“9000” - laser lightinglaserlighting.com.au/web/indoor/novalux/profile/9000.pdf · 2020. 4....
TRANSCRIPT
“9000”
82
The system 9000performs an elegant solu-tion to different applica-tions. It is manufacturedwith a convenient andlinear design allowing theflexibility and versatility ofuse. The ceiling orsuspension fittings maybe installed as modularsystem or as single pointof illumination.The antiglare louvres aredesigned for the needs ofBanks, Insurances andother offices, where themonitors are frequentlyused. The lamellar diffu-
sers are developed for anefficient distribution oflight where is requestedan accurate and comforta-ble illumination as shopsor showrooms.
MaterialsBody in zinc coated steelWhite or grey.Base in white zinc coatedsteel.Ending parts ABS samecolour of the body.Reflector in white zinccoated steel.Low luminance alumi-nium louvre (included)
or modular opal lamellarscreens (separately sup-plied).Included accessories: forcontinuous line mounting.Fluorescent lamps are notincluded.
WiringStarter wiring 230V-50Hzwith power factor correc-tion, electrical compo-nents with ENEC approval.Rigid cable H05V2-U section0,75 mm2 (CEI 20-20).Socket terminal 2P+T(section max 2,5 mm2)on both sides with
phase and neutral lineconnected with colouredcables H05V2-U, section1,5 mm2.Wiring on request withelectronic or dimmableballast and/or with emer-gency light.In accordance with stan-dard IEC 598, CEI EN60598-1 CEI 34-21)Emergency wiring inaccordance with standardCEI EN 60598-2-22(CEI 34-22).
“9000” system
“9000”
83
“9000”
84
A9011BI
A9011 BI•GR 1x58 1595 n. 5 A9008A9013 BI•GR 1x36 1295 n. 4 A9008A9015 BI•GR 1x18 685 n. 2 A9008
A9111 BI•GR 2x58 1595 n. 5 A9008A9113 BI•GR 2x36 1295 n. 4 A9008A9115 BI•GR 2x18 685 n. 2 A9008
BI
GR
L
90
185
pag. 338CL I IP20 FD
G13
Code Lamps L Completion screenWatt mm
Code Lamps L Completion screenWatt mm
Single lamp light fittings direct light forT8 lamps for lamellar screens.
Modular screens (separately supplied)in opal lamellar.
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
Without diffuser
“9000”
85
A9311GR
A9311 BI•GR 3x58 1595 n. 5 A9108A9313 BI•GR 3x36 1295 n. 4 A9108A9315 BI•GR 3x18 685 n. 2 A9108
BI
GR
L
90
300
pag. 339CL I IP20 FD
G13
Without diffuser
Code Lamps L Completion screenWatt mm
Doule lamp light fittings direct light forT8 lamps for lamellar screens.
Modular screens (separately supplied)in opal lamellar.
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
86
309
135
309
250
“9000” Screens
Code Indications
Opal Lamellar Screen.Modular opal lamellar screen to be snappedonto the base.
Code Indications
Opal Lamellar Screen.Modular opal lamellar screen to be snappedonto the base.
A9008 for 9000 system single or double
A9108 for 9000 system with 3 lamps
“9000”
87
A9591BI
A9591 BI•GR 1x58 1595A9593 BI•GR 1x36 1295A9595 BI•GR 1x18 685
A9511 BI•GR 1x58 1595A9513 BI•GR 1x36 1295A9515 BI•GR 1x18 685
BI
GR90
185 L
pag. 339-340CL I IP20 FD
G13
Code Lamps L high gloss lowWatt mm luminance louvre
Code Lamps LWatt mm matt low luminance louvre
Single lamp light fitting direct light forT8 lamps, gloss or matt dark light lou-vre.
Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
“9000”
88
A9491GR
A9491 BI•GR 1x58 1595A9493 BI•GR 1x36 1295A9495 BI•GR 1x18 685
A9411 BI•GR 1x58 1595A9413 BI•GR 1x36 1295A9415 BI•GR 1x18 685
BI
GR90
185 L
pag. 339CL I IP20 FD
G13
Code Lamps L high gloss lowWatt mm luminance louvre
Code Lamps LWatt mm matt low luminance louvre
Single lamp light fitting direct/indirectlight for T8 lamps, gloss or matt lowluminance louvre.
Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
luce diretta/indiretta
“9000”
89
A9691BI
A9691 BI•GR 2x58 1595A9693 BI•GR 2x36 1295A9695 BI•GR 2x18 685
A9611 BI•GR 2x58 1595A9613 BI•GR 2x36 1295A9615 BI•GR 2x18 685
BI
GR
90
300 L
pag. 340CL I IP20 FD
G13
Code Lamps L high gloss lowWatt mm luminance louvre
Code Lamps LWatt mm matt low luminance louvre
Double lamp light fitting direct lightfor T8 lamps, gloss or matt low lumi-nance louvre.
Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
“9000”
90
“9000”
91
“9000”
92
A9791GR
A9791 BI•GR 2x58 1595A9793 BI•GR 2x36 1295A9795 BI•GR 2x18 685
A9711 BI•GR 2x58 1595A9713 BI•GR 2x36 1295A9715 BI•GR 2x18 685
BI
GR
90
300 L
pag. 340-341CL I IP20 FD
G13
luce diretta/indiretta
Code Lamps L high gloss lowWatt mm luminance louvre
Code Lamps LWatt mm matt low luminance louvre
Double lamp light fittingdirect/indirect light for T8 lamps, glossor matt low luminance louvre.
Louvre low luminance high gloss or mattparabolic louvre in aluminium 99,9%anodized with transverse parabolic bla-des completely closed in the upper part.Very high performance, antiridescent,luminance <200 cd/m2 for angles >65°transversal and longitudinal (EN 12464-1).
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
93
A9021BI
A9021 BI•GR 1595A9023 BI•GR 1295A9025 BI•GR 685
A9321GR
185
L90
300L
90
BI
GR
BI
GR
A9321 BI•GR 1595A9323 BI•GR 1295A9325 BI•GR 685
“9000” Accessories
Code Lmm
Colours
Colours
Empty module.Spacing unit, white or grey.
Code Lmm
Empty module.Spacing unit, white or grey.
94
A9000 1200A9000/M3 3000
LL
76 185
193 300
A9001 1200 3x1,5A9001 2A 1200 4x1,5A9001/M3 3000 3x1,5A9001/M3 2A 3000 4x1,5
A9002
A9003
“9000” Accessories
Code Lmm
Suspension.2 steel cables.
Code L Wire of alim.mm
Cable suspension. 2 steel cables; 1 supply cable.
Code
Accessory for ceiling fixing.Accessories for ceiling fixing (mm. 185) twopieces in one box.
Code
Accessory for ceiling fixing.Accessories for ceiling fixing (mm. 300) twopieces in one box.
95
L 127
A9401 1535 for art. A9411..A9403 1235 for art. A9413..A9405 625 for art. A9415..
242L
BI
GR
BI
GR
A9701 1535 for art. A9711..A9703 1235 for art. A9713..A9705 625 for art. A9715..
A9005 BI•GR
A9006 BI•GR
“9000” Accessories
Code L Indicationsmm
Colours
Colours
Dust protection for dark light fittingsdirect/indirect light versions.Transparent plastic, dust protection.
Code L Indicationsmm
Dust protection for dark light fittingsdirect/indirect light versions.Transparent plastic, dust protection.
Code
Joint.Angular joint.
Code
Joint.Circular angular joint.
“9000”
96
A9653GR
A9653 BI•GR 3x36
BI
GR
90
484
484
pag. 341CL I IP20 FSD
2G11
Code LampsWatt matt low luminance louvre
Three lamps light fitting direct light forPhilips compact fluorescent lamps,matt low luninance louvre.
Louvre low luminance matt paraboliclouver in aluminium 99,9% anodizedwith transverse parabolic blades comple-tely closed in the upper part. Very highperformance, antiridescent, luminance < 200 cd/m2 for angles > 65° transver-sal and longitudinal (EN 12464-1).
Wiring on request
A ____ /E one lamp emergency continuous light with magnetic ballast
EL______ 220-240V 50-60Hz electronic ballast EL____ /E one lamp emergency continuous
light with electronic ballastED______ 220-240V 50-60Hz electronic
dimmable ballast (see price list page 4)ED____ /E one lamp emergency continuous
light with dimmable ballast(see price list page 4)(not included 1x14W and 1x24W)
Colours
97
“9000”
For the side shown installation use jointA9005.. 90° angle.
For the side shown installation find thejoints inside the fixture.