an innovative solution to bio-hazardous waste management ... · hazardous substances which are a...
TRANSCRIPT
Référence[JJ/MM/AA] - Confidentiel 1
La maîtrise de l’innovation
© B
ER
TIN
TE
CH
NO
LOG
IES
/ B
T.D
46.C
/
An Innovative Solution to Bio-hazardousWaste ManagementMicrowave solution which respects the environmentSTERILWAVE 440 & 250
Référence[JJ/MM/AA] - Confidentiel 2
BIO-HAZARDOUS WASTE REGULATIONS
�Problematic:� State Governments and Federal Agencies impose laws and regulation
to manage hazardous waste. � Those specific infectious waste must be identified (colored bag) and
stored on site. Then it will be transferred by a specific carrier in order to be managed, disposed and eliminated through sub-contractors.
� Medical waste treatment is an expensive cost for Hospitals budgets.
�Regulations: � Different rules and regulations define the treatment of regulated medical
waste. (level of bacteriological inactivation, type of treatment etc…
�The STERILWAVE process exceeds all regulatory stand ards including French Regulations NF X30-503 known as on e of the strictest worldwide
Référence[JJ/MM/AA] - Confidentiel 3
CONTEXT
� Incineration of bio-medical waste is the most common option for destroying substances representing a risk to Public Health. However, incineration give out quantities of metals, dioxin and other potentially hazardous substances which are a problematic for public health and environmental regulation.
�STERILWAVE transforms onsite up to 440 L / 35 kg of bio-medical hazardous waste into standard municipal waste by 40’min cycle.
� Without effluent, the STERILWAVE system is an innovative onsite solution for a local disinfection of bio-hazardous waste. Easy-to-use, this system can be installed in only few hours.
Référence[JJ/MM/AA] - Confidentiel 4
BIO-HAZARDOUS MEDICAL WASTE MANAGEMENT
� Pay a third-party to manage your bio-hazardous waste co uld cost youmore than you think:
� Cost of Storage and risk for the Hospital staff� Cost of Transfert:
� Expensive specific carrier is requested to transfert bio-hazardouswaste from the production place (hospital , medical laboraty…) to the destruction place (incineration or landfill).
� Cost of elimination
� With STERILWAVE you can manage your waste right at your fa cilitieswith a short payback period.
� Alternative to autoclaving solution, STERILWAVE requ est onlyElectricity supply to work
� STERILWAVE appears as a cost-effective, easy-to-use a nd safesolution.
Référence[JJ/MM/AA] - Confidentiel 5
FROM HAZARDOUS TO MUNICPAL WASTE
The bio hazardous waste are transformed into munici pal waste.
No effluents, Eco-Friendly with a weight reduction up to 25% and a volume reduction up to 80%
into Municpal waste, shredded and sterilizedBio hazardous waste
Référence[JJ/MM/AA] - Confidentiel 6
STERILWAVE : A COMPLETE RANGE OF PRODUCTS TO REACH YOUR NEEDS
SW 440 : from 400 kg to 1000 kg per daySW 250 : from 100 kg to 600 kg per day
Référence[JJ/MM/AA] - Confidentiel 7
AVANTAGES OF STERILWAVE
Innovative solution to bio-hazardous waste management
� STERIWAVE :a cost-effective solution :
� Onsite automatic disinfection. STERILWAVE converts regulated medical waste into municipal solid waste.� Request only a 10 minutes operator presence per cycle � No special carrier needed to transfer final waste � Reduce the weight of waste by up to 20% and its volume by up to 80%.
� Reduce the risks
� Eliminates your need to store biomedical waste onsite until the collect.� Eliminates risks of exposure to the staff during the storage � No intermediate handling � Fully automatic process ( loading , disinfecting , transfer) in a close and compact system.
� Easy to use
� Fully automatic process� Simple “Touch screen” operation. It require an operator for 10minutes/ cycle( loading & unloading)� Low maintenance systems� No need of pressurization ( safety systems)� Only few hours to install onsite (stand alone module)
Référence[JJ/MM/AA] - Confidentiel 8
STERILWAVE SW44050 KG / HOUR
� STERIWAVE :a cost-effective solution :� Onsite automatic disinfection. STERILWAVE
converts regulated medical waste into municipal solid waste.
� Request only a 10 minutes operator presence per cycle
� Reduce the weight of waste by up to 20% and its volume by up to 80%.
� Reduce the risks� Eliminates your need to store biomedical waste
onsite until the collect.� Eliminates risks of exposure to the staff during the
storage � No intermediate handling � Fully automatic process ( loading , disinfecting ,
transfer) in a close and compact system.
� Easy to use� Fully automatic process� Simple “Touch screen” operation. It require an
operator for 10minutes/ cycle( loading & unloading)� Low maintenance systems� No need of pressurization ( safety systems)� Only few hours to install onsite (stand alone module)
Référence[JJ/MM/AA] - Confidentiel 9
STERILWAVE 440 SPECIFICATION
Specifications
Dimension ( Lx W x H) 2,75 x 1,9 x 2 meters
Weight 1600 kg
Electricity 400V/ 3-Phase
Operating data
Automatic Loader included Yes ( Optional)
Average cycle time 35 min
Volume capacity 440 L
Waste Treatment capacity 30 to 35 Kg/ cycle
Microbial Inactivation Up to 8 log10
Volume reduction Up to 80%
Weight reduction Up to 25% ( Dry and passive waste)
Consumption
Electricity 15 Kw h( average)
Water consumption No
Référence[JJ/MM/AA] - Confidentiel 10
STERILWAVE : Outline drawing – front view
Référence[JJ/MM/AA] - Confidentiel 11
STERILWAVE SW250 30 KG / HOUR
� STERILWAVE models achieve the following specifications:
� Shredding by rotative blades� Sterilization of the shredded waste by
microwave in accordance with the NFX 30-503 Norm requirements
� Efficient, Robustness� Same engine, same power, same microwave
generator than the Sterilwave 440 for a volume capacity twice smaller!
� Specifications :� Capacity: 250 liters per cycle (about 16 kg)� Cycle time: 30 to 35 ‘min� Volume reduction: 80%� Weight reduction: 25%
Référence[JJ/MM/AA] - Confidentiel 12
STERILWAVE 250 SPECIFICATION
Specifications
Dimension ( Lx W x H) 1,6 x 1,1 x 1.5 m
Floor surface recommended 3 X 3 X 2.2 m
Electricity 400V/ 3-Phase
Average cycle time 30 -35 min
Volume capacity 250 L
Waste Treatment capacity 35 kg/ hour
Microbial Inactivation Up to 8 log10
Volume reduction Up to 80%
Weight reduction up to 25% ( Dry and passive waste)
Consumption
Electricity 12 Kwh
Water consumption No
Référence[JJ/MM/AA] - Confidentiel
Dimensions de SW250 L
Frame dimension with the tap closed (Length x width x Height) 160 x 110 x 150 cm
The loading height is at 130 cm in order to make easier the loading operation
13
Référence[JJ/MM/AA] - Confidentiel 14
CYCLE DESCRIPTION
STEP 1: bags loading (manually or automatically)
STEP 2: Grinding by rotative blades up to 1500 RPM
STEP 3: Waste is exposed to a temperature up to 110°C by a HF micro-wave generator.
STEP 4: Maintaining up to 110°C during 20 min (sterilization)
STEP 5: Automatic unloading into a intended container
Référence[JJ/MM/AA] - Confidentiel 15
SYSTEM CONTROL
1. Automated process :The entire process is controlled by a PLC.
2. The Software manages the waste treatment cycle, ensuring that the temperature parameters and the safety are under control.
3. The System insures the operator safety
Référence[JJ/MM/AA] - Confidentiel 16
UNLOADING
� Unloading Phase :
� At the end of the cycle, the door is openning. The rotor pushes out the waste into a specific container
� Treated waste are unloaded automatically in another container
� The container can stay up to 2-3 cycles before being dispached
Référence[JJ/MM/AA] - Confidentiel 1717
Référence[JJ/MM/AA] - Confidentiel 18
STERILWAVE ASSETS
Effective:
Disinfect waste up to 8 log10 reduction of bacterial spores.Final waste are dry and inert and could be recycled.Reduce the volume of waste by up to 80% and weight by up to 20%.
Environmental friendly :
No liquid effluents.No Hazardous emissions. Allow onsite medical waste treatment
Référence[JJ/MM/AA] - Confidentiel 19
COMPARATIVE STUDYAUTOCLAVE INCINERATION STERILWAVE
Technology Temperature under pressure over 130 °C
Require a steam-powered generator
Incineration on specific location.
Require special carrier (expensive)
Based on microwave technology, simple and efficient (heating at 100°C)
Pressure / authorization Equipment working under pressure (several bars of saturated steam)
The operator has to be skilled and require specific autorisation to work on the machineRequire to plan many maintenance tasks
Ambient pressure
Integrated grinding syst. Yes No Yes by rotative blade: 1500 RPM
Disinfection efficiency from 5 log to 8 log10 (depending the brand model)
Complete destruction Over 8 log10
Waste aspect after treatment
-Volume reduction up to 80%
-Wet waste
-Weight reduction up to 20%
Complete destruction Volume reduction up to 80% Dry Waste
-Weight reduction of 20%
Effluent treatment Liquid effluents NC No effluents
Environmental impact Medium�Require important volume of water (negative)
�Liquid effluents (negative)
�Possibity of onsite waste treatment (positive)
Negative�Pollution
�Special carrier always requested
�Incineration / Toxin
Positive�Onsite waste treatment
�No effluents
�Volume and weight reduction of the treated waste
�Require only electricity
Référence[JJ/MM/AA] - Confidentiel 20
MICROBIAL INACTIVATION EFFICIENCY
�Test report had been provided by validated and cert ified French Laboratries IRM and EUROFIN (Pasteur Institut)
� STERILWAVE took with succes all homolagation tests requested by the French Ministry of Health: norm NF X 30-503
� Gram+ : Staphylococcus aureus: Reduction > 8 Log� GRAM+2 :Enterococcus hirae: Reduction > 8 Log� Gram- :Pseudomonas aeruginosa: Reduction > 8 Log� Gram- Escherichia coli: Reduction > 8 log � Spore: Bacillus atropheus: Reduction > 8 Log� Mycobacterie : Mycobacterium smegmatis: Reduction > 8 log� Lévures : Candida albicans: Reduction > 8 log� Champignon Aspergillus niger: Reduction > 8 log� Virus Enterovirus polio: Reduction > 8 log � Protozoaires :Naegleria lovaniensis: Reduction> 5 log
Référence[JJ/MM/AA] - Confidentiel
HEAT UP Comparison between Microwave and Autoclave solutions
21
The principle of the Autoclave is to heat up with
saturated steam the chamber by rising the
pressure inside the tank. The waste are heated up
from the outside to the depths by thermic
exchange. The temperature at the depths of the
waste is rising up more slowly which request a
higher tempreature degree for the waste
disinfection (indirect heat up)
The microwaves are heating up the waste at its
Depths , then heat up from the center to the
outside of the waste. The result is an
optimization of the waste disinfection. The very
thin shredding improve the disinfection efficiency
MICROWAVE / STERILWAVE AUTOCLAVE
Référence[JJ/MM/AA] - Confidentiel
Temperature chart: Heating Up at the Depths of the ProductMicrowave Technology VS Autoclave
22
This chart is describing the temperature at the depths of the product (the waste actually) and not the temperature of the chamber (temperature sensors)The temperature at the depths of the product is heating up quickest with microwave than with saturated steam. The efficiency of disinfection of the STERILWAVE device (8log) is over than most part of Autoclave solutions (6log)
Référence[JJ/MM/AA] - Confidentiel
Adaptation of the microwave with metal wastes
Insulator description
� Static mechanical component which is not running with electricity.
� Composed of 3 similar guideline for the microwave transfer. The insulator is dimensioned for this magnetron frequency: 2450 MHz
� Installed between the Magnetron and the chamber where are disposed the waste.
Role of the Insulator
� Insulating and protecting the magnetron of any reflected power due to the reflection of microwave on metal parts.
� The insulator insure:1. The transfer of the power between the magnetron (way
N°1) and the chamber (way N°2)2. the complete deviation of any reflected wave from the
chamber (way N°2) to the evacuation way N°3 (cooling system to evacuate the power).
23