thursday, may vienna open lab dr. bohr-gasse 3, 1030 vienna · filter integrity testing invitation...
Post on 08-Jun-2020
1 Views
Preview:
TRANSCRIPT
filter integrity testing
Invitation to user training on
Thursday, 5 May 2015 9 am - 5 pm
VIENNA OPEN LABDr. Bohr-Gasse 3, 1030 Vienna
Introduction:Accurate testing of filter integrity is critical to ensuring efficient, safepharmaceutical production and regulatory compliance. Effectivetraining of personnel to assure an understanding of the knowledge,skills and competencies related to integrity testing is also critical.International GMP regulations require that personnel shouldreceive training appropriate to the duties assigned to them, andcontinuing training should be given. Pall can help you meet theserequirements by providing high quality training through experiencedinstructors to assure immediate application of integrity testprinciples and techniques in your operation.
Description:The Filter integrity testing Training is an interactive course designedfor manufacturing operators and other relevant staff to assurean understanding of the integrity test from basics of filtration andintegrity testing, regulatory requirements, various types of integritytests, instruments used, troubleshooting and hands-on application.
Registration:We ask for timely registration:edit_torok@europe.pall.com
www.pall.com/services
A full dayof educationand customizedworkshops
INVIT INTEGRITE FILTRES PAYSAGE:Mise en page 1 21/10/13 19:21 Page1
Cost:630€ per attendee
TR
AIN
ING
S
CH
ED
ULE
08.45 - 09.00 Registration
09.00 - 10.00 Theory part 1Basics of filtration and separationFunction, construction and manufacture of filter elementsTechniques of integrity testing: destructive/ non-destructiveBubble Point (BP) and Forward Flow (FF) Test
10.00 - 12.00 Workshop part 1Preparation and execution of BP und FFIntroduction and operation of Palltronic®Flowstar IV instrument
12.00 - 13.00 Lunch break (service included)
13.00 - 13.30 Theory part 2Testing of hydrophobic filter: Water Intrusion Test (WIT)Sources of error and troubleshooting
13.30 - 14.30 Workshop Part 2Preparation and execution of Palltronic AquaWIT IV systemTroubleshooting for BP, FF and WIT
14.30 - 15.30 Workshop part 3Integrity testing of filter in single-use-systemsHandling, sources of error and troubleshooting
15.30 - 16.15 Theory part 3Regulatory requirements'Pre-/Post-Use’ recommendations‘Case-studies’, references, etc.
16.15 - 17.00 Summary and quiz showClosing and test certificate
Palltronic® Flowstar IV instrument
Palltronic® AquaWIT IV system
www.pall.com/services
INVIT INTEGRITE FILTRES PAYSAGE:Mise en page 1 21/10/13 19:21 Page2