analysis of breakdown data from xbox-1

35
Analysis of breakdown data from Xbox-1 A. Degiovanni 04.02.2014

Upload: sancha

Post on 22-Feb-2016

55 views

Category:

Documents


0 download

DESCRIPTION

Analysis of breakdown data from Xbox-1. A. Degiovanni 04.02.2014. TD26R05 CC under test in Xbox-1. Clockwise from top-left: Modulator/klystron (50MW, 1.5us pulse) Pulse compressor (250ns, ratio 2.8) DUT + connections Acc. structure (TD26CC). Gallery. Bunker. Recorded signals. 1.2 ns. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Analysis of breakdown data from Xbox-1

Analysis of breakdown data from Xbox-1

A. Degiovanni04.02.2014

Page 2: Analysis of breakdown data from Xbox-1

Gallery

Bunker

Clockwise from top-left:• Modulator/klystron

(50MW, 1.5us pulse)• Pulse compressor

(250ns, ratio 2.8)• DUT + connections• Acc. structure (TD26CC)

TD26R05 CC under test in Xbox-1

4.2.2014 A.Degiovanni - CLIC Workshop 2014 2

Page 3: Analysis of breakdown data from Xbox-1

Recorded signals

The TRA signal is attenuated and delayed

The REF signal comes directly from the bidirectional coupler, not from the ACS input

67 ns

TRAINREF

AREF

6.3 ns1.2 ns

TD26CCDC2 DC1

hybrid

4.2.2014 A.Degiovanni - CLIC Workshop 2014 3

Page 4: Analysis of breakdown data from Xbox-1

Example of signals – BD detection

Transmitted power drops Reflected power increases

Faraday cup voltages are saturated– typical dark current ~ mA (on FC1

at 0.4m from output coupler)– during BD 100-1000x increase in

charge emitted

To find the BD cell location– We can use the difference in time

between the TRA power drop and the REF power increase;

– the phase information is used to pinpoint cell location.

4.2.2014 A.Degiovanni - CLIC Workshop 2014 4

Page 5: Analysis of breakdown data from Xbox-1

BD location: REF – INC delay

• The structure of the signal in INC power during the pulse tail allows to correlate accurately with the REF signal

• This method allows to precisely subtract the INC phase from the REF phase and also to locate the BD cell (echo method).

INC and REF signals and best fit of REF on INCobtained for a delay of 11 ns and a ratio of 0.58

Test method to derive best fit parameters

4.2.2014 A.Degiovanni - CLIC Workshop 2014 5

Page 6: Analysis of breakdown data from Xbox-1

TD26R05CC normalized BD distribution

Cells nb.

8h. Records nb.

Corrupted files and no powered periods have been removed from the record

time

4.2.2014 A.Degiovanni - CLIC Workshop 2014 6

Page 7: Analysis of breakdown data from Xbox-1

TD24R05 normalized BD distribution

Hot cells (5 and 6) have appeared from record #50The very high peak values are an artifact of the normalization (if only 2 BDs during a record these cells will result very active)

Cells nb.8h. Records nb.

time

4.2.2014 A.Degiovanni - CLIC Workshop 2014 7

Page 8: Analysis of breakdown data from Xbox-1

270 ns pulse length period (636 BDs)

• Test period between the 14th of Nov. and the 5th of Dec. (636 BDs)• Pulse length 270 ns (at 90% of peak power)

4.2.2014 A.Degiovanni - CLIC Workshop 2014 8

Page 9: Analysis of breakdown data from Xbox-1

REF – TRA edges time difference

Input coupling cell

Output coupling cell26 regular cells

Despite difficulties to determine edges,the delays range is consistent with cell bins.

BD ignition

4.2.2014 A.Degiovanni - CLIC Workshop 2014 9

Page 10: Analysis of breakdown data from Xbox-1

About 25% of BDs see a drift in position:• Notch in the Reflected signals • The overall phase change is always negative

BD arc is moving towards the input.

RF Phase analysis

Reflected phase are grouped and separated by 2p/3

4.2.2014 A.Degiovanni - CLIC Workshop 2014 10

Page 11: Analysis of breakdown data from Xbox-1

Phase evolution after INC main pulse

• Slices of 40 ns are used to determine a series of mean phases after the INC main pulse for each BD (small dots marked curves)

• Stable phase (stand. dev. less than 7 deg) are kept (large circles)• For each BD the median of stable phase slices is computed (this procedure permits

to discard the fast phase shift periods)

Example of phase signal after BD

Phase evolution for many BDs

4.2.2014 A.Degiovanni - CLIC Workshop 2014 11

Page 12: Analysis of breakdown data from Xbox-1

Possible explanation of the REF notchesTRA

BD ignition. Plasma development. Wave absorption . TRA drops1/

2/

REF

Plasma density sufficient to reflect the INC wave.REF raises

3/

REF Another BD appears upstream. The second reflected wave combines with the first one in power and phase and can cause destructive interference.

4/

REF

The upstream BD plasma density is sufficient to reflect the INC wave. REF raises again but with a different phase and higher amplitude.

Power is likely to be absorbed before it is reflected. This is impairing the accuracy of BD location methods based on REFup – TRAdown thresholds

4.2.2014 A.Degiovanni - CLIC Workshop 2014 12

Page 13: Analysis of breakdown data from Xbox-1

REF-INC phase vs. delay distribution

• BDs outside accelerating structure

• 3 phase groups are clearly visible

• Unexplained phase drift is noticed (I/Q sensibility to signal strength ?)

4.2.2014 A.Degiovanni - CLIC Workshop 2014 13

Page 14: Analysis of breakdown data from Xbox-1

BDs screening

• Upon the 636 BDs• 183 are located in the waveguide (echo delay < 9 ns) -> discarded• 130 are poorly fitted (quadratic error > 33 %) -> discarded • 333 are kept for further analysis

4.2.2014 A.Degiovanni - CLIC Workshop 2014 14

Page 15: Analysis of breakdown data from Xbox-1

REF-INC phase distribution after screening

120o

106o

• Means are computed on each phase group delimited by minimum phase occurrence.

4.2.2014 A.Degiovanni - CLIC Workshop 2014 15

Page 16: Analysis of breakdown data from Xbox-1

REF-INC phase vs. delay after screening

• Bins for BD location with delay and phase.

• Bins for BD location with delay only

• Cell centers delay and phase positions

4.2.2014 A.Degiovanni - CLIC Workshop 2014 16

Page 17: Analysis of breakdown data from Xbox-1

Effect on BD location histogram

BD location histogram using delay only

BD location histogram using delay and phase (possible 3 cells period)

4.2.2014 A.Degiovanni - CLIC Workshop 2014 17

Page 18: Analysis of breakdown data from Xbox-1

Field scan every 30 minutes

Example of pulse shapes Ramp down-ramp up

15 s, 100% - 75% of maximum power

Peak value during flat-top as average over 20 samples

4.2.2014 A.Degiovanni - CLIC Workshop 2014 18

Page 19: Analysis of breakdown data from Xbox-1

Beta monitoring during operations

Fowler-Nordheim plots for each scan

Evolution of beta value in timebeta enhancement factor ~ 40

4.2.2014 A.Degiovanni - CLIC Workshop 2014 19

Page 20: Analysis of breakdown data from Xbox-1

Conclusion and further studies

Analysis of BD location by time delay and RF phase– TD26R05CC structure conditioned very well, no hot spot detected – Ref phases are grouped and separated by 2p/3

Evaluation of Beta enhancement factor by periodic ramping New diagnostics (and data)

Fast acquisition ADC for DC autocorrelation studies PM for X-rays detection Spectrometer for dark current energy study

Further studies– BD ignition timing and RF phase– Re-calibrate powers for missing energy studies– Compare timings of FCU and PM– Study FCU upstream and downstream complete signals– Post-mortem analysis

250 ns

Preliminar PM signal

4.2.2014 A.Degiovanni - CLIC Workshop 2014 20

Hamamatsu R9880U-01

Page 21: Analysis of breakdown data from Xbox-1

THANK YOU FOR YOUR ATTENTION

4.2.2014 A.Degiovanni - CLIC Workshop 2014 21

Page 22: Analysis of breakdown data from Xbox-1

4.2.2014 A.Degiovanni - CLIC Workshop 2014 22

Page 23: Analysis of breakdown data from Xbox-1

BD cells distribution for the 270 ns pulse

With slow signal (4 ns sampling rate)

With fast signal (1 ns sampling rate)

4.2.2014 A.Degiovanni - CLIC Workshop 2014 23

Page 24: Analysis of breakdown data from Xbox-1

Fast data for DC autocorrelation studies

sampling rate:1.25 Gs/s

4.2.2014 A.Degiovanni - CLIC Workshop 2014 24

Page 25: Analysis of breakdown data from Xbox-1

Histogram of the BD vs. Cells

For TD24R05, BDs in Cells 5 and 6 have raised from the 160 ns pulse length test period and continue to show excess of BDs at 215 ns

TD26CC

4.2.2014 A.Degiovanni - CLIC Workshop 2014 25

Page 26: Analysis of breakdown data from Xbox-1

Conditioning history plot

4.2.2014 A.Degiovanni - CLIC Workshop 2014 26

Page 27: Analysis of breakdown data from Xbox-1

Conditioning history plot – normalized t^1/6

4.2.2014 A.Degiovanni - CLIC Workshop 2014 27

Page 28: Analysis of breakdown data from Xbox-1

RF signals BD# 01 Slow signals (4 ns on Log detectors) provide the BD location according to 4 various methods: (Ref/Out, Ref/FCU, Out/FCU and Ref/In)

FCU signals are saturated during real BDs, but still provide a rather accurate BD time (flying time to the FCU is small for relativistic electrons compared to RF group delay in the structure)

Fast signals (1ns on I/Q) are still not usable for BD location due to a trigger problem (under investigation)

Fast signals provide phase information

REF phase: -60 o from raising edge to peak REF phase: ~ +60 o on the trailing tail

INC phase: slowly raising during the pulse, than fluctuating during the trailing tail4.2.2014 A.Degiovanni - CLIC Workshop 2014 28

Page 29: Analysis of breakdown data from Xbox-1

RF signals BD# 02

Phase drifts about 240o from raising edge to peak REF (1st and 2nd REF pulses).

Accurate REF phase measurement should take into account the INC phase fluctuation, but delay to be determined according to BD location

REF pulse is split in 2 parts that shows 2 different phases

REF/Out and REF/IN methods seems to indicate a BD location drift from BD burst to BD end

4.2.2014 A.Degiovanni - CLIC Workshop 2014 29

Page 30: Analysis of breakdown data from Xbox-1

RF signals BD# 04

Stable RF phase if we consider the INC phase drift.

Then phase jumps about 300o

4.2.2014 A.Degiovanni - CLIC Workshop 2014 30

Page 31: Analysis of breakdown data from Xbox-1

RF signals BD# 05

REF/Out and REF/IN methods : BD location drifts

REF phase jumps about 240o

4.2.2014 A.Degiovanni - CLIC Workshop 2014 31

Page 32: Analysis of breakdown data from Xbox-1

RF signals BD# 35

REF phase jump of 240o

BD location drifts

Followed by many other REF jumps probably linked to INC phase and amplitude jumps

4.2.2014 A.Degiovanni - CLIC Workshop 2014 32

Page 33: Analysis of breakdown data from Xbox-1

REF – TRA BDs edges delays for TD26CC

Input cellFirst regular cell

Output cell

4.2.2014 A.Degiovanni - CLIC Workshop 2014 33

Page 34: Analysis of breakdown data from Xbox-1

Accuracy of the delay measurement

Very low sampling jitter (s = 1 ns )Measured filling time 66 ns (but waveguides length is included) 4.2.2014 A.Degiovanni - CLIC Workshop 2014 34

Page 35: Analysis of breakdown data from Xbox-1

Drift of the BDs

To be continued….