UPFLOW/HORIZONTALTWO-STAGE, VARIABLE SPEED
GAS-FIRED FURNACE
PUB. NO. 12-1095-06
FREEDOM 80VSMODELS AUD060,080,100,120,140R9V
© 2009 American Standard Heating & Air Conditioning
PRODUCT DATAAmerican Standard Heating & Air Conditioning
2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
FREEDOM 80VS STANDARD EQUIPMENT• Common vent capability• Cleanable framed filters• Optional L.P. conversion kit• Left/right gas connection• Accessory hook-up capability• Selectable cooling fan off delay
eliminates need for BAY24X045 timedelay kit
• Enhanced cooling control
• Upflow/Horizontal andDownflow/Horizontal
• Power supply 115/1/60• 2-stage gas valve• 2-speed venter• Variable speed blower motor• Silicon Nitride hot surface igniter with
adaptive heat up• Integrated solid state control• Attractive color accents• Heavy gauge aluminized steel heat
exchanger• Multi-port In-shot burners
• Complete front service access• Alternate bottom/left/right return air• Slide out blower assembly• Hinged blower door• Perfect fit door catches• Insulated blower door• Gasketed blower door• Internal filter rack• Standard filter sizes• Two-tone color• Direct drive, variable speed motor• Integrated solid state control with
self-diagnostics
FREEDOM 80VS OPTIONAL EQUIPMENTThermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ]Thermostat, Mechanical Heating Only With Fan Switch .............................................................................................. BAYSTAT303 [ ]Thermostat, Mechanical Heating Only ........................................................................................................................ BAYSTAT388 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ]Thermostat, Electronic Non-programmable 1-Stage Heating/1-Stage Cooling ............................................................ BAYSTAT370 [ ]Thermostat, Electronic Programmable (5-2) 1-Stage Heating/1-Stage Cooling ........................................................... BAYSTAT340 [ ]Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................... BAYSTAT305 [ ]Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling ................................................................. TAYSTAT302C [ ]Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling ................................................................. TAYSTAT300C [ ]Propane Conversion Kit ............................................................................................................................................ BAYLPKT210A [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .................................................... TFP175A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ ]Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .................................................... TFP245A9FR0 [ ]Coil Enclosure (17-1/2" Wide Cabinets) ............................................................................................................ BAYCLE17A1722A [ ]Coil Enclosure (21" Wide Cabinets) .................................................................................................................. BAYCLE21A2130A [ ]Coil Enclosure (24-1/2" Wide Cabinets) ............................................................................................................ BAYCLE24A2430A [ ]Side Filter Rack .......................................................................................................................................................... BAYFLTR200 [ ]High Altitude Switch ................................................................................................................................................... BAYHALT249 [ ]Masonry Chimney Vent Kit ....................................................................................................................................... BAYVENT800B [ ]Filter Rack Kit 1 ..................................................................................................................................................... BAYRACK960A [ ]1 Available for models with 1800 CFM or greater which require an additional side return.
FEATURESAIR DELIVERY — The variable speed, direct drive blower motor,has sufficient airflow for most heating and cooling requirements,will switch from heating to cooling speeds on demand from roomthermostat. The blower door safety switch will prevent or termi-nate furnace operation when the blower door is removed.
STYLING — Heavy gauge steel and “wrap-around” cabinetconstruction is used in the cabinet with baked-on enamel finishfor strength and beauty. The heat exchanger section of the cabinetis completely lined with foil faced fiberglass insulation. This resultsin quiet and efficient operation due to the excellent acoustical andinsulating qualities of fiberglass. Built-in bottom pan and alternatebottom, left or right side return air connection provision.
FEATURES AND GENERAL OPERATION — The Freedom 80VS
High Efficiency Gas Furnaces employ a Hot Surface Ignition system,which eliminates the waste of a constant burning pilot. The inte-grated system control lights the main burners upon a demand forheat from the room thermostat. Complete front service access.
a. Low energy power venterb. Vent proving pressure switch.
NATURAL GAS MODELS — Central Heating furnace designs arecertified by the American Gas Association for both natural andL.P. gas. Limit setting and rating data were established and ap-proved under standard rating conditions using American NationalStandards Institute standards.
SAFE OPERATION — The Integrated System Control has solidstate devices, which continuously monitor for presence of flame,when the system is in the heating mode of operation. Dual sole-noid combination gas valve and regulator provide extra safety.
QUICK HEATING — Durable, cycle tested, heavy gauge alumi-nized steel heat exchanger quickly transfers heat to provide warmconditioned air to the structure. Low energy power vent blower,to increase efficiency and provide a positive discharge of gas fumesto the outside.
BURNERS — Multi-port In-shot burners will give years of quietand efficient service. All models can be converted to L.P. gas.
INTEGRATED SYSTEM CONTROL — Exclusively designed opera-tional program provides total control of furnace limit sensors, blowers,gas valve, flame control and includes self-diagnostics for ease ofservice. Also contains connection points for E.A.C./humidifier.
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 3
PRODUCT DATAAmerican Standard Heating & Air Conditioning
MODEL
TYPE
RATINGS 21st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs.)
AUD-R9V PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
GENERAL DATA
AUD080R9V3K
Upflow / Horizontal
52,00041,60080,00064,00030 - 60
Direct10 x 7
1Variable
See Airflow Table1/2
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.0
YesHigh Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel - Type 1
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/6010.515
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
142 / 132
AUD060R9V3K
Upflow / Horizontal
39,00031,20060,00048,00030 - 60
Direct10 x 7
1Variable
See Airflow Table1/2
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.0
YesHigh Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel - Type 1
20
3 — 453 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot3
115/1/6010.515
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
136 / 126
AUD080R9V4K
Upflow / Horizontal
52,00041,60080,00064,00030 - 60
Direct10 x 10
1Variable
See Airflow Table3/4
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.0
YesHigh Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel - Type 1
20
4 — 454 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot4
115/1/6012.920
1/2
H x W x D41-3/4 x 23 x 30-1/2
166 / 155
PRODUCT DATAAmerican Standard Heating & Air Conditioning
4 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
MODEL
TYPE
RATINGS 21st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 32nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3Temp. rise (Min.-Max.) °F.
BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / Hz
COMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLA
FILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)
VENT — Size (In.)
HEAT EXCHANGERType -Fired
-UnfiredGauge (Fired)
ORIFICES — MainNat. Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill Size
GAS VALVE
PILOT SAFETY DEVICEType
BURNERS — TypeNumber
POWER CONN. — V / Ph / Hz 4Ampacity (In Amps)Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (In.)
DIMENSIONSCrated (In.)
WEIGHTShipping (Lbs.) / Net (Lbs.)
AUD-R9V PRODUCT SPECIFICATIONS1
1 Central Furnace heating designs are certified by AGA and ETL.2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.3 Based on U.S. government standard tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
AUD120R9V5K
Upflow / Horizontal
78,00062,400120,00097,00035 - 65
Direct10 x 10
1Variable
See Airflow Table1
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.15
YesHigh Velocity
1 - 24x25 - 1in.
4 Round
Alum. Steel - Type 1
20
6 — 456 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot6
115/1/6015.320
1/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
193 / 181
AUD140R9V5K
Upflow / Horizontal
91,00072,800140,000111,00040 - 70
Direct10 x 10
1Variable
See Airflow Table1
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
0.95
YesHigh Velocity
1 - 24x25 - 1in.
4 Round
Alum. Steel - Type 1
20
7 — 457 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot7
115/1/6015.320
1/2
H x W x D41-3/4 x 26-1/2 x 30-1/2
197 / 185
AUD100R9V5K
Upflow / Horizontal
65,00052,000100,00079,00035 - 65
Direct10 x 10
1Variable
See Airflow Table1
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.0
YesHigh Velocity
1 - 20x25 - 1in.
4 Round
Alum. Steel - Type 1
20
5 — 455 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6014.920
1/2
H x W x D41-3/4 x 23 x 30-1/2
166 / 155
AUD100R9V3K
Upflow / Horizontal
65,00052,000100,00080,00040 - 70
Direct10 x 7
1Variable
See Airflow Table1/2
Variable115/1/60
CentrifugalDirect - 2
1/50 - 3000115/1/60
1.0
YesHigh Velocity
1 - 17x25 - 1in.
4 Round
Alum. Steel - Type 1
20
5 — 455 — 56
Redundant - Two Stage
Hot Surface Ignition
Multi-port In-shot5
115/1/6010.815
1/2
H x W x D41-3/4 x 19-1/2 x 30-1/2
142 / 132
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 5
PRODUCT DATAAmerican Standard Heating & Air Conditioning
PERFORMANCE DATA
AUD060R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/ TON) ON ON OFF ON
CFM 499 537 520 520 500WATTS 50 80 110 145 175
NORMAL(400 CFM/ TON) ON ON OFF OFF
CFM 605 610 610 597 593WATTS 60 80 120 155 180
HIGH(450 CFM/ TON) ON ON ON OFF
CFM 649 681 665 665 672WATTS 75 110 145 180 220
2
LOW(350 CFM/ TON) OFF ON OFF ON
CFM 680 722 680 696 696WATTS 80 125 150 190 225
NORMAL(400 CFM/ TON) OFF ON OFF OFF
CFM 798 804 809 823 818WATTS 105 145 170 235 280
HIGH(450 CFM/ TON) OFF ON ON OFF
CFM 884 896 924 931 931WATTS 145 180 240 280 330
2.5
LOW(350 CFM/ TON) ON OFF OFF ON
CFM 858 863 882 894 895WATTS 125 175 220 275 320
NORMAL(400 CFM/ TON) ON OFF OFF OFF
CFM 984 1017 1038 1017 1017WATTS 170 225 295 330 375
HIGH(450 CFM/ TON) ON OFF ON OFF
CFM 1125 1138 1150 1161 1161WATTS 245 315 370 435 475
3 **
LOW(350 CFM/ TON) OFF OFF OFF ON
CFM 1035 1056 1076 1076 1076WATTS 205 265 330 370 430
NORMAL **(400 CFM/ TON) OFF OFF OFF OFF
CFM 1208 1247 1268 1278 1200WATTS 300 360 440 485 490
HIGH(450 CFM/ TON) OFF OFF ON OFF
CFM 1380 1410 1402 1350 1235WATTS 440 500 550 550 525
NOTES: 1. **FACTORY SETTING. 2. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 3. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 4. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
AUD060R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW7 SW8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM 589 604 619 604 607
TEMP. RISE 49 48 47 48 48WATTS 65 95 125 160 200
MEDIUM ** ON OFFCFM 663 694 684 681 686
TEMP. RISE 44 42 42 42 42WATTS 75 120 145 185 220
HIGH OFF OFFCFM 775 781 776 805 811
TEMP. RISE 37 37 37 36 36WATTS 105 145 180 230 270
HEATING2ND
STAGE
LOW ON ONCFM 813 818 818 837 842
TEMP. RISE 55 54 54 53 53WATTS 110 150 185 240 280
MEDIUM ** ON OFFCFM 907 919 942 958 959
TEMP. RISE 49 48 47 46 46WATTS 140 200 240 300 330
HIGH OFFCFM 1038 1066 1086 1089 1079
OFF TEMP. RISE 43 42 41 41 41WATTS 190 260 325 365 415
Notes: ** Factory setting
PRODUCT DATAAmerican Standard Heating & Air Conditioning
6 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
AUD080R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS880120
875155
860190
845225
840245
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1020170
1000205
990240
980280
960320
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1110210
110260
1110320
1100350
1100385
3.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1040190
1010220
1000260
1000310
990340
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1200250
1200320
1190370
1190415
1175450
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1340355
1340425
1330475
1320530
1300570
3.5 **
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1215265
1210330
1210375
1200430
1185465
NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1430415
1415457
1410520
1385575
1330580
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1430415
1415475
1410520
1385575
1330580
NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
AUD080R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
80048100
79049135
76550155
75052
200
73053230
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
91043130
89044170
87544210
86045240
82047280
HIGH OFF OFFCFM
TEMP. RISEWATTS
106037188
102038220
101039265
101039310
100039350
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
111054210
109055260
109055310
108055350
106556400
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
124548300
124048355
124048410
123048460
121549500
HIGH OFF OFFCFM
TEMP. RISEWATTS
141542410
140042470
140042530
137543580
132045590
Notes: ** Factory setting *** Above MAX temperature change value
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 7
PRODUCT DATAAmerican Standard Heating & Air Conditioning
AUD080R9V4K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
2.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS86390
865130
858175
843220
831255
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS995115
1005170
989210
973260
956305
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1101150
1112200
1111255
1107305
1101360
3.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1031125
1031175
1026215
1013270
1003320
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1163170
1178230
1188285
1183345
1178405
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS1319240
1337305
1344365
1340420
1336485
3.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1182200
1206240
1211295
1211350
1211420
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1380255
1401325
1402390
1402460
1399515
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1553350
1566425
1557500
1558560
1559645
4 **
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1386255
1401330
1408395
1402460
1390520
NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1590360
1593440
1591515
1588575
1576650
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1791360
1808615
1810615
1808775
1726800
NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
AUD080R9V4K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
7824975
76251
110
75151
145
74851
185
73752225
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
8704490
86545125
86145175
84845215
83146255
HIGH OFF OFFCFM
TEMP. RISEWATTS
96240110
97440155
96340200
93841
245
91442290
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
109154145
109254190
108755245
109254305
107755355
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
121149190
124348255
124348310
124448370
123548430
HIGH OFF OFFCFM
TEMP. RISEWATTS
137143255
138843325
139243395
138543455
137743515
Notes: ** Factory setting
PRODUCT DATAAmerican Standard Heating & Air Conditioning
8 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
AUD100R9V3K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
1.5
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS51650
53675
551105
547135
530165
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS58359
61592
633127
621157
618185
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS68170
697110
701140
709180
712215
2.0
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS68075
726120
735150
741190
745230
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS769103
819145
843190
858235
865286
HIGH(450 CFM/TON) OFF ON ON OFF CFM
WATTS882130
938190
961245
975300
970345
2.5
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS831180
903180
928230
935275
935320
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS979167
1036240
1053295
1053345
1015368
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1121245
1147310
1176383
1167442
1055396
3.0**
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1061210
1081265
1095320
1101382
1032380
NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1185278
1223364
1251435
1205455
1101426
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS1351425
1372503
1343535
1248505
1168480
NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
AUD100R9V3K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
7516486
79661
132
81759175
83258218
83857263
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
86256121
92152185
95351
233
96750285
95450322
HIGH OFF OFFCFM
TEMP. RISEWATTS
95950148
100248210
103646280
103646325
100348355
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
109967227
112466287
114964355
115764415
105570395
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
128658365
132156450
131356455
121561
475
111966450
HIGH OFF OFFCFM
TEMP. RISEWATTS
139953465
141952570
134755545
126559520
116364485
Notes: ** Factory setting
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 9
PRODUCT DATAAmerican Standard Heating & Air Conditioning
AUD100R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
90053100
89054130
87055175
85057220
83558270
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
112543150
109044200
106046235
107045300
107045340
HIGH OFF OFFCFM
TEMP. RISEWATTS
130037220
130037290
132036365
135036430
134036490
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
127059200
129058260
129058335
129058400
128058460
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
157547355
160046445
161046520
160046575
158047650
HIGH OFF OFFCFM
TEMP. RISEWATTS
187040560
189039665
186040710
187040830
173043760
Notes: ** Factory setting
AUD100R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.0
LOW(350 CFM/TON) ON ON OFF ON CFM
WATTS1075135
1055185
1015220
1000265
990325
NORMAL(400 CFM/TON) ON ON OFF OFF CFM
WATTS1220185
1200240
1210295
1210350
1210410
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1390245
1390320
1410391
1410470
1400510
3.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1214185
1210240
1215295
1210350
1210415
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1430310
1460355
1470430
1460500
1440555
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1640370
1665460
1650540
1640615
1610660
4.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1405270
1430310
1440375
1440480
1420550
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1670395
1675490
1670550
1655630
1630700
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1870540
1880635
1880730
1845800
1670640
5.0 **
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1775480
1800580
1820680
1800750
1680740
NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS2065755
2020840
1945900
1805880
1623800
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS23101000
21001000
2100950
1965890
1800825
NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
PRODUCT DATAAmerican Standard Heating & Air Conditioning
10 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
AUD120R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW7 SW8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM 1007 1062 1084 1063 1063
TEMP. RISE 57 54 53 54 54WATTS 114 177 285 303 350
MEDIUM ** ON OFFCFM 1154 1211 1211 1221 1212
TEMP. RISE 50 48 48 47 48WATTS 167 230 277 344 417
HIGH OFF OFFCFM 1288 1319 1310 1349 1358
TEMP. RISE 45 44 44 43 43WATTS 208 273 330 410 460
HEATING2ND
STAGE
LOW ON ONCFM 1387 1421 1455 1488 1495
TEMP. RISE 64 63 61 60 59WATTS 250 320 400 460 540
MEDIUM ** ON OFFCFM 1589 1637 1666 1678 1541
TEMP. RISE 56 54 53 53 58WATTS 350 440 535 600 575
HIGH OFF OFFCFM 1771 1788 1804 1751 1554
TEMP. RISE 50 50 49 51 57WATTS 475 560 650 675 590
Notes: ** Factory setting
AUD120R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
(See Notes)
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW1 SW2 SW3 SW4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON) OFF ON OFF ON
CFM 1195 1243 1235 1251 1251WATTS 150 225 275 325 410
NORMAL(400 CFM/TON) OFF ON OFF OFF
CFM 1353 1403 1417 1437 1458WATTS 210 290 370 425 485
HIGH(450 CFM/TON) OFF ON ON OFF
CFM 1554 1572 1615 1634 1567WATTS 315 410 480 570 575
4
LOW(350 CFM/TON) ON OFF OFF ON
CFM 1356 1391 1399 1433 1454WATTS 200 280 370 420 510
NORMAL(400 CFM/TON) ON OFF OFF OFF
CFM 1565 1584 1633 1639 1554WATTS 320 410 475 560 575
HIGH(450 CFM/TON) ON OFF ON OFF
CFM 1766 1799 1810 1784 1590WATTS 450 550 650 685 600
5 **
LOW(350 CFM/TON) OFF OFF OFF ON
CFM 1708 1758 1759 1775 1575WATTS 420 530 585 675 585
NORMAL **(400 CFM/TON) OFF OFF OFF OFF
CFM 1994 2018 1971 1814 1618WATTS 665 775 785 725 625
HIGH(450 CFM/TON) OFF OFF ON OFF
CFM 2247 2152 2019 1861 1693WATTS 975 925 860 765 680
NOTES: 1. **FACTORY SETTING. 2. "CONTINUOUS FAN SETTING" IS THERMOSTAT FAN SWITCH "ON" AND DIP SWITCHS 5 AND 6 "ON". 3. CONTINUOUS FAN SETTING: HEATING OR COOLING AIRFLOW IS APPROXIMATELY 50% OF SELECTED COOLING VALUE. 4. FOR VARIABLE SPEED: LOW SPEED AIRFLOWS ARE APPROXIMATELY 30% OF LISTED VALUES. 5. LOW 350 CFM/TON IS RECOMMENDED FOR VARIABLE SPEED APPLICATION FOR COMFORT & HUMID CLIMATE SETTING: NORMAL IS 400 CFM/TON: HIGH 450 CFM/TON IS FOR DRY CLIMATE SETTING.
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 11
PRODUCT DATAAmerican Standard Heating & Air Conditioning
AUD140R9V5K FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOORUNIT SIZE
(TONS)
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9
3.5
LOW(350 CFM/TON) OFF ON OFF ON CFM
WATTS1175165
1165200
1180265
1170320
1150400
NORMAL(400 CFM/TON) OFF ON OFF OFF CFM
WATTS1345225
1370285
1400360
1405440
1380490
HIGH(450 CFM/TON) ON ON ON OFF CFM
WATTS1525295
1565390
1585470
1575515
1530585
4.0
LOW(350 CFM/TON) ON OFF OFF ON CFM
WATTS1320220
1330275
1335355
1300435
1240490
NORMAL(400 CFM/TON) ON OFF OFF OFF CFM
WATTS1550310
1580400
1590475
1555540
1460610
HIGH(450 CFM/TON) ON OFF ON OFF CFM
WATTS1735430
1735510
1710600
1670675
1590710
5.0 **
LOW(350 CFM/TON) OFF OFF OFF ON CFM
WATTS1700415
1725470
1730560
1725640
1690700
NORMAL **(400 CFM/TON) OFF OFF OFF OFF CFM
WATTS1980616
1980710
1950770
1885780
1735735
HIGH(450 CFM/TON) OFF OFF ON OFF CFM
WATTS2190835
2150870
2075890
1905800
1735735
NOTES: 1. ** Factory setting 2. Continuous Fan Setting: Heating or Cooling airflow is approximately 50% of selected Cooling value. 3. For Variable Speed: low speed airflows are approximately 30% of listed values. 4. LOW 350 cfm/ton is recommended for Variable Speed application for COMFORT & HUMID CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting
AUD140R9V5K FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
AIRFLOWSETTING
DIP SWITCH SETTING EXTERNAL STATIC PRESSURE
SW 7 SW 8 0.1 0.3 0.5 0.7 0.9
HEATING1ST
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
109062130
110061
175
107063215
108062255
106063290
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
123055180
126553235
128053315
130052380
130052455
HIGH OFF OFFCFM
TEMP. RISEWATTS
138049235
140548290
142547375
143047415
145047520
HEATING2ND
STAGE
LOW ON ONCFM
TEMP. RISEWATTS
154567320
155067385
156067475
156067540
157566605
MEDIUM ** ON OFFCFM
TEMP. RISEWATTS
176059435
179058545
181058620
180058695
172560725
HIGH OFF OFFCFM
TEMP. RISEWATTS
200052615
201052715
200052790
195054820
180058775
Notes: ** Factory setting
12 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
PRODUCT DATA
SCHEMATIC DIAGRAMS FOR GAS FURNACES
AUD060,080,100,120,140R9V
LECTRICAL DATA
LEGEND
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 13
PRODUCT DATA
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY
From Dwg. 21B341127 Rev. 0
From Dwg. 21B341126 Rev. 0
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING
T
����������������O 115
��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,
����������������������������������������������������������������������������������������������������������������������������������60 HZ., PO
��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER
����������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������EA������������������������������������������������C SEE����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������
T����������������O 115 ��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,����������������������������������������������������������������������������������������������������������������������������������60 HZ., PO��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER����������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������EA������������������������������������������������C SEE����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO����������������������������������������������������������������������������������������TE 5��������������������������������������������������������������������������������������������������������
14 DATA SUBJECT TO CHANGE WITHOUT NOTICE 12-1095-06
PRODUCT DATA
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING WITH SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341125 Rev. 1
From Dwg. 21B341124 Rev. 1
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH SINGLE STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
12-1095-06 DATA SUBJECT TO CHANGE WITHOUT NOTICE 15
PRODUCT DATA
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING WITH TWO STAGE COOLING(OUTDOOR SECTION WITHOUT TRANSFORMER)
From Dwg. 21B341128 Rev. 0
T����������������O 115 ��������������������������������������������������������������������������������������������������������������������������������������������������������������������V 1 PH.,������������������������������������������������������������������������������������������������������������������������������������60 HZ., PO��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������WER������������������������������������������������������������������������������������������������������������������������SUPPL������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������Y PER����������������������������������������������������������������������������������������������������������������������������������������������������LOCAL CODES����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������HUM SEE
��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO
����������������������������������������������������������������������������������������TE 5
��������������������������������������������������������������������������������������������������������EA
������������������������������������������������C SEE
����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������NO
����������������������������������������������������������������������������������������TE 5
��������������������������������������������������������������������������������������������������������
Since the manufacturer has a policy of continuous productand product data improvement, it reserves the right tochange the design and specifications without notice.
Technical Literature - Printed in U.S.A.
American StandardHeating & Air Coditioning6200 Troup HighwayTyler, TX 75707
PRODUCT DATA
AU
D-R
9V O
UTL
INE
DR
AW
ING
(ALL
DIM
EN
SIO
NS
AR
E IN
INC
HE
S)
Fro
m D
wg.
21C
3416
99 R
ev. 3
DIMENSIONS
MO
DE
LA
BC
D
*UD
060R
9V3*
**U
D08
0R9V
3**
*UD
100R
9V3*
*17
-1/2
"9-
5/8"
16-1
/4"
16"
*UD
080R
9V4*
**U
D10
0R9V
5**
21"
13-1
/16"
19-3
/4"
19-1
/2"
*UD
120R
9V5*
**U
D14
0R9V
5**
24-1
/2"
15-5
/16"
23-1
/4"
23"
* -
Firs
t Let
ter
May
Be
"A"
or "
T"
*
* -
Suf
fix L
ette
rs M
ay B
e "K
" (0
Thr
ough
9)