL color

selection.2.4.2.2 Model RS 53 RC 3 (Cat. E): Extremely high resistance level.

2.4.2.2.1 System Dimensions and Properties:2.4.2.2.1.1 Material: High-grade steel alloy.

2.4.2.2.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.4.2.2.1.1.2 Slat Fill: Polyurethane foam.2.4.2.2.1.2 Coverage Width: 2 inches (51 mm).2.4.2.2.1.3 Slat Thickness: 0.55 inch (14 mm).2.4.2.2.1.4 Overall Dimensions:

2.4.2.2.1.4.1 Maximum Width: 236.22 inch (6000 mm).2.4.2.2.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.4.2.2.1.4.3 Maximum Area: 193.75 sq ft (18.0 sq m).

2.4.2.2.1.5 Finished Curtain Weight: 3.69 lbs per sq ft (18.0 kg per sq m).2.4.2.2.1.6 Optimized Noise Insulation: Plus 10 dB.2.4.2.2.1.7 Wind Load Resistance Class Per EN 13241: 6. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.4.2.2.1.8 Available Resistance Class: Up to RC 3 Per DIN 1627.2.4.2.2.1.9 Hail Class: 7. Per VKF (Swiss Association of Cantonal Fire

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.4.2.2.2 Design Option:2.4.2.2.2.1 Highly weather-resistant surface with 2-layer thick coating.2.4.2.2.2.2 Color: _____.2.4.2.2.2.3 Color: As determined by the Architect from manufacturer's

selection.2.4.2.2.2.4 Color: As determined by the Architect from the RAL color

selection.2.4.2.3 Model RS 55 SL: Security roller shutter slat with burglary resistance.

2.4.2.3.1 System Dimensions and Properties:2.4.2.3.1.1 Material: Extruded aluminum alloy.

2.4.2.3.1.1.1 Roll-formed Wall Thickness: As standard with manufacturer.

2.4.2.3.1.1.2 Slat Fill: Polyurethane foam.2.4.2.3.1.2 Coverage Width: 2.16 inches (55 mm).2.4.2.3.1.3 Slat Thickness: 0.55 inch (14 mm).2.4.2.3.1.4 Overall Dimensions:

2.4.2.3.1.4.1 Maximum Width: 196.85 inch (5000 mm).2.4.2.3.1.4.2 Maximum Height: 157.48 inch (4000 mm).2.4.2.3.1.4.3 Maximum Area: 66.74 sq ft (12.0 sq m).

2.4.2.3.1.5 Finished Curtain Weight: 1.11 lbs per sq ft (5.4 kg per sq m).2.4.2.3.1.6 Optimized Noise Insulation: Plus 10 dB.2.4.2.3.1.7 Wind Load Resistance Class Per EN 13241: 5. With 106.3 inch

(2700 mm) element width and a guide with 1 inch (25 mm) immersion depth.

2.4.2.3.1.8 Burglary Resistance: In accordance with technical directive TR 111 from the BVRS (German federal association for manufacturers of roller shutters and sun protection).

2.4.2.3.1.9 Hail Class: 5. Per VKF (Swiss Association of Cantonal Fire

10 71 13.19-13

Page 14: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

Insurance Companies) Test Specifications No. 02. The value reflects the mechanical functional capability.

2.4.2.3.2 Design Options:2.4.2.3.2.1 Used in Roller Shutters or Roller Doors.2.4.2.3.2.2 Elegant slat design.2.4.2.3.2.3 Highly weather-resistant surface with 2-layer thick coating.2.4.2.3.2.4 Color: _____.2.4.2.3.2.5 Color: As determined by the Architect from manufacturer's

selection.2.4.2.3.2.6 Color: As determined by the Architect from the RAL color

selection.

2.4.3 Enclosures; Hurricane Resistant:2.4.3.1 Model GKSE:

2.4.3.1.1 Material: high quality aluminum alloy. Two box ends and two panel parts.2.4.3.1.1.1 Wall Thicknesses: 1/8 inch (3 mm) thick minimum.2.4.3.1.1.2 Lower panel elegantly beveled at a 45 degree angle.

2.4.3.1.2 Hurricane, burglar, and weather resistant.2.4.3.1.3 Security: Watertight closure of the inspection cover in the upper area.

2.4.3.1.3.1 Security lock.2.4.3.1.4 Soundproofing: Reduces the noise levels caused by the winding process,

as opposed to boxless installation.2.4.3.1.5 Box Ends: Powder coated Aluminum die castings.2.4.3.1.6 High-quality hwr powder coating.2.4.3.1.7 Color: _____.2.4.3.1.8 Color: As determined by the Architect from manufacturer's selection.2.4.3.1.9 Color: As determined by the Architect from the RAL color selection.

2.4.3.2 Box Size: 8 inch (203 mm).2.4.3.3 Box Size: 9 inch (229 mm).2.4.3.4 Box Size: 10 inch (254 mm).2.4.3.5 Box Size: 11.8 inch (300 mm).

2.4.4 Motor and Controls:2.4.4.1 As recommended by manufacturer of motor and controls.2.4.4.2 Refer to the appropriate sections in Division 16 that specify motors and controls.

2.4.5 Accessories:2.4.5.1 End Slats: Heavy-duty and forms a tight seal.

2.4.5.1.1 Energy Saving: Tightly closing end slats provide thermal insulation and therefore savings on energy costs.

2.4.5.1.2 Security:2.4.5.1.2.1 Heavy-duty, extruded aluminum end slats.2.4.5.1.2.2 Unhindered winding up of curtain thanks to backstop function.2.4.5.1.2.3 Security option: possibility to slide in flat steel Soundproofing.

2.4.5.1.3 Soundproofing: Optimized noise insulation: Plus 10 dB.2.4.5.1.4 Design:

2.4.5.1.4.1 Hidden backstop.2.4.5.1.4.2 Stopping block.2.4.5.1.4.3 Backstop with angled end slat.

2.4.5.1.5 Finish:2.4.5.1.5.1 High-quality hwr powder coating.2.4.5.1.5.2 Color: _____.2.4.5.1.5.3 Color: As selected by the Architect from manufacturer's wide

selection.2.4.5.1.5.4 Color: As determined by the Architect from the RAL color

selection.

10 71 13.19-14

Page 15: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

2.4.5.2 Guide Rails:2.4.5.2.1 Energy Saving: Guide rails prevent thermal bridges between roller shutters

and window frames, and the associated energy losses.2.4.5.2.2 Security:

2.4.5.2.2.1 Particularly durable, extruded aluminum guide rails.2.4.5.2.2.2 Reliable curtain movement thanks to rolled-in weather strip made

from hard and soft PVC or brush inserts.2.4.5.2.2.3 Durable curtain frame.

2.4.5.2.3 Soundproofing: Quiet curtain operation.2.4.5.2.4 Design:

2.4.5.2.4.1 Design flexibility thanks to extensive range of variants.2.4.5.2.4.2 Design variants for integrated insect screen.

2.4.5.2.5 Finish:2.4.5.2.5.1 High-quality hwr powder coating.2.4.5.2.5.2 Color: _____.2.4.5.2.5.3 Color: As selected by the Architect from manufacturer's wide

selection.2.4.5.2.5.4 Color: As determined by the Architect from the RAL color

selection.

3 EXECUTION

3.1 EXAMINATION

3.1.1 Do not begin installation until substrates have been properly prepared.

3.1.2 If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.

3.2 PREPARATION

3.2.1 Clean surfaces thoroughly prior to installation.

3.2.2 Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

3.3 INSTALLATION

3.3.1 Install in accordance with manufacturer's instructions, approved submittals and in proper relationship with adjacent construction.

3.3.2 Test for proper operation and adjust until satisfactory results are achieved.

3.4 FIELD QUALITY CONTROL

3.4.1 Test for proper operation and adjust until satisfactory results are obtained.

3.5 PROTECTION

3.5.1 Protect installed products until completion of project.

3.5.2 Touch-up, repair or replace damaged products before Substantial Completion.

3.6 PRODUCT MAINTENANCE AND USE

3.6.1 Proper maintenance measures shall be taken to ensure a long life for the shutter product. The following cleaning conditions shall be met to qualify for product warranty consideration:3.6.1.1 Documented cleaning, two times per calendar year.

10 71 13.19-15

Page 16: ARCAT · Web viewEXTERIOR HURRICANE ROLLER SHUTTERS Performance Requirements: Florida Building Code - High Velocity Hurricane Zone. Texas Dept. of Insurance, TAS 201, TAS 202, and

3.6.1.2 Mild alkaline detergent and clean water wash.3.6.1.3 Effect may be increased by rubbing with a soft, non-scratch cotton cloth.3.6.1.4 Temperature of parts should not exceed 80 degrees F (26.7 degrees C) during

cleaning.3.6.1.5 Use only isopropyl alcohol for removal of grease or oily substances.3.6.1.6 Cleaning solution must not be allowed to react for more than one hour.3.6.1.7 After cleaning, all surfaces should be thoroughly rinsed with clean, cold water.3.6.1.8 Thoroughly cleaned and lubricated yearly to maintain smooth, trouble free

operation.

END OF SECTION

10 71 13.19-16