analysis report. structural
TRANSCRIPT
TIT
LE
S
HE
ET
T-1
CROWN CASTLE
3530 TORINGDON WAY, SUITE 300
CHARLOTTE, NC 28277
JEFFREY BALL
(713) 899-1660
TOWER ENGINEERING PROFESSIONALS
326 TRYON ROAD
RALEIGH, NC 27603
GRAHAM M. ANDRES, P.E.
(919) 661-6351
T-MOBILE
185 FAIRCHILD STREET
CHARLESTON, SC 29492
SC OFFICE
(843) 216-1210
LESSEE:
TOWER OWNER:
SURVEYOR:
CIVIL ENGINEER:
ELECTRICAL ENGINEER:
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
PROPERTY OWNER:
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
TOWER ENGINEERING PROFESSIONALS
326 TRYON ROAD
RALEIGH, NC 27603
MARK S. QUAKENBUSH, P.E.
(919) 661-6351
N/A
N/A
N/A
N/A
N/A
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
EQUIPMENT
INSTALLATION
T-MOBILE SITE ID:
PROJECT
DESCRIPTION:
TOWER TYPE:
SITE ADDRESS:
125'± MONOPOLE
5CT1032A
DISTURBED AREA:
PRESENT
OCCUPANCY TYPE:
CURRENT ZONING:
PARCEL ID #: 08015203
R-22MF
TELECOMMUNICATIONS
FACILITY
615 SEIGLE AVENUE
CHARLOTTE, NC 28204
(MECKLENBURG COUNTY)
POWER COMPANY:
CONTACT:
PHONE:
METER # NEAR SITE:
TELEPHONE COMPANY:
CONTACT:
PHONE:
PHONE # NEAR SITE:
PEDESTAL # NEAR SITE:
N
GENERAL NOTES
UTILITY INFORMATIONTOWER COORDINATES CODE COMPLIANCE
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS
ADOPTED BY THE LOCAL GOVERNING AUTHORITES. NOTHING IN THESE PLANS
IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE LATEST
EDITIONS OF THE FOLLOWING:
1. NORTH CAROLINA BUILDING CODE
(2012 EDITION)
2. NORTH CAROLINA CODE COUNCIL
3. ANSI/TIA-222-G-2009
4. 2014 NCEC
(NEC 2014 & ADDENDUM)
5. LOCAL BUILDING CODE
6. CITY/COUNTY ORDINANCES
CONTACT INFORMATION
PROJECT INFORMATION
120 SF
INDEX OF SHEETS
DRIVING DIRECTIONS
LOCATION MAP
DIRECTIONS FROM CROWN CASTLE DISTRICT OFFICE: GET ON I-485 INNER FROM JOHNSTON ROAD. CONTINUE ON I-485
INNER. TAKE I-77N TO EAST 11TH STREET. TAKE EXIT 3A FROM I-277. CONTINUE ON E 11TH STREE AND TURN RIGHT ON
SEIGLE AVENUE. SITE WILL BE ON THE RIGHT.
LATITUDE
LONGITUDE W 80° 49' 39.40" *
N 35° 13' 22.30" *
GROUND ELEV. (AMSL) = 740'± AMSL**
*INFORMATION PROVIDED BY CROWN CASTLE
**INFORMATION PROVIDED BY GOOGLE EARTH
BELL SOUTH
CUSTOMER SERVICE
(800) 252-0803
(704) 537-9275
UNKNOWN
DUKE POWER
CUSTOMER SERVICE
(704) 594-9400
077 591 960
SHEET DESCRIPTION REV
185 FAIRCHILD STREET
CHARLESTON, SC 29492
JURISDICTION: CITY OF CHARLOTTE
CROWN CASTLE SOUTH INC
PMB 353 4017 WASHINGTON RD
MCMURRAY, PA 15317
UNKNOWN
UNKNOWN
NAME:
ADDRESS:
CITY, STATE, ZIP:
CONTACT:
PHONE:
MECKLENBURG COUNTY NOTES
1. THE STRUCTURAL ANALYSIS REPORT MUST COMPLY WITH THE 2009 ANSI/TIA-222-G STANDARD AND THE 2012
NCBC/2009 IBC CODES.
3530 TORINGDON WAY, STE 300
CHARLOTTE, NC 28277
CROWN SITE ID: 813223
CROWN SITE NAME:
ALEXANDER-HILL 074-005
T-MOBILE SITE ID: 5CT1032A
615 SEIGLE AVENUE
CHARLOTTE, NC 28204
(MECKLENBURG COUNTY)
SITE TYPE:
TECHNOLOGY TYPE:
CABINET TYPE:
BACKHAUL TYPE: TELCO/FIBER
RBS 6102 AND PPC
ERICSSON
PROPOSED EQUIPMENT
Building and Electrical,permits are requiredfor this project.
Structuralmodificationdrawings to thistower areattached to theStructuralAnalysis Report.
Zoning Plan Review: Please provide detail of existingprivacy fence. New equipment must be screened frompublic view.
AP
PE
ND
IX
B
- 1
T-2
APPENDIX B - 1
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
E
Q
U
I
P
M
E
N
T
R
A
C
K
O
N
L
Y
N
/
A
The issuance of a permit or approval ofplans or specifications shall not bedeemed or construed to be a permit foran approval of any violation of any ofthe provisions of the North CarolinaState Building Codes or localordinances.
Building review approved byCraig Sloop
Building Plans ExaminerMecklenburg County Code Enforcement
If you have any questions about the required type of inspections, please contact the appropriate inspections team which is listed on your permit.
Residential & Mega Team: 980-314-3134Commercial Team: 980-314-3127
The issuance of a permit or approval ofplans or specifications shall not bedeemed or construed to be a permit foran approval of any violation of any ofthe provisions of the North CarolinaState Building Codes or localordinances.
Electrical review approved byCraig Sloop
Electrical Plans ExaminerMecklenburg County Code Enforcement
If you have any questions about the required type of inspections, please contact the appropriate inspections team which is listed on your permit.
Residential & Mega Team: 980-314-3134Commercial Team: 980-314-3127
E
Q
U
I
P
M
E
N
T
R
A
C
K
O
N
L
Y
N
/
A
AP
PE
ND
IX
B
- 2
T-3
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
APPENDIX B - 2
FEEDLINE
LENGTH
E-TILT
MOUNTING
HEIGHT
MANUFACTURER
(MODEL #)
POS
ANTENNA/COAX SCHEDULE:
SECTOR
TRUE
AZM.
FEEDLINE
SIZE
NOTES:
RRU
97DB_1XAIR SITE CONFIGURATION
LEGEND
S
E
I
G
L
E
A
V
E
.
SIT
E P
LA
N &
TO
WE
R E
LE
VA
TIO
N
C-1
SITE PLAN COMPOUND DETAIL
ANTENNA PLAN VIEW @ 107' TOWER ELEVATION
ANTENNA/COAX SCHEDULE
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
NOTE:
NOTES:
NOTES:
NOTES:
SIDE VIEW FRONT VIEW REAR VIEW
SIDE VIEW
PLAN VIEW
FRONT VIEW
FOUNDATION NOTES:
FRONT VIEW
SIDE VIEW
NOTE:
EQ
UIP
ME
NT
L
AY
OU
T
PL
AN
&
C
IV
IL
D
ET
AIL
S
C-2
ICE BRIDGE DETAIL / COAX / GROUND BAR ELEVATION ICE BRIDGE DETAIL
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
PPC CABINET DETAILS
EQUIPMENT LAYOUT PLAN
FOUNDATION PLAN
RBS 6102 CABINET DETAILS WESTELL BOXER DETAILS
SECTION
NOTES:
NOTES:
ONE-LINE DIAGRAM NOTES:
NOTES:
UL NOTE:
NOTES:
FRONT ELEVATION VIEWPLAN VIEW
CODES
TESTING
GUARANTEE
CO-ORDINATION:
EXAMINATION OF SITE
CUTTING, PATCHING AND EXCAVATION:
SCOPE:
ELECTRICAL NOTES:
CONDUCTORS
GROUNDING
PENETRATIONS:
EXTERIOR CONDUIT:
EQUIPMENT:
RACEWAYS
ABBREVIATIONS AND LEGEND
ONE-LINE DIAGRAM
UTILITY ROUTING PLAN
EL
EC
TR
IC
AL
N
OT
ES
,
UT
IL
IT
Y R
OU
TIN
G &
RA
CK
D
ET
AIL
S
E-1
T-MOBILE PPC RACK DETAIL
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
GENERAL NOTE:
UTILITY ROUTING PLAN
New Service
NOTE:
NOTE:
NOTES:
TOP VIEW
SIDE VIEW
NOTE:
END VIEW
COPPER-CLAD STEEL GROUND ROD DETAIL
EQ
UIP
ME
NT
G
RO
UN
D
PL
AN
, G
RO
UN
DIN
G
NO
TE
S &
D
ET
AIL
S
E-2
EQUIPMENT GROUNDING PLAN
LOWER GROUND BAR DETAIL LUG DETAIL
UPPER / INTERMEDIATE GROUND BAR DETAILCADWELD GROUNDING DETAIL
STANDARD GROUND BAR DETAIL
GROUND ROD WITH INSPECTION WELL DETAIL
GROUND BAR IN TELCO CABINET DETAIL
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
DRAWING NOTES:
GROUNDING NOTES:
NOTES:
PPC SCHEDULE
ØBØA
LOAD SERVEDNO.
AMP /
POLEVAVA
ØB ØA
LOAD SERVED NO.
AMP /
POLE VA VA
NOTE:
NOTE:
NOTE:
NOTES:
PPC SCHEDULE
GR
OU
ND
IN
G
DE
TA
IL
S
E-3
0
AL
EX
AN
DE
R-H
IL
L
07
4-0
05
TM
O S
IT
E ID
: 5
CT
10
32
A
CR
OW
N ID
: 8
13
22
3
MW
SANK
69599.6
4240
Feburary 17, 2017
002-1
7-1
7CO
NSTR
UCTI
ON
CABLE GROUNDING DETAIL
GROUND WIRE TO GROUND BAR CONNECTION AT ANTENNA DETAIL
ANTENNA CABLE & GROUNDING SCHEMATIC
CADWELD DETAILSUNDERGROUND CONDUIT(S) TRENCHING DETAIL
130.5 A