Technical Specifications
Working Voltage : 40 – 265 V ACBackup : UltraCapMemory Unit : 2MB FlashWorking Temperature : -25°C +70°CTamper Detection : Connection Cover Open AlertRemote Firmware Update : Crypto protected
Downward Interface Units
RS 232/RS485 : IEC 62056-21MBUS : IEC 13757RF : IEC13757-4 wL MBUSPLC : CENELEC A
• GPRS• Quadband
• Compatible with all GSM operators• SIM Cards can be installed or changed on site
BASIC ELEMENTS OF AMR/AMI
1. Smart Meters
Meters which periodically stores consumption values and send to the distribution company for billing and control purposes with theircommunication systems. 2. Communication Unit
Communication Units communicate with the smart meters connected themselves according to periodical or instant reading demands and collects data from meters, store data and then send to the data control center. The unit is a bridge between smart meters and control center. If somehow there becomes a communication problem between control unit and data center, control unit stores the data from short term till next succesfull communication.
AMR
Automatic Meter Reading
AMR is a technology that periodically (daily, hourly…) communicates with smart meters, collects consumption and meter state information with one way data communication and then transfers the data to control center for storage, billing, analisys and investment planning purposes.
Electronics, digital hardware and software work simultaneously and provide continues periodical meter reading with all timeavailable remote communication.Provides detailed information collection ability.
AMI
Advanced Metering Infrastructure
AMR goes beyond AMR system and provides remote control usage for fixed meter networks with two way data communication.
Meters in the AMI system are smart meters which can use collected data with programmed logic.
1
ww
w.e
lekt
rom
ed
.co
m.tr
SMARTMETERS
COMMUNICATIONUNIT
CONTROLCENTER
CONTROLCENTER
SMARTMETERS
COMMUNICATIONUNIT
3. Control Center
Control Center stores the data collected from smart meters through Communication Units (CU) to the database. It converts these data to usable and meaningful data andgraphics for use of authorised users analisys and planning.
2
ww
w.e
lekt
rom
ed
.co
m.tr
• Subscriber Management System Menu • AMR Menu• Periodical Reading• Consumption Graphics • Work Orders• Sending SMS • Sending E-mail• Excel Output Ability• Pdf Output Ability• Communication Unit Operations
Main Menu-
+ Subscription Operations
Meter Operations
Payment Operations
Sales Operations
Collection Operations
Cashpoint Reports
Reporting Operations
Setup
System
AMR
Communication Unit Group Operations
Communication Unit Operations
Services
Meter Consuption
Periodical Reading
Periodical Reading Error Analisys
Meter Grouping Operations
Reports
AMR Projects
AMR Log
Load Profile
Work Oders
+
+
+
+
+
+
+
+
+
+
+
+
-
Create a job order
Concluding the work order
Benefits of AMR/AMI
1. Efficient Use of Natural Resources
• Consumption of residential meters that are connected to the main line compared with the amount ofdistribution losses and leakages are detected immediately.• Line losses are reduced by the rapid detection of failures.• Line loses are reduced by following consumption habits and instant tariffications.• Inefficient lines are detected and renewed.• Providing web software to track customer's consumption over the investments made by analyzing the amount of annual consumption.
2. Decreased Loss-Leakage Rates
• Detection of unauthorized interventions• Detection of network based losses• Reporting of low consumption subscribers• Detection of sudden consumption drops ( by-passing of the meter )• Deterrent against the illegal use of power increase with immediate detection of leaks • Instant follow-up of unpaid bills
3. Cost Decrease
• Low first ınvestment cost• Low operating costs• Reading hourly consumption data by once in a month connection• Decrease in unit costs by reducing losses and leakages• Fast, easy and secure data reading• No need for meter reading staff • No need for meter open-close staff • Saving for all the years of system operating
3
ww
w.e
lekt
rom
ed
.co
m.tr
5. Efficient Accrual System
• Short billling process• Instant remove shut-down for non-paying customers• Definite solution for collection problems with ABYS software integrated prepayment module• Cash increase by decreasing of loss and leakage with reporting and analysis• Customer satisfaction leads to the increase in the number of customers
4
ww
w.e
lekt
rom
ed
.co
m.tr
4. Increased Data Security
• Increased AMR data collection performance• Protection against wrong data reading and loss of collected data• Increased data security for data transmision between AMR system and other applicaitons • Removing of potential error source because there is no manual data entry
6. Increased Customer Services Quality
• Fast and accurate billing• Lowered costs leads to lower unit prices• Fast meter turn on process• Fast intervention to line malfunctions and uninterrepted service• Customer may watch self consumption from the web software customer account
Customer Service
Excellent
Poor
5
ww
w.e
lekt
rom
ed
.co
m.tr
Walk - by : Reading Meter by Hand Held TerminalDrive - by : Reading Meter by RF-Van mobile vehicleFixed - base : Meter reading by one way RF transmission using RF Fixed-base Communication Units 2Way RF : A technology which enables to read meter data remotely using radio reciever/transmitter on the meters and perform open/close process by means of valves and relays in the meters.
Wireless MBUS protocol and RF modules are used in ELEKTROMED system solutions.
50
ControlCenter
Fixed-base
50
RF VAN
Drive-by
ControlCenter
50
Walk-by
ControlCenter
AMR / AMI SOLUTIONS - RF
6
ww
w.e
lekt
rom
ed
.co
m.tr
Drive-by
PLCNETWORK
RF
RF VAN
AMR / AMI SOLUTIONS
7
ww
w.e
lekt
rom
ed
.co
m.tr
ControlCenter
PSTN
GPRS
Internet
Base Station
Electricity
Walk-by
Fixed-base
RF
RF
8
ww
w.e
lekt
rom
ed
.co
m.tr
PLC is a communication technology over power lines for reading meter data remotely and open close meter relays. No extra cableing or RF structure is needed because the transmission is done over power lines. Communication structure enables 1024 meters over same line.
PLC uses existing power network system for data transfer. One connection may be used by more then one users. This way users connected to the same power network may read data over one cable.
PLC modems used in the system are working at CENELEC A-Band used in Europe for observation, control and energy usage.
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
split PLC
PLC Network
Und
ergr
ound
Lin
e
Aerial Line
Substation
AMR / AMI SOLUTIONS - PLC
9
ww
w.e
lekt
rom
ed
.co
m.tr
During the MBUS Read System Design, following criterias are taken into consideration as advantages over competitors.
1- With international standard meter reading interface, ability to modelling and reading all segment (electricity, water, gas, heat meters) meter datas2- Ability to read high number of meters remotely3- Low energy consumption4- High data transfer speed ( 300-115200 baudrate)5- Data security ( DES, AES128)6- Easy connection-installation (polarity difference) 7- Standardization for wireless and wired applications
MBUS developed internationally accepted standards for long distance, secure meter reading, monitoring and control systems of high number of meters.
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
OSOS OSOS OSOSOSOS OSOS OSOSOSOS OSOSOSOS
WATERTANK
USB
AMR / AMI SOLUTIONS - MBUS
10
ww
w.e
lekt
rom
ed
.co
m.tr
RS485 : A communication technology which allows multiple numbered meters ( up to 128) connection to the same line and used to read meter data and control the meters. Communication distance may increase up to 1000 meters.
PSTN ( Public Switched Telephone Network ) : A communication technology used to trasmit meter data over fixed phone lines.
ETHERNET : A communication technology used to read meter data and control meters remotely by LAN / DSL connection over local network or internet.
IndustrialAMR
ResidentialAMR
AMR / AMI SOLUTIONS - RS485 AMR
Data Verification
Data verification by comparing sum of consumption data saved to the database and load profile received from the meter
Reporting and Work Orders
Instant service work order formation
Meter Consumption Graphics
The Last 24 hours, The Last One Week, The Last One Month and Between Two Dates Consumption Graphics
Other Properties
Data Reading Detail Monitoring Service Operations
Open Close Unit Control Meter Tariff Configuration Meter Read Period Configuration Communication Unit Period Configuration
Work Orders
Automatic Work Order Configuration Manual Work Order Formation Work Order Assigning and Resulting
Reporting
OSF07.02 Report Format Excel Output Difference Consumption Report Reactive Penalty Report Data Verification Reporting (Load Profile Comparison Data Verification - Monthly, Last Month Comparison, Last Year Comparison )
12
ww
w.e
lekt
rom
ed
.co
m.tr
WEB SOFTWARE
Periodical Meter Reading
11
ww
w.e
lekt
rom
ed
.co
m.tr
Communication Unit Operations
Communication Unit Brand ListCommunication Technology Options (RF, RS485, MBUS…)Communication Mode ( Server, Client )Penalty StatusEnergy Status