ANALOG THRESHOLD DETECTOR
THRESHOLD RELAY DSL35
• All process and temperature inputs
Volt, mV, mA, Aac, Adc, RMS, TRMS
with or without sensor supply,
potentiometer, frequency,
thermocouple, PT100, CTN, CTP, ....
Namur proximity sensor (IEC 60497-5-6)
Capacitive divisor, strain gauge
• Special inputs Sum, average, difference between 2 inputs
Max or min value selection between 2 inputs
• DSL1-35: 1 threshold / 1 relay (SPDT contact)
• DSL2-35: 2 thresholds / 2 relays (SPDT contact)
• Fast version < 3 ms ref: DSL35T
• Electromechanical relay or solid state output
• Positive or negative safety (selection with internal switch)
• Internal (potentiometer) or external (volt, mA, pot) setpoint
• AC or DC Power supply. from 5Vdc up to 400Vac.
The threshold relay DSL35 allows, for an input value coming from various types of sensors, to define one (DSL1/35) or two independent thresholds (DSL2/35). It design for protection application or simple regulation.
Standard inputs: (type and input range to be define) - thermocouples, all type : B, E, J, K, R, S, T, ... - linearized platinum probes sensor (Pt100, Pt1000, ...) 2, 3 or 4 wires, - voltage (mV, V, Ac and Dc), RMS, - Voltage with high impedance for capacitive divisor - current (mA, A, Ac and Dc), RMS, - resistance 2, 3 or 4 wires, - 3-wires potentiometer (potentiometer reference 0.2, 1, 10 V), - 4-wires strain gauge, commutable sensitivity, 5 V power supply, - sensor power supply, 4/20 mA transmitter in loop powered mode, - NTC, PTC input,... - Proximity sensor NAMUR (IEC 60497-5-6) - Current up to 3000 A with external Hall effect sensor. Special inputs: - sum of 2 non-isolated inputs (mA, V, Tc, Pt100 2 wires), - difference of 2 non-isolated inputs (mA, V, Tc, Pt100 2 wires), - average of 2 non-isolated inputs (mA, V, Tc, Pt100 2 wires), - selection of max or min value on 2 inputs (mV, V, mA), - any others on request. (the inputs are non isolated each other)
Features: - Led for relay state indication (led on = excited coil). - Triggering threshold adjustment (to be defined): 1) Internal with potentiometer (standard) - manual adjustment on free button 3/4 turn (by default), - manual adjustment on button 3/4 turn with axis lock screw - screen driver adjustment on split button 10 turns. 2) External by 0...10 V voltage or remote potentiometer. - "standard" hysteresis 0.5 % of full scale (others on request). - Configuration of each threshold in positive or negative safety (by internal switch on the printed circuit beside the relays). - Symmetrical and asymmetrical DIN rail mounting. - Connection with screw terminal bloc (section wires up to 2.5 mm²). - Conformal coating - Protection rating (enclosure/terminal) : IP20
Version and order code: • DSL1-35: 1 threshold / 1 relay changeover contact • DSL1-35/2R: 1 threshold / 2 relays changeover contact • DSL2-35: 2 thresholds / 2 relays changeover contact
• Option /Ts: Fast version <3ms, 1 NO solid state relay (300Vac-dc 0.1A or 60Vdc 0.5A to define at order) • Option /Te: Fast version <10ms, electromechanical relay, (changeover contact) • Option /cext: External setpoint (0-10V or external potentiometer to define at order) • Option-c10 : setpoint adjustment by screwdriver on split axe 10 turns • Option-cb : setpoint adjustment by button 3/4 turn with lock Special versions (available with 1 or 2 threshold) :
DSL35-SVL: Min or Max value selector between 2 inputs (selection type and input to be define at order)
DSL35-DiF: Difference between 2 inputs (signed difference or absolute value be define at order)
DSL35-SOM: Sum or average of 2 inputs
DSL35-HALL: Current input wit Hall effect sensor (Ac + Dc)
Threshold relay
DSL35/HALL provided with it's remote current sensor. for Ac or Dc current detection, up to 3000A
2 thresholds version with remote HALL effect current sensor
Setpoint: single turn
potentiometer
Setpoint: multi-turn
potentiometer
Setpoint: single turn potentiometer with lock
90 days accuracy (20 °C +/- 2 °C) DATA SHEET CAN BE DOWNLOADED ON WWW.LOREME.FR TECHNICAL SPECIFICATIONS
On account of the constant technologies and standards evolution, LOREME keeps the possibility to modify the specifications of the included products without notice.
E 2 LOREME 12, rue des Potiers d'Etain - 57071 Metz 03.87.76.32.51 - www.loreme.fr - Email: [email protected] - [email protected]
INPUT TYPE RANGE Voltage mV, V,( ac or dc) 5 mV ... 1000 V to be define Impedance > 1 MOhms
Current mA, A, ac, dc 10 µA ... 5 A to be define Input impedance: 50 Ohms (mA) / 0.25 Ohms (1 A) / 0.05 Ohms (5 A)
Pt100, Pt1000 (2, 3 or 4 wires) -200 °C / 800 °C 30°C span mini Thermocouple - B, E, J, K, R, S, T, … 100 °C span mini cold junction compensation -20 to 60 °C
THRESHOLD Setting accuracy +/- 1 % (pot. 3/4 turn) +/-0.2% (pot. 10 turns) Tripping repeatability 0.1 % Standard response time < 250 ms typical (Tc, RTD) Fast version response time < 3 ms typical (mA, Volt)
RELAY free potential change over contact 2500 Vac isolation AC switching power 6 A / 440 V / 1500 VA Type of load lifetime (nbr of operation) 5 A, 250 Vac, resistive 1x105 2 A, 250 Vac, cos phi 0.4 2x105 1 A, 24 Vdc, L / R=48 ms 2x105 6 A, 250 Vac, resistive 7x104 Min. load 100 mA, 12 Vac/dc Input withstand voltage 6000 V (1.2 / 50us)
AUXILIARY Nominal sensor power supply 19 Vdc (smoothed), 22mA Strain gauge power supply 5 Vdc (regulated), 20mA Potentiometer reference (depending on potentiometer) 200 mV, 1 V, 10 V
POWER SUPPLY (to specified at order) 400 Vac 50-60 Hz +/- 10 %, 2.3 VA 230 Vac 50-60 Hz +/- 10 %, 2.3 VA 115 Vac 50-60 Hz +/- 10 %, 2.3 VA
20 to 70 Vac / Vdc, 2 VA 80 to 265 Vac / Vdc, 2 VA
5 - 18Vdc or 9 - 30 Vdc, 2 W
Reverse polarity protected
ENVIRONMENT
Operating Temperature -25 to 60 °C Storage Temperature -40 to 85 °C Influence 0.02 % / °C (% of full scale) Humidity 85 % (not condensed) Dielectric strength 1500 Vac continuous Protection rating IP20 Weight 210 g
MTBF (MIL HDBK 217F) > 2 000 000 Hrs @ 25°C Life time > 150 000 Hrs @ 30°C
Shock CEI 60068-2-27 (operational) 15 G / 11 ms Bump CEI 60068-2-29 (transportation) 40 G / 6 ms Vibrations CEI 60068-2-6 ( operational) 1 G / 10 - 150 Hz Vibrations CEI 60068-2-6 ( transportation) 2 G / 10 - 150 Hz
WIRING AND OUTLINE DIMENSIONS:
1 t
hre
shold
vers
ion w
ith
exte
rnal setp
oin
t 0..
10V
1 t
hre
shold
vers
ion w
ith
exte
rnal pote
ntio
mete
r
2 c
urr
ent
4-2
0m
A in
puts
vers
ion
Electromagnetic compatibility 2014/30/UE / Low Voltage Directive 2014/35/UE
Immunity standard for industrial environments
EN 61000-6-2
Emission standard for industrial environments
EN 61000-6-4 EN 61000-4-2 ESD EN 61000-4-8 AC MF EN 55011
EN 61000-4-3 RF EN 61000-4-9 pulse MF
group 1 class A
EN 61000-4-4 EFT EN 61000-4-11 AC dips
EN 61000-4-5 CWG EN 61000-4-12 ring wave
EN 61000-4-6 RF EN 61000-4-29 DC dips
2 t
hre
shold
s v
ers
ion w
ith
exte
rnal setp
oin
t 0..
10V
High or Low alarm Selection
ala
rm h
igh
ala
rm lo
w