MAY 2015 • LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA 30 Many lubricants such as gas turbine oils, biogas engine oils and polyurea- based grease depend on antioxidants to protect the base oil against se- vere oxidation and degradation. To provide improved protection, especially in thermally stressful environments, antioxidant chemistry has undergone a major transition in the last 10 years. Good examples are the change from mono-type antioxidant mixtures to synergistic mixtures of antioxidants, and the introduction of primary (radical scavengers) antioxidants to re- place peroxide catchers such as zinc dithiophosphates. Antioxidants Signal Lubricant Health By Greg Livingstone and Jo Ameye Editor’s Note: This article is based on a presentation by the authors at the OilDoc Conference in Rosenheim, Germany, January 27-29, 2015.

Upload: others

Post on 16-Jun-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

MAY 2015 • LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA30

Many lubricants such as gas turbine oils, biogas engine oils and polyurea-based grease depend on antioxidants to protect the base oil against se-vere oxidation and degradation. To provide improved protection, especially in thermally stressful environments, antioxidant chemistry has undergone a major transition in the last 10 years. Good examples are the change from mono-type antioxidant mixtures to synergistic mixtures of antioxidants, and the introduction of primary (radical scavengers) antioxidants to re-place peroxide catchers such as zinc dithiophosphates.

Antioxidants Signal Lubricant Health

By Greg Livingstone and Jo Ameye

Editor’s Note: This article is based on a presentation by the authors at the OilDoc Conference in Rosenheim, Germany, January 27-29, 2015.

Page 2: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

31

Due to these evolutions, original equipment manufacturers and international standardization organizations have developed and implemented state-of-the-art testing methods that enable equipment users to monitor the life of their in-service lubricants. One reliable method for measuring antioxidant health is voltammetry, also known as the Ruler technique. This method provides an in-depth understanding of the condition, as well the degrada-tion mechanisms, of oils.

Introduction to Antioxidants Oxidation is the predominant

reaction a lubricant undergoes in service, and it accounts for significant lubricant reliability and life problems. Oxidation is the major source of viscosity increase, varnish formation, sludge and sediment formation, additive depletion, base oil break-down, filter plugging, loss of foam resistance, loss of demulsibility, acid number increase, rust and corrosion. Therefore, understanding and con-trolling oxidation is a major concern for the lubricant formulator.

Many tests are used to study the

oxidation behavior of new fluids, including ASTM D2272 (RPVOT), D4310 (sludging), D943 (TOST) and D6514 (UOT). In-service oil analysis to measure the effects of oxidation include ASTM D6971 (Ruler), D7843 (MPC) and D664 (acid num-ber). All these tools are an attempt to understand the fluid’s behavior to this lubricant nemesis.

Virtually every lubricant formula-tion contains antioxidants. These additives are designed to be sacrifi-cial, meaning they oxidize before any other component of the lubricant, thereby protecting it. This oxidative protection is the only thing saving the lubricant from premature failure.

Oxidation was originally defined as a reaction involving combination with oxygen. However, its definition has now been expanded to include any reaction in which electrons are transferred from a molecule. Iron rusting is a form of oxidation, where the reaction is between oxygen and iron. Combustion is a very rapid form of oxidation of a hydrocarbon producing water and carbon dioxide.

The typical final product of oxidation in slower reactions of a

Ruler instrument indicates anti-oxidant level.

Page 3: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

MAY 2015 • LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA32

hydrocarbon is an acid. Hydrocar-bon oxidation to an acid involves complex steps where many different compounds are produced. When a hydrocarbon is allowed to oxidize without control (such as in an oxida-tion experiment like ASTM D2272), carbon dioxide and water are pro-duced, just like in combustion.

The oxidation of a hydrocarbon involves three steps: initiation, propa-gation and termination. This process is followed by a condensation/rearrangement step that also in-creases a lubricant’s viscosity and the insolubility of the by-product. The onset of oxidation can be controlled by limiting the source of oxygen, shortening the number of reaction cycles or adding alternate stopping methods. All of these methods are employed to some extent in lubricant formulations.

The oxidation initiation step is

how it all starts. The faster or more common this step, the higher degree of oxidation the lubricant will experience. Initiation consists of the formation of a free radical, a molecu-lar fragment having one or more un-paired electrons that are accessible to easily react with other hydrocarbons. Free radicals are usually short-lived and highly reactive.

After a free radical has been formed, it can propagate the oxida-tion sequence. This step involves the formation of additional alkyl or peroxy radicals to continue the cycle of radical formation. Antioxidants break into the propagation step to terminate the process by forming stable radicals.

Types of AntioxidantsAntioxidants protect the base oil

by either scavenging radicals or decomposing hydroperoxides into

stable products. Two main categories of antioxidants are available in the industry: primary and secondary.

Primary antioxidants act by remov-ing the radicals and are better known as radical scavengers. Amines and phenols are common types of pri-mary antioxidants and have a typical concentration of 0.3 to 0.7 percent in turbine oils.

Secondary antioxidants eliminate peroxides (hydroperoxide decompos-ers) to form nonreactive products that do not participate in further oxidation. Zinc dithiophosphates and sulfurized phenols belong to this class of antioxidants. Typical con-centrations of zinc dithiophosphates antioxidants in automotive crankcase lubricants reach a maximum of 1.5 percent. Carbamates are also used as secondary antioxidants, and sulfu-rized carbamates provide additional antiwear protection.

u SWEDISH QUALITY PRODUCTS The Hugo Cartridge is a specially developed packaging for grease. It is manufactured in a standard size for 400 g grease guns but can also be used in some 500 g grease guns. Our cartridges and caps are 100 % recyclable.

u SAFE AND SIMPLE HANDLING The injection-moulded cartridge guarantees consistent quality and high stability. The bottom has an inner seal that locks with the pull cap and the outer edge prevents the cartridge from slipping. The leak-proof pull cap secures the content during fi lling, transport

and storage. The cartridge can be fi lled with hot grease, up to 70 °C. The pull cap is easily removed using the pull ring. The cartridge can also be resealed by replacing the pull cap. Seals at both ends guarantee a fully sealed, leak-proof operation. For lubrication of open surfaces, The Hugo Cartridge is used with a Hugo Grease Applicator.

u PRINTING UP TO SIX COLOURSThe Hugo Cartridge has a very smooth surface that is ideal for advanced screen printing. Designs of your choice can be printed with up to six colours.

The Hugo Cartridge™ System

GR PRODUKTER AB, UBBARP, SE–560 30 TENHULT | T +46 (0)36 920 40 | F +46 (0)36 925 82 | [email protected] | WWW.HUGOCARTRIDGE.COM

ON THE MARKET SINCE 1992

Page 4: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA • MAY 2015 33

Continued on page 36

Mixed antioxidant systems add two or more antioxidants to a fluid, typically providing increased antioxi-dant effect in excess of that provided by either additive individually. For this reason, antioxidants are often

used in synergistic mixtures to extend lubricant life.

In a mixed system, one antioxidant sacrifices itself to preserve and regenerate the other. An example of this behavior is the synergy between

amines and phenols where the phe-nol depletes early while the amine is more stable. Another example is the combination of primary and second-ary antioxidants that remove both

700

800

600

500

400

300

200

100

00 2

Amine

Time (seconds)

Rule

r Val

ue

4 6

5.8 7.557.55 11.5

8 10 12 14 16

Ruler graphs trending the life of in-service diesel oils show the formation of oxida-tion products and deple-tion of amines and ZDDP. Oxidation products can be produced even though there is still antioxidant support remaining in the fluid.

Source: Fluitec

ZDDP Oxidationproducts

INDEPENDENT MARKETER OF SPECIALITY OILS & FLUIDS

WE START BY UNDERSTANDING YOUR PROBLEM

SIP is an independent marketer of speciality oils and fluids. We reliably deliver specified product solutions backed by wide-ranging technical and industry expertise.SIP uses its extensive application knowledge to specify, develop & supply speciality oils and fluids. We supply a wide variety of customers from niche formulators to multinational corporations in over 30 countries.

SIP’s comprehensive range of speciality base oils and fluids are used in a variety of applications including:

• Offshore exploration drilling fluids• Pharmaceuticals and personal

care products• Premium industrial lubricants • White process oils • Automotive lubricants

To see how we could help your business call 0044 (0)20 7717 0100 or visit www.sip.comSIP Ltd, Westminster Tower, 3 Albert Embankment, London SE1 7SP, United Kingdom

SIP5043_Lubes+Greases_1-2Page.indd 1 15/12/11 15:52:59

Page 5: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

MAY 2015 • LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA36

Continued from page 33

Continued on page 38

radicals and hydroperoxides.

Measuring AntioxidantsThe method for monitoring the

amount of antioxidants in lubricants is based on voltammetric analysis where a small sample is extracted with an electrolyte in solvent and placed in an electrolytic testing solu-

tion. Results are based on current, voltage and time relationships in a three-electrode sensing system. The dissolved antioxidants oxidize electrochemically (lose an electron) based on their oxidation potential, resulting in an oxidation reaction that can be used to predict the remaining useful life of a grease or fluid.

As described by ASTM test meth-

ods D6810, D6971 and D7520, the voltammetric method is performed with a commercially available voltammograph called the Ruler. This instrument can be used both in the laboratory and in the field.

With the wide variety of antioxi-dants available today, it is important to select the appropriate mixture of electrolytes, which acts as a carrier for the electric current to the different antioxidants. Commercial electro-lytes solutions can be divided into three categories.

Neutral electrolytes mixtures are for amines, ZDDP and phenols. Basic electrolyte mixtures are used for phenolic antioxidants. Acidic electrolyte mixtures are specifically for overbased formulations (engine oil containing phenates and salicy-lates) where the overbasing is reacted to leave the original phenol to be analyzed. This electrolyte mixture detects ZDDP, phenols and amines.

Correlation to Other Methods During the last decade, synergistic

mixtures of antioxidants have been introduced as the way to meet increased lubricant performance requirements. Consequently, the industry needs new test methods to better monitor the remaining activity of these antioxidants. The knowledge gained helps OEMs and standardization organizations be more proactive by understanding the lubricant degradation process, rather than to set action limits based simply on oxidation testing.

Oxidation test methods such as the Rotating Pressure Vessel Oxida-tion Test (RPVOT) and Pressurized Differential Scanning Calorimetry (PDSC) can provide information that is indirectly linked to the measure-ment of antioxidants. The correlation between RPVOT and voltammetric methods has been the subject of sev-eral research projects that show good

Page 6: Antioxidants Signal Lubricant Health - zaupisecke.za.net/Antioxidants.pdf · of antioxidants are available in the industry: primary and secondary. Primary antioxidants act by remov-ing

MAY 2015 • LUBES‘N’GREASES EUROPE-MIDDLE EAST-AFRICA38

Continued from page 36

correlation for phenolic formulations in API Group I oils.

However, there is less correlation between voltammetry and other indirect measurements for synergistic mixtures of phenol-amines and long-life Group II oils. Rather, voltammet-ric techniques provide more accurate results, faster data acquisition and a more thorough understanding of the oxidative health of the fluid.

Ruler technology can be used as a trending tool for any lubricant ap-plication using antioxidants. General guidelines for interpreting results for turbine, compressor and other rust and oxidation oils are:

• Amine only formulations: Warn-ing limit at 50 percent remaining, condemning limit at 25 percent.

• Phenol only formulations: Warn-ing limit at 50 percent remaining, condemning limit at 25 percent.

• Amine-phenol formulations: Warning limit when amines are at 50 percent remaining, condemn-ing limit when amines are at 25 percent.

• Amine-phenol depletion ratios:

Under oxidative conditions, phe-nols regenerate amines, thereby depleting first. If amines are depleting at the same rate or faster than phenols, water is entering the reaction, causing this unusual mode of degradation.

Future Trends In situ replenishment of antioxi-

dant packages for in-service turbine oils has been proven to be an effec-tive method of extending oil life, provided sufficient up-front testing is done. The Ruler is one of the key tests in qualifying in-service oil for antioxidant replenishment and in monitoring the fluid once it is in use.

As an example, Ruler results from two turbine oil antioxidant replenish-ment qualification tests are showed that replenishment had the desired effect of increasing antioxidant concentration in one case but not in the other. It is important to note that several other performance tests are necessary before an oil can be quali-fied for antioxidant addition.

When adding antioxidants to in-service turbine oils, Ruler testing is a

critical tool to monitor the depletion of these additives. Ideally, refortified antioxidants should deplete at a rate similar to that of antioxidants in new turbine oils.

Antioxidant monitoring can be performed in a multitude of lubri-cants, ranging from jet turbine oils to natural gas engine oils to hydraulic fluids. And appropriate electrolytic testing solutions have been designed to accommodate the spectrum of lubricant formulations. As in any oil analysis, tracking trends is crucial, and understanding the health of the individual antioxidants in the oil can also trigger supporting analytical tests. o

Plot shows the correlation among different oxidation tests.

Source: Fluitec

50 15

40 12

30 9

20 6

10

0

0 24 48 72 96

3

0

% R

uler

Oil

Hours

SAE 5W-30 Isothermal Corrosion Oxidation Tests

PDSC (% residual inhibitor)

HPLC (% residual additive)

Ruler (% residual additive)

Acid Number (mg KOH/g)

PAI (value x 100)

Greg Livingstone is Executive Vice President Business Development for Fluitec International LLC, located in Tuscon, Arizona, United States. Contact him at [email protected]. Jo Ameye is General Manager Europe, for Fluitec International LLC, located in Antwerp, Belgium. Contact him at [email protected].