9B20 Ver. 2/1/2020 Based on the 2020 BCNYS and 2020 FCNYS APPENDIX Student Exercises and Supplemental Material Fire Safe Design Table of Contents Occupancy Classification exercise Appendix 2-3 Type of Construction exercise Appendix 4-5 Building Height and Area exercise Appendix 6 Designer’s Formula Information Appendix 7-10 Incidental, Accessory and Mixed Use exercise Appendix 11-12 Fire Separation Distance exercise Appendix 13 Allowable Area of Openings exercise Appendix 14 Fire-resistance Rated Assemblies exercise Appendix 15 Sprinkler Systems – Where required exercise Appendix 16 Standpipe System – Where required exercise Appendix 17 Alarm and Detection exercise Appendix 17 Fire Apparatus Access Roads Appendix 18 Egress – Design Occupant Load exercise Appendix 19 Egress – Convergence exercise Appendix 20 Egress – Exit Signs exercise Appendix 21 NEW YORK STATE, DEPARTMENT OF STATE Building Standards and Codes Division One Commerce Plaza 99 Washington Avenue Albany, NY 12231-0001 Phone: (518) 474-4073 Fax: (518) 474-5788 www.dos.ny.gov

Upload: others

Post on 08-Dec-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

9B20 Ver. 2/1/2020 Based on the 2020 BCNYS and 2020 FCNYS

APPENDIX

Student Exercises and Supplemental Material Fire Safe Design

Table of Contents

Occupancy Classification exercise Appendix 2-3 Type of Construction exercise Appendix 4-5 Building Height and Area exercise Appendix 6 Designer’s Formula Information Appendix 7-10 Incidental, Accessory and Mixed Use exercise Appendix 11-12 Fire Separation Distance exercise Appendix 13 Allowable Area of Openings exercise Appendix 14 Fire-resistance Rated Assemblies exercise Appendix 15 Sprinkler Systems – Where required exercise Appendix 16 Standpipe System – Where required exercise Appendix 17 Alarm and Detection exercise Appendix 17 Fire Apparatus Access Roads Appendix 18 Egress – Design Occupant Load exercise Appendix 19 Egress – Convergence exercise Appendix 20 Egress – Exit Signs exercise Appendix 21

NEW YORK STATE, DEPARTMENT OF STATE Building Standards and Codes Division One Commerce Plaza 99 Washington Avenue Albany, NY 12231-0001 Phone: (518) 474-4073 Fax: (518) 474-5788 www.dos.ny.gov

Appendix

Appendix - 2

Occupancy Classification Exercise Using Chapter 3 of the Building Code list the appropriate occupancy designation

What is the Occupancy?

• Cell phone tower ______

• Hotel (transient) ______

• Movie theater ______

• Elementary school ______

• Mental hospital ______

• College basketball arena ______

• Building department offices ______

• Clothing store ______

• Explosives manufacturing plant ______

• Café seating 65 people ______

• Infant day care center with 15 children ______

• Masonry block manufacturing plant ______

Appendix

Appendix - 3

Occupancy Classification Exercise Using Chapter 3 of the Building Code list the appropriate occupancy designation

Motor Vehicle Related Occupancies

What is the Occupancy?

Public parking garage ______

Automobile showroom ______

Repair garage ______

Car factory ______

Motor fuel dispensing station______

Appendix

Appendix - 4

Type of Construction Exercise Exercise #1. This building is proposed to be Type II-B, Non-combustible. What are the minimum fire-resistive ratings for the building elements?

Exercise #2. Does this building satisfy Type III-A Construction requirements?

Non-combustible Roof: 1 hour

Roof: ____ hour rating

Exterior bearing walls: ____ hour rating

Structural frame: ____ hour rating

Floor/ceiling: ____ hour rating

Non - combustible exterior bearing walls, 2 hours

Combustible, non - load bearing partition, nonrated

Structural frame or interior bearing wall 1 hour

Wood framed floor/ceiling, 1 hour

Appendix

Appendix - 5

Type of Construction Exercise Exercise #3. Does this building satisfy Type IV Construction requirements?

Exercise #4. This building is proposed to be Type I-A, Non-combustible. What are the minimum fire-resistive ratings for the building elements?

Non - combustible exterior bearing

walls, 1 hour

Roof heavy timber

Non - bearing partition, solid wood

Floor/ceiling heavy timber

Exterior bearing walls: ____ hour rating

Roof: ____ hour rating

Non - bearing partition: ____ hour rating

Floor/ceiling: ____ hour rating

Appendix

Building Story, Height and Area Exercise

Using Tables 504.3 Height in Feet, 504.4 Height in Stories, and 506.2 Allowable Area Factor. Occupancy

Group Type of

Construction Height in

Feet Height

in Stories

Other details Allowable Area

Department store

Noncombustible elements, no additional fire resistance

Sprinklered 2 Story

Sleepy Time Motel transient

Masonry exterior walls, 2 hour rated, and unrated wood frame interior

Nonsprinklered 1 Story

Bob’s Bar and Grill

Log Cabin Sprinklered 2 Story

Veterinary Hospital

Wood frame, no fire resistance rating

Nonsprinkler 3 Story Appendix - 6

Appendix

Appendix - 7

Exercise 1: M Occupancy of Type IIIB construction Three stories - Fully Sprinklered

Is this correct? Do these Two numbers verify?

Aa = At + (NS x If)

Aa = 37,500 + (18,500 x If)

Exercise 2: B Occupancy of Type VB construction

Four stories - Fully Sprinklered

Is this correct? Do these Two numbers verify?

Aa = At + (NS x If)

Aa = 27,500 + (9,000 x If)

Appendix

Appendix - 8

Exercise 3: R-2 Occupancy of Type VB construction two stories - NFPA 13-R Sprinkler

Is this correct? Do these Two numbers verify?

Aa = At + (NS x If)

Aa = 7,000 + (7,000 x If)

Exercise 4: E Occupancy of Type IIB construction

One story - partially Sprinklered

Is this correct? Do these Two numbers verify?

Aa = At + (NS x If)

Aa = 58,000 + (14,500 x If)

Appendix

Appendix - 9

Exercise 5:

Is this correct? Do these Two numbers verify?

IFP

Wf = −

×0 25

30.

L1 L3

L2

L4

Appendix

Appendix - 10

Does this verify? Compare all the Numbers?

( ) ( ) ( )W

L W L W L WL L L

=× + × + ×

+ +1 1 2 2 3 3

1 2 3

Exercise 6:

( ) ( ) ( )W =

× + × + ×+ +

80 30 150 30 80 3080 150 80

F

Appendix

Appendix - 11

Exercise - Uses and Separations:

Proposed: Type II-B Construction, No Sprinkler

First step: is to calculate the sizes of each separate use.

Second step: is to determine which use(s) qualifies as an “Accessory” Use (Section 508.2)?

Third step: is to determine which uses are considered a mixed use.

Fourth step: is to determine which type of separation is required between the mixed use(s). The choices are:

Answer questions on next page using this diagram

’ 100 Group M Sales Area

Office for Group M

Group S - 2 Storage

’ 130

50 ’ 40 ’ 40 ’

Wall “A”

• Non rated wall • Fire Partition

• Fire Barrier

Appendix

Appendix - 12

Exercise - Uses and Separations Answer questions using diagram on previous page.

Question (1) Can Wall “A” be non-rated?

Question (2) IF the proposal is a SEPARATED MIXED USE can the wall be a Fire Partition?

Question (3 ) IF the proposal is a SEPARATED MIXED USE can the wall be a Fire Barrier?

Appendix

Appendix - 13

Fire Separation Distance 705.3 Buildings on the Same Lot

Using table 602 determine the following:

1) Distance from the EXISTING building to the imaginary line

2) Distance from the NEW building to the imaginary line.

Type IIB construction

B Occupancy

EXISTING

BUILDING

NEW

BUILDING

?

?

Appendix

Appendix - 14

Allowable Area of Opening Exercise

• Exterior wall 12’ from interior property line • Protected/unprotected openings as shown

• Determine if the areas of unprotected opening s are permitted

Ap = proposed protected openings

ap = allowable protected openings base on the table

Au = proposed un-protected openings

au = allowable un-protected openings base on the table

Ap + Au < 1 ap au

12 ft.

40 FT.

18 FT.

3 FT. x 10 FT. UNPROTECTED OPENING

3 FT. x 6 FT. 8 IN. PROTECTED FIRE DOOR

9 FT. x 7 FT. UNPROTECTED

OPENING

Step 1) determine wall area (L x W)

Step 2) determine allowable area of windows and Doors based on table 705.8.

Step 3) determine area of proposed openings

Step 4) plug numbers into formula above.

Appendix

Appendix - 15

Fire-resistance Rated Assemblies 1. Find at least 10 situations where the Code requires a FIRE BARRIER.

1) ___________________________________________________________ 2) __________________________________________________________ 3) __________________________________________________________ 4) __________________________________________________________ 5) __________________________________________________________ 6) __________________________________________________________ 7) __________________________________________________________ 8) __________________________________________________________ 9) __________________________________________________________ 10) __________________________________________________________

2. What are the non-sprinklered and sprinklered hourly values between Groups H-3 and I-3 in a Type III-A building, per Table 508.4?

A) ______________________________ B) ______________________________

3. What are the non-sprinklered and sprinklered hourly values between fire areas within Group M in a Type V-B building, per Table 508.4?

A) ______________________________ B) ______________________________

Appendix

Appendix - 16

Sprinkler Systems: Where Required. Please list answers in the space provided For the following examples, indicate that a sprinkler is required or not required for new construction. Indicate where the sprinklers must be installed and cite the appropriate code section.

1. Single story, office building, 30,000 SF in area. Occupancy classification: __________ Required or Not-required: __________ Where in the building: ____________________________ Code citation: ____________________________

2. A restaurant occupies the third story of an office building. Occupancy classification: __________ Required or Not-required: __________ Where in the building: ____________________________ Code citation: ____________________________

3. A single story motel. Occupancy classification: __________ Required or Not-required: __________ Where in the building: ____________________________ Code citation: ____________________________

4. A Woodworking Factory, 10,000 SF at grade. Occupancy classification: __________ Required or Not-required: __________ Where in the building: Code citation:

5. A semi-conductor manufacturing facility using HPM (Hazardous production materials).

Occupancy classification: __________ Required or Not-required: __________ Where in the building: ___________________________ Code citation:

6. A four story department store.

___________________________

Occupancy classification: __________ Required or Not-required: __________ Where in the building: ___________________________ Code citation: ___________________________

Appendix

Appendix - 17

Extra Credit: A 10 story office building design for 100 people on each story.

Occupancy classification: ___________________________ Required or Not-required: ___________________________ Where in the building: ___________________________ Code citation: ___________________________

Standpipe System: Where Required

If this Agency Building was constructed today, would a Standpipe system be required?

If so, what are the important details? Please list in the space below.

_________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________

Alarm and Detection: Where Required In a GROUP F occupancy:

• When is a system required? ______________________________ • What type of system is required? ______________________________

In a GROUP R-1 Occupancy: • When is a system required? ______________________________ • What type of system is required? ______________________________

In a GROUP R-2 Occupancy – Student Housing • When is a system required? ______________________________ • What type of system is required? ______________________________ • Where is it required? ______________________________

Appendix

Appendix - 18

Student Research

Fire Apparatus Access Road (FAAR)

Using 503, find the specifications for:

Minimum width

Vertical clearance

Surface characteristics

Turning radius

Dead ends

Appendix

Appendix - 19

Egress: Design Occupant Load

Retail sales/mercantile

Calculate size of space and Occupant load here:

Office occupancy

Calculate size of space and Occupant load here:

Appendix

Appendix - 20

Egress: Multiple Levels and Convergence GIVEN:

• 4 Story, Non-sprinklered Office Building • Occupants from each level into 44” stair enclosure as indicated • First floor has independent exit without entering stair enclosure

Complete the information on the Table below

Stair

Exit Element Occupant Load Served Required Width

Stair at ‘A’

Stair at ‘B’

Stair at ‘C’

Stair at ‘D’

Door at ‘E’

Enclosure

200 people

150 people

240 people

Basement 150 people

A

B

C

D

Exit door from Stair Enclosure ‘E’

Appendix

Appendix - 21

Find and list the Requirements for Ramps

• Maximum Slope

• Maximum Rise

• Minimum Width

• Minimum Headroom

• Minimum Dimensions for Landings

Where are Exit Signs required? • ALL doors shown are required access or exit doors.

• Indicate on the drawing below where the exit signs should be placed.