Antifrogen® -SOLarfluids HTFs in solar thermal systemsAHK – Exportinitiative Erneuerbare Energien, Turkey, Feb. 22nd 2010
Group overview
� Clariant is a global leader in the field of specialty chemicals
� It has approximately 17 000 employees and posted annual sales of about
CHF 6,6 billion for 2009
� The group operates worldwide with more than 100 companies
on five continents
� It is domiciled and headquartered in Muttenz near Basel/Switzerland
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 2February 2010
Public: Antifrogen - Heat Transfer Fluids
� It is domiciled and headquartered in Muttenz near Basel/Switzerland
� The products and services of its 10 Business Units are based on
innovative specialty chemicals
� These products and services play a decisive role in our customers’
manufacturing processes and upgrade their finished products
Clariant History
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 3February 2010
Public: Antifrogen - Heat Transfer Fluids
Clariant Executive Committee (EC) –Tasks and Resposibilities
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 4February 2010
Public: Antifrogen - Heat Transfer Fluids
Group Finance and
Group IT
Patrick JanyChief Financial Officer
(CFO)
Clariant Excellence,
Group Legal &
Compliance, Group HR ,
Group Communications
and Corporate
Development
Hariolf KottmannChief Executive Officer
(CEO)
Industrial & Consumer
Specialties, Textile
Chemicals, Oil & Mining
Services and Leather
Services BUs. Group
Procurement and Supply
Chain Management
Mathias LütgendorfMember of Executive
Committee
Pigments, Masterbatches,
Paper Specialties,
Detergents &
Intermediates, Additives
and Emulsions BUs.
Group Technology and
ESHA
Christian KohlpaintnerMember of Executive
Committee
Clariant Business Units
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 5February 2010
Public: Antifrogen - Heat Transfer Fluids
Clariant global
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 6February 2010
Public: Antifrogen - Heat Transfer Fluids
� Clariant present in over 100 countries
� Investments in growth regions
� Global production and safety standardsCountries where Clariant is represented
Principle: Solarthermic systemsWhy do we need heat transfer fluids ?
Frost protection,
Corrosion protection &
high temperature loads!!
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 7February 2010
Public: Antifrogen
„Captured“ solar energy heats up a
transmitting agent (the heat transfer fluid)
flowing through the solar collector
which is than used eg. for generation of
domestic hot water.
Why do I need Frost protection?
� Force of frost on …
Hard soldered Cu-pipe PVC-pipe
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 8February 2010
Public: Antifrogen - Heat Transfer Fluids
Source: Sanitär + Heizungstechnik – 6/2007.
Inflated Cu-pipesMulti layer connection pipe (laboratory test)
Why I need corrosion protection?
corrosion
Pipe infarct
Insulating coverings
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 9February 2010
Public: Antifrogen - Heat Transfer Fluids
Source: Heizung Lüftung Klimatechnik – 5/2007.
corrosionPittingPlugged fittings
� Efficency of collectors is increasing
maximum temperature loads in collectors:
+250 °C flat collector
+300 °C (and higher) vacuum tube collector
Why do I need a thermal stable heat transfer fluid?
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 10February 2010
Public: Antifrogen
� Solar systems should generate efficient heat at lower sunshine (spring & autumn)
High loads in summer
� High temperatures can destroy (crack) corrosion inhibitors and the glycol
component of the heat transfer fluid
What can happen, when the HTF is cracked?
� Corrosion inhibitors can be destroyed as well
� Cracking of glycols can lead to the formation of insoluble precipitations
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 11February 2010
Public: Antifrogen
A brown coloration of the fluid shows
overheating of it. But it can be still
usable.
New testing of fluids at high temperatures
� Sealed high temperature test:
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 12February 2010
Public: Antifrogen
When can these overheating precipitations occcur?
� Tests at elevated temperatures (up to 270°C) showed that high boiling glycols are
more resistant to thermal stress than mono propylene glycol.
� Currently nearly all solar heat transfer fluids are based on mono propylene glycol
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 13February 2010
Public: Antifrogen
� Based on these results Antifrogen SOL HT was developed with high boiling glycols
as the freezing protecting component.
Which properties have new solar fluids?
� Alternatives to „regular glycol“:
Used glycolsMonopropylene
glycol
High boiling
glycol
Boiling point +187 °C min. +270 °C
Toxicity none none
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 14February 2010
Public: Antifrogen
Toxicity none none
Environmental impact ok ok
®Antifrogen SOL HTNew!
Standard solar fluids
Test results: summary
� Antifrogen SOL HT showed improved thermal resistance in comparison to mono
propylene glycol based heat transfer fluids
� Additionally the results showed that the corrosion additives are stable at elevated
temperatures.
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 15February 2010
Public: Antifrogen
temperatures.
Antifrogen Distributor for Turkey
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 16February 2010
Public: Antifrogen
Antifrogen® - contact:
Site Gendorf
Achim Stankowiak, Head of Application, Engineering & Aviation (Copyright Clariant. All rights reserved.) Slide 17February 2010
Public: Antifrogen - Heat Transfer Fluids
Dr. Achim Stankowiak
Clariant Produkte (Deutschland) GmbH
Werk Gendorf
Application Engineering & Aviation
D-84504 Burgkirchen
Tel.: 0049-(0)8679-7-2272
Fax: 0049-(0)8679-7-5085
www.antifrogen.com
Public
Head of Application
Engineering & Aviation
Achim Stankowiak
February 2010
Public
Achim Stankowiak
Head of Application
Engineering & Aviation
February 2010
Thank You! -Questions?