apus manual

40
GENEX Apus User Manual Table of Contents i Table of Contents Chapter 1 Introduction to the Apus ............................................................................................. 1-1 Chapter 2 Software Installation.................................................................................................... 2-1 2.1 Overview ............................................................................................................................ 2-1 2.2 Installing the Apus ............................................................................................................. 2-1 2.3 Registering the Apus ......................................................................................................... 2-1 Chapter 3 Software Interfaces...................................................................................................... 3-1 3.1 Overview ............................................................................................................................ 3-1 3.2 Introduction to the Main Software Interface ....................................................................... 3-1 3.3 Editing an Interface Area ................................................................................................... 3-2 Chapter 4 Engineering Project Management .............................................................................. 4-1 4.1 Overview ............................................................................................................................ 4-1 4.2 Creating a Project .............................................................................................................. 4-1 4.3 Opening a Project .............................................................................................................. 4-2 4.4 Closing a Project ................................................................................................................ 4-2 Chapter 5 Engineering Parameter Management ........................................................................ 5-1 5.1 Overview ............................................................................................................................ 5-1 5.2 Importing the Engineering Parameters .............................................................................. 5-1 5.3 Exporting the Engineering Parameters.............................................................................. 5-5 5.4 Setting a Map File .............................................................................................................. 5-6 5.5 Setting an Antenna ............................................................................................................ 5-6 Chapter 6 Editing Engineering Parameter .................................................................................. 6-1 6.1 Overview ............................................................................................................................ 6-1 6.2 Enabling an Engineering Parameter Editor ....................................................................... 6-1 6.3 Adding an NE..................................................................................................................... 6-2 6.3.1 Adding a BTS .......................................................................................................... 6-2 6.3.2 Adding a Cell ........................................................................................................... 6-4 6.3.3 Adding a Sector ....................................................................................................... 6-4 6.3.4 Adding a Carrier ...................................................................................................... 6-6 6.4 Deleting an NE................................................................................................................... 6-6 6.5 Modifying an NE Property .................................................................................................. 6-7 6.6 Using a Map Tool ............................................................................................................... 6-7 6.6.1 Map Toolbar ............................................................................................................ 6-7 6.6.2 Searching for an NE on the Map............................................................................. 6-8 6.6.3 Modifying a Map Label ............................................................................................ 6-8 Chapter 7 Automatic Neighbor Planning .................................................................................... 7-1 7.1 Overview ............................................................................................................................ 7-1

Upload: tahir-muneer

Post on 28-Apr-2015

101 views

Category:

Documents


6 download

DESCRIPTION

Huawei

TRANSCRIPT

Page 1: Apus manual

GENEX Apus User Manual Table of Contents

i

Table of Contents

Chapter 1 Introduction to the Apus............................................................................................. 1-1

Chapter 2 Software Installation.................................................................................................... 2-1 2.1 Overview............................................................................................................................ 2-1 2.2 Installing the Apus ............................................................................................................. 2-1 2.3 Registering the Apus ......................................................................................................... 2-1

Chapter 3 Software Interfaces...................................................................................................... 3-1 3.1 Overview............................................................................................................................ 3-1 3.2 Introduction to the Main Software Interface....................................................................... 3-1 3.3 Editing an Interface Area ................................................................................................... 3-2

Chapter 4 Engineering Project Management.............................................................................. 4-1 4.1 Overview............................................................................................................................ 4-1 4.2 Creating a Project .............................................................................................................. 4-1 4.3 Opening a Project .............................................................................................................. 4-2 4.4 Closing a Project................................................................................................................ 4-2

Chapter 5 Engineering Parameter Management ........................................................................ 5-1 5.1 Overview............................................................................................................................ 5-1 5.2 Importing the Engineering Parameters.............................................................................. 5-1 5.3 Exporting the Engineering Parameters.............................................................................. 5-5 5.4 Setting a Map File.............................................................................................................. 5-6 5.5 Setting an Antenna ............................................................................................................ 5-6

Chapter 6 Editing Engineering Parameter .................................................................................. 6-1 6.1 Overview............................................................................................................................ 6-1 6.2 Enabling an Engineering Parameter Editor ....................................................................... 6-1 6.3 Adding an NE..................................................................................................................... 6-2

6.3.1 Adding a BTS .......................................................................................................... 6-2 6.3.2 Adding a Cell ........................................................................................................... 6-4 6.3.3 Adding a Sector....................................................................................................... 6-4 6.3.4 Adding a Carrier ...................................................................................................... 6-6

6.4 Deleting an NE................................................................................................................... 6-6 6.5 Modifying an NE Property.................................................................................................. 6-7 6.6 Using a Map Tool............................................................................................................... 6-7

6.6.1 Map Toolbar ............................................................................................................ 6-7 6.6.2 Searching for an NE on the Map............................................................................. 6-8 6.6.3 Modifying a Map Label ............................................................................................ 6-8

Chapter 7 Automatic Neighbor Planning .................................................................................... 7-1 7.1 Overview............................................................................................................................ 7-1

Page 2: Apus manual

GENEX Apus User Manual Table of Contents

ii

7.2 Enabling the Neighbor Planning ........................................................................................ 7-1 7.3 Executing the Neighbor Planning ...................................................................................... 7-2 7.4 Checking the Neighbor Planning Result ............................................................................ 7-4

7.4.1 Checking the Neighbor Result ................................................................................ 7-4 7.4.2 Checking the Result on the Map............................................................................. 7-5

7.5 Adjusting the Neighbors..................................................................................................... 7-6 7.5.1 Adjusting the Neighbor Relationship....................................................................... 7-6 7.5.2 Adjusting the Neighbor Priority................................................................................ 7-7

7.6 Auditing the Neighbors ...................................................................................................... 7-7 7.7 Importing the Neighbor data .............................................................................................. 7-8 7.8 Exporting the Neighbor Adjustment Script......................................................................... 7-9

Chapter 8 Automatic PN Planning............................................................................................... 8-1 8.1 Overview............................................................................................................................ 8-1 8.2 Enabling the PN Planning.................................................................................................. 8-1 8.3 Setting a Single Carrier PN Property................................................................................. 8-1 8.4 Executing the PN Planning ................................................................................................ 8-2 8.5 Checking the PN Planning Result...................................................................................... 8-4

8.5.1 Checking the PN Planning Table ............................................................................ 8-4 8.5.2 Checking the Cluster or Sub-cluster Allocation Result ........................................... 8-4

8.6 Checking the PN Reuse .................................................................................................... 8-5 8.7 Exporting the PN Planning Result ..................................................................................... 8-6

Page 3: Apus manual

GENEX Apus User Manual Chapter 1 Introduction to the Apus

1-1

Chapter 1 Introduction to the Apus

The Apus for automatic neighbor and PN offsets planning enables the following functions in the CDMA2000 network.

Network element (NE) management - Importing the existing NE data - Generating and modifying the NE data - Displaying the NE data on the map

Note:

The NEs include the followings: Site Sector Cell

Setting the network engineering parameters - Setting the antenna data - Setting the propagation model

Automatic neighbor and PN offsets planning and optimization - Automatic planning for the neighbors and the PN offsets - Checking the neighbors and the PN offsets of the existing network

Generating the BAM neighbor adjustment script automatically - Exporting the neighbor adjustment scripts - Adjusting the neighbor configuration by OMC

Page 4: Apus manual

GENEX Apus User Manual Chapter 2 Software Installation

2-1

Chapter 2 Software Installation

2.1 Overview

This chapter describes the followings:

Installing the Apus Registering the Apus

2.2 Installing the Apus

Note:

Ensure that the GENEX Apus and the GENEX Shared are in the same directory before installation.

To install the Apus software, proceed as follows:

1) Enter the GENEX Apus directory and double click the Setup.exe. The dialog box GENEX Apus – InstallShield Wizard is displayed.

2) Define the installation directory and installation type as per the suggestions during the software installation.

3) After the installation, click Finish. The GENEX Shared Installation interface is displayed.

4) Install the GENEX Shared as per the suggestions. 5) After the installation, click Finish.

The Apus software installation is complete.

2.3 Registering the Apus

To register the Apus, proceed as follows:

1) Open the Start > Program > GENEX Apus menu and run Apus 1.0. An interface is displayed, as Figure 2-1 shows.

Page 5: Apus manual

GENEX Apus User Manual Chapter 2 Software Installation

2-2

Figure 2-1 Prompt for license error

Note:

If the License Code.lic file is already available for you, go to step 3).

2) Submit the equipment sequence number (ESN) in the License Error dialog box to Huawei Technologies Co., LTD (Hereafter, Huawei Company) to get the License Code.lic.

3) In the License Error dialog box, click Update. 4) Choose the License Code.lic file in the open dialog box to register. 5) After the registration, click Close.

The Apus is operational after registration.

Page 6: Apus manual

GENEX Apus User Manual Chapter 3 Software Interfaces

3-1

Chapter 3 Software Interfaces

3.1 Overview

This chapter profiles the followings:

Introduction to the Main Software Interface Editing an Interface Area

3.2 Introduction to the Main Software Interface

Figure 3-1 shows the main software interface.

Figure 3-1 Main software interface

Table 3-1 lists the main functions of the interface.

Table 3-1 Area functions

Area Function description

Menu bar To set the specific parameters

Toolbar To operate the engineering files

Page 7: Apus manual

GENEX Apus User Manual Chapter 3 Software Interfaces

3-2

Area Function description

Functional area To check the NE data

To start the planning

Editing area To edit the NE parameters geographically

Task pane To provide shortcuts for the common tasks

Event viewer To check the software calculation procedures

3.3 Editing an Interface Area

To display or hide some of the interface areas in the Apus, proceed as follows:

1) Right click on the menu bar or on the toolbar. A shortcut menu is displayed, as Figure 3-2 shows.

Figure 3-2 Selection menu

2) Display or hide an interface area by selecting or clearing the associated option.

Page 8: Apus manual

GENEX Apus User Manual Chapter 4 Engineering Project Management

4-1

Chapter 4 Engineering Project Management

4.1 Overview

The engineering project management includes:

Creating a Project Opening a Project Closing a Project

4.2 Creating a Project

To create a project, proceed as follows:

1) Choose File > New, or click on the toolbar.

2) In the Create Project dialog box, do as Figure 4-1 lists.

Table 4-1 Operations in the project creation

Area selection Operation

In the Version List box

Click the associated BAM version.

In the New Project box

1) Click .

2) Define the path and the name for the new project in the Save As dialog box.

Note:

The Apus exports various neighbor adjustment scripts as per different BAM versions. For details concerning neighbor adjustment, refer to 7.8 “Exporting the Neighbor Adjustment Script”.

3) Click OK. Figure 4-1 shows the navigation tree in the function area.

Page 9: Apus manual

GENEX Apus User Manual Chapter 4 Engineering Project Management

4-2

Figure 4-1 Engineering navigation tree

4.3 Opening a Project

To open a project, proceed as follows:

1) Choose File > Open. Or click on the toolbar.

2) Choose the .apu engineering file in the open window. 3) Click Open.

Figure 4-1 shows the navigation tree after the project is open.

4.4 Closing a Project

Two ways are available to close the current project.

Choose File > Close to close the project.

Click on the toolbar.

Page 10: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-1

Chapter 5 Engineering Parameter Management

5.1 Overview

The engineering parameter management includes:

Importing the Engineering Parameter Exporting the Engineering Parameter Setting a Map File Setting an Antenna

5.2 Importing the Engineering Parameters

The engineering parameter is the network data for neighbor planning or PN planning. The following data are essential:

BTS name Longitude BTSID Sector ID Cell ID ARFCN Antenna type Azimuth

Note:

The above data can be obtained from the equipment operator.

The Apus imports the engineering parameter in Excel. Before importing, ensure that:

The engineering parameter table contains the essential parameters listed above. The engineering parameter table contains no diagrams, formulas or links to the

other worksheets. The BTSID is written correctly, since it is used to generate the neighbor scripts. If

you do not need to create the neighbor scripts, fill in with the distinguished values.

To import the engineering parameters, proceed as follows:

1) Choose Data manager > Import Engineering Parameter. 2) In the open Import Engineering Parameter dialog box, proceed as Table 5-1

lists.

Page 11: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-2

Table 5-1 Operations in the import of the engineering parameter

Area selection Operation

In the Excel File box 1) Click .

2) In the open dialog box, choose the Excel file containing the engineering parameter.

In the BSC IP box Enter the actual IP address of the BSC.

Note:

The BSC IP address is used for exporting the neighbor script. If this feature is unnecessary for you, you only need to enter a valid IP address.

3) Click OK. 4) If some worksheets are contained in the Excel, the Select Sheet dialog box is

displayed, as Figure 5-1 shows.

Figure 5-1 Selecting worksheets

5) Choose the worksheet that contains the required parameters. 6) Click OK. A window is displayed, as Figure 5-2 shows.

Page 12: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-3

Figure 5-2 Matching data

Note:

The Apus sets the automatic matching fields in orange color.

For details concerning data matching, refer to Table 5-2.

Table 5-2 Data matching operation

Icon Function Operation

To set the title bar

1) Select the title row.

2) Click . This row becomes title.

Note: The automatic matching is performed

based on the information listed in the title.

The titles that are successfully matched show in orange.

To match the fields automatically

Match the selected information automatically and set them as the title.

Page 13: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-4

Icon Function Operation

To indicate the matched fields

Click the matched column in the table. On

the right of shows the field name.

To cancel the matched column

1) Select the matched column.

2) Click to cancel the selected

column.

To cancel all the matched columns

Click to cancel all the matched

columns.

To import the data Click to import the data.

7) Right-click the columns that are not matched. Choose the field names in the Required field and Optional field until the wanted parameters and the required fields are all matched.

8) Click to import the data. The Apus reads the data and checks the matched

fields automatically. If the type is incorrect, the system gives a prompt, indicating wrong type and shows the error cell in red.

9) After data correction, click for the second time to complete the data import.

The data is added into the navigation tree, as Figure 5-3 shows.

Page 14: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-5

Figure 5-3 Engineering parameter list

5.3 Exporting the Engineering Parameters

Two kinds of the engineering parameters are ready for export. They are:

Current engineering parameter Refers to the imported engineering parameters during project creation.

Modified engineering parameter Refers to the information after the engineering parameters have been modified. For details about the engineering parameter modification, refer to Chapter 6 “Editing Engineering Parameter ”.

To export the engineering parameter, proceed as follows:

1) Choose the Data Manager > Export Current Parameter (Export Modified Parameter).

2) In the Export Engineering Parameter dialog box, do as Table 5-3 lists.

Table 5-3 Exporting the engineering parameters

Area selection Operation

In the BSC List box Choose the BSC data to be exported.

In the Save as box 1) Click .

2) Define the name and the path for the file to be exported.

Page 15: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-6

3) Click OK.

5.4 Setting a Map File

By default, the Apus considers the .gst supported by MapInfo as the map file.

To set the map file, proceed as follows:

1) Choose System > Map path setting.

2) Click in the Map Path Setting dialog box.

3) Set the open map file.

Note:

If only the .tab supported by MapInfo is available, you are allowed to select one or several .tab files in the Map Path Selection, since the Apus informs you of saving them as .gst.

4) Click OK.

5.5 Setting an Antenna

To set the antenna parameter, proceed as follows:

1) Choose Setting > Antenna Setting. 2) In the Antenna Setting dialog box, do as Table 5-4 lists.

Table 5-4 Setting the antenna parameter

Functional button Operation

Add

1) Click Add.

2) Choose the .msi containing the antenna information in the open dialog box.

Note: You are allowed to choose various .msi files to import.

Remove 1) Choose an antenna.

2) Click Remove to delete the information about this antenna.

Profile 1) Choose an antenna.

2) Click Profile to check the antenna pattern.

Page 16: Apus manual

GENEX Apus User Manual Chapter 5 Engineering Parameter Management

5-7

Note:

In the .msi, the following information is contained: Antenna name Gain Working band 360° attenuation in the horizontal 360° attenuation in the vertical

The .msi can be obtained from the antenna operator.

3) Click OK.

Page 17: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-1

Chapter 6 Editing Engineering Parameter

6.1 Overview

This chapter aims to introduce:

Engineering parameter modification methods Map tools usage

This chapter profiles the followings:

Enabling an Engineering Parameter Editor Adding an NE Deleting an NE Modifying an NE Property Using a Map Tool

6.2 Enabling an Engineering Parameter Editor

To enable an engineering parameter editor, proceed as follows:

1) Right click the Parameter Editor, as Figure 6-1 shows. 2) Choose the Start visual editing on map option in the open menu.

Figure 6-1 Enabling the engineering parameter editor

3) In the Editing Engineering Parameters dialog box, choose Version Saved Last Time or Current Version.

4) Click OK.

Page 18: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-2

5) The Project Parameter Editor is displayed, as Figure 6-2 shows.

Figure 6-2 Project parameter editor

6.3 Adding an NE

In the Apus, the NEs to be added are:

Site Cell Sector Carrier

6.3.1 Adding a BTS

To add a BTS, proceed as follows:

1) Right click a BSC IP in the Object Tree, as Figure 6-3 shows. 2) Choose the Add BTS option in the shortcut menu.

Page 19: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-3

Figure 6-3 Adding BTS

3) In the Add/Modify BTS dialog box, do as Table 6-1 lists.

Table 6-1 Adding one BTS

Box Operation

BSC IP(*) Choose the existing BSC IP in the project.

BTS name (*)

Enter the BTS name.

Note: It is recommended that the BTS name be less than 256 characters.

Longitude (*) Enter the added BTS longitude, ranging from -180°–+180°.

Latitude(*) Enter the added BTS latitude, ranging from -90°– +90°.

BS equipment (optional)

Enter the current BS equipment.

BS configuration

(optional) Enter the current BS configuration. For example, S2/2/2.

City Enter the city or area where the BTS is located.

Note:

All the boxes with (*) must be filled. This principle is also applicable to all the NE setup dialog boxes.

4) Click Add.

Page 20: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-4

6.3.2 Adding a Cell

To add a cell, proceed as follows:

1) Right click an object in the Object Tree window. 2) Choose the Add cell option in the shortcut menu. The Add/Modify Cell dialog

box is displayed. Then, do as Table 6-2 lists.

Table 6-2 Adding the cell

Box Operation

Cell ID(*)

Enter the Cell ID, ranging from 1–4096.

Note: You are allowed to choose any number in the scope as the

cell ID.

Ensure that the different cells have different cell ID. That is, the cell ID is not repeatable.

Cell name

Enter the cell name.

Note: It is recommended that the cell name be less than 256 characters.

System ID (optional)

Enter the system ID of the cell.

Net ID (optional) Enter the net ID of the cell.

MSC No. (optional)

Enter the No. of the MSC that connects with the cell

3) Click Add.

6.3.3 Adding a Sector

To add a sector, proceed as follows:

1) Right click a cell in the Object Tree window. Select the Add Sector option in the shortcut menu.

2) In the open Add/Modify Sector dialog box, do as Table 6-3 lists.

Table 6-3 Adding the sectors

Box Operation

Sector ID(*) Enter the sector ID, which is usually 0, 1 or 2.

Page 21: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-5

Box Operation

Sector name

Enter the name of the sector.

Note: It is recommended that the cell name be less than 256 characters.

Co-Net with CDMA(optional)

Co-nets with other CDMA systems having different access bands.

Note: The engineers are allowed to enter the information as required.

Co-Net with GSM (optional)

Co-nets with the GSM system.

Note: The engineers are allowed to enter the information as required.

Cover description (optional)

Enter the terrain information of the covered area.

Antenna type Select the antenna type. The system calculates the antenna gain automatically.

Polarization

Choose the polarization mode:

Vertical polarization

Horizontal polarization

Height (m) Enter the antenna height, which ranges from 0–200.

Elec. tilt Enter the antenna electronic downtilt, which ranges from 0–20.

Diversity

Choose the antenna diversity mode:

Space diversity

Polarization diversity

Altitude (m) Enter the altitude of the position where the antenna is

located.

The altitude ranges from 0–200.

Azimuth (Degree) (*)

Enter the antenna azimuth, which ranges from 0–359.

Downtilt (Degree) Enter the antenna downtilt, which ranges from 0–90.

Pattern width Enter the antenna pattern width, which ranges from 0–180.

Page 22: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-6

Box Operation

7/8 feeder cable (Meter)

Enter the length of the 7/8 feeder cable.

The length ranges from 0–200.

5/4 feeder cable (Meter)

Enter the length of the 5/4 feeder cable.

The length ranges from 0–200.

3) Click Add.

6.3.4 Adding a Carrier

To add a carrier, proceed as follows:

1) Right click a sector in the Object Tree window. Choose the Add Carrier option in the shortcut menu.

2) In the Add/Modify Carrier dialog box, do as Table 6-4 lists.

Table 6-4 Adding the carriers

Box Operation

ARFCN (*) Enter the ARFCN ID which cannot be repeated by other ARFCN in the same sector.

PN offset (*) Enter the PN offset of the ARFCN, which ranges from 0–511.

Pilot power (dBm) Enter the pilot power in dBm.

LAC ID Enter the local area code ID.

Traffic channel number

Enter the number of the traffic channels.

3) Click Add.

6.4 Deleting an NE

To delete an NE, proceed as follows:

1) Right click the NE you are to delete in the Object Tree window. 2) Select an option in the shortcut menu. Table 6-5 lists the options in the shortcut

menu.

Page 23: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-7

Table 6-5 Deleting the NEs

Option Description

Delete XXX Refers to deleting the current NE including all of its sub-NEs.

Remove all XXX Refers to remove all the sub-NEs of the current NE (keep the current NE unmoved).

3) Click OK.

6.5 Modifying an NE Property

To modify an NE property, proceed as follows:

1) Right click the NE to be modified. 2) Choose the Modify XXX option in the shortcut menu.

For details concerning NE property setting, refer to 6.3 Adding an NE.

6.6 Using a Map Tool

6.6.1 Map Toolbar

Figure 6-4 shows the map toolbar.

Figure 6-4 Map toolbar

Table 6-6 lists the function of the icons on the toolbar.

Table 6-6 Function of the icon on the toolbar

Icon Function

Makes no influence on the map.

To move the position of the BTS.

To rotate the sector angle.

To zoom in the map with certain proportion.

To zoom in the specified area as per the selected area.

To zoom out the map with certain proportion.

To zoom out the specified area as per the selected area.

To move the map and adjust the NE display position.

Page 24: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-8

Icon Function

To select the single NE (BTS, sector, carrier)

To select the NEs by rectangle.

To select the NEs by radius.

To measure the distance between the two points.

To adjust the layer priority on the map.

Note:

The and only take effect in editing the engineering parameters.

6.6.2 Searching for an NE on the Map

To search for an NE on the map, proceed as follows:

1) Click on the map to activate the map window. 2) Press CTRL+F. The Find dialog box is displayed. 3) Select the field tile in the Find by list and enter the information in the Find what

box. 4) Click Find Next or Select All to search for the NEs on the map.

6.6.3 Modifying a Map Label

The Apus can modify the map label contents and the NE size.

To modify the map label, proceed as follows:

1) In the Neighbor Planning window, right click on the map and select the Redraw Map Label option in the shortcut menu.

2) In the Label Setting dialog box, set as Table 6-7 lists.

Table 6-7 Modifying the map labels

Parameter Description

Display properties

To select the display content on the NE:

Existing PN

Planned PN

Sector Name

Page 25: Apus manual

GENEX Apus User Manual Chapter 6 Editing Engineering Parameter

6-9

Parameter Description

Cell display To set the NE size on the map.

Label offset To set the relative offset of the label content and the NE.

Page 26: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-1

Chapter 7 Automatic Neighbor Planning

7.1 Overview

This chapter profiles the automatic neighbor planning function in the Apus, which includes:

Enabling the Neighbor Planning Executing the Neighbor Planning Checking the Neighbor Planning Result Adjusting the Neighbors Auditing the Neighbors Importing the Neighbor data Exporting the Neighbor Adjustment Script

7.2 Enabling the Neighbor Planning

To enable the neighbor planning function, proceed as follows:

1) Right click CDMA Network Planning, as Figure 7-1 shows. Choose the Start Neighbor Planning option in the shortcut menu. Or double-click the CDMA Network Planning node.

Figure 7-1 Starting the neighbor planning

The Neighbor Planning window is displayed. Compared with the Engineering Parameter window, the Neighbor Planning window lacks the Object Tree window, while shows a toolbar, as Figure 7-2 shows.

Figure 7-2 Neighbor planning toolbar

Table 7-1 lists the button functions on the toolbar.

Page 27: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-2

Table 7-1 Neighbor planning toolbar

Icon Operation

To show the neighbor of a carrier.

To add a neighbor to the carrier, proceed as follows:

1) Click .

2) Select a carrier.

A connection line shows up between the previous carrier and the newly selected carrier.

To remove a neighbor from the carrier, proceed as follows:

1) Click .

2) Select one of the neighbors of the carrier.

The connection line between the previous carrier and the newly selected carrier disappear.

To generate neighbor result.

To generate script for adjusting…. For details, refer to 7.8 “Exporting the Neighbor Adjustment Script”.

To start the neighbor setting.

To start the PN offset setting.

To import the neighbor lists.

When the BAM Neighbor or the Import Neighbor is

selected, import the existing neighbor lists by using .

7.3 Executing the Neighbor Planning

Note:

Before the neighbor planning, Huawei recommends that the users should enter the antenna height and downtilt for each sector.

To execute the neighbor planning, proceed as follows:

Page 28: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-3

1) Click on the neighbor planning toolbar. The Neighbor Setting dialog box is

displayed. 2) Set the default parameters, as Table 7-2 lists.

Table 7-2 Default parameter setting

Default parameter

Function Remark

Antenna height To set the antenna height

Antenna downtilt To set the antenna downtilt

If no new information is available, the default values are taken into consideration during calculation.

Default grid size To set the grid size

This parameter has great influence on the calculation.

Huawei recommends that calculation accuracy should be less than 50 meters for the dense area. the default grid size to 50m–200m. For the medium or large size network, the 100ms is suggested.

For the medium or the large network that have more than 100 BTSs or whose total coverage areas are more than 50km x 50km, Huawei recommends that the default grid size should remain within 50m–100m.

Min. Down Rx To judge whether it is the minimum downlink reception signal level.

The less the Min. Down Rx is set, the more the number of the automatically generated neighbors is.

Frequency type To select the frequency type used by the whole network

-

Coverage description

To select the area covered by the transmitter

Click Advanced to set these parameters.

Page 29: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-4

Default parameter

Function Remark

Max. neighbor count

To set the maximum neighbor count.

3) Click in the Neighbor Setting dialog box to select the propagation model for the calculation.

Note:

If the standard propagation model is selected, click Edit to set the model parameters K1–K7.

4) Click in the Neighbor Setting dialog box to select the BTSs to be applied in the neighbor planning.

5) Click OK. Then, the Genex Apus dialog box is displayed, as Figure 7-3 shows.

Figure 7-3 Finished neighbor planning

6) Click OK.

7.4 Checking the Neighbor Planning Result

7.4.1 Checking the Neighbor Result

To check the neighbor result, proceed as follows:

1) Click on the neighbor planning toolbar. The Generate Neighbor Result

dialog box is displayed. Table 7-3 lists the parameters and their meanings.

Page 30: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-5

Table 7-3 Checking the neighbor result

Parameter Description

Plan neighbor To generate the neighbor list after the automatic neighbor planning.

Import neighbor To generate the neighbor list result to be imported. For details concerning the neighbor data import, refer to 7.7 “Importing the Neighbor data”.

Neighbor type

BAM neighbor

To import the neighbor list in the BAM configuration data. For details concerning the BAM configuration data import, refer to 7.7 “Importing the Neighbor data”.

Carrier neighbor To create the neighbor relationship among carriers. Export option Sector neighbor To create the neighbor relationship among sectors.

2) Set the Neighbor Type to Plan neighbor and the Export Option to Carrier Neighbor.

3) Click OK. The Neighbor Carrier Table is displayed, as Figure 7-4 shows.

Figure 7-4 Neighbor carrier table

7.4.2 Checking the Result on the Map

To check the neighbor planning result on the map, proceed as follows:

1) Choose the neighbor type to be displayed, as Figure 7-5 shows.

Figure 7-5 Selecting the neighbor type

Page 31: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-6

Note:

Import the neighbor lists before checking the neighbor import and the BAM neighbor. For details concerning import method, refer to 7.7 “Importing the Neighbor data”.

2) Click on the network planning tool. The pointer of the mouse turns into

in the map window. 3) Select a carrier. On the map shows the neighbors of the carrier and the Neighbor

Carrier floating window is displayed, as Figure 7-6 shows.

Figure 7-6 Checking the neighbor planning result

7.5 Adjusting the Neighbors

This section is to introduce how to adjust the neighbors, which includes:

Adjusting the Neighbor Relationship Adjusting the Neighbor Priority

7.5.1 Adjusting the Neighbor Relationship

To adjust the neighbor relationship manually, proceed as follows:

Page 32: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-7

1) Click on the neighbor planning toolbar. The pointer of the mouse turns into

in the map window. 2) Select a carrier. On the map shows the neighbors of the carrier.

3) Click or to add or delete a neighbor of the current neighbor respectively.

The pointer of the mouse turns into .

7.5.2 Adjusting the Neighbor Priority

To adjust the neighbor priority, proceed as follows:

1) Click on the network planning toolbar. The pointer of the mouse turns into

in the map window. 2) Select a carrier. On the map shows the neighbors of the carrier and the Neighbor

Carrier floating window is displayed. 3) In the floating window, right click the row where the neighbor to be adjusted is

located. 4) Choose the Adjust neighbor priority option in the shortcut menu. 5) Input the new priority in the Adjust Priority dialog box, as Figure 7-7 shows. The

priority usually ranges from 0 to 31.

Figure 7-7 Adjusting the neighbor priority

7.6 Auditing the Neighbors

To audit the neighbors, proceed as follows:

1) Right click on the map and select the Verify neighbor option in the shortcut menu.

2) In the Neighbor Audit dialog box, select one of the boxes. If the Required Adjacent Cells as Neighbors box is selected, input the distance in the Distance box blow, as Figure 7-8 shows.

Page 33: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-8

Figure 7-8 Auditing the neighbor

3) Click OK. 4) Find the neighbor carriers that do not comply with the requirement in the open

Neighbor Check window. 5) Check reasons for incompliance in the Reason column.

7.7 Importing the Neighbor data

To import the existing neighbor data, proceed as follows:

1) Select the Import neighbor or BAM neighbor in the drop-down list box to define the neighbor type, as Figure 7-5 shows.

2) Click .

3) Select the .csv or .txt files containing the neighbor data in the Import neighbor From File dialog box.

Note:

The formats of the .csv file and the .txt file are as follows: Each row represents one neighbor relationship. The row consists of two parts, with Sector Name–Carrier ID in the front and

Adjacent Sector Name–Carrier ID at the back. The two parts are separated by commas. For the same sector, the neighbor priority is determined by the row sequence of the

neighbor relationship in the file.

Page 34: Apus manual

GENEX Apus User Manual Chapter 7 Automatic Neighbor Planning

7-9

7.8 Exporting the Neighbor Adjustment Script

The Apus can export the neighbor adjustment script according to the selected BAM type. Before script export, if the current BAM neighbor data is imported, the Apus is capable of generating the adjustment script according to the BAM data. Otherwise, the Apus considers by default that no neighbor data is available in BAM.

To export the neighbor adjustment script, proceed as follows:

1) Click on the network planning toolbar. The Generate Script For Adjusting

Neighbor dialog box is displayed. 2) In the Neighbor Type list, select the Plan Neighbor or the Import Neighbor

option as the reference for script adjustment. 3) Click OK. 4) Set the script name and path in the open dialog box. 5) Click Save.

Example:

Below shows the neighbor adjustment script: ADD NBRCDMACH: CCDMACH="101-101-0-160”, NBRCDMACHS="101-101-2-160", SFFLAG=SINGLE, DFFLAG=NULL, NBFLAG=SINGLE, SFRSN=0, NBRSN=0; ADD NBRCDMACH: CCDMACH="101-101-0-160", NBRCDMACHS="101-101-1-160", SFFLAG=SINGLE, DFFLAG=NULL, NBFLAG=SINGLE, SFRSN=1, NBRSN=1;

Page 35: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-1

Chapter 8 Automatic PN Planning

8.1 Overview

The PN planning in the Apus is based on:

Cluster or sub-cluster automatic allocation Refers to the automatic partitioning the cluster and sub-cluster based on the NodeB distribution.

Forbidden pair This kind of PN planning judges whether the distance between two NodeB is less than the reuse distance. If the distance is less than the reuse distance, other PN offsets are allocated.

The chapter consists of the following contents:

Enabling the PN Planning Setting a Single Carrier PN Property Executing the PN Planning Checking the PN Planning Result Checking the PN Reuse Exporting the PN Planning Result

8.2 Enabling the PN Planning

For details concerning the PN planning, refer to 7.2 “Enabling the Neighbor Planning”.

8.3 Setting a Single Carrier PN Property

To set the PN property of the single carrier, proceed as follows:

1) Click .

2) Right click a carrier. 3) Choose the Carrier property option in the shortcut menu. 4) In the Carrier Properties dialog box, set as Table 8-1 lists.

Table 8-1 Setting the PN property for the single carrier

Parameter Description

PN To change the PN offset of the current carrier.

Custom PN To customize a PN to be applied in the automatic planning.

Page 36: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-2

Parameter Description

Excluded PN

To specify those excluded PN offsets during planning.

Note: The excluded PN offset can be several and divided by comma.

5) Click OK.

8.4 Executing the PN Planning

To execute the PN planning, proceed as follows:

1) Select the NEs to be planned on the map by or .

2) Click . The PN Plan Setting dialog box is displayed.

3) Click Advanced. 4) In the Sub-Cluster Setting dialog box, set the parameters as Table 8-2 lists.

Table 8-2 Sub-cluster setting

Parameter Operation Remarks

PILOT_INC

Refers to Pilot PN Sequence Offset Increase.

To determine the number of the available PN offsets in the PN planning.

-

Start PN Refers to the first available PN that can be applied in PN planning.

-

Site sectors To set the maximum sectors of a BTS.

The default setting is recommended.

Note: If the number of the actual sector exceeds the default number, you need to adjust the redundant PN offsets manually.

Page 37: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-3

Parameter Operation Remarks

Sub-cluster count

Refers to the number of the sub-clusters of each cluster.

The same sub-clusters multiplex the PN offsets that belong to them.

Note: The same sub-clusters should be isolated far enough.

Reserved PN Refers to one or several PN offsets that do not participate in PN planning.

If several reserved PNs are available, divide them by commas.

External PN Refers to the PN offsets excluded from the planning area.

When the current network has the handoff relationship with external networks, ensure that the current PN offsets do not conflict with the external ones.

Optimized for asymmetry sites

- Unavailable

Min reuse distance

Refers to the minimum reuse distance of the PN offset.

This parameter is only applicable to the PN Planning based on Forbidden Pairs. If the distance between the two PN reuse cells is less than the Min Reuse Distance, these cells are refused to conduct the PN reuse.

Page 38: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-4

Note:

The data format for external import is .csv. For example, Site Name, Longitude, Latitude, Azimuth, PN offset, and Sector ID Petchcharat, 101.126944, 14.633889, 90, 12, 1 Petchcharat, 101.126944, 14.633889, 160, 180, 2 Petchcharat, 101.126944, 14.633889, 250, 348, 3 Mitthatap, 101.2095, 14.633778, 340, 68, 1 Mitthatap, 101.2095, 14.633778, 100, 236, 2

5) After the parameter setting, click OK.

8.5 Checking the PN Planning Result

8.5.1 Checking the PN Planning Table

After the PN calculation, the PN Planning Result window is displayed, as Figure 8-1 shows.

Figure 8-1 PN planning result

8.5.2 Checking the Cluster or Sub-cluster Allocation Result

To check the cluster or sub-cluster allocation result, proceed as follows:

1) Right click on the map.

Page 39: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-5

2) Choose the Show PN cluster or Show PN sub-cluster option in the shortcut menu. The NEs belonging to different clusters or sub-clusters are shown in distinguished colors.

8.6 Checking the PN Reuse

The Apus can check the PN reuse both automatically or manually.

To check the PN reuse, proceed as follows:

1) Right click on the map. 2) Choose the Reused-PN check option in the shortcut menu. The PN Reuse

Check dialog box is displayed, as Figure 8-2 shows.

Figure 8-2 PN reuse check

3) Set the parameters in the PN Reuse Check dialog box, as Table 8-3 lists.

Table 8-3 Parameter setting in PN reuse check

Parameter Description

Min. PN Re-use To set the minimum PN reuse distance during checking.

Plan neighbor

Import neighbor

To determine the neighbor relationship during the PN reuse check.

Page 40: Apus manual

GENEX Apus User Manual Chapter 8 Automatic PN Planning

8-6

Parameter Description

Check existing neighbors

Check second order neighbor

Check adjacent PNs

To check the same PNs under different circumstances.

Check imported PN

Check planned PN To select the PN to be checked.

PILOT_INC If the Check adjacent PN option is selected, these NEs whose PN interval is less than or equal to the PILOT_INC are checked out.

4) Click OK. A prompt is displayed, listing the invalid PNs and the reasons for invalidity.

8.7 Exporting the PN Planning Result

To export the PN planning result, proceed as follows:

1) Click the PN planning result window, as Figure 8-1 shows. 2) Right click the window. 3) Select the Save… option in the shortcut menu. 4) Set the file name to .csv and the file path in the open dialog box. 5) Click Save.