a.olchevski, jinr (dubna) test beam studiesof compass ecal0 test beam studies of compass ecal0...
DESCRIPTION
A.Olchevski, JINR (Dubna) Since 1989 many GM APD structures were developed by different developers: CPTA/Photnique(Moscow/Geneva) ~1000 pixels/mm Zecotek(Singapore, Dubna) up to 40000pixels/mm MEPhI/Pulsar (Moscow) ~1000 pixels/mm Hamamatsu Photonics (Hamamatsu, Japan) up to 1600 pixel/mm SensL(Cork, Ireland) RMD (Boston) MPI Semiconductor Laboratory (Munich, Germany) FBK-irst(Trento, Italy) ……Every producer invented their own name for this device:MRS APD, MAPD, SiPM, SSPM, SPM, G-APD … MAPD Developers and producersTRANSCRIPT
![Page 1: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/1.jpg)
A.Olchevski, JINR (Dubna)
Test Beam studiesTest Beam studies of COMPASS of COMPASS ECAL0ECAL0 module module prototype with MAPD readoutprototype with MAPD readout
ECAL0 Team, JINR, DUBNA
![Page 2: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/2.jpg)
A.Olchevski, JINR (Dubna)
Possible view of ECAL0: sizes: ~ 360x360 cm2 with central hole ~ 120x120 cm2
length: ~ 25-30 cm modules: 800 with size 12x12
cm2 (“shashlyk”) MAPDs: ~9300 (Multipixel Avalanche PhotoDiode)
for inner part: 16 MAPDs per module for outer part: 9 MAPDs per module
![Page 3: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/3.jpg)
A.Olchevski, JINR (Dubna)
ZECOTEK: MAPD-3A 15 000/mm2
MAPD-3B 40 000/mm2
MAPD Stucture
![Page 4: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/4.jpg)
A.Olchevski, JINR (Dubna)
Characterics of MAPD
![Page 5: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/5.jpg)
A.Olchevski, JINR (Dubna)
• high number of pixels ~135 000 ( 3x3 mm2 )• work at low bias voltage (<70 V),• PDE ~12 %( 520 nm) (Photon Detection Efficiency)• Gain ~3x104
• Temperature dependences ~ 3%• insensitive to magnetic fields up to 15 T,• compact, rugged and show no aging*• tolerate accidental illumination• radiation hardness (>1012 p/cm2 ) *• Capacitance ~ 300pF
Problems: recovery time , temperature dependence dependence gain vs voltage Gain and PDE
* under study
Characterics of MAPD
![Page 6: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/6.jpg)
A.Olchevski, JINR (Dubna)
3 type modules: - sampling 4mmSc/4 mm Pb, 96x96 mm2 , 36 fibers, 6ch-s (~10-11 % sampling)
- sampling 4mmSc/2 mm Pb, 12.12x12.12 cm2 , 64 fibers(32 loops), 1 tower ,4 bandles , Db = 6 mm - sampling 4mmSc/2 mm Pb, 4.04x4.04cm2 , 144 fibers(72 loops), 9 tower, Db = 6 mm (~7%)
Goals of the measurements - Resolution vs energy - Compare results with MAPD and PM - Number of photoelectrons - Temperature stabilization - Calibration by LED (monitored by pin diode) - Optimization of module structure
BEAM test at PS (T9)
![Page 7: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/7.jpg)
A.Olchevski, JINR (Dubna)
Light guide - coneD1 / D2= 6/4.4KPM=0.54KAmpd/PM=0.6
![Page 8: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/8.jpg)
A.Olchevski, JINR (Dubna)
Setup at Beam test atT9
![Page 9: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/9.jpg)
A.Olchevski, JINR (Dubna)
FEE – fast preamplifier, G=14 Trigger – COMPASS( Munich, Protvino) DAQ – VME CAEN V792AC Charge ADC 32 Ch ( SADC Option)Temperature stabilization - Peltier cooler with fan (working point 15o +-0.2o)*Calibration – Led, controlled by Pin Diode
*The method of gain stabilization by using feedback with HV is possible, but noise increase with T (2 times/ 9 degree)
Read Out
![Page 10: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/10.jpg)
A.Olchevski, JINR (Dubna)
Response 1 tower modules at 4 GeV
1 ch= 5.24 Phe 1 ch=2.00 Phe
![Page 11: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/11.jpg)
A.Olchevski, JINR (Dubna)
Stability
![Page 12: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/12.jpg)
A.Olchevski, JINR (Dubna)
Response vs Beam Intensity
![Page 13: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/13.jpg)
A.Olchevski, JINR (Dubna)
Response & resolution vs Beam Energy
Response & resolution of PM Response & resolution of AMPD
Threshold estimation of AMPD 3σped =30ch-> 60 phe -> ~75 MeV
![Page 14: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/14.jpg)
A.Olchevski, JINR (Dubna)
Response & resolution vs Beam Energy
![Page 15: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/15.jpg)
A.Olchevski, JINR (Dubna)
![Page 16: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/16.jpg)
A.Olchevski, JINR (Dubna)
- Long term stability - Temperature stabilization for the 9 tower module- Test with COMPASS DAQ& SADC- Tests in muon beam during the COMPASS GPD run to work in real background condition - Tests in 2009 with High Energy Beam H2. Uniformity- Continue collaboration with Zecotek firm ( increase the gain, size, PDE and decrease recovery time)
Plans
![Page 17: A.Olchevski, JINR (Dubna) Test Beam studiesof COMPASS ECAL0 Test Beam studies of COMPASS ECAL0 module prototype with MAPD readout ECAL0 Team, JINR, DUBNA](https://reader035.vdocuments.site/reader035/viewer/2022062401/5a4d1b537f8b9ab0599a87a9/html5/thumbnails/17.jpg)
A.Olchevski, JINR (Dubna)
Acknowledgements
Appreciate very much important opportunity of T9 facility.Thanks to Lau Gatignon for very good beam quality & support.
We gratefully acknowledge the support of the Protvino and Munich groups for presented equipment and readout electronics.
We also thank G.Mallot and A.Magnon for help and support. Special thanks are due to V.Anosov and V. Pessaro for technical
assistance.