Applying the latest version of the National Ventilation Standard Heyoka Solutions, LLC Paul H. Raymer All Contents Copyright 2013 by Heyoka Solutions, LLC. ALL RIGHTS RESERVED. Any use of materials, photographs, drawings, depictions or content, including reproduction, modification, distribution or republication, without the prior written consent of Heyoka Solutions, LLC, is strictly prohibited. Copyright infringement is a violation of federal law subject to criminal and civil penalties.

Upload: others

Post on 13-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

Applying the latest version of the National Ventilation Standard

Heyoka Solutions, LLC

Paul H. Raymer

All Contents Copyright 2013 by Heyoka Solutions, LLC. ALL RIGHTS RESERVED. Any use of materials, photographs, drawings, depictions or content, including reproduction, modification, distribution or republication, without the prior written consent of Heyoka Solutions, LLC, is strictly prohibited. Copyright infringement is a violation of federal law subject to criminal and civil penalties.

Page 2: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Located on Cape Cod, Massachusetts;

Member ASHRAE 62.2 SSPC 10+ years

HERS Rater, BPI Analyst, Envelope, Heating, and AC/Heat Pump Certified;

Certified IREC/ANSI Assessor;

Author of the Residential Ventilation Handbook

Page 3: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 4: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

One cubic foot of air (cfm) moves into a house only if one

cubic foot of air moves out of the house.

1cfm in = 1 cfm out

Page 5: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Air always flows from areas of higher pressure to

areas of lower pressure.

(Second Law of Thermodynamics)

Page 6: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

• CFM – cubic feet per minute;

• FPM – feet per minute

• Static pressure – resistance to flow - measured in "WC (iwg) or Pa (Pascal);

• Sone – linear measurement of sound;

• HVI (Home Ventilating Institute) and HRAI (Heating Refrigeration and Air Conditioning Institute of Canada).

Page 7: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Whole Building Ventilation is dilution ventilation – “the solution to pollution is dilution”.

Courtesy of Panasonic

& Paddy Morrissey

Page 8: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

(4) “Air” Changes = 6.25% Pollution

Pure “Pollution” (2) “Air” Changes 25% pollution

(1) “Air” Change

50% pollution

(3) “Air” Changes

12.5% pollution

Page 9: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1. Natural airflow through the building depends on many factors including temperatures, wind, mechanical forces, etc. It is not constant. It is variable.

2. People essentially need the same amount of fresh air to breathe. It is constant. It is not variable.

3. You cannot satisfy a constant need with a variable source unless that source constantly exceeds the need.

9

Page 10: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

10

People

Building Air Leakage

Time

Wea

ther

Over ventilated

Under ventilated

Page 11: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 12: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

National Ventilation Standard

Single family, multifamily up to three stories, and manufactured and modular buildings;

Considers chemical, physical, and biological contaminants but does not consider thermal comfort;

Acceptable IAQ will not necessarily be achieved even if all requirements are met.

Page 13: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Requires whole-building ventilation in all new and the majority of existing homes;

Provides sizing procedures;

Outlines equipment parameters;

Requires installed system testing.

Requires local exhaust ventilation in bathrooms and kitchens in all homes;

Provides sizing procedures;

Outlines equipment parameters;

Requires installed system testing.

Page 14: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Select a whole building airflow from the table (or calculate it);

Select appropriate airflow rates for local exhaust;

Select quiet equipment whose performance is certified by HVI;

Install it so it works; Test it to prove that it works; Document the design.

Edward Brannock, Pilot & Entrepreneur

Page 15: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 16: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Ventilation rate by the formula or by the table.

Pick a number from the table:

How big is the house?

How many bedrooms does it have?

Page 17: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Floor Area (ft2) 1 2 3 4 5

<500 ft2 30 38 45 53 60

501 – 1000 45 53 60 68 75

1001 - 1500 60 68 75 83 90

1501 - 2000 75 83 90 98 105

2001 - 2500 90 98 105 113 120

2501 - 3000 105 113 120 128 135

3001 - 3500 120 128 135 143 150

3501 - 4000 135 143 150 158 165

4001 - 4501 150 158 165 173 180

4501 - 5000 165 173 180 188 195

Example: 1200 square foot house with 2 bedrooms. Requires 68 cfm continuous ventilation.

Page 18: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Formula:

Qtot = 0.03Afloor + 7.5 x (Nbedrooms +1)

Example: Same 1200 square foot 2 bedroom house: (1200 x .03) + 7.5 x (2 + 1) = 36 + 22.5 = 58.5 cfm Lower airflow than the table, but remember that 62.2 is a MINIMUM ventilation guideline.

Page 19: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

If the home has had a blower door test, the actual infiltration can be used to adjust the ventilation rate.

0.052* x CFM50 x S x wsf = “infiltration credit” (Qinf)

* Derivation of the 0.052 constant: ELA = (Q50/50.65) x (dP.65)x sqrt(rho/2 x dP)) NL = 1000 x ELA/Afloor x S Qinf(cfm) = (NL x wsf x Afloor)/7.3 dP = delta P (4) Rho = density of air (1.2 kg/m3)

Page 20: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Atlantic City Intl AP 0.53

Belmar Asc 0.52

Caldwell/Essex Co. 0.44

Cape May Co 0.49

McGuire AFB 0.48

Millville Muni AP 0.44

Newark Intl AP 0.54

Teterboro AP 0.5

Trenton Mercer County AP 0.48

There are 1100 ‘wsf’ factors!

1 Story 1

1.5 Stories 1.18

2 Stories 1.32

2.5 Stories 1.44

3 Stories 1.55

Building height

factors (s)

Wsf factors for NJ:

Page 21: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1200 square foot, 2 bedroom, 1 story house in Trenton, NJ

Initial Blower Door number of 1400 CFM50

0.052 x CFM50 x S x wsf = “infiltration credit”

0.052 x 1400 x 1 x 0.48 = 34.9

Page 22: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1200 square foot, 2 bedroom, 1 story house in Trenton, NJ

Initial Blower Door number of 1400 CFM50

Original whole building ventilation rate = 58.5

With infiltration credit:

58.5 – 34.9 cfm = 24 cfm

Page 23: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1200 square foot, 2 bedroom, 1 story house in Trenton, NJ

Initial Blower Door number of 1400 CFM50

Final Blower Door number of 1100 CFM50

0.052 x CFM50 x S x wsf = “infiltration credit”

0.052 x 1100 x 1 x 0.48 = 27.5

Page 24: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1200 square foot, 2 bedroom, 1 story house in Trenton, NJ

Initial Blower Door number of 1400 CFM50

Final Blower Door number of 1100 CFM50

Original whole building ventilation rate = 58.5

With infiltration credit:

58.5 – 27.5 cfm = 31 cfm

Page 25: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

1200 square foot, 2 bedroom, 1 story house in Trenton, NJ

Blower door value

Qinf (Infiltration credit)

Whole building ventilation rate

1400 CFM50 34.9 cfm 24 cfm

1100 CFM50 27.5 cfm 31 cfm

Page 26: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Gives credit for existing fans and operable windows and infiltration.

Page 27: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Compliance options for existing buildings:

o Whole building ventilation rate is the sum of the whole building rate determined by table 4.1 plus any deficit for existing spot ventilation fans minus an infiltration credit.

Measure the airflow through existing fans and compare that to the local exhaust requirements;

An operable window reduces the deficit by 20 cfm.

Page 28: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

1580 square foot, 3 bedroom, 1 story house in Madison, WI (wsf = 0.61)

Initial Blower Door number of 1400 CFM50

Kitchen has a window and a fan that moves 60 cfm.

Bathroom has a window and a fan that moves 20 cfm. Existing fans can be left in place.

Whole building ventilation rate can be increased.

Page 29: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Operable Window = 20 cfm Kitchen requires 100 cfm. It has a window and a 60 cfm fan: 100 – 60 – 20 = 20 cfm “deficit” Bathroom requires 50 cfm. It has a window and a 20 cfm fan: 50 – 20 – 20 = 10 cfm “deficit” Ventilation deficit = (20 + 10)/4 = 7.5 Original Whole Building Ventilation rate:

1580 x 0.03 + 7.5 x (3 + 1) = 77 cfm Adjusted Whole Building Ventilation rate = 77 + 7.5 = 85 cfm

Page 30: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Adjusted Whole Building Ventilation rate = 77 + 7.5 = 85 cfm With Infiltration Credit for original Blower door number (1400 CFM50) :

0.052 x 1400 x 1 x 0.61 = 44.4

77 + 7.5 - 44 = 41 cfm (whole building ventilation rate) With tightened home Infiltration Credit:

0.052 x 1100 x 1 x 0.61 = 34.9

77 + 7.5 – 34.9 = 50 cfm

(whole building ventilation rate)

Page 31: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

1580 square foot, 3 bedroom, 1 story house in Madison, WI

Start

Blower door 1400 CFM50

Tightened Blower door 1100 CFM50

Initial Flow Rate 77 cfm

With Appendix A only

85 cfm

With Infiltration Credit & Appendix A

41 cfm 50 cfm

Page 32: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

• The existing building calculation can only be

used for existing homes.

• A really leaky existing house can have a required whole building mechanical ventilation rate of 0 cfm.

Page 33: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 34: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

The intermittent operation option adds a bit of complexity.

Short durations (3 hours or less cycle time) are simple:

Run ½ the time double the required flow;

Run 1/3 the time triple the flow.

Page 35: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Pin Timer

Electronic Timer

Programmable Intermittent Timer

Fan & Light Switch

Page 36: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 37: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Select equipment with performance certified by AMCA or HVI;

Very quiet: 1 sone or less – quieter than a quiet refrigerator!

Exhaust or Supply only ventilation;

Mechanically balanced ventilation;

Mechanically balanced ventilation with heat or energy recovery.

Page 38: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

© Raymer, Residential Ventilation Handbook

Page 39: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Desiccant wheel ERV 2nd Law of Thermodynamics – Heat moves to cold, wet moves to dry Heat Recovery Ventilator (HRV) transfers heat from the warm air stream to the cool air stream. Energy Recovery Ventilator (ERV) transfers heat and moisture from warm, moist air stream to the cooler, drier air stream.

Page 40: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

If the house is tight, in a heating dominated climate, less moisture inside the house will be removed by an ERV because it will be transferred to the incoming air stream. HRV and ERV efficiency ratings are based on balanced operation. Their efficiencies will change if they are connected to air handlers and run in an unbalanced condition. They need to be installed where their filters and cores can be maintained. They do not supply EXTRA air to balance other devices.

Page 41: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Fresh air supply

with a motorized

damper

Fan cycler switch runs air handle at 20

minute intervals

Supply side of air handler

Kitchen Bedroom

Bath

Source: Paul Francisco

Page 42: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Outside air supplied to return side of the air handler

Aldes CAR

AirCycler Field Controls Damper

Page 43: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Local ventilation removes the pollutants at the source.

Page 44: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Intermittent Continuous

Kitchen 100 cfm Vented range hood required if

exhaust fan flow rate is less than 5 kitchen ACH

5 ACH

Bathroom 50 cfm 20 cfm

Page 45: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Typical ceiling insert

bath fans.

Certified by HVI or AMCA

for both airflow and sound.

Page 46: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Range hoods

Exterior mounted fan

Page 47: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Select a whole building airflow from the table (or calculate it);

Select appropriate airflow rates for local exhaust;

Select quiet equipment whose performance is certified by HVI;

Page 48: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Page 49: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Air is lazy;

Electrons are more forgiving;

Never use “duck” tape;

Always choose the shortest, straightest path to the outside;

System must be serviceable;

Never, never, never vent into the attic.

Page 50: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

• In-line fans are designed to drag air

through ducts;

• Propeller or axial fans are not good for

ducts;

• Backdraft dampers can cut the airflow in

half.

© Raymer, Residential Ventilation Handbook

Page 51: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

The effects of duct length on airflow performance in more detail.

Actual length is the actual, physical

length of the duct run (how far is it from

A to B);

Equivalent length is equivalent

resistance to the airflow generated by

the fittings;

Effective length is the sum of the Actual

and Equivalent lengths.

Actual length + Equivalent length = Effective length

© Raymer, Residential Ventilation Handbook

Page 52: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Description Equivalent Length

(Ft) for rigid

ducting

45° adjustable

elbow, 2-piece

5

90° adjustable

elbow, 4-piece

10

Wye, equal sizes 10

Tee, take-off 50

Tapered

increaser/reducer

4

Hard

increaser/reducer

8

© R

aym

er, Resid

ential V

entilatio

n H

and

bo

ok

Page 53: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Description Equivalent Length

(Ft)

Triangular wall cap for round duct

with backdraft damper & bird screen

28

Triangular wall cap for round duct

with bird screen, without backdraft

damper

14

Rounded wall cap for round duct

with backdraft damper & bird screen

14

Louvered wall cap 16

Low profile soffit vent with

backdraft damper and bird screen

33

Roof cap, low-profile for round duct

with backdraft damper & bird screen

60

Roof cap, ‘goose-neck’, for round

duct with backdraft damper & bird

screen

71

© R

aym

er, R

esid

enti

al V

enti

lati

on

Han

db

oo

k

Page 54: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Increasing the duct diameter from 4” to 6” will dramatically reduce the friction loss.

From Jennings, Environmental Engineering Analysis and Practice ,1970

7.5 Pa 62.5 Pa

Page 55: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Ducts need to be supported;

Choose the shortest path;

Ducts running through unheated

spaces must be insulated.

Page 56: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

“In theory, everything works in practice. In practice, it’s different.”

Yogi Berra

Page 57: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Duct Blaster with DG700

Q200 Duc-Tester

with DM-2 gauge

Page 58: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Calibrated Duct Tester Fan Under Test

Point A

When the pressure at Point A = 0 pa, the flow through the Duct Tester fan = the flow through the fan under test.

Page 59: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2013

Page 60: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

1. Set the Device on the DG700 to EXH;

2. Set the Config to correspond to the opening on the Exhaust hood (A1, B2, C3);

3. “T” both channel inputs to the hose connected to the Exhaust hood;

4. If the pressure on Channel A exceeds 8 pa, open the Exhaust hood to the next notch;

5. Read the flow on Channel B.

If the flow exceeds 124 cfm, a different device must be used.

Page 61: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

A Balometer will measure flows between 10 and 500

cfm.

Vane anemometer is less effected by ambient conditions like temperature, humidity and altitude. Accurate between 0 and 75 cfm.

Page 62: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Brand Model ID Required Airflow

Tot. Installed Airflow Normal Boost

Fanwho Quantum 3 36.5 42 76

Ventilation Product Information:

Brand Model ID Function (Multi-speed, intermittent, etc.)

Fanwho IAQ4040 Multi-function, variable flow

Control:

System Function & Operating Notes

HRV designed to exhaust air from the bathrooms and supply air to the bedrooms, low speed continuous operation, manual boost.

Req. Maintenance Clean filters monthly. Replace annually.

Clean the core annually.

Page 63: Applying the latest version of the National Ventilation ... · Located on Cape Cod, Massachusetts; ... Compliance options for existing buildings: o Whole building ventilation rate

©Heyoka Solutions, LLC 2012

Thanks for listening