PR
OD
UC
T C
AT
AL
OG
V 2
4.2
A
TEL: +86-21-50210890 50219970
FAX: +86-21-50217333
E-mail: sassin@sassin.com
Http: //www.sassin.com
No.2588 JINHAI RO D, PUDONG, SHANGHAI, CHINA 201209
SASSIN INTERNATIONAL ELECTRIC SHANGHAI CO.,LTD.
Specifications and technical date are subject to change without notice. Please contact us for any relevant information on ordering.
Modular Devices
Company Profile Corporate Culture - Value System
Better Vision
Sacred Mission
Core Value
Slogan
Exceeding customers' expectation with remarkable products and services. Being an enterprise that society respects and stafftake pride in.
Growing together with top electric enterprise in the world. Offering integrated electric solutions and services to top clients.
Confidence, Faith, Credit
Better Electric, Better Life
As a leading supplier in the low voltage electrics field, Sassin
International Electric Shanghai Co., Ltd is committed to designing
and manufacturing advanced circuit protection and intelligent
management products for residential, commercial and industrial
applications. SASSIN company was certified with ISO9001, ISO14000,
and its products were certified with KEMA, CB, VDE, SEMKO, TUV,
INMETRO etc.
The growing and dynamic company SASSIN is on its way to offer
integrated solutions to help individuals and organizations utilize
their energy more safely, reliably, efficiently and sustainably. The
innovation culture, which has already been absorbed into the blood
of every SASSIN staff, inspires us to continuously bring this world
better electrical product.
Dedicating to the core value "
SASSIN is willing to join hands with every partner to create a better
world of tomorrow. SASSIN company exports its products to more
than 120 countries and regions around the world.
.
.
.
Confidence, Faith, Credit",
Catalog Classification
V 24.1 Power Distribution Electrics
V 24.2 Modular Devices
V 24. Industry Control Electrics3 Contactors & Thermal RelaysDC Operated AC Contactors Soft StartersCapacitor Switching Contactors DOL StartersMotor Protection Circuit Breakers Inverters
V 24. Switches and Relays4
V 24. Power Sources5
V 24. Electrical Accessories6 Meters &
Automatic Voltage Stabilizers Voltage RegulatorsCompensated Voltage StabilizersPure Sine Wave Inverters Back Up UPSSwitching Power Supplies Control Transformers
Pushbutton Switches Indicators Control StationsPushbutton Switch Boxes Micro SwitchesRotary Change-over Cam Switches Limit SwitchesToggle Switches Time Relays
Miniature Circuit Breakers RCCBs RCBOs Main Switches Additional Components Time Switches Push Buttons and Indicator LampsSurge Protective Devices Distribution Boxes Mini Contactors Fuse Holders Accessories
RCD Blocks
Air Circuit Breakers Moulded Case Circuit Breakers Automatic Transfer Switches Load Break SwitchesFuse Combination Switches Low Voltage FusesFuse Disconnector Switches
Electronic Kilowatt Hour Meters Analogue Panel Meters Digital Panel Meters Current Transformers Metal Boxes Terminal BlocksPC Plug Socket Couplings Electric Bell & Buzzers
Power Capacitors
1
2
3
4
5
6
All products in these catalogs listed above are available in CD.
Catalog CD
All catalogs can be downloaded as PDF files fromSASSIN website.
Catalog PDF www.sassin.com
V 24
2
Contents
V 24.2 Modular DevicesMiniature Circuit Breakers RCCBs RCBOs Main Switches Additional Components Time Switches Push Buttons and Indicator LampsSurge Protective Devices Distribution Boxes Mini Contactors Fuse Holders Accessories
RCD Blocks
Instruction of Applications
Building
ApartmentsHotelsHospitalsOffices
Data Centers and Networks
Industry
Mining and MineralsAutomation IndustryFood and BeverageChemical Industry
Energy and Infrastructures
AirportsOil and GasWaterEnergy
Modular Devices
3SB71-63 Miniature Circuit Breakers3SB71-125 Miniature Circuit Breakers3SB71Z DC Miniature Circuit Breakers3SB66 DPN Miniature Circuit Breakers
3SB5 Miniature Circuit Breakers
3SB52 Miniature Circuit Breakers3SB1-63N Miniature Circuit Breakers3SB1-125 Miniature Circuit Breakers
3SL66 Residual Current Circuit Breakers
3SL52 Residual Current Circuit Breakers3SL71N-40 Residual Current Circuit Breakers with Overcurrent Protection3SB71LN Residual Current Circuit Breakers with Overcurrent Protection
3SB71L-50 Residual Current Circuit Breakers with Overcurrent Protection3SB71LB RCD BlocksAdditional Components for MCBs and RCDs3SB71G Main Switches
3SB1G Main SwitchesPushbuttons and Indicator Lamps
3SU1 3SU2 3SU3 Surge Protective Devices3SCH8 Mini ContactorsRT18 Fuse Holders3SVP6 Over-Voltage and Under-Voltage Protectors MS71 & Modular Sockets & 3SU213 Electric Bells3SE8,3SUL181H,3SRC18,3SHC18A Time Switches
3SD5, 3SD6, 3SD5T, 3SD8 Distribution Boxes
Terminal BoxDin Rail Devices Accessories
P 01-09P 10-12P 13-15P 16-17P 18-21P 22-26P 27-28P 29-34P 35-38P 39-40P 41-42P 43-44P 45-46P 47-48P 49-51
P 52-54
P 55-58
P 59
P 60-61P 62-64P 65-67
P 68P 69P 70
P 71-72P 73-75P 76-83P 84-88P 89-90
P 91P 92
P 93-94P 94P 95
P 96-103P 104P 105
P 106-110P 111P 112P 113
P 114-116
3SL71-100 Residual Current Circuit Breakers3SB1S-63 Shunt Release Circuit Breakers
BT8 Doorbell Transformer
3SD7N Metal Distribution Boxes
3SD22 & 3SD23 Three Phase Metal Boxes
3SB5K Mechanical Interlocking Miniature Circuit Breakers
3SU71 Surge Protective Devices
3SHT & 3SHA Distribution Boxes
TY3 Metal Distribution Boxes
3SB72LE-25 Residual Current Circuit Breakers
3SWH Enclosed Isolator
3SDR-60 Switching Power Supply
with Overcurrent Protection
3SB6 Miniature Circuit Breakers
3SL6 Residual Current Circuit Breakers
3SBG6 Main Switches
2-1www.sassin.com
Miniature Circuit Breakers 3SB71-63Series
Modular Devices
IEC60898-13-5
5-1010-20
IEC60947-248
12
Instruction of type code
Breaking capacity ( : H, NkA) F,Rated current
Tripping characteristic type: B, C, DNumber of poles: 1, 2, 3, 4
Standard code: 8 (IEC 60898), 9 (IEC60947)Series code
Functions
Overload protection Short circuit protection Isolation Controlling Used in residential building, non- residential building, industry, energy and infrastructure.
Technical specifications
Standards: IEC60898-1, IEC60947-2Approvals: CE TUV CBRated current In (A) : 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.24 Max. 250/440Rated frequency (Hz): 50/60 Rated insulation voltage (VAC): 500Number of poles: 1, 2, 3, 4Tripping characteristicCharacteristic curve B ( In) Characteristic curve C ( In)Characteristic curve D ( In)Thermal operating limit ( In): 1.13 - 1.45 Rated switching capacity Icn (kA): 10 Degree of protection: IP20, with connected conductorsElectrical life (times): 10,000Mechanical life (times): 20,000Breaking Capacity: Rated voltage
1P 230/400 10 7.5 15 7.5 2-4P 400 10 7.5 15 7.5
Fire resistance according to UL 94:V0Mounting position: AnyConductor cross-sections
2Solid and stranded (mm ): 0.75-35 2Finely stranded with end sleeve (mm ): 0.75-25
Terminal tightening torque (N •m): 2.8 Ambient temperature (℃): -25 ~ +45, max. 95 % humidityStorage temperature (℃): -40 ~ +75Altitude (meters): Max 2,000
, ,
Features:
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) The handle provides a clear indication of the contact position Adequate printing of all data on the front provides long-term identification Energy limiting class: 3 The emission of ionized gases is limited to the severest restrictions: 45 mm grid distance This MCB for household in accordance with: IEC 60898 -1, B, C and D tripping characteristics This MCB for industry in accordance with IEC 60947-2 instantaneous tripping characteristics with release B:4In, release C: 8In, release D: 12In This MCB may be extended with: A wide range of RCDs Full sets of accessories
Add-on devices
Add-on RCD Auxiliaries
References
Additional components: page 65~66 Accessories: page 114~116
B71 8 3 C 32 N
(V )ModelAcc.to IEC60898-1
Icn (kA) Ics (kA) Acc.to IEC60947-2
Icu (kA) Ics (kA)
3SB71-63H
3SB71-63N 1P 230/400 6 6 10 6 2-4P 400 6 6 10 6
2-2 www.sassin.com
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-63
Benefits
Attractive device designEasily recognizable, color-coded switching position Indication integrated in the handle.
123456789
1011
12
1 2 3 4 5 6 Breaking capacity 7 Energy level8 9
BrandTypeRated current
Tripping type Rated Voltage
ApprovalStandard
10 Electrical wiring diagram11 Lowest ambient temperature12 ON/OFF indication
Ergonomic handle for user- friendly switching
Extended with add-on RCD block 3SB71LB
MCB's and RCCB's can be connectedwith PIN type busbar both at the top and bottom terminals, with easy DIN-rail extraction
MCB's and RCCB's can be connectedwith FORK type busbar both at the top and bottom terminals, with easy DIN-rail extraction
Well matched with RCCB 3SL71
both on the left and right sides of the MCB.
Safety terminal: - easy wiring- protection degree IP20.
Pozidriv and slot screw head.Torque up to 2.8 N • m.
2-3www.sassin.com
Miniature Circuit Breakers 3SB71-63Series
Modular Devices
Selection and ordering data
2
610
2016
2532405063
66
66
66666
24
B71 82B02HB71 82B04HB71 82B06HB71 82B10HB71 82B16HB71 82B20HB71 82B25HB71 82B32HB71 82B40HB71 82B50HB71 82B63H
1925519257200102001120012200132001420015200162001720018
1927519277200552005620057200582005920060200612006220063
B71 82C02HB71 82 04HCB71 82 06HCB71 82 10HCB71 82 16HCB71 82 20HCB71 82 25HCB71 82 32HCB71 82 40HCB71 82 50HCB71 82 63HC
B71 82D02HB71 82 04HDB71 82 06HDB71 82 10HDB71 82 16HDB71 82 20HDB71 82 25HDB71 82 32HDB71 82 40HDB71 82 50HDB71 82 63HD
1929519297201002010120102201032010420105201062010720108
66
2 4
1 3
3
610
2016
2532405063
44
44
44444
24
B71 83B02HB71 83B04HB71 83B06HB71 83B10HB71 83B16HB71 83B20HB71 83B25HB71 83B32HB71 83B40HB71 83B50HB71 83B63H
1925919261200192002020021200222002320024200252002620027
1927919281200642006520066200672006820069200702007120072
B71 83C02HB71 83 04HCB71 83 06HCB71 83 10HCB71 83 16HCB71 83 20HCB71 83 25HCB71 83 32HCB71 83 40HCB71 83 50HCB71 83 63HC
B71 83D02HB71 83 04HDB71 83 06HDB71 83 10HDB71 83 16HDB71 83 20HDB71 83 25HDB71 83 32HDB71 83 40HDB71 83 50HDB71 83 63HD
1929919301201092011020111201122011320114201152011620117
44
2 4
1 3
6
5
610
2016
2532405063
33
33
33333
4
42 B71 84B02H
B71 84B04HB71 84B06HB71 84B10HB71 84B16HB71 84B20HB71 84B25HB71 84B32HB71 84B40HB71 84B50HB71 84B63H
1926719269200372003820039200402004120042200432004420045
1928719289200822008320084200852008620087200882008920090
B71 84C02HB71 84 04HCB71 84 06HCB71 84 10HCB71 84 16HCB71 84 20HCB71 84 25HCB71 84 32HCB71 84 40HCB71 84 50HCB71 84 63HC
B71 84D02HB71 84 04HDB71 84 06HDB71 84 10HDB71 84 16HDB71 84 20HDB71 84 25HDB71 84 32HDB71 84 40HDB71 84 50HDB71 84 63HD
1930719309201272012820129201302013120132201332013420135
33
2 4
1 3
6
5
8
7
In(A) Type code Order code Pack.Curve B Curve C Curve D
610
2016
2532405063
1925119253200012000220003200042000520006200072000820009
1212
1212
1212121212
Number of poles Type code Order code Type code Order codeIEC60898 10kA
24
B71 81B02HB71 81B04HB71 81B06HB71 81B10HB71 81B16HB71 81B20HB71 81B25HB71 81B32HB71 81B40HB71 81B50HB71 81B63H
1212
1927119273200462004720048200492005020051200522005320054
B71 81C02HB71 81 04HCB71 81 06HCB71 81 10HCB71 81 16HCB71 81 20HCB71 81 25HCB71 81 32HCB71 81 40HCB71 81 50HCB71 81 63HC
B71 81D02HB71 81 04HDB71 81 06HDB71 81 10HDB71 81 16HDB71 81 20HDB71 81 25HDB71 81 32HDB71 81 40HDB71 81 50HDB71 81 63HD
1929119293200912009220093200942009520096200972009820099
2
1
Rated current
1
2-4 www.sassin.com
Selection and ordering data
In(A) Type code Order code Pack.Curve B Curve C Curve D
610
2016
2532405063
1931119313201362013720138201392014020141201422014320144
1212
1212
1212121212
610
2016
2532405063
33
33
33333
Type code Order code Type code Order codeIEC60898 6kA 24
B71 81B02NB71 81B04NB71 81B06NB71 81B10NB71 81B16NB71 81B20NB71 81B25NB71 81B32NB71 81B40NB71 81B50NB71 81B63N
42 B71 84B02N
B71 84B04NB71 84B06NB71 84B10NB71 84B16NB71 84B20NB71 84B25NB71 84B32NB71 84B40NB71 84B50NB71 84B63N
1932719329201722017320174201752017620177201782017920180
1212
1933119333201812018220183201842018520186201872018820189
B71 81C02NB71 81 04NCB71 81 06NCB71 81 10NCB71 81 16NCB71 81 20NCB71 81 25NCB71 81 32NCB71 81 40NCB71 81 50NCB71 81 63NC
1934719349202172021820219202202022120222202232022420225
B71 84C02NB71 84 04NCB71 84 06NCB71 84 10NCB71 84 16NCB71 84 20NCB71 84 25NCB71 84 32NCB71 84 40NCB71 84 50NCB71 84 63NC
B71 81D02NB71 81 04NDB71 81 06NDB71 81 10NDB71 81 16NDB71 81 20NDB71 81 25NDB71 81 32NDB71 81 40NDB71 81 50NDB71 81 63ND
B71 84D02NB71 84 04NDB71 84 06NDB71 84 10NDB71 84 16NDB71 84 20NDB71 84 25NDB71 84 32NDB71 84 40NDB71 84 50NDB71 84 63ND
1935119353202262022720228202292023020231202322023320234
1936719369202622026320264202652026620267202682026920270
33
610
2016
2532405063
66
66
66666
24
B71 82B02NB71 82B04NB71 82B06NB71 82B10NB71 82B16NB71 82B20NB71 82B25NB71 82B32NB71 82B40NB71 82B50NB71 82B63N
1931519317201452014620147201482014920150201512015220153
1933519337201902019120192201932019420195201962019720198
B71 82C02NB71 82 04NCB71 82 06NCB71 82 10NCB71 82 16NCB71 82 20NCB71 82 25NCB71 82 32NCB71 82 40NCB71 82 50NCB71 82 63NC
B71 82D02NB71 82 04NDB71 82 06NDB71 82 10NDB71 82 16NDB71 82 20NDB71 82 25NDB71 82 32NDB71 82 40NDB71 82 50NDB71 82 63ND
1935519357202352023620237202382023920240202412024220243
66
2 4
1 3
2
1
610
2016
2532405063
44
44
44444
24
B71 83B02NB71 83B04NB71 83B06NB71 83B10NB71 83B16NB71 83B20NB71 83B25NB71 83B32NB71 83B40NB71 83B50NB71 83B63N
1931919321201542015520156201572015820159201602016120162
1933919341201992020020201202022020320204202052020620207
B71 83C02NB71 83 04NCB71 83 06NCB71 83 10NCB71 83 16NCB71 83 20NCB71 83 25NCB71 83 32NCB71 83 40NCB71 83 50NCB71 83 63NC
B71 83D02NB71 83 04NDB71 83 06NDB71 83 10NDB71 83 16NDB71 83 20NDB71 83 25NDB71 83 32NDB71 83 40NDB71 83 50NDB71 83 63ND
1935919361202442024520246202472024820249202502025120252
44
2 4
1 3
6
5
2 4
1 3
6
5
8
7
Rated current Number of poles
2
3
4
1
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-63
2-5www.sassin.com
Miniature Circuit Breakers 3SB71-63Series
Modular Devices
Selection and ordering data
In(A) Type code Order code Pack.Curve B Curve C Curve D
610
2016
2532405063
1937119373189801898118982189831898418985189861898718988
1212
1212
1212121212
Type code Order code Type code Order code24
B71 91B02FB71 91B04FB71 91B06FB71 91B10FB71 91B16FB71 91B20FB71 91B25FB71 91B32FB71 91B40FB71 91B50FB71 91B63F
1212
1939119393190251902619027190281902919030190311903219033
B71 91C02FB71 91 04FCB71 91 06FCB71 91 10FCB71 91 16FCB71 91 20FCB71 91 25FCB71 91 32FCB71 91 40FCB71 91 50FCB71 91 63FC
B71 91D02FB71 91 04FDB71 91 06FDB71 91 10FDB71 91 16FDB71 91 20FDB71 91 25FDB71 91 32FDB71 91 40FDB71 91 50FDB71 91 63FD
1941119413190701907119072190731907419075190761907719078
IEC60947-2 15KA
610
2016
2532405063
33
33
33333
42 B71 94B02F
B71 94B04FB71 94B06FB71 94B10FB71 94B16FB71 94B20FB71 94B25FB71 94B32FB71 94B40FB71 94B50FB71 94B63F
1938719389190161901719018190191902019021190221902319024
1940719409190611906219063190641906519066190671906819069
B71 94C02FB71 94 04FCB71 94 06FCB71 94 10FCB71 94 16FCB71 94 20FCB71 94 25FCB71 94 32FCB71 94 40FCB71 94 50FCB71 94 63FC
B71 94D02FB71 94 04FDB71 94 06FDB71 94 10FDB71 94 16FDB71 94 20FDB71 94 25FDB71 94 32FDB71 94 40FDB71 94 50FDB71 94 63FD
1942719429191061910719108191091911019111191121911319114
33
610
2016
2532405063
66
66
66666
24
B71 92B02FB71 92B04FB71 92B06FB71 92B10FB71 92B16FB71 92B20FB71 92B25FB71 92B32FB71 92B40FB71 92B50FB71 92B63F
1937519377189891899018991189921899318994189951899618997
1939519397190341903519036190371903819039190401904119042
B71 92C02FB71 92 04FCB71 92 06FCB71 92 10FCB71 92 16FCB71 92 20FCB71 92 25FCB71 92 32FCB71 92 40FCB71 92 50FCB71 92 63FC
B71 92D02FB71 92 04FDB71 92 06FDB71 92 10FDB71 92 16FDB71 92 20FDB71 92 25FDB71 92 32FDB71 92 40FDB71 92 50FDB71 92 63FD
1941519417190791908019081190821908319084190851908619087
66
610
2016
2532405063
44
44
44444
24
B71 93B02FB71 93B04FB71 93B06FB71 93B10FB71 93B16FB71 93B20FB71 93B25FB71 93B32FB71 93B40FB71 93B50FB71 93B63F
1937919381189981899919000190011900219003190041900519006
1939919401190431904419045190461904719048190491905019051
B71 93C02FB71 93 04FCB71 93 06FCB71 93 10FCB71 93 16FCB71 93 20FCB71 93 25FCB71 93 32FCB71 93 40FCB71 93 50FCB71 93 63FC
B71 93D02FB71 93 04FDB71 93 06FDB71 93 10FDB71 93 16FDB71 93 20FDB71 93 25FDB71 93 32FDB71 93 40FDB71 93 50FDB71 93 63FD
1941919421190881908919090190911909219093190941909519096
44
Rated current Number of poles
2 4
1 3
2
1
2 4
1 3
6
5
2 4
1 3
6
5
8
7
2
3
4
1
2-6 www.sassin.com
Selection and ordering data
In(A) Type code Order code Pack.Curve B Curve C Curve D
610
2016
2532405063
1943119433191151911619117191181911919120191211912219123
1212
1212
1212121212
610
2016
2532405063
33
33
33333
Type code Order code Type code Order code24
B71 91B02HB71 91B04HB71 91B06HB71 91B10HB71 91B16HB71 91B20HB71 91B25HB71 91B32HB71 91B40HB71 91B50HB71 91B63H
42 B71 94B02H
B71 94B04HB71 94B06HB71 94B10HB71 94B16HB71 94B20HB71 94B25HB71 94B32HB71 94B40HB71 94B50HB71 94B63H
1944719449191511915219153191541915519156191571915819159
1212
1945119453191601916119162191631916419165191661916719168
B71 91C02HB71 91 04HCB71 91 06HCB71 91 10HCB71 91 16HCB71 91 20HCB71 91 25HCB71 91 32HCB71 91 40HCB71 91 50HCB71 91 63HC
1946719469191961919719198191991920019201192021920319204
B71 94C02HB71 94 04HCB71 94 06HCB71 94 10HCB71 94 16HCB71 94 20HCB71 94 25HCB71 94 32HCB71 94 40HCB71 94 50HCB71 94 63HC
B71 91D02HB71 91 04HDB71 91 06HDB71 91 10HDB71 91 16HDB71 91 20HDB71 91 25HDB71 91 32HDB71 91 40HDB71 91 50HDB71 91 63HD
B71 94D02HB71 94 04HDB71 94 06HDB71 94 10HDB71 94 16HDB71 94 20HDB71 94 25HDB71 84 32HDB71 94 40HDB71 94 50HDB71 94 63HD
1947119473192051920619207192081920919210192111921219213
1948719489192411924219243192441924519246192471924819249
33
IEC60947-2 10KA
610
2016
2532405063
66
66
66666
24
B71 92B02HB71 92B04HB71 92B06HB71 92B10HB71 92B16HB71 92B20HB71 92B25HB71 92B32HB71 92B40HB71 92B50HB71 92B63H
1943519437191241912519126191271912819129191301913119132
1945519457191691917019171191721917319174191751917619177
B71 92C02HB71 92 04HCB71 92 06HCB71 92 10HCB71 92 16HCB71 92 20HCB71 92 25HCB71 92 32HCB71 92 40HCB71 92 50HCB71 92 63HC
B71 92D02HB71 92 04HDB71 92 06HDB71 92 10HDB71 92 16HDB71 92 20HDB71 92 25HDB71 92 32HDB71 92 40HDB71 92 50HDB71 92 63HD
1947519477192141921519216192171921819219192201922119222
66
610
2016
2532405063
44
44
44444
24
B71 93B02HB71 93B04HB71 93B06HB71 93B10HB71 93B16HB71 93B20HB71 93B25HB71 93B32HB71 93B40HB71 93B50HB71 93B63H
1943919441191331913419135191361913719138191391914019141
1945919461191781917919180191811918219183191841918519186
B71 93C02HB71 93 04HCB71 93 06HCB71 93 10HCB71 93 16HCB71 93 20HCB71 93 25HCB71 93 32HCB71 93 40HCB71 93 50HCB71 93 63HC
B71 93D02HB71 93 04HDB71 93 06HDB71 93 10HDB71 93 16HDB71 93 20HDB71 93 25HDB71 93 32HDB71 93 40HDB71 93 50HDB71 93 63HD
1947919481192231922419225192261922719228192291923019231
44
Rated current
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-63
2 4
1 3
2
1
2 4
1 3
6
5
2 4
1 3
6
5
8
7
2
3
4
1
www.sassin.com 2-7
Miniature Circuit Breakers 3SB71-63Series
Modular Devices
Tripping characteristic curves
Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C, D
IEC 60898-1 Standard
B C D0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
B 3 In 0.1 < t < 45s (In ≤ 32A) 0.1 < t < 90s (In > 32A) 5 In t < 0.1sC 5 In 0.1 < t < 15s (In ≤ 32A) 0.1 < t < 30s (In > 32A) 10 In t < 0.1sD 10 In 0.1 < t < 4s (In ≤ 32A) 0.1 < t < 8s (In > 32A) 20 In t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTest current
Tripping time
Control and protection of circuitshaving important transient inrushcurrents (large motors)
Usual loads such as:- lighting- socket outlets- small motors
Thermal release
The release is initiated by a bimetal strip in case of overload The standard defines the range of release for specific overload values Reference ambient temperature is 30 ℃
Test current
Tripping time
1.13 In
1.45 In
2.55 In 1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
IEC 60947-2 Standard
Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The standard leaves the calibration of magnetic release
, to manufacturer s decision. Sassin MCB series 3SB71-63 offers instantaneous tripping ranges - release B: 4In - release C: 8In - release D: 12In
Thermal release
The release is initiated by a bimetal strip in case of overload. The standard defines the range of release for two specific overload values. Reference ambient temperature is 30 ℃ for 3SB71-63
1.05 In
1.30 In
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
B C D
3 5 10
1.301.05
10.01
0.1
1
10
60120
3600
t (s)
14
Test current
Tripping time
2-8 www.sassin.com
Miniature Circuit BreakerSeries 3SB71-63
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-63
Selectivity
Rated current In (A)
Power supply side: RT16-00(fuse)
20 25 36 50 63 80 100 125 160
Is (kA)
Load side: 3SB71-63,Curve B,C
≤2346
1016202532405063
1.20.70.60.5
41.20.90.80.7
123.82.51.91.41.2
125.33.82.52.21.81.51.3
1266
4.53.22.62.22
1.7
12665
3.63
2.52.21.91.71.5
126666
5.64.64.13.83
2.62.4
12666666
5.54.54
3.53.3
12666666665
4.54.5
Load side: 3SB71-63,Curve B,C
0.19 0.019 0.3 0.4 0.5 0.5 0.5 0.63 0.8
Rated current In (A)
Power supply side: 3SM29-125
≤1016202532405063
16 20 25 32 40 50 63 80 100
0.3 0.4 0.5 0.5 0.5 0.63 0.8 0.5 0.5 0.5 0.63 0.8
0.5 0.5 0.63 0.8 0.5 0.5 0.63 0.8
3SM29-125S -125H -125R -250S -250H -250R3SM29 3SM29 3SM29 3SM29 3SM29
Power supply side: RT16 series
40 50 63 80 100 125 160
1 ~68~10
1316202532405063
40404040404040403020
1 5121212
1 8151515
1 8151515
1 5121212
1 5121212
1 5121212
Rated current In (A)
40404040404040403020
Is (kA)
Is (kA)
Is (kA)
Rated current In (A)
Power supply side: 3SM29
Load side: 3SB71-63,Curve B,C
Load side: 3SB71-63,Curve B,C
1 ~610~2032~4050~60
40404040404040403020
40404040404040403020
40403530303030303015
40403530303030303015
40403530303030303015
Back up protection
2-9www.sassin.com
Miniature Circuit Breakers 3SB71-63Series
Modular Devices
Outline and installation dimensions
1P
2P
3P
4P
18
3SB71-63 is installed on DIN rail.
unit in mm
outline and installation dimensions diagram
Temperature derating
The maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker isplaced. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.The reference temperature is 30℃
Ambient temperatureRated current (A)
2461016202532405063
2.605.207.8013.2021.1226.4033.0042.5653.2067.0083.79
2.522.047.5612.7020.4825.6032.0041.2851.2065.5081.90
2.464.927.382.5020.0025.0031.2540.0050.0063.0080.01
2.384.767.1412.0019.2024.0030.0038.7248.0060.5076.86
2.284.566.8411.5018.4023.0028.7537.1246.4058.0073.71
2.204.406.6011.1017.7622.2027.7535.5244.8056.0070.56
2.084.166.2410.6016.9621.2026.5033.9242.4053.0066.78
1.923.845.769.6015.3619.2024.0030.7238.4048.0060.48
1.863.765.649.304.888.6023.2529.7637.2046.5058.90
1.763.525.288.9014.2417.8022.2528.1635.6044.0055.44
When several simultaneously operating circuit breakers are mounted side by side in a small enclosure,the temperature rise inside the enclosure causes a reduction in current rating.you must then assign the rating (already derated if necessary according to ambient temperature) a downrating factor of 0.8.
2.004.006.0010.0016.0020.0025.0032.0040.0050.0063.00
- 3 5 - 3 0 - 2 0 - 1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃
3SB71-63
400V10000~
C63
2
1
4
3
6
5
8
7
IEC 60898-1GB 10963.1
90 923545
50.6
7836
54
72
1 ON
0 OFF
2-10 www.sassin.com
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-125
Instruction of type code
Rated current : 80, 100, 125(A)Trip : C, Dcharacteristic type
Number of poles: 1, 2, 3, 4
Technical Standard: IEC60947-2Approval: CERated current In (A): 80, 100, 125Rated voltage Un (V AC): 230/400Operational voltage (V AC) : Min:24; Max:250/440Number of poles: 1, 2, 3, 4Trip characteristic: C, DCharacteristic curve C (In): 8 Characteristic curve D (In):12
(In): ,
Electrical life (times): 4,000 Mechanical life (times): 10,000
specifications
Thermal operating limit (1.05-1.3)Degree of protection: IP20 with connected conductors
Breaking Capacity: Fire resistance according to UL 94: V0Mounting position: AnyConductor cross-sections
2Solid and stranded (mm ): 1-502Finely stranded with end sleeve (mm ): 1-35
Terminal tightening torque (N •m): 2.8 Ambient temperature (℃): -25 ~ +45, max. 95 % humidityStorage temperature (℃): -40 ~ +75Altitude Max (meters): 2,000
Features
Add-on devices
Auxiliaries:
References Additional components: page 65~66 Accessories: page 114~116
Rated current up to 125A The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) The handle provides a clear indication of the contact position Adequate printing of all data on the front provides long-term identification Energy limiting class: 3 The emission of ionized gases is limited to the severest restrictions: 45 mm grid distance This MCB for industry in accordance with IEC 60947-2 instantaneous tripping characteristic release B 4In, release C 8 In, release D 12In. This MCB may be extended with: A wide range of RCDs and RCBO Full sets of additional components Full sets of accessories
Functions
Overload protectionShort circuit protectionIsolationControllingUsed in residential building, non- residential building,industry, energy and infrastructure.
Series code
D125 3 C 080
3SB71-125
Model Rated voltage Acc.to IEC60947-2 Icu (kA) Ics (kA)
1P 230/400 10 7.5 (V )
2-4P 400 10 7.5
2-11www.sassin.com
Miniature Circuit Breakers 3SB71-125Series
Modular Devices
Selection and ordering data
In(A) Pack.Curve C Curve D
80100125
D125 1C080D125 1C100D125 1C125
161611616216163
D125 1D080D125 1D100D125 1D125
161731617416175
12
12
121
80100125
D125 2C080D125 2C100D125 2C125
161641616516166
D125 2D080D125 2D100D125 2D125
161761617716178
6
6
62
4
80100125
D125 3C080D125 3C100D125 3C125
161671616816169
D125 3D080D125 3D100D125 3D125
161791618016181
4
4
43
80100125
D125 4C080D125 4C100D125 4C125
161701617116172
D125 4D080D125 4D100D125 4D125
161821618316184
3
3
3
Type code Order code Type code Order code IEC60947-2 10kA
1
2
Rated currentNumber of poles
www.sassin.com2-12
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB71-125
Tripping curve
Outline and installation dimensions
23SB71-125 is installed on DIN rail terminal and can be connected with wire of less than 25mm
unit in mm
outline and installation dimensions diagram
3SB71-125
400V10000 0 OFF
1 ON~
C125
2
1
4
3
6
5
8
7
IEC 60947-2GB 10963.1
Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The standard leaves the calibration of magnetic release
, to manufacturer s decision. Sassin MCB series 3SB71-125 offers instantaneous tripping ranges release C: 8 In release D:12 In
Thermal release
The release is initiated by a bimetal strip in case of overload. The standard defines the range of release for two specific overload values. Reference ambient temperature is 30 ℃ for 3SB71-125
1.05 In
1.30 In
t≥2 h (In>63A)
t< 2h (In>63A)
Test current
Tripping time
1P3P3P4P
27
54
81
108
22.5
25.3
78max
35 92
94m
ax
C D
5 10
1.301.05
10.01
0.1
1
10
60120
3600
t (s)
14
www.sassin.com 2-13
DC Miniature Circuit Breakers 3SB71Z-63Series
Modular Devices
Instruction of type code
Functions
Overload protection Short circuit protection Controlling Protection for people and big length cables in TN and IT systems DC string protection: Protects the PV module from dangerous high DC back current Application in direct current circuit, like motors, auxiliary , circuits and photovoltaic. Used in industry and new energy
Technical Standard: IEC60898 -2 Approval: CE Rated current In (A): 6, 10, 16, 20, 25, 32, 40, 50, 63 Number of poles: 1, 2 Rated voltage Ue (VDC) : 1 P: 220 2P: 440 Operational voltage Ub (VDC) : Min. :12 Max. :1P: 250; 2P: 500 Rated insulation voltage (VAC) : 500 Rated frequency (Hz): 50/60 Rated impulse withstand voltage (kA): 5 Tripping characteristic: B, C Characteristic curve B (In): 4~7 Characteristic curve C (In): 7~15 Thermal operating limit (In):1.13~1.45 Rated breaking capacity:
specifications
Fire resistance according to UL 94: V0 Mounting position: Any Conductor cross-sections
2 Solid and stranded (mm ): 0.75-35 2 Finely stranded with end sleeve (mm ): 0.75-25
Terminal tightening torque (N • m): 2.8 Ambient temperature (℃): -25 ~ +45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude (meters): Max 2,000
2 Connection Capacity (mm ):1-25
Features
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) The handle provides a clear indication of the contact position Adequate printing of all data on the front provides long-term identification Energy limiting class: 3 The emission of ionized gases is limited to the severest restrictions: 45 mm grid distance This MCB for household in accordance with IEC 60898-2, B, C tripping characteristics This MCB may be extended with:
Full sets additional components Full sets of accessories
References
Additional components: page 65~66 Accessories: page 114~116
Code of DC circuit breaker
Breaking capacity code
Series code
Rated current (A): 6, 10, 16, 20, 25, 32, 40, 50, 63
Trip characteristic type: B, CNumber of Poles:1, 2
B71 Z 1 B 06 H
Model Rated voltage Acc.to IEC60898-2 Icn (kA) Ics (kA)
1P 220V DC 10 7.5 (V )
2P 400V DC 10 7.5 3SB71Z-63
2-14 www.sassin.com
DC Miniature Circuit Breakers3SB71Z-63Series
Mod
ular
Dev
ices
Add-on devices
Auxiliaries:
Selection and ordering data
In(A) Type code Order code Pack.Curve B Curve C
610
2016
2532405063
1212
1212121212
Type code Order codeB71Z 1B06H
66
66
66666
1212
1
2
IEC 60898-2 10 kA 176181761917620176211762217623176241762517626
B71Z 1B10HB71Z 1B16HB71Z 1B20HB71Z 1B25HB71Z 1B32HB71Z 1B40HB71Z 1B50HB71Z 1B63H
610
2016
2532405063
B71Z 2B06H 176271762817629176301763117632176331763417635
B71Z 2B10HB71Z 2B16HB71Z 2B20HB71Z 2B25HB71Z 2B32HB71Z 2B40HB71Z 2B50HB71Z 2B63H
B71Z 1C06H 176541765517656176571765817659176601766117662
B71Z 1C10HB71Z 1C16HB71Z 1C20HB71Z 1C25HB71Z 1C32HB71Z 1C40HB71Z 1C50HB71Z 1C63H
B71Z 2C06H 176631766417665176661766717668176691767017671
B71Z 2C10HB71Z 2C16HB71Z 2C20HB71Z 2C25HB71Z 2C32HB71Z 2C40HB71Z 2C50HB71Z 2C63H
Rated currentNumber of Poles
2-15www.sassin.com
DC Miniature Circuit Breakers 3SB71Z-63Series
Modular Devices
unit in mm
Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit.The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C
B 4 In 0.1 < t < 45s (In ≤ 32A) 0.1 < t < 90s (In > 32A) 7 In t < 0.1sC 7 In 0.1 < t < 15s (In ≤ 32A) 0.1 < t < 30s (In > 32A) 15 In t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTest Tripping
current time
Usual loads such as:- lighting- socket outlets- small motors
Thermal release
The release is initiated by a bimetal strip in case of overload. The standard defines the range of release for specific overload values. Reference ambient temperature is 30 ℃
Test Tripping
current time
1.13 In
1.45 In
2.55 In 1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
Outline and installation dimensions
36
181P
2P
45 35 90 92
50.6
78
2-16 www.sassin.com
Mod
ular
Dev
ices
Features
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON/OFF) The handle provides a clear indication of the contact position Adequate printing of all data on the front provides long-term
identification Energy limiting class:3 The emission of ionized gases is limited to the severest restrictions:45 mm grid distance This MCB for household in accordance with: IEC 60898 -1, B, C C tripping characteristics Full sets of accessories
Instruction of type code
Functions
Overload protection Short circuit protection Isolation both for phase and neutral line Controlling Used for the protection of plants with switched neutral Used in residential building
Technical specifications
In(A) Pack.Curve B Curve C
1P+N
6 B66 B06N 21284 B66 C06N 21291 1210 B66 B10N 21285 B66 C10N 21292 1216 B66 B16N 21286 B66 C16N 21293 1220 B66 B20N 21287 B66 C20N 21294 1225 B66 B25N 21288 B66 C25N 21295 1232 B66 B32N 21289 B66 C32N 21296 1240 B66 B40N 21290 B66 C40N 21297 12
Type code Order code
Selection and ordering data
N
N
Standard: Approval: CE
Rated voltage Un :230Rated frequency :50/60Operational voltage
pole: 1+N (1 mod)Tripping characteristic: B CCharacteristic curve B (In): 3-5Characteristic curve C (In): 5-10Thermal operating limit (In):1.13-1.45Rated switching capacity Icn (kA): 6 Degree of protection: IP20, with connected conductorsElectrical life(times): 4,000Mechanical life (times): 10,000Breaking Capacity:Model Rated voltage(V ) Icn (kA) Ics (kA) Standard3SB66 1P+N : 230 6 6 IEC60898-1Fire resistance according to UL 94:V0Mounting position: AnyConductor cross-sections
2Solid and stranded (mm ): 0.75-16 2Finely stranded with end sleeve (mm ): 0.75-16
Terminal tightening torque (N • m): 2.0 Ambient temperature (℃): -25 ~ +45, max. 95 % humidityStorage temperature (℃): -40 ~ +75 Altitude (meters): Max 2,000
2 Connection Capacity (mm ):1-16
IEC60898 -1
Rated current In (A): 6, 10, 16, 20, 25, 32, 40(VAC)
(Hz)Min/Max (VAC): 24/250
Number of ,
Reference Accessories: page 114~116
Number of poles
Rated currentType code Order code
B66 B 06 N
Rated breaking capacity N (kA) : 6Rated current (A): 6, 10, 20, 25, 32, 40
Tripping characteristic type: B, CSeries code
DPN Miniature Circuit BreakersSeries 3SB66
2-17www.sassin.com
Modular Devices
DPN Miniature Circuit Breakers Series 3SB66
Outline and installation dimensions
018 -0.4
35
78max
50.6±0.3
45±0.3
92m
ax
90m
ax
90m
ax
3SB66A
230V~
N
N
CE IEC60898
N
N
unit in mm
Tripping characteristic curves Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C
B 3 In 0.1 < t < 45s (In ≤ 32A) 0.1 < t < 90s (In > 32A) 5 In t < 0.1sC 5 In 0.1 < t < 15s (In ≤ 32A) 0.1 < t < 30s (In > 32A) 10 In t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTest current
Tripping time
Usual loads such as:- lighting- socket outlets- small motors
Thermal release
The release is initiated by a bimetal strip in case of overload. The standard defines the range of release for specific overload values. Reference ambient temperature is 30 ℃
Test current
Tripping time
1.13 In
1.45 In
2.55 IN 1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
Curve B
Curve C
2-18 www.sassin.com
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB6
Functions
Technical specifications
Instruction of type code
Breaking capacity ( : H, NkA) F,
Rated current
Tripping characteristic type: B, C, D
Number of poles(P) 1, 2, 3, 4:
Series code
B6 1 C 06 N
Standards: IEC60898-1Approvals: CE TUV CBRated current In (A): 6, 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 1P: 230/400; 2-4P: 400Operational voltage (VAC): Min. 24 Max. 250/440Rated frequency (Hz): 50/60Rated insulation voltage (VAC):Phase to ground: 250Phase to phase: 500Number of poles(P): 1, 2, 3, 4Tripping characteristic:Characteristic curve B ( In): 3-5Characteristic curve C ( In): 5-10Characteristic curve D ( In): 10-20Thermal operating limit ( In): 1.13 - 1.45Degree of protection: IP20, with connected conductorsElectrical endurance (Cycles): 4,000Mechanical endurance (Cycles): 10,000Breaking Capacity: 6kAFire resistance according to IEC 60695: 960Busbar connection: Pin typeMounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 1-35Finely stranded with end sleeve (mm²): 1-16Terminal tightening torque (N • m): 2.5Ambient temperature (℃): -5 ~ +40, max. 95 % humidityAltitude (meters): Max 2,000
℃
Overload protectionShort circuit protectionIsolationControllingUsed in residential building, non- residential building, industry, energy and infrastructure.
Features
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON/OFF)Adequate printing of all data on the front provides long-term identificationEnergy limiting class: 3The emission of ionized gases is limited to the severest restrictions: 45 mm grid distanceThis MCB for household in accordance with: IEC 60898-1, B, C and D tripping characteristics
www.sassin.com
Miniature Circuit Breakers3SB6Series
Modular Devices
2-19
2
2 4
1 3
3
2 4
1 3
6
5
4
2 4
1 3
6
5
8
7
Type code Order code Pack.Curve B Curve C Curve D
121212121212121212
Number of poles Type code Order code Type code Order codeIEC60898-1 6kA
B6 1D06NB6 1D10NB6 1D16NB6 1D20NB6 1D25NB6 1D32NB6 1D40NB6 1D50NB6 1D63N
B6 2D06NB6 2D10NB6 2D16NB6 2D20NB6 2D25NB6 2D32NB6 2D40NB6 2D50NB6 2D63N
B6 3D06NB6 3D10NB6 3D16NB6 3D20NB6 3D25NB6 3D32NB6 3D40NB6 3D50NB6 3D63N
B6 4D06NB6 4D10NB6 4D16NB6 4D20NB6 4D25NB6 4D32NB6 4D40NB6 4D50NB6 4D63N
298852988629887298882988929890298912989229893
2
1
Rated currentIn(A)
1
61016202532405063
Selection and ordering data
B6 1B06NB6 1B10NB6 1B16NB6 1B20NB6 1B25NB6 1B32NB6 1B40NB6 1B50NB6 1B63N
B6 1C06NB6 1C10NB6 1C16NB6 1C20NB6 1C25NB6 1C32NB6 1C40NB6 1C50NB6 1C63N
666666666
444444444
333333333
61016202532405063
61016202532405063
61016202532405063
B6 2B06NB6 2B10NB6 2B16NB6 2B20NB6 2B25NB6 2B32NB6 2B40NB6 2B50NB6 2B63N
B6 2C06NB6 2C10NB6 2C16NB6 2C20NB6 2C25NB6 2C32NB6 2C40NB6 2C50NB6 2C63N
B6 3C06NB6 3C10NB6 3C16NB6 3C20NB6 3C25NB6 3C32NB6 3C40NB6 3C50NB6 3C63N
B6 3B06NB6 3B10NB6 3B16NB6 3B20NB6 3B25NB6 3B32NB6 3B40NB6 3B50NB6 3B63N
B6 4B06NB6 4B10NB6 4B16NB6 4B20NB6 4B25NB6 4B32NB6 4B40NB6 4B50NB6 4B63N
B6 4C06NB6 4C10NB6 4C16NB6 4C20NB6 4C25NB6 4C32NB6 4C40NB6 4C50NB6 4C63N
100031000410005100061000710008100091001010011
298592986029861298622986329864298652986629867
298722987329874298752987629877298782987929880
298982989929900299012990229903299042990529906
299112991229913299142991529916299172991829919
299242992529926299272992829929299302993129932
299372993829939299402994129942299432994429945
299502995129952299532995429955299562995729958
299632996429965299662996729968299692997029971
299762997729978299792998029981299822998329984
299892999029991299922999329994299952999629997
2-20 www.sassin.com
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB6
Magnetic release
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C, D
B 3 In 0.1 < t < 45s (In ≤ 32A) 0.1 < t < 90s (In > 32A) 5 In t < 0.1sC 5 In 0.1 < t < 15s (In ≤ 32A) 0.1 < t < 30s (In > 32A) 10 In t < 0.1sD 10 In 0.1 < t < 4s (In ≤ 32A) 0.1 < t < 8s (In > 32A) 20 In t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTest current
Tripping time
Control and protection of circuitshaving important transient inrushcurrents (large motors)
Usual loads such as:- lighting- socket outlets- small motors
Thermal release
The release is initiated by a bimetal strip in case of overload The standard defines the range of release for specific overload values Reference ambient temperature is 30 ℃
Test current
Tripping time
1.13 In
1.45 In
2.55 In 1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
IEC 60898-1 Standard
B C D0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
Tripping characteristic curves
www.sassin.com
Miniature Circuit Breakers3SB6Series
Modular Devices
2-21
1P
2P
3P
4P
18
3SB6 is installed on DIN rail.
unit in mm
outline and installation dimensions diagram
Temperature derating
The maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker isplaced. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.The reference temperature is 30℃
When several simultaneously operating circuit breakers are mounted side by side in a small enclosure,the temperature rise inside the enclosure causes a reduction in current rating.you must then assign the rating (already derated if necessary according to ambient temperature) a downrating factor of 0.8.
843545
50
77max36
54
72
1 6
10~32
40~60
~
Temperature compensation coefficient under various operational temperature
1.20
1.18
1.16
1.14
1.12
1.12
1.09
1.08
1.07
1.05
1.04
1.03
1.00
1.00
1.00
0.96
0.96
0.97
0.80
0.92
0.87
0.75
0.88
0.83
0.70
0.84
0.80
Rated current In (A)-10 0 10 20 30 40 50 55 60℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃
Outline and installation dimensions
Model Rated Voltage Acc.to IEC60898-1 Icn (kA) Ics (kA)
1P 230/400 6-63 3 3 (V )
2-4P 400 6-63 3 33SB5T
3SB5D 50-63 4.5 4.5 6-40 6 6
50-63 4.5 4.5 6-40 6 6
Rated Current(A)
1P
2-4P 400
230/400
2-22 www.sassin.com
Mod
ular
Dev
ices
Functions
Overload protectionShort circuit protectionIsolationControllingUsed in residential building, non-residential building, energy sources, industry and infrastructure.
Technical specifications
Standard: IEC 60898-1Approvals: CE, TUV, CBRated current In (A): 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.: 24Max.: 250/440Rated insulation voltage (VAC): 500Number of poles: 1, 2, 3, 4Tripping characteristics: B, C, DCharacteristic curve B (In): 3-5 Characteristic curve C (In): 5-10Characteristic curve D (In): 10-20 Thermal operating limit (In): 1.13 - 1.45Rated switching capacity Icn (KA): 6 Degree of protection: IP20, with connected conductorsElectrical life (times): 4,000Mechanical life (times): 10,000Breaking Capacity:
Mounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35 Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque ( ): 2.5Ambient temperature (℃): -25~+45, max. 95 % humidityStorage temperature (℃): -40~+75Altitude Max.(meters): 2,000
N • m
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes(ON/OFF)The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationThis MCB for household in accordance with: IEC 60898-1, B, C and D tripping characteristicsThis MCB may be extended with: A wide range of RCDsFull sets of Full sets of accessories
additional components
Features
Add-on devices
Instruction of type code
Auxiliaries:
References
Additional components: page 67Accessories: page 114~116
Rated current (A): 20, 25, 32, 40, 50, 63
1, 2, 3, 4, 6, 10, 16,
Tripping characteristic type: B, C, D
Number of poles: 1, 2, 3, 4
B5 3 C 32 T
Series code
Breaking capacity code
Miniature Circuit BreakersSeries 3SB5
2-23www.sassin.com
Modular Devices
Miniature Circuit BreakersSeries 3SB5
Benefits
Attractive device designEasily recognizable, color-coded switching position indication integrated in the handle.
Ergonomic handle for user- friendly switching
Safety terminal: easy wiringprotection degree IP20.
MCB's and RCCB's can be connectedwith PIN type busbar both at the topand bottom terminals, with easy DIN-rail extraction.
Auxiliary contacts can be added on the left hand side of the MCB
123456789
10
11
1 2 3 4 6 7 Breaking capacity 8 9
BrandTypeRated current
Tripping typeRated Voltage
StandardApproval
10 Electrical wiring diagram 11 ON/OFF indication
Well matched with RCCB 3SL52
Square terminal version for joint accommodation of pin busbars with cables
5,
Groove designed on both sides to lower temperature rise
www.sassin.com
Miniature Circuit BreakersSeries 3SB5
2-24
Mod
ular
Dev
ices
In(A) Pack.Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
Selection and ordering data
IEC60898-1 3kA12346
1016202532405063
12121212121212121212121212
12346
1016202532405063
12346
1016202532405063
1
2
3
4
12346
1016202532405063
6
6
4
4
3
3
18603 18604 18605 18606 18607 18608 18609 18610 18611 18612 18613 18614 18615
B5 2B01TB5 2B02TB5 2B03TB5 2B04TB5 2B06TB5 2B10TB5 2B16TB5 2B20TB5 2B25TB5 2B32TB5 2B40TB5 2B50TB5 2B63T
B5 1B01TB5 1B02TB5 1B03TB5 1B04TB5 1B06TB5 1B10TB5 1B16TB5 1B20TB5 1B25TB5 1B32TB5 1B40TB5 1B50TB5 1B63T
18590 18591 18592 18593 18594 18595 18596 18597 18598 18599 18600 18601 18602
B5 3B01TB5 3B02TB5 3B03TB5 3B04TB5 3B06TB5 3B10TB5 3B16TB5 3B20TB5 3B25TB5 3B32TB5 3B40TB5 3B50TB5 3B63T
18616 18617 18618 18619 18620 18621 18622 18623 18624 18625 18626 18627 18628
B5 4B01TB5 4B02TB5 4B03TB5 4B04TB5 4B06TB5 4B10TB5 4B16TB5 4B20TB5 4B25TB5 4B32TB5 4B40TB5 4B50TB5 4B63T
18629 18630 18631 18632 18633 18634 18635 18636 18637 18638 18639 18640 18641
B5 2C01TB5 2C02TB5 2C03TB5 2C04TB5 2C06TB5 2C10TB5 2C16TB5 2C20TB5 2C25TB5 2C32TB5 2C40TB5 2C50TB5 2C63T
18655 18656 18657 18658 18659 18660 18661 18662 18663 18664 18665 18666 18667
B5 3C01TB5 3C02TB5 3C03TB5 3C04TB5 3C06TB5 3C10TB5 3C16TB5 3C20TB5 3C25TB5 3C32TB5 3C40TB5 3C50TB5 3C63T
18668 18669 18670 18671 18672 18673 18674 18675 18676 18677 18678 18679 18680
B5 4C01TB5 4C02TB5 4C03TB5 4C04TB5 4C06TB5 4C10TB5 4C16TB5 4C20TB5 4C25TB5 4C32TB5 4C40TB5 4C50TB5 4C63T
18681 18682 18683 18684 18685 18686 18687 18688 18689 18690 18691 18692 18693
B5 1C01TB5 1C02TB5 1C03TB5 1C04TB5 1C06TB5 1C10TB5 1C16TB5 1C20TB5 1C25TB5 1C32TB5 1C40TB5 1C50TB5 1C63T
18642 18643 18644 18645 18646 18647 18648 18649 18650 18651 18652 18653 18654
B5 1D01TB5 1D02TB5 1D03TB5 1D04TB5 1D06TB5 1D10TB5 1D16TB5 1D20TB5 1D25TB5 1D32TB5 1D40TB5 1D50TB5 1D63T
18694 18695 18696 18697 18698 18699 18700 18701 18702 18703 18704 18705 18706
B5 2D01TB5 2D02TB5 2D03TB5 2D04TB5 2D06TB5 2D10TB5 2D16TB5 2D20TB5 2D25TB5 2D32TB5 2D40TB5 2D50TB5 2D63T
18707 18708 18709 18710 18711 18712 18713 18714 18715 18716 18717 18718 18719
B5 3D01TB5 3D02TB5 3D03TB5 3D04TB5 3D06TB5 3D10TB5 3D16TB5 3D20TB5 3D25TB5 3D32TB5 3D40TB5 3D50TB5 3D63T
18720 18721 18722 18723 18724 18725 18726 18727 18728 18729 18730 18731 18732
B5 4D01TB5 4D02TB5 4D03TB5 4D04TB5 4D06TB5 4D10TB5 4D16TB5 4D20TB5 4D25TB5 4D32TB5 4D40TB5 4D50TB5 4D63T
18733 18734 18735 18736 18737 18738 18739 18740 18741 18742 18743 18744 18745
1
2
Rated currentNumber of poles
In(A) Pack.Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
Selection and ordering data
IEC60898-1 4.5kA5063
1212
B5 1B50DB5 1B63D
Rated CurrentNumber of poles
15063
66
B5 2B50DB5 2B63D2
5063
44
B5 3B50DB5 3B63D3
5063
33
B5 4B50DB5 4B63D4
B5 1C50DB5 1C63DB5 2C50DB5 2C63DB5 3C50DB5 3C63DB5 4C50DB5 4C63D
B5 1D50DB5 1D63DB5 2D50DB5 2D63DB5 3D50DB5 3D63DB5 4D50DB5 4D63D
18757 18758187701877118783187841879618797
1880918810188221882318835188361884818849
1886118862188741887518887188881890018901
In(A) Pack.Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
Selection and ordering data
IEC60898-1 6kA6
101620253240
12121212121212
6101620253240
6
6101620253240
4
6101620253240
B5 1B06NB5 1B10NB5 1B16NB5 1B20NB5 1B25NB5 1B32NB5 1B40N
36547365483654936550365513655236553
36558365593656036561365623656336564
B5 2B06NB5 2B10NB5 2B16NB5 2B20NB5 2B25NB5 2B32NB5 2B40N
B5 3B06NB5 3B10NB5 3B16NB5 3B20NB5 3B25NB5 3B32NB5 3B40N
36569365703657136572365733657436575
B5 4B06NB5 4B10NB5 4B16NB5 4B20NB5 4B25NB5 4B32NB5 4B40N
36580365813658236583365843658536586
B5 1C06NB5 1C10NB5 1C16NB5 1C20NB5 1C25NB5 1C32NB5 1C40N
36591365923659336594365953659636597
B5 2C06NB5 2C10NB5 2C16NB5 2C20NB5 2C25NB5 2C32NB5 2C40N
36602366033660436605366063660736608
B5 3C06NB5 3C10NB5 3C16NB5 3C20NB5 3C25NB5 3C32NB5 3C40N
36613366143661536616366173661836619
B5 4C06NB5 4C10NB5 4C16NB5 4C20NB5 4C25NB5 4C32NB5 4C40N
36624366253662636627366283662936630
B5 1D06NB5 1D10NB5 1D16NB5 1D20NB5 1D25NB5 1D32NB5 1D40N
36635366363663736638366393664036641
B5 2D06NB5 2D10NB5 2D16NB5 2D20NB5 2D25NB5 2D32NB5 2D40N
36646366473664836649366503665136652
B5 3D06NB5 3D10NB5 3D16NB5 3D20NB5 3D25NB5 3D32NB5 3D40N
36657366583665936660366613666236663
B5 4D06NB5 4D10NB5 4D16NB5 4D20NB5 4D25NB5 4D32NB5 4D40N
366683666936670366713667236673366741
2
N
N
Rated CurrentNumber of poles
1
2
3
4
3
2-25www.sassin.com
Miniature Circuit BreakersSeries 3SB5
Modular Devices
www.sassin.com2-26
Mod
ular
Dev
ices
Miniature Circuit BreakersSeries 3SB5
Tripping characteristic curves
IEC 60898 Standard
B C D0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C, D.
The release is initiated by a bimetal strip in case of overload.The standard defines the range of release for specific overload values.Reference ambient temperature is 30 ℃.
Testcurrent
Trippingtime
1.13 In
1.45 In
2.55 IN1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
Magnetic release
0.1 < t < 45s (In ≤ 32A)0.1 < t < 90s (In > 32A)t < 0.1s0.1 < t < 15s (In ≤ 32A)0.1 < t < 30s (In > 32A)t < 0.1s0.1 < t < 4s (In ≤ 32A)0.1 < t < 8s (In > 32A)t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTestCurrent
TrippingTime
Control and protection of circuitshaving important transient inrushcurrents (large motors)
Usual loads such as:- lighting- socket outlets- small motors
3 In
5 In
5 In
10 In
20 In
B
C
D
Thermal release
Outline and installation dimensions
unit in mm
79
3583
75
80
35.6
53.4
71.2
3SB5─63C(XX)
230/400V~
※※※※A
GB10963.1
1 3 5 7
2 4 6 8
ONOFF
O-OFF O-OFF O-OFF O-OFF
10 In
17.8
Functions
Overload protectionShort circuit protectionIsolationControllingInterlocking the two miniature circuit breakers
Technical specifications
Standard: IEC 60898-1Approvals: CERated current In (A): 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.: 24Max.: 250/440Rated insulation voltage (VAC): 500Number of poles: 1, 2Tripping characteristics: CCharacteristic curve C (In): 5-10Thermal operating limit (In): 1.13 - 1.45Rated switching capacity Icn (KA): 6 (In:6~40A)Degree of protection: IP20, with connected conductorsElectrical life (times): 4,000Mechanical life (times): 10,000Breaking Capacity:
Mounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35 Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque ( ): 2.5 Ambient temperature (℃): -25~+45, max. 95 % humidityStorage temperature (℃): -40~+75Altitude Max.(meters): 2,000
N • m
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes(ON/OFF)The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationThis MCB for household in accordance with: IEC 60898-1, C tripping characteristicsManual reversing normal and replacement devicesNormal device with grey handle and replacement withred handle
Features
Instruction of type code
Rated current (A): 10, 16, 20, 25, 32, 40, 50, 63
Tripping characteristic type: C
Interlocking codeSeries code
Breaking capacity code
Number of poles: 1, 2
B5 K 2 C 32 T
2-27www.sassin.com
Modular Devices
Mechanical Interlocking Miniature Circuit BreakersSeries 3SB5K
Tripping characteristic curves
C 0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
Model Rated Voltage Acc.to IEC60898-1 Icn (kA) Ics (kA)
1P 230 10-63 3 3 (V )
2P 400 10-63 3 33SB5KT
3SB5KD50-63 4.5 4.5 10-40 6 6
50-63 4.5 4.5 10-40 6 6
Rated Current(A)
1P
2P 400
230
2-28 www.sassin.com
Mod
ular
Dev
ices
In(A) Type code Order codeCurve C
Selection and ordering data
IEC60898-1 3kA1
Rated currentNumber of poles
5063
B5K 1C50T 38170B5K 1C63T 38171
2
IEC60898-1 6kA1
Number of poles In(A)
Rated current
101620253240
101620253240
2
Type code Order codeCurve C
B5K 2C10NB5K 2C16NB5K 2C20NB5K 2C25NB5K 2C32NB5K 2C40N
B5K 1C10N B5K 1C16N 38147B5K 1C20N 38148B5K 1C25N 38149B5K 1C32N 38150B5K 1C40N 38151
38146
38155 38156 38157 38158 38159 38160
Mechanical Interlocking Miniature Circuit BreakersSeries 3SB5K
IEC60898-1 4.5kA1
Number of poles
2
In(A)Rated current
5063
5063
Type code Order codeCurve C
B5K 1C50D 38134B5K 1C63D 38135
B5K 2C50D 38143B5K 2C63D 38144
101620253240
B5K 1C10T B5K 1C16T 38165B5K 1C20T 38166B5K 1C25T 38167B5K 1C32T 38168B5K 1C40T 38169
38164
5063
B5K 2C50T 38179B5K 2C63T 38180
101620253240
B5K 2C10T B5K 2C16T 38174B5K 2C20T 38175B5K 2C25T 38176B5K 2C32T 38177B5K 2C40T 38178
38173
2-29www.sassin.com
IEC60898-13-5
5-1010-14
IEC60947-248
12
Modular Devices
Functions
Overload protectionShort circuit protectionIsolationControllingUsed in residential building, non-residential building, energy source industry and infrastructure.
Technical specifications
Standards: IEC 60898-1, IEC 60947-2Approvals: CE, TUV, CBRated current In(A): 1, 2,3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400Operational voltage (VAC):Min.: 24Max.: 250/440Rated insulation voltage (VAC): 500Number of poles: 1, 2, 3, 4Tripping characteristicsCharacteristic curve B (In) Characteristic curve C (In) Characteristic curve D (In) Thermal operating limit (In) : 1.13 - 1.45 Rated switching capacity Icn (kA): 6 Degree of protection: IP20, with connected conductorsElectrical life (times): 4,000Mechanical life (times): 10,000Breaking Capacity:
Mounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35 Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque ( ): 2.5 Ambient temperature (℃): -25~+45, max. 95 % humidityStorage temperature (℃): -40 ~+75Altitude(meters): Max. 2,000
N • m
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes(ON/OFF)The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationThis MCB for household in accordance with IEC 60898-1, B, C and D tripping characteristicsThis MCB for industry in accordance with IEC 60947-2 instantaneous tripping release ranges B: 4In, release C: 8In, release D: 12InThis MCB may be extended with: A wide range of RCDsFull sets Full sets of accessories
additional components
Features
Auxiliaries
Add-on devices
Instruction of type code
ReferencesAdditional components: page 66Accessories: page 114~116
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles: 1, 2, 3, 4Standard code: 8 (IEC 60898), 9 (IEC 60947)
B52 8 3 C 32 N
Series code
Tripping characteristic type: B, C, D
Rated current (A): Breaking capacity code
Miniature Circuit BreakersSeries 3SB52
Model Rated Voltage Acc.to IEC60898-1 Icn (kA) Ics (kA)
1P 230/4001-4 4.5 4.5 6 6
(V )
3SB52
Rated Current(A)
2-4P 400
Acc.to IEC60947-2
6-40 6 6 6 650-63 4.5 4.5 6 61-4 4.5 4.5 6 66-40 6 6 6 650-63 4.5 4.5 6 6
Icu (kA) Ics (kA)
www.sassin.com
Miniature Circuit BreakersSeries 3SB52
2-30
Pozidriv and slot screw head.Torque up to 4. N •m
Mod
ular
Dev
ices
Benefits
Attractive device designEasily recognizable, color-coded switching position Indication integrated in the handle.
Ergonomic handle for user- friendly switching
Safety terminal: - easy wiring- protection degree IP20.
123456789
1011
1 2 Type3 4 5 6 Breaking capacity 7 Energy level8 9
Brand
Rated current Tripping type
Rated Voltage
ApprovalsStandard
10 ON/OFF indication 11 Electrical wiring diagram
MCB's and RCCB's can be connectedwith PIN type busbar at the top and bottom terminals, with easy DIN-rail extraction.
Well matched with RCCB 3SL52
Auxiliary contacts can be added onthe left hand side of the MCB.
Square terminal version for joint accommodation of pin busbars and cables
Groove designed on both sides to lower temperature rise
2-31www.sassin.com
Miniature Circuit BreakersSeries 3SB52
Modular Devices
Pack.Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
Selection and ordering data
IEC60898-112121212121212121212121212
18590185911859218593185941859518596185971859818599186001860118602
B52 81B01DB52 81B02DB52 81B03DB52 81B04DB52 81B06NB52 81B10NB52 81B16NB52 81B20NB52 81B25NB52 81B32NB52 81B40NB52 81B50DB52 81B63D
B52 82B01DB52 82B02DB52 82B03DB52 82B04DB52 82B06NB52 82B10NB52 82B16NB52 82B20NB52 82B25NB52 82B32NB52 82B40NB52 82B50DB52 82B63D
13294132951329613297132981329913300133011330213303133041330513306
B52 83B01DB52 83B02DB52 83B03DB52 83B04DB52 83B06NB52 83B10NB52 83B16NB52 83B20NB52 83B25NB52 83B32NB52 83B40NB52 83B50DB52 83B63D
13307133081330913310133111331213313133141331513316133171331813319
B52 84B01DB52 84B02DB52 84B03DB52 84B04DB52 84B06NB52 84B10NB52 84B16NB52 84B20NB52 84B25NB52 84B32NB52 84B40NB52 84B50DB52 84B63D
13320133211332213323133241332513326133271332813329133301333113332
B52 81C01DB52 81C02DB52 81C03DB52 81C04DB52 81C06NB52 81C10NB52 81C16NB52 81C20NB52 81C25NB52 81C32NB52 81C40NB52 81C50DB52 81C63D
B52 82C01DB52 82C02DB52 82C03DB52 82C04DB52 82C06NB52 82C10NB52 82C16NB52 82C20NB52 82C25NB52 82C32NB52 82C40NB52 82C50DB52 82C63D
13333133341333513336133371333813339133401334113342133431334413345
13346133471334813349133501335113352133531335413355133561335713358
B52 83C01DB52 83C02DB52 83C03DB52 83C04DB52 83C06NB52 83C10NB52 83C16NB52 83C20NB52 83C25NB52 83C32NB52 83C40NB52 83C50DB52 83C63D
B52 84C01DB52 84C02DB52 84C03DB52 84C04DB52 84C06NB52 84C10NB52 84C16NB52 84C20NB52 84C25NB52 84C32NB52 84C40NB52 84C50DB52 84C63D
13359133601336113362133631336413365133661336713368133691337013371
13372133731337413375133761337713378133791338013381133821338313384
B52 81D01DB52 81D02DB52 81D03DB52 81D04DB52 81D06NB52 81D10NB52 81D16NB52 81D20NB52 81D25NB52 81D32NB52 81D40NB52 81D50DB52 81D63D
13385133861338713388133891339013391133921339313394133951339613397
B52 82D01DB52 82D02DB52 82D03DB52 82D04DB52 82D06NB52 82D10NB52 82D16NB52 82D20NB52 82D25NB52 82D32NB52 82D40NB52 82D50DB52 82D63D
13398133991340013401134021340313404134051340613407134081340913410
B52 83D01DB52 83D02DB52 83D03DB52 83D04DB52 83D06NB52 83D10NB52 83D16NB52 83D20NB52 83D25NB52 83D32NB52 83D40NB52 83D50DB52 83D63D
13411134121341313414134151341613417134181341913420134211342213423
B52 84D01DB52 84D02DB52 84D03DB52 84D04DB52 84D06NB52 84D10NB52 84D16NB52 84D20NB52 84D25NB52 84D32NB52 84D40NB52 84D50DB52 84D63D
13424134251342613427134281342913430134311343213433134341343513436
6
6
4
4
3
3
1
2
In(A)12346
1016202532405063
12346
1016202532405063
12346
1016202532405063
12346
1016202532405063
Rated CurrentIcn(A)
4.54.54.54.56666666
4.54.5
4.54.54.54.56666666
4.54.5
4.54.54.54.56666666
4.54.5
4.54.54.54.56666666
4.54.5
1
Number of poles
2
3
4
www.sassin.com
Miniature Circuit BreakersSeries 3SB52
1-32
Mod
ular
Dev
ices
In(A) Pack.Type Code Order CodeCurve B Curve C Curve D
Type Code Order Code Type Code Order Code
Selection and ordering data
IEC60947-2 6kA12346
1016202532405063
12121212121212121212121212
12346
1016202532405063
6
6
12346
1016202532405063
4
4
12346
1016202532405063
3
3
B52 91B01NB52 91B02NB52 91B03NB52 91B04NB52 91B06NB52 91B10NB52 91B16NB52 91B20NB52 91B25NB52 91B32NB52 91B40NB52 91B50NB52 91B63N
19556 19557 19558 19559 19560 19561 19562 19563 19564 19565 19566 19567 19568
B52 92B01NB52 92B02NB52 92B03NB52 92B04NB52 92B06NB52 92B10NB52 92B16NB52 92B20NB52 92B25NB52 92B32NB52 92B40NB52 92B50NB52 92B63N
19569 19570 19571 19572 19573 19574 19575 19576 19577 19578 19579 19580 19581
B52 93B01NB52 93B02NB52 93B03NB52 93B04NB52 93B06NB52 93B10NB52 93B16NB52 93B20NB52 93B25NB52 93B32NB52 93B40NB52 93B50NB52 93B63N
19582 19583 19584 19585 19586 19587 19588 19589 19590 19591 19592 19593 19594
B52 94B01NB52 94B02NB52 94B03NB52 94B04NB52 94B06NB52 94B10NB52 94B16NB52 94B20NB52 94B25NB52 94B32NB52 94B40NB52 94B50NB52 94B63N
19595 19596 19597 19598 19599 19600 19601 19602 19603 19604 19605 19606 19607
B52 92C01NB52 92C02NB52 92C03NB52 92C04NB52 92C06NB52 92C10NB52 92C16NB52 92C20NB52 92C25NB52 92C32NB52 92C40NB52 92C50NB52 92C63N
19621 19622 19623 19624 19625 19626 19627 19628 19629 19630 19631 19632 19633
B52 93C01NB52 93C02NB52 93C03NB52 93C04NB52 93C06NB52 93C10NB52 93C16NB52 93C20NB52 93C25NB52 93C32NB52 93C40NB52 93C50NB52 93C63N
19634 19635 19636 19637 19638 19639 19640 19641 19642 19643 19644 19645 19646
B52 94C01NB52 94C02NB52 94C03NB52 94C04NB52 94C06NB52 94C10NB52 94C16NB52 94C20NB52 94C25NB52 94C32NB52 94C40NB52 94C50NB52 94C63N
19647 19648 19649 19650 19651 19652 19653 19654 19655 19656 19657 19658 19659
19608 19609 19610 19611 19612 19613 19614 19615 19616 19617 19618 19619 19620
B52 91C01NB52 91C02NB52 91C03NB52 91C04NB52 91C06NB52 91C10NB52 91C16NB52 91C20NB52 91C25NB52 91C32NB52 91C40NB52 91C50NB52 91C63N
B52 91D01NB52 91D02NB52 91D03NB52 91D04NB52 91D06NB52 91D10NB52 91D16NB52 91D20NB52 91D25NB52 91D32NB52 91D40NB52 91D50NB52 91D63N
19660 19661 19662 19663 19664 19665 19666 19667 19668 19669 19670 19671 19672
B52 92D01NB52 92D02NB52 92D03NB52 92D04NB52 92D06NB52 92D10NB52 92D16NB52 92D20NB52 92D25NB52 92D32NB52 92D40NB52 92D50NB52 92D63N
19673 19674 19675 19676 19677 19678 19679 19680 19681 19682 19683 19684 19685
B52 93D01NB52 93D02NB52 93D03NB52 93D04NB52 93D06NB52 93D10NB52 93D16NB52 93D20NB52 93D25NB52 93D32NB52 93D40NB52 93D50NB52 93D63N
19686 19687 19688 19689 19690 19691 19692 19693 19694 19695 19696 19697 19698
B52 94D01NB52 94D02NB52 94D03NB52 94D04NB52 94D06NB52 94D10NB52 94D16NB52 94D20NB52 94D25NB52 94D32NB52 94D40NB52 94D50NB52 94D63N
19699 19700 19701 19702 19703 19704 19705 19706 19707 19708 19709 19710 19711
Rated Current
1
Number of poles
2
3
41
2
2-33www.sassin.com
Miniature Circuit BreakersSeries 3SB52
Modular Devices
Tripping characteristic curves
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898-1 distinguishes three different types, following the current for instantaneous release: type B, C, D.
IEC 60898-1 Standard
B C D0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
The release is initiated by a bimetal strip in case of overload.The standard defines the range of release for specific overload values.Reference ambient temperature is 30 ℃
TestCurrent
Tripping Time
1.13 In
1.45 In
2.55 IN1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
IEC 60947-2 Standard
Magnetic release
An electromagnet with plunger ensuresinstantaneous tripping in case of short circuit. The standard leaves the calibration of magnetic release
,to manufacturer s decision.SASSIN MCB Series 3SB52 Voltgae offers instantaneoustripping rangesrelease B: 4Inrelease C: 8 In release D:12 In
Thermal release
The release is initiated by a bimetal strip in case of overload.the standard defines the range of release for two specific overload values.Reference ambient temperature is 30℃ for 3SB52
TestCurrent
TrippingTime
1.05 In
1.30 In
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
B C D
3 5 10
1.301.05
10.01
0.1
1
10
60120
3600
t (s)
14
Magnetic release
0.1 < t < 45s (In ≤ 32A)0.1 < t < 90s (In > 32A)t < 0.1s0.1 < t < 15s (In ≤ 32A)0.1 < t < 30s (In > 32A)t < 0.1s0.1 < t < 4s (In ≤ 32A)0.1 < t < 8s (In > 32A)t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTestCurrent
TrippingTime
Control and protection of circuitshaving important transient inrushcurrents (large motors)
Usual loads such as:- lighting- socket outlets- small motors
3 In
5 In
10 In
B
C
D
Thermal release
5 In
10 In
20 In
www.sassin.com
Miniature Circuit BreakersSeries 3SB52
2-34
Mod
ular
Dev
ices
Outline and installation dimensions
unit in mm
Max
84.3
34.5
71±0.3
Max76.5
2P: 36Max
3P: 54Max
4P: 72Max
3SB52-63
1 3 5 7
2 4 6 8
230V/400V~
IEC 60898
GB 10963 ON
OFF
®
Temperature derating
The maximum permissible current in a circuit breaker depends on the ambient temperature where the circuit breaker is installed. Ambient temperature is the temperature inside the enclosure or switchboard in which the circuit breakers are installed.The reference temperature is 30℃
1 6
10~32
40~60
~
Temperature compensation coefficient under various operational temperature
1.20
1.18
1.16
1.14
1.12
1.12
1.09
1.08
1.07
1.05
1.04
1.03
1.00
1.00
1.00
0.96
0.96
0.97
0.80
0.92
0.87
0.75
0.88
0.83
0.70
0.84
0.80
Rated current In (A)-10 0 10 20 30 40 50 55 60℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃ ℃
1P: 18Max
2-35www.sassin.com
Modular Devices
Miniature Circuit BreakersSeries 3SB1-63N
Function
Overload protectionShort circuit protectionIsolationControllingUsed in residential building, non-residential building, energy source industry and infrastructure.
Technical specifications
Standard : IEC 60898-1Approvals: CE, SEMKO, CBRated current In(A): 1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.: 24Max.: 250/440Rated insulation voltage (VAC): 500 Number of poles: 1, 2, 3, 4Tripping characteristic: B, C, DCharacteristic curve B (In): 3-5 Characteristic curve C (In): 5-10Characteristic curve D (In) : 10-20Thermal operating limit (In): 1.13 - 1.45Rated switching capacity Icn (KA): 4.5 Degree of protection: IP20, with connected conductorsElectrical life (times): 4,000Mechanical life (times): 10,000Breaking Capacity:
Mounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35 Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque ( ): 2.5Ambient temperature (℃): -25~+45, max. 95 % humidityStorage temperature (℃): -40~+75Altitude (meters): Max. 2,000
N • m
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes(ON/OFF)The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationThis MCB for household in accordance with: IEC 60898- B, C and D tripping characteristicsThis MCB may be extended with: A wide range of RCDsFull sets of Full sets of accessories
additional components
Features
Add-on devices
Instruction of type code
Auxiliaries:
References
Additional components: page 67Accessories: page 114~116
Series code
Tripping characteristic type: B, C, D
Rated current (A): Breaking capacity code
1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63
Number of poles: 1, 2, 3, 4
B1N 3 C 32 D
Model Rated voltage Acc.to IEC60898-1 Icn (kA) Ics (kA)
1P 230/400 4.5 4.5 (V )
2-4P 400 4.5 4.53SB1-63N
Mod
ular
Dev
ices
www.sassin.com
Miniature Circuit BreakersSeries 3SB1-63N
2-36
In(A)
1
12346
1016202532405063
20945209462094720948209492095020951209522095320954209552095620957
20958209592096020961209622096320964209652096620967209682096920970
20971209722097320974209752097620977209782097920980209812098220983
20984209852098620987209882098920990209912099220993209942099520996
Pack.12121212121212121212121212
Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
12346
1016202532405063
6666666666666
12346
1016202532405063
4444444444444
12346
1016202532405063
3333333333333
1
2
Selection and ordering data
IEC60898-1 3kAB1N 1B01TB1N 1B02TB1N 1B03TB1N 1B04TB1N 1B06TB1N 1B10TB1N 1B16TB1N 1B20TB1N 1B25TB1N 1B32TB1N 1B40TB1N 1B50TB1N 1B63T
B1N 1C01TB1N 1C02TB1N 1C03TB1N 1C04TB1N 1C06TB1N 1C10TB1N 1C16TB1N 1C20TB1N 1C25TB1N 1C32TB1N 1C40TB1N 1C50TB1N 1C63T
B1N 1D01TB1N 1D02TB1N 1D03TB1N 1D04TB1N 1D06TB1N 1D10TB1N 1D16TB1N 1D20TB1N 1D25TB1N 1D32TB1N 1D40TB1N 1D50TB1N 1D63T
B1N 2B01TB1N 2B02TB1N 2B03TB1N 2B04TB1N 2B06TB1N 2B10TB1N 2B16TB1N 2B20TB1N 2B25TB1N 2B32TB1N 2B40TB1N 2B50TB1N 2B63T
B1N 3B01TB1N 3B02TB1N 3B03TB1N 3B04TB1N 3B06TB1N 3B10TB1N 3B16TB1N 3B20TB1N 3B25TB1N 3B32TB1N 3B40TB1N 3B50TB1N 3B63T
B1N 2C01TB1N 2C02TB1N 2C03TB1N 2C04TB1N 2C06TB1N 2C10TB1N 2C16TB1N 2C20TB1N 2C25TB1N 2C32TB1N 2C40TB1N 2C50TB1N 2C63T
B1N 3C01TB1N 3C02TB1N 3C03TB1N 3C04TB1N 3C06TB1N 3C10TB1N 3C16TB1N 3C20TB1N 3C25TB1N 3C32TB1N 3C40TB1N 3C50TB1N 3C63T
B1N 2D01TB1N 2D02TB1N 2D03TB1N 2D04TB1N 2D06TB1N 2D10TB1N 2D16TB1N 2D20TB1N 2D25TB1N 2D32TB1N 2D40TB1N 2D50TB1N 2D63T
B1N 3D01TB1N 3D02TB1N 3D03TB1N 3D04TB1N 3D06TB1N 3D10TB1N 3D16TB1N 3D20TB1N 3D25TB1N 3D32TB1N 3D40TB1N 3D50TB1N 3D63T
B1N 4B01TB1N 4B02TB1N 4B03TB1N 4B04TB1N 4B06TB1N 4B10TB1N 4B16TB1N 4B20TB1N 4B25TB1N 4B32TB1N 4B40TB1N 4B50TB1N 4B63T
B1N 4C01TB1N 4C02TB1N 4C03TB1N 4C04TB1N 4C06TB1N 4C10TB1N 4C16TB1N 4C20TB1N 4C25TB1N 4C32TB1N 4C40TB1N 4C50TB1N 4C63T
B1N 4D01TB1N 4D02TB1N 4D03TB1N 4D04TB1N 4D06TB1N 4D10TB1N 4D16TB1N 4D20TB1N 4D25TB1N 4D32TB1N 4D40TB1N 4D50TB1N 4D63T
Rated CurrentNumber of poles
2
3
4
20997209982099921000210012100221003210042100521006210072100821009
21010210112101221013210142101521016210172101821019210202102121022
21023210242102521026210272102821029210302103121032210332103421035
21036210372103821039210402104121042210432104421045210462104721048
21049210502105121052210532105421055210562105721058210592106021061
21062210632106421065210662106721068210692107021071210722107321074
21075210762107721078210792108021081210822108321084210852108621087
21088210892109021091210922109321094210952109621097210982109921100
Modular Devices
2-37www.sassin.com
Miniature Circuit BreakersSeries 3SB1-63N
In(A)12346
1016202532405063
23382 2343423383 2343523384 2343623385 2343723386 2343823387 2343923388 2344023389 2344123390 2344223391 2344323392 2344423393 2344523394 23446
Pack.23486 1223487 1223488 1223489 1223490 1223491 1223492 1223493 1223494 1223495 1223496 1223497 1223498 12
Type code Order codeCurve B Curve C Curve D
Type code Order code Type code Order code
12346
1016202532405063
23395 2344723396 2344823397 2344923398 2345023399 2345123400 2345223401 2345323402 2345423403 2345523404 2345623405 2345723406 2345823407 23459
666666666666
23499235002350123502235032350423505235062350723508235092351023511 6
12346
1016202532405063
23408234092341023411234122341323414234152341623417234182341923420
23460234612346223463234642346523466234672346823469234702347123472
23512235132351423515235162351723518235192352023521235222352323524
4444444444444
12346
1016202532405063
23421 23473 23525 323422 23474 23526 323423 23475 23527 323424 23476 23528 323425 23477 23529 323426 23478 23530 323427 23479 23531 323428 23480 23532 323429 23481 23533 323430 23482 23534 323431 23483 23535 323432 23484 23536 323433 23485 23537 3
Selection and ordering data
IEC60898-1 4.5kAB1N 1B01DB1N 1B02DB1N 1B03DB1N 1B04DB1N 1B06DB1N 1B10DB1N 1B16DB1N 1B20DB1N 1B25DB1N 1B32DB1N 1B40DB1N 1B50DB1N 1B63D
B1N 1C01DB1N 1C02DB1N 1C03DB1N 1C04DB1N 1C06DB1N 1C10DB1N 1C16DB1N 1C20DB1N 1C25DB1N 1C32DB1N 1C40DB1N 1C50DB1N 1C63D
B1N 1D01DB1N 1D02DB1N 1D03DB1N 1D04DB1N 1D06DB1N 1D10DB1N 1D16DB1N 1D20DB1N 1D25DB1N 1D32DB1N 1D40DB1N 1D50DB1N 1D63D
B1N 2B01DB1N 2B02DB1N 2B03DB1N 2B04DB1N 2B06DB1N 2B10DB1N 2B16DB1N 2B20DB1N 2B25DB1N 2B32DB1N 2B40DB1N 2B50DB1N 2B63D
B1N 3B01DB1N 3B02DB1N 3B03DB1N 3B04DB1N 3B06DB1N 3B10DB1N 3B16DB1N 3B20DB1N 3B25DB1N 3B32DB1N 3B40DB1N 3B50DB1N 3B63D
B1N 2C01DB1N 2C02DB1N 2C03DB1N 2C04DB1N 2C06DB1N 2C10DB1N 2C16DB1N 2C20DB1N 2C25DB1N 2C32DB1N 2C40DB1N 2C50DB1N 2C63D
B1N 3C01DB1N 3C02DB1N 3C03DB1N 3C04DB1N 3C06DB1N 3C10DB1N 3C16DB1N 3C20DB1N 3C25DB1N 3C32DB1N 3C40DB1N 3C50DB1N 3C63D
B1N 2D01DB1N 2D02DB1N 2D03DB1N 2D04DB1N 2D06DB1N 2D10DB1N 2D16DB1N 2D20DB1N 2D25DB1N 2D32DB1N 2D40DB1N 2D50DB1N 2D63D
B1N 3D01DB1N 3D02DB1N 3D03DB1N 3D04DB1N 3D06DB1N 3D10DB1N 3D16DB1N 3D20DB1N 3D25DB1N 3D32DB1N 3D40DB1N 3D50DB1N 3D63D
B1N 4B01DB1N 4B02DB1N 4B03DB1N 4B04DB1N 4B06DB1N 4B10DB1N 4B16DB1N 4B20DB1N 4B25DB1N 4B32DB1N 4B40DB1N 4B50DB1N 4B63D
B1N 4C01DB1N 4C02DB1N 4C03DB1N 4C04DB1N 4C06DB1N 4C10DB1N 4C16DB1N 4C20DB1N 4C25DB1N 4C32DB1N 4C40DB1N 4C50DB1N 4C63D
B1N 4D01DB1N 4D02DB1N 4D03DB1N 4D04DB1N 4D06DB1N 4D10DB1N 4D16DB1N 4D20DB1N 4D25DB1N 4D32DB1N 4D40DB1N 4D50DB1N 4D63D
Rated CurrentNumber of poles
1
1
2
2
3
4
Mod
ular
Dev
ices
www.sassin.com
Miniature Circuit BreakersSeries 3SB1-63N
2-38
Tripping characteristic curves
IEC 60898 Standard
B C D0.01
0.1
1
10
60120
3600
t (s)
1 3 5 10 202.551.13
1.45In
An electromagnet with plunger ensures instantaneous tripping in case of short circuit. The IEC 60898 distinguishes three different types, following the current for instantaneous release: type B, C, D.
The release is initiated by a bimetal strip in case of overload.The standard defines the range of release for specific overload values.Reference ambient temperature is 30 ℃
TestCurrent
TrippingTime
1.13 In
1.45 In
2.55 In1s < t < 60s (In ≤ 32A)1s < t < 120s (In > 32A)
t≥ 1h (In ≤ 63A)
t< 1h (In ≤ 63A)
Magnetic release
0.1 < t < 45s (In ≤ 32A)0.1 < t < 90s (In > 32A)t < 0.1s0.1 < t < 15s (In ≤ 32A)0.1 < t < 30s (In > 32A)t < 0.1s0.1 < t < 4s (In ≤ 32A)0.1 < t < 8s (In > 32A)t < 0.1s
Only for resistive loads such as:- electrical heating- water heater- stoves
ApplicationsTestCurrent
TrippingTime
Control and protection of circuitshaving important transient inrushcurrents (large motors)
Usual loads such as:- lighting- socket outlets- small motors
3 In
5 In
5 In
10 In
10 In
20 In
B
C
D
Thermal release
Outline and installation dimensions
unit in mm
4P
3P
2P
1P
7254
36
18
80
45
83 37
73.561.5
43.55.5
Modular Devices
2-39www.sassin.com
Miniature Circuit BreakersSeries 3SB1-125
Functions
Overload protectionShort circuit protectionIsolationUsed in residential building, non-residential building, energy sources, industry and infrastructure.
Technical specifications
Standard: IEC 60947-2Approval: CERated current In (A): 63, 80, 100, 125Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.: 24Max.: 250/440Rated insulation voltage (VAC): 500Number of poles: 1, 2, 3, 4Tripping characteristics: B, C, Drelease B (In) : 4release C (In) : 8release D (In): 14Thermal operating limit (In): 1.05 - 1.30Electrical life (times): 4,000Mechanical life (times): 20,000Breaking Capacity:
Degree of protection: IP20, with connected conductorsMounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 1-50 Finely stranded with end sleeve (mm²): 1-35Terminal tightening torque ( ): 3.5 Ambient temperature (℃): -25~+45, max. 95 % humidityStorage temperature (℃): -40~+75Altitude Max(meters): 2,000 Connection Capacity (mm²): 1-35
N • m
Rated current up to 125AThe handle being sealable or equipped with padlock bracket avoids dangerous operation changes(ON/OFF)The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationThis MCB for industry in accordance with: IEC 60947-2 instantaneous tripping release ranges B: 4In, release C:8In , release D: 12InThis MCB may be extended with: A wide range of RCDs and RCBOFull sets of Full sets of accessories
additional components
Features
Add-on devices
Instruction of type code
Auxiliaries:
References
Additional components: page 67Accessories: page 114~116
Series code
Tripping characteristic type: B, C, DRated current (A): 63, 80,100,125
Number of poles: 1, 2, 3, 4
C125 3 C 063
Model Rated voltage Acc.to IEC60947-2 Icu (kA) Ics (kA)
1P 230/400 6 6 (V )
2-4P 400 6 63SB1-125
www.sassin.com
Miniature Circuit BreakersSeries 3SB1-125
2-40
Mod
ular
Dev
ices
Selection and ordering data
IEC60947-2 6kA In(A) Pack.Curve C Curve D
1C125 1C063 21152 C125 1D063 21164C125 1C080 21153 C125 1D080 21165C125 1C100 21154 C125 1D100 21166C125 1C125 23581 C125 1D125 23585
6380
100125
8888
Type code Order code Type code Order code
6380
100125
4444
C125 2C063 21155 C125 2D063 21167C125 2C080 21156 C125 2D080 21168C125 2C100 21157 C125 2D100 21169C125 2C125 23582 C125 2D125 23586
36380
100125
C125 3C063 21158 C125 3D063 21170C125 3C080 21159 C125 3D080 21171C125 3C100 21160 C125 3D100 21172C125 3C125 23583 C125 3D125 23587
3333
80100125
C125 4C06363 21161 C125 4D063 21173C125 4C080 21162 C125 4D080 21174C125 4C100 21163 C125 4D100 21175C125 4C125 23584 C125 4D125 23588
22221
2
Number of poles
Rated current
2
4
Outline and installation dimensions
unit in mm
I
0 OFF
ON
3SB1 - 125C63230V/400V
1 3
2 4
5
6
7
8
GB14048.2IEC60947-2
108
8154
271P2P3P4P
45
7750 16
81
Curve B
C125 1B063C125 1B080C125 1B100C125 1B125
Type code Order code
C125 2B063C125 2B080C125 2B100C125 2B125
C125 3B063C125 3B080C125 3B100C125 3B125
C125 4B063C125 4B080C125 4B100C125 4B125
2114021141
21146211472114823579
2114223577
21143211442114523578
21149211502115123580
2-41www.sassin.com
Modular Devices
Instruction of type code
Breaking capacity code
Rated current(A)10,16,20,25,32,40,50,63 Tripping characteristic type: C
Number of poles: 1P+N, 3P+NSeries code
Functions
Remote controlled circuit breaking
Overload protection Short circuit protection Isolation Used in residential building, non- residential building, industry, energy and infrastructure.
Technical specifications
Standards: IEC60898-1Approvals:CERated current In (A) :10, 16, 20, 25, 32, 40, 50, 63Rated voltage Un (VAC): 230/400 Operational voltage (VAC):Min.24 Max. 250/440Rated frequency (Hz):50/60 Rated insulation voltage (VAC): 500Number of poles: 1P+N, 3P+NTripping characteristic: CCharacteristic curve C ( In) :5-10 Thermal operating limit ( In): 1.13 - 1.45 Rated switching capacity Icn (kA): 4.5Degree of protection: IP20, with connected conductorsElectrical life (times) : 4,000Mechanical life (times): 10,000Breaking Capacity:
Shunt release time range: 0.5s-2sReset time range: <30sMounting position: AnyConductor cross-sections
2Solid and stranded (mm ): 0.75-35 2Finely stranded with end sleeve (mm ): 0.75-25
Terminal tightening torque (N • m): 2.8Ambient temperature (℃): -25 ~ +45, max. 95 % humidityStorage temperature (℃) : -40 ~ +75 Altitude (meters) :Max 2,000
Features:
Received the signal to cut off the circuit within 0.5s-2s; This MCB for household in accordance with IEC 60898-1, C tripping characteristics Adequate printing of all datas on the front provides long- term identification
B1S 3 C 32 D
Tripping characteristic curves
IEC 60898-1 Standard
C 0.01
0.1
1
10
60120
3600
t (s)
1 3 5 102.551.13
1.45In
Shunt Release Circuit Breaker Series 3SB1S-63
Model Rated Voltage Acc.to IEC60898-1 Icn (kA) Ics (kA)
1P+N 230/400 (V )
3SB1S-63
Rated Current(A)
3P+N 40010-63 3 3
1P+N 230/400
3P+N 400
10-40 6 6 50-63 4.5 4.5 10-40 6 6 50-63 4.5 4.5
Selection and ordering data
In(A) Type code Order codeCurve C
10
2016
253240
153041530515306153071530815309
B1S2C10HIEC60898-1 6kA
Rated current Number of poles
1P+N
B1S2C16HB1S2C20HB1S2C25HB1S2C32HB1S2C40H
10
2016
253240
153111531215313153141531515316
B1S4C10H
3P+N
B1S4C16HB1S4C20HB1S4C25HB1S4C32HB1S4C40H
5063
B1S2C50DB1S2C63D
5063
B1S4C50DB1S4C63D
Outline and installation dimensions
unit in mm3P+N
1P+N
72
36
80
45
83 37
73.561.5
43.55.5
2-42 www.sassin.com
Mod
ular
Dev
ices
Shunt Release Circuit Breaker Series 3SB1S-63
In(A) Type code Order codeCurve C
10
2016
253240
B1S2C10DIEC60898-1 3kA
Rated current Number of poles
1P+NB1S2C16DB1S2C20DB1S2C25DB1S2C32DB1S2C40D
3P+N
10
2016
253240
B1S4C10DB1S4C16DB1S4C20DB1S4C25DB1S4C32DB1S4C40D
152951529615297152981529915300
152861528715288152891529015291
1529215293
1530115302
In(A) Type code Order codeCurve C
IEC60898-1 4.5kARated current Number
of poles
1P+N
3P+N
www.sassin.com 2-43
Modular Devices
Residual Current Circuit Breakers Series3SL71-100
Functions
Switching and isolation function Controlling Protection against the effects of sinusoidal alternating earth fault currents Protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults Used in residential building , non-residential building, energy sources, industry and infrastructure.
Combination with auxiliary elements:
auxiliary contact,signal contact,shunt trip,undervoltage release
Instruction of type code Technical specifications Standard: IEC 61008-1 Approvals: CE, CB, TUV Type (wave form of the earth leakage sensed): AC, A Trip time type: general use, selectivity of S Number of poles: 1P+N, 3P+N Rated current In(A): 16, 25, 4 0 ,63, 80, 100 Rated voltage Ue (VAC): 230/400 Rated insulation voltage Ui (VAC):500 Rated Frequency Fn (Hz): 50/60 Rated residual currents(IΔn)( mA): 10(2P 16A), 30,100,300 Rated conditional short-circuit current : Inc=IΔc= 6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1000 Rated residual breaking capacity IΔm (A): 1000 Degree of protection: IP20, with connected conductors Terminals Terminal tightening torque( ): 3 Ambient temperature (℃): -25 ~ +45, max. 95 % humidity
N • m
Features
Electromagnetic type, voltage independent.
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) - The handle provides a clear indication of the contact position - Adequate printing of all data on the front provides long-term identification
Outline and installation dimensions
unit in mm
Rated residual current
Series code
Rated current
Number of poles: 1P+N, 3P+N
L71 2 C 025 030
Residual trip characteristic type
3SB71C3SB71J
3SB71C3SB71J
3SB71F3SB71Q/L3SB71Q/R
3SL71
86
45
35
17.5
70
45
44
86
17.5 17.5
45
Combination of auxiliary elements with 3SL71
36
17.5
Additional components: page 65~66
www.sassin.com
Residual Current Circuit BreakersSeries 3SL71-100
In(A)16
Selection and ordering data
Type AC
Order code Type code I△n(mA)
30
Rated residualcurrent
Rated current
Type S+AC Type A s
1P+N 10
1625406380100
300
100 1625406380100
1625406380100
30 1625406380100
300
100 1625406380100
1625406380100
N1
2 N
1 3 5 7 N
N8642
L71 2C016/010 36067 L71 2A016/010 36104
L71 2C025/030 36069L71 2C040/030 36070L71 2C063/030 36071L71 2C080/030 36072L71 2C100/030 36073
L71 2A025/030 36106L71 2A040/030 36107L71 2A063/030 36108L71 2A080/030 36109L71 2A100/030 36110
L71 2C025/100 36075L71 2C040/100 36076L71 2C063/100 36077L71 2C080/100 36078L71 2C100/100 36079
L71 2A025/100 36112L71 2A040/100 36113L71 2A063/100 36114L71 2A080/100 36115L71 2A100/100 36116
L71 2C025/300 36081L71 2C040/300 36082L71 2C063/300 36083L71 2C080/300 36084L71 2C100/300 36085
L71 2A025/300 36118L71 2A040/300 36119L71 2A063/300 36120L71 2A080/300 36121L71 2A100/300 36122
L71 4C025/030 36087L71 4C040/030 36088L71 4C063/030 36089L71 4C080/030 36090L71 4C100/030 36091
L71 4A025/030 36124L71 4A040/030 36125L71 4A063/030 36126L71 4A080/030 36127L71 4A100/030 36128
L71 4C025/100 36093L71 4C040/100 36094L71 4C063/100 36095L71 4C080/100 36096L71 4C100/100 36097
L71 4A025/100 36130L71 4A040/100 36131L71 4A063/100 36132L71 4A080/100 36133L71 4A100/100 36134
L71 4C025/300 36099L71 4C040/300 36100L71 4C063/300 36101L71 4C080/300 36102L71 4C100/300 36103
L71 4A025/300 36136L71 4A040/300 36137L71 4A063/300 36138L71 4A080/300 36139L71 4A100/300 36140
L71 2C016/030 36068
L71 4C016/030 36086
L71 2A016/030
L71 4A016/030 36123
L71 2C016/100 36074
L71 4C016/100 36092
L71 2A016/100 36111
L71 4A016/100 36129
L71 2C016/300 36080
L71 4C016/300 36098
L71 2A016/300 36117
L71 4A016/300 36135
Number of poles
3P+N
Types Both RCCBs and RCBOs are further divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Type S : For selectivity, with time delay. Type S : For selectivity, with time delay.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults
I n< 50/R, to provide protection against indirect contactsRCD with a rated residual current of 10 mA are primarily usedin areas that reprent an exist risk for personnel
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
s
s
s
Order code Type code
L71 2SC016/100L71 2SC025/100L71 2SC040/100L71 2SC063/100L71 2SC080/100L71 2SC100/100 L71 2SC016/300L71 2SC025/300L71 2SC040/300L71 2SC063/300L71 2SC080/300L71 2SC100/300
Order code Type code Order code Type code
Type S+A
36105
L71 4SC016/100L71 4SC025/100L71 4SC040/100L71 4SC063/100L71 4SC080/100L71 4SC100/100 L71 4SC016/300L71 4SC025/300L71 4SC040/300L71 4SC063/300L71 4SC080/300L71 4SC100/300
36153 36154 36155 36156 36157 36158 36159 36160 36161 36162 36163 36164
36141 36142 36143 36144 36145 36146 36147 36148 36149 36150 36151 36152
L71 2SA016/100L71 2SA025/100L71 2SA040/100L71 2SA063/100L71 2SA080/100L71 2SA100/100 L71 2SA016/300L71 2SA025/300L71 2SA040/300L71 2SA063/300L71 2SA080/300L71 2SA100/300
36165 36166 36167 36168 36169 36170 36171 36172 36173 36174 36175 36176
L71 4SA016/100L71 4SA025/100L71 4SA040/100L71 4SA063/100L71 4SA080/100L71 4SA100/100 L71 4SA016/300L71 4SA025/300L71 4SA040/300L71 4SA063/300L71 4SA080/300L71 4SA100/300
36177 36178 36179 36180 36181 36182 36183 36184 36185 36186 36187 36188
-
------
-
------
-
------
-
------
------
------
------
------
2-44
Mod
ular
Dev
ices
www.sassin.com
Residual Current Circuit Breakers Series3SL66
2-45
Modular Devices
Functions
Switching and isolation function Controlling Protection against the effects of sinusoidal alternating earth fault currents Protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults Used in residential building , non-residential building, energy sources, industry and infrastructure.
Instruction of type code
Technical specifications Standard: IEC 61008-1 Approvals: CE, SEMKO, CB, TUV Type (wave form of the earth leakage sensed): AC, A Trip time type: general use, selectivity of S Number of poles: 1P+N, 3P+N Rated current In(A): 16, 25, 40, 63, 80, 100 Rated voltage Ue (VAC): 230/400 Rated insulation voltage Ui (VAC): 500 Rated Frequency Fn (Hz): 50/60 Rated residual currents(IΔn)( mA): 10(2P 16A), 30,100,300 Rated conditional short-circuit current : Inc=IΔc= 6000A SCPD fuse 100A Gg Making and breaking capacity Im(A): 1000 Rated residual breaking capacity IΔm(A): 1000 Rated impulse withstand voltage (1.2/50) Uimp(kV): 8 Dielectric test voltage at ind. freq. for 1 min.(kV): 2.5 Electrical life(times): 10,000 Mechanical life(times): 20,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded(mm ): 0.75-35 2 Finely stranded with end sleeve(mm ): 0.75-25
Terminals Terminal tightening torque( ): 3 Ambient temperature (℃): -25 ~ +45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude Max (meters ): 2,000
N • m
Features
Electromagnetic type, voltage independent.
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) - The handle provides a clear indication of the contact position - Adequate printing of all data on the front provides long-term identification
Outline and installation dimensions
unit in mm
70±0.535.5±0.3
88±
1
45
69±1
35
75±1
44
Rated residual current
Series code
Rated current
Number of poles: 1P+N, 3P+N
L66 2 C 025 030
Residual trip characteristic type
www.sassin.com
Residual Current Circuit BreakersSeries 3SL66
In(A)16
Type AC
Order code
Selection and ordering data
Type code Order code Type code I△n(mA)
30
Rated residual Current Rated current
Type A
Order code Type code
Type S s
1P+N, 10
1625406380100
300
100 1625406380100
1625406380100
30 1625406380100
300
100 1625406380100
1625406380100
N1
2 N
1 3 5 7 N
N8642
L66 2C016/010 19496 L66 2A016/010 19497
L66 2C025/030 23073L66 2C040/030 23074L66 2C063/030 23075L66 2C080/030 23076L66 2C100/030 23077
L66 2A025/030 23088L66 2A040/030 23089L66 2A063/030 23090L66 2A080/030 23091L66 2A100/030 23092
L66 2C025/100 23078L66 2C040/100 23079L66 2C063/100 23080L66 2C080/100 23081L66 2C100/100 23082
L66 2A025/100 23093L66 2A040/100 23094L66 2A063/100 23095L66 2A080/100 23096L66 2A100/100 23097
L66 2S025/100 23622L66 2S040/100 23623L66 2S063/100 23624L66 2S080/100 23625L66 2S100/100 23626
L66 2C025/300 23083L66 2C040/300 23084L66 2C063/300 23085L66 2C080/300 23086L66 2C100/300 23087
L66 2A025/300 23098L66 2A040/300 23099L66 2A063/300 23100L66 2A080/300 23101L66 2A100/300 23102
L66 2S025/300 23627L66 2S040/300 23628L66 2S063/300 23629L66 2S080/300 23630L66 2S100/300 23631
L66 4C025/030 23103L66 4C040/030 23104L66 4C063/030 23105L66 4C080/030 23106L66 4C100/030 23107
L66 4A025/030 23118L66 4A040/030 23119L66 4A063/030 23120L66 4A080/030 23121L66 4A100/030 23122
L66 4C025/100 23108L66 4C040/100 23109L66 4C063/100 23110L66 4C080/100 23111L66 4C100/100 23112
L66 4A025/100 23123L66 4A040/100 23124L66 4A063/100 23125L66 4A080/100 23126L66 4A100/100 23127
L66 4S025/100 23681L66 4S040/100 23638L66 4S063/100 23639L66 4S080/100 23640L66 4S100/100 23641
L66 4C025/300 23113L66 4C040/300 23114L66 4C063/300 23115L66 4C080/300 23116L66 4C100/300 23117
L66 4A025/300 23128L66 4A040/300 23129L66 4A063/300 23130L66 4A080/300 23131L66 4A100/300 23132
L66 4S025/300 23642L66 4S040/300 23643L66 4S063/300 23644L66 4S080/300 23645L66 4S100/300 23646
L66 2C016/030 23648
L66 4C016/030 23651
L66 2A016/030 23654
L66 4A016/030 23657
L66 2C016/100 23666
L66 4C016/100 23669
L66 2A016/100 23672
L66 4A016/100 23675
L66 2S016/100 23678
L66 4S016/100 23637
L66 2C016/300 23684
L66 4C016/300 23687
L66 2A016/300 23690
L66 4A016/300 23693
L66 2S016/300 23696
L66 4S016/300 23699
Number of poles
3P+N
Types Both RCCBs and RCBOs are further divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Type S : For selectivity, with time delay.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults
I n< 50/R, to provide protection against indirect contactsRCD with a rated residual current of 10 mA are primarily usedin areas that exist an increased risk for personnel
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
s
2-46
Mod
ular
Dev
ices
www.sassin.com
Residual Current Circuit BreakersSeries3SL6
Modular Devices
2-47
Functions
Standard: IEC 61008-1Approvals: CE, CB, TUVType (wave form of the earth leakage sensed): AC, ATrip time type: general use, selectivity of SNumber of poles(P): 1+N, 3+NRated current In(A): 16, 25, 40 ,63Rated voltage Ue (VAC): 1P+N: 230/400; 3P+N: 400Rated insulation voltage Ui (VAC):500Rated Frequency Fn (Hz): 50/60Rated residual currents(IΔn)( mA): 30, 100, 300Rated conditional short-circuit current :Inc=IΔc= 6000A SCPD fuse 100A GgMaking and breaking capacity Im (A): 1000Rated residual breaking capacity IΔm (A): 1000Degree of protection: IP20, with connected conductorsConductor cross-sectionSolid and stranded(mm²): 1-35Finely stranded with end sleeve (mm²): 1-25Electrical endurance(Cycles): 4,000Mechanical endurance(Cycles): 10,000Fire resistance according to IEC 60695: 960℃Mounting position: AnyBusbar connection: Pin typeTerminal tightening torque( ): 2.5Ambient temperature (℃): -5 ~ +40, max. 95 % humidity
N • m
Features
Electromagnetic type, voltage independent. The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) - Adequate printing of all data on the front provides long-term identification
Outline and installation dimensions
unit in mm
Instruction of type code
Rated residual current
Series code
Rated current
Number of poles: 1P+N, 3P+N
L6 2 C 16 030
Residual trip characteristic type
Switching and isolation functionControllingProtection against the effects of sinusoidal alternating earth fault currentsProtection against indirect contacts and additional protection against direct contacts.Protection against fire hazard caused by insulation faultsUsed in residential building , non-residential building, energy sources, industry and infrastructure.Anti false wiring design to ensure safe wiring
Technical specifications
35 70
44
45
35
84
ma
x
50
77max
2-48 www.sassin.com
Mod
ular
Dev
ices
Residual Current Circuit BreakersSeries3SL6
Selection and ordering data
Type ACOrder code Type code
30
30
Rated residualcurrent
IΔn(mA)
Rated current
In(A) Type S+AC Type A s
1P+N 162540631625406316254063
300
300
100
100
N1
2 N
1 3 5 7 N
N8642
Number of poles
3P+N
Types Both RCCBs and RCBOs are further divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Type S : For selectivity, with time delay.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults
I n< 50/R, to provide protection against indirect contacts
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
s
Order code Type code Order code Type code ----
L6 2SC16/100L6 2SC25/100L6 2SC40/100L6 2SC63/100L6 2SC16/300L6 2SC25/300L6 2SC40/300L6 2SC63/300
----
2121121212212132121421216212172121821219
L6 2C16/030L6 2C25/030L6 2C40/030L6 2C63/030L6 2C16/100L6 2C25/100L6 2C40/100L6 2C63/100L6 2C16/300L6 2C25/300L6 2C40/300L6 2C63/300
L6 2A16/030L6 2A25/030L6 2A40/030L6 2A63/030L6 2A16/100L6 2A25/100L6 2A40/100L6 2A63/100L6 2A16/300L6 2A25/300L6 2A40/300L6 2A63/300
L6 4C16/030L6 4C25/030L6 4C40/030L6 4C63/030L6 4C16/100L6 4C25/100L6 4C40/100L6 4C63/100L6 4C16/300L6 4C25/300L6 4C40/300L6 4C63/300
L6 4A16/030L6 4A25/030L6 4A40/030L6 4A63/030L6 4A16/100L6 4A25/100L6 4A40/100L6 4A63/100L6 4A16/300L6 4A25/300L6 4A40/300L6 4A63/300
----
L6 4SC16/100L6 4SC25/100L6 4SC40/100L6 4SC63/100L6 4SC16/300L6 4SC25/300L6 4SC40/300L6 4SC63/300
211792118021181211822118421185211862118721189211902119121192
211962119721198211992120121202212032120421206212072120821209
212332123421235212362123821239212402124121243212442124521246
212502125121252212532125521256212572125821260212612126221263
----
2126521266212672126821270212712127221273
162540631625406316254063
www.sassin.com 2-49
Modular Devices
Residual Current Circuit Breakers Series3SL52
Benefits
Anti false wiring design to ensure
safe wiring.
MCB’s and RCCB’s can be connected
with both PIN type busbar and FORK
type busbar at the top and bottom
terminals.
N pole mark, quick and easy
identification.
Venting grooves improve heat
dissipation even in multiple
-pole configurations.
Same groove design with MCB 3SB52
series. Well matched during installation.
AIR
FL
OW
Functions
Switching and isolation function Controlling Protection against the effects of sinusoidal alternating earth fault currents Protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults Used in residential building, non-residential building, energy sources, industry and infrastructure.
Instruction of type code
Technical specifications Standard: IEC 61008-1 Approvals: CE, SEMKO, CB, TUV Type (wave form of the earth leakage sensed): AC, A Trip time type: general use, selectivity of S Number of poles: 1P+N, 3P+N Rated current In (A): 16, 25, 40, 63 Rated voltage Ue (VAC): 230/400 Rated insulation voltage Ui (VAC): 500 Rated Frequency Fn (Hz): 50/60 Rated residual currents (IΔn) (mA): 10(2P 16A), 30, 100, 300 Rated conditional short-circuit current : Inc=IΔc= 6000A SCPD fuse 100A Gg Making and breaking capacity Im (A): 1,000 Rated residual breaking capacity IΔm (A): 1,000 Rated impulse withstand voltage (1.2/50) Uimp (kV): 8 Dielectric test voltage at ind. freq. for 1 min.(kV): 2.5 Electrical life(times): 10,000 Mechanical life(times): 20,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded(mm ): 0.75-16 2 Finely stranded with end sleeve(mm ): 0.75-10
Terminals Terminal tightening torque( · ): 2.8 Ambient temperature(℃): -25 ~ +45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude Max( meters): 2,000
N m
Features
Electromagnetic type, voltage independent.
The handle being sealable or equipped with padlock bracket avoids dangerous operation changes (ON / OFF) The handle provides a clear indication of the contact position Adequate printing of all data on the front provides long -term identification
Rated residual current
Series code
Residual trip characteristic type
Rated current
Number of poles 3P+N: 1P+N,
L52 2 C 025 030
Residual Current Circuit BreakersSeries 3SL52
Mod
ular
Dev
ices
2-50 www.sassin.com
In(A)16
Type AC
Selection and ordering data
I△n(mA)
30
100
Rated residual Current Rated current Type A
Order Code Type Code Order Code Type Code Order Code Type Code Type S s
1P+N 10
16254063
16254063
300 16254063
30
100
16254063
16254063
300 16254063
N1
2 N
1 3 5 7 N
N8642
L52 2C16/010 19490 L52 2A16/010 19491
L52 2C16/030 24278 L52 2A16/030 24320L52 2C25/030 24279L52 2C40/030 24281L52 2C63/030 24283
L52 2C16/100 24285L52 2C25/100 24286L52 2C40/100 24288L52 2C63/100 24290
L52 2C16/300 24292L52 2C25/300 24293L52 2C40/300 24295L52 2C63/300 24297L52 4C16/030 24299L52 4C25/030 24300L52 4C40/030 24302L52 4C63/030 24304
L52 4C16/100 24306L52 4C25/100 24307L52 4C40/100 24309L52 4C63/100 24311
L52 4C16/300 24313L52 4C25/300 24314L52 4C40/300 24316L52 4C63/300 24318
L52 2A25/030 24321L52 2A40/030 24323L52 2A63/030 24325
L52 2A16/100 24327L52 2A25/100 24328L52 2A40/100 24330L52 2A63/100 24332
L52 2A16/300 24334L52 2A25/300 24335L52 2A40/300 24337L52 2A63/300 24339L52 4A16/030 24341L52 4A25/030 24342L52 4A40/030 24344L52 4A63/030 24346
L52 4A16/100 24348L52 4A25/100 24349L52 4A40/100 24351L52 4A63/100 24353
L52 4A16/300 24355L52 4A25/300 24356L52 4A40/300 24358L52 4A63/300 24360
L52 2S16/100 24369L52 2S25/100 24370L52 2S40/100 24372L52 2S63/100 24374
L52 2S16/300 24376L52 2S25/300 24377L52 2S40/300 24379L52 2S63/300 24381
L52 4S16/100 24390L52 4S25/100 24391L52 4S40/100 24393L52 4S63/100 24395
L52 4S16/300 24397L52 4S25/300 24398L52 4S40/300 24400L52 4S63/300 24402
Number of poles
Types Both RCCBs and RCBOs are further divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising. Type S : For selectivity, with time delay.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults.
I n< 50/R, to provide protection again indirect contacts.RCD with a rated residual current of 10 mA are primarily used in areas that exist an increased risk for personnel.
RCD with a rated residual current of 100mA co-ordinat with the earth system according to the formula △
s
Outline and installation dimensions
unit in mm
3P+N
35 7044
69
35.5
344.6
84.3 45
www.sassin.com 2-51
Modular Devices
Residual Current Circuit Breakers Series3SL52
Additional components: page 65~66Accessories: page 114~116
Functions
Switching and isolation function Protection against overload and short-circuit currents Protection against the effects of sinusoidal alternating earth fault currents Protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults Used in residential building
Technical specifications Standard: IEC 61009-1 Approval: CE Type (wave form of the earth leakage sensed): AC, A Number of pole: 1P+N Rated current In(A): 6, 10, 16, 20, 25, 32, 40 Rated voltage Ue (VAC): 230 Rated insulation voltage Ui(VAC): 500 Rated Frequency Fn (Hz): 50/60 Rated residual currents IΔn (mA): 30, 100, 300 Rated breaking capacity acc.to IEC61009 ultimate Icn (kA): 6 Rated breaking capacity acc.to IEC60947-2 ultimate Icu (kA): 10 Rated residual breaking capacity IΔm (kA): 6 Rated impulse withstand voltage (1.2/50) Uimp (kV): 8 Dielectric test voltage at ind. freq. for 1 min.(kV): 2.5 Surge current resistance (wave 8/20) (A): 3000 Tripping characteristic: B, C Characteristic B (In): 3-5 Characteristic C (In): 5-10 Electrical life(times): 4,000 Mechanical life(times): 10,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded(mm ) : 0.75-35 2 Finely stranded with end sleeve(mm ): 0.75-25
Terminals Terminal tightening torque( ): 2.8 Ambient temperature (℃): -25~ +45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude Max (meters ): 2000
N•m
Features
The combination of an RCCB and a miniature circuit breaker in a compact design for personnel, fire and line protection. Electromagnetic type, voltage independent. The MCB part protects lines against overload and short circuits and is available in characteristics B and C. The handle provides a clear indication of the contact position. The earth reference cable ensures protection against earth leakage in case of loss of supply neutral.
Instruction of type code
Add-on devices
Auxiliaries:
References
Tripping curve
Rated residual current
Series code
Rated current
L71N A C 025 030
Residual trip characteristic type
2-52 www.sassin.com
Mod
ular
Dev
ices
Residual Current Circuit Breakers with Overcurrent ProtectionSeries 3SL71N-40
2-53www.sassin.com
Modular Devices
Residual Current Circuit Breakers with Overcurrent Protection Series 3SL71N-40
In(A)
1P+N
6101620253240
Type AC Order code
Selection and ordering data
Type A
Type code Order code Type code I△n(mA)
30
100
300
Rated residual current Rated current
1P+N
1P+N
B Curve C Curve
6101620253240
6101620253240
1P+N
6101620253240
30
100
300
1P+N
1P+N
6101620253240
6101620253240
2/1 N
TEST
N1 /2
2/1 N
TEST
N1 /2
2/1 N
TEST
N1 /2
2/1 N
TEST
N1 /2
2/1 N
TEST
N1 /2
2/1 N
TEST
N1 /2
L71NC B06/030 20276L71NC B10/030 20277L71NC B16/030 20278L71NC B20/030 20279L71NC B25/030 20280L71NC B32/030 20281L71NC B40/030 20282
L71NC C06/030 20283L71NC C10/030 20284L71NC C16/030 20285L71NC C20/030 20286L71NC C25/030 20287L71NC C32/030 20288L71NC C40/030 20289
L71NA B06/030 20290L71NA B10/030 20291L71NA B16/030 20292L71NA B20/030 20293L71NA B25/030 20294L71NA B32/030 20295L71NA B40/030 20296
L71NA C06/030 20297L71NA C10/030 20298L71NA C16/030 20299L71NA C20/030 20300L71NA C25/030 20301L71NA C32/030 20302L71NA C40/030 20303
L71NC B06/100 20304L71NC B10/100 20305L71NC B16/100 20306L71NC B20/100 20307L71NC B25/100 20308L71NC B32/100 20309L71NC B40/100 20310
L71NC C06/100 20311L71NC C10/100 20312L71NC C16/100 20313L71NC C20/100 20314L71NC C25/100 20315L71NC C32/100 20316L71NC C40/100 20317
L71NA B06/100 20318L71NA B10/100 20319L71NA B16/100 20320L71NA B20/100 20321L71NA B25/100 20322L71NA B32/100 20323L71NA B40/100 20324
L71NA C06/100 20325L71NA C10/100 20326L71NA C16/100 20327L71NA C20/100 20328L71NA C25/100 20329L71NA C32/100 20330L71NA C40/100 20331
L71NC B06/300 20332L71NC B10/300 20333L71NC B16/300 20334L71NC B20/300 20335L71NC B25/300 20336L71NC B32/300 20337L71NC B40/300 20338
L71NC C06/300 20339L71NC C10/300 20340L71NC C16/300 20341L71NC C20/300 20342L71NC C25/300 20343L71NC C32/300 20344L71NC C40/300 20345
L71NA B06/300 20346L71NA B10/300 20347L71NA B16/300 20348L71NA B20/300 20349L71NA B25/300 20350L71NA B32/300 20351L71NA B40/300 20352
L71NA C06/300 20353L71NA C10/300 20354L71NA C16/300 20355L71NA C20/300 20356L71NA C25/300 20357L71NA C32/300 20358L71NA C40/300 20359
Number of poles
2-54 www.sassin.com
Mod
ular
Dev
ices
Residual Current Circuit Breakers with Overcurrent ProtectionSeries 3SL71N-40
Outline and installation dimensions
unit in mm
Tripping curves
Types Both RCCBs and RCBOs are divided into types depending on the operating function:Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults
I n< 50/R, to provide protection again indirect contacts
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
Curve B Curve C
N
35.7±0.5
88.9
90
44.1±0.2
35±
0.5
45±
0.3
N
5.2
69.5±0.6
2-55www.sassin.com
Modular Devices
Residual Current Circuit Breakers with Overcurrent Protection Series 3SB71LN
Functions
Switching and isolation function Protection against overload and short-circuit currents protection against the effects of sinusoidal alternating earth fault currents protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults Used in residential building
Technical specifications
Rated insulation voltage Ui ( VAC): 500
Tripping characteristic: B, C, D Characteristic curve B (In): 3-5 Characteristic curve C (In): 5-10 Characteristic curve D (In): 10-14
2Finely stranded with end sleeve (mm ): 0.75-25 ): 2.5 (℃)
(℃)Altitude Max (meters): 2,000
Standard: IEC 61009-1 Approval: CE Type (wave form of the earth leakage sensed): AC, A Number of poles: 2, 3, 4 Rated current In (A): 6, 10, 16, 20, 25, 32, 40 Rated voltage Ue (V): 230/400 Rated Frequency Fn (Hz): 50/60Rated residual currents IΔn (mA): 30, 100, 300
Rated breaking capacity acc. to IEC61009 ultimate Icn (kA): 10 Rated breaking capacity acc.to IEC60947-2 ultimate Icu (kA): 10 Rated residual breaking capacity IΔm (kA): 6 Rated impulse withstand voltage (1.2/50) Uimp (kV): 8 Dielectric test voltage at ind. freq. for 1 min.(kV): 2.5 Surge current resistance (wave 8/20) (A): 3,000
Electrical life(times): 10,000 Mechanical life(times): 20,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded(mm ): 0.75-35 Terminal tightening torque(Ambient temperature : -25 ~ +45, max. 95 % humidity
Storage temperature : -40~ +75
N•m
Features
The combination of an RCCB and a miniature circuit breaker in a compact design for personnel, fire and line protection. Electromagnetic type, voltage independent. The MCB part protects lines against overload and short circuits and is available in characteristics B, C and D. The handle provides a clear indication of the contact position.
Instruction of type code
Add-on devices
Auxiliaries:
References
Additional components: page 65~66Accessories: page 114~116
Rated residual current
Series code
Rated current
B71LN C 2 B 25 030
Residual trip characteristic type
Tripping curve
Number of poles: 2, 3, 4
Residual Current Circuit Breakers with Overcurrent ProtectionSeries 3SB71LN
2-56 www.sassin.com
Mod
ular
Dev
ices
2Order code
Selection and ordering data
Type code 30
30
30
Rated residual current
I△n(mA)Rated
current In(A)
B Curve C Curve
100
100
100
300
300
300
Number of poles
A2
A1T
T
A1
A2
A2
A1T
Order code Type code Order code Type code D Curve
3
4
61016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
101620253240
B71LNC 2B06/030HB71LNC 2B10/030HB71LNC 2B16/030HB71LNC 2B20/030HB71LNC 2B25/030HB71LNC 2B32/030HB71LNC 2B40/030HB71LNC 2B06/100HB71LNC 2B10/100HB71LNC 2B16/100HB71LNC 2B20/100HB71LNC 2B25/100HB71LNC 2B32/100HB71LNC 2B40/100HB71LNC 2B06/300HB71LNC 2B10/300HB71LNC 2B16/300HB71LNC 2B20/300HB71LNC 2B25/300HB71LNC 2B32/300HB71LNC 2B40/300HB71LNC 3B06/030HB71LNC 3B10/030HB71LNC 3B16/030HB71LNC 3B20/030HB71LNC 3B25/030HB71LNC 3B32/030HB71LNC 3B40/030HB71LNC 3B06/100HB71LNC 3B10/100HB71LNC 3B16/100HB71LNC 3B20/100HB71LNC 3B25/100HB71LNC 3B32/100HB71LNC 3B40/100HB71LNC 3B06/300HB71LNC 3B10/300HB71LNC 3B16/300HB71LNC 3B20/300HB71LNC 3B25/300HB71LNC 3B32/300HB71LNC 3B40/300HB71LNC 4B06/030HB71LNC 4B10/030HB71LNC 4B16/030HB71LNC 4B20/030HB71LNC 4B25/030HB71LNC 4B32/030HB71LNC 4B40/030HB71LNC 4B06/100HB71LNC 4B10/100HB71LNC 4B16/100HB71LNC 4B20/100HB71LNC 4B25/100HB71LNC 4B32/100HB71LNC 4B40/100HB71LNC 4B06/300HB71LNC 4B10/300HB71LNC 4B16/300HB71LNC 4B20/300HB71LNC 4B25/300HB71LNC 4B32/300HB71LNC 4B40/300H
169471694816949169501695116952169531701017011170121701317014170151701617073170741707517076170771707817079169541695516956169571695816959169601701717018170191702017021170221702317080170811708217083170841708517086169611696216963169641696516966169671702417025170261702717028170291703017087170881708917090170911709217093
B71LNC 2C06/030HB71LNC 2C10/030HB71LNC 2C16/030HB71LNC 2C20/030HB71LNC 2C25/030HB71LNC 2C32/030HB71LNC 2C40/030HB71LNC 2C06/100HB71LNC 2C10/100HB71LNC 2C16/100HB71LNC 2C20/100HB71LNC 2C25/100HB71LNC 2C32/100HB71LNC 2C40/100HB71LNC 2C06/300HB71LNC 2C10/300HB71LNC 2C16/300HB71LNC 2C20/300HB71LNC 2C25/300HB71LNC 2C32/300HB71LNC 2C40/300HB71LNC 3C06/030HB71LNC 3C10/030HB71LNC 3C16/030HB71LNC 3C20/030HB71LNC 3C25/030HB71LNC 3C32/030HB71LNC 3C40/030HB71LNC 3C06/100HB71LNC 3C10/100HB71LNC 3C16/100HB71LNC 3C20/100HB71LNC 3C25/100HB71LNC 3C32/100HB71LNC 3C40/100HB71LNC 3C06/300HB71LNC 3C10/300HB71LNC 3C16/300HB71LNC 3C20/300HB71LNC 3C25/300HB71LNC 3C32/300HB71LNC 3C40/300HB71LNC 4C06/030HB71LNC 4C10/030HB71LNC 4C16/030HB71LNC 4C20/030HB71LNC 4C25/030HB71LNC 4C32/030HB71LNC 4C40/030HB71LNC 4C06/100HB71LNC 4C10/100HB71LNC 4C16/100HB71LNC 4C20/100HB71LNC 4C25/100HB71LNC 4C32/100HB71LNC 4C40/100HB71LNC 4C06/300HB71LNC 4C10/300HB71LNC 4C16/300HB71LNC 4C20/300HB71LNC 4C25/300HB71LNC 4C32/300HB71LNC 4C40/300H
169681696916970169711697216973169741703117032170331703417035170361703717094170951709617097170981709917100169751697616977169781697916980169811703817039170401704117042170431704417101171021710317104171051710617107169821698316984169851698616987169881704517046170471704817049170501705117108171091711017111171121711317114
B71LNC 2D06/030HB71LNC 2D10/030HB71LNC 2D16/030HB71LNC 2D20/030HB71LNC 2D25/030HB71LNC 2D32/030HB71LNC 2D40/030HB71LNC 2D06/100HB71LNC 2D10/100HB71LNC 2D16/100HB71LNC 2D20/100HB71LNC 2D25/100HB71LNC 2D32/100HB71LNC 2D40/100HB71LNC 2D06/300HB71LNC 2D10/300HB71LNC 2D16/300HB71LNC 2D20/300HB71LNC 2D25/300HB71LNC 2D32/300HB71LNC 2D40/300HB71LNC 3D06/030HB71LNC 3D10/030HB71LNC 3D16/030HB71LNC 3D20/030HB71LNC 3D25/030HB71LNC 3D32/030HB71LNC 3D40/030HB71LNC 3D06/100HB71LNC 3D10/100HB71LNC 3D16/100HB71LNC 3D20/100HB71LNC 3D25/100HB71LNC 3D32/100HB71LNC 3D40/100HB71LNC 3D06/300HB71LNC 3D10/300HB71LNC 3D16/300HB71LNC 3D20/300HB71LNC 3D25/300HB71LNC 3D32/300HB71LNC 3D40/300HB71LNC 4D06/030HB71LNC 4D10/030HB71LNC 4D16/030HB71LNC 4D20/030HB71LNC 4D25/030HB71LNC 4D32/030HB71LNC 4D40/030HB71LNC 4D06/100HB71LNC 4D10/100HB71LNC 4D16/100HB71LNC 4D20/100HB71LNC 4D25/100HB71LNC 4D32/100HB71LNC 4D40/100HB71LNC 4D06/300HB71LNC 4D10/300HB71LNC 4D16/300HB71LNC 4D20/300HB71LNC 4D25/300HB71LNC 4D32/300HB71LNC 4D40/300H
169891699016991169921699316994169951705217053170541705517056170571705817115171161711717118171191712017121169961699716998169991700017001170021705917060170611706217063170641706517122171231712417125171261712717128
170031700417194171951719617197171981706617067172571725817259172601726117129171301732017321173221732317324
Type AC
2-57www.sassin.com
Residual Current Circuit Breakers with Overcurrent Protection Series 3SB71LN
Modular Devices
Selection and ordering data
2Order code Type code
30
30
30
Rated residual current
I△n(mA)Rated
current In(A)
B Curve C Curve
100
100
100
300
300
300
Number of poles
A2
A1T
T
A1
A2
A2
A1T
Order code Type code Order code Type code D Curve
3
4
61016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
1016202532406
101620253240
Type ACB71LNA 2B06/030HB71LNA 2B10/030HB71LNA 2B16/030HB71LNA 2B20/030HB71LNA 2B25/030H
B71LNA 2B40/030H
B71LNA 2C06/030HB71LNA 2C10/030HB71LNA 2C16/030HB71LNA 2C20/030HB71LNA 2C25/030H
B71LNA 2C40/030H
B71LNA 2D06/030HB71LNA 2D10/030HB71LNA 2D16/030HB71LNA 2D20/030HB71LNA 2D25/030H
B71LNA 2D40/030HB71LNA 2B06/100HB71LNA 2B10/100HB71LNA 2B16/100HB71LNA 2B20/100HB71LNA 2B25/100HB71LNA 2B32/100H
B71LNA 2C06/100HB71LNA 2C10/100HB71LNA 2C16/100HB71LNA 2C20/100HB71LNA 2C25/100HB71LNA 2C32/100H
B71LNA 2D06/100HB71LNA 2D10/100HB71LNA 2D16/100HB71LNA 2D20/100HB71LNA 2D25/100HB71LNA 2D32/100H
B71LNA 2B06/300HB71LNA 2B10/300HB71LNA 2B16/300HB71LNA 2B20/300HB71LNA 2B25/300HB71LNA 2B32/300H
B71LNA 2C06/300HB71LNA 2C10/300HB71LNA 2C16/300HB71LNA 2C20/300HB71LNA 2C25/300HB71LNA 2C32/300H
B71LNA 2D06/300HB71LNA 2D10/300HB71LNA 2D16/300HB71LNA 2D20/300HB71LNA 2D25/300HB71LNA 2D32/300H
B71LNA 3B06/030HB71LNA 3B10/030HB71LNA 3B16/030HB71LNA 3B20/030HB71LNA 3B25/030HB71LNA 3B32/030H
B71LNA 3C06/030HB71LNA 3C10/030HB71LNA 3C16/030HB71LNA 3C20/030HB71LNA 3C25/030HB71LNA 3C32/030H
B71LNA 3D06/030HB71LNA 3D10/030HB71LNA 3D16/030HB71LNA 3D20/030HB71LNA 3D25/030HB71LNA 3D32/030H
B71LNA 3B06/100HB71LNA 3B10/100HB71LNA 3B16/100HB71LNA 3B20/100HB71LNA 3B25/100H
B71LNA 3B40/100H
B71LNA 3C06/100HB71LNA 3C10/100HB71LNA 3C16/100HB71LNA 3C20/100HB71LNA 3C25/100H
B71LNA 3C40/100H
B71LNA 3D06/100HB71LNA 3D10/100HB71LNA 3D16/100HB71LNA 3D20/100HB71LNA 3D25/100H
B71LNA 3D40/100HB71LNA 3B06/300HB71LNA 3B10/300HB71LNA 3B16/300HB71LNA 3B20/300HB71LNA 3B25/300H
B71LNA 3B40/300H
B71LNA 3C06/300HB71LNA 3C10/300HB71LNA 3C16/300HB71LNA 3C20/300HB71LNA 3C25/300H
B71LNA 3C40/300H
B71LNA 3D06/300HB71LNA 3D10/300HB71LNA 3D16/300HB71LNA 3D20/300HB71LNA 3D25/300H
B71LNA 3D40/300HB71LNA 4B06/030HB71LNA 4B10/030HB71LNA 4B16/030HB71LNA 4B20/030HB71LNA 4B25/030H
B71LNA 4B40/030H
B71LNA 4C06/030HB71LNA 4C10/030HB71LNA 4C16/030HB71LNA 4C20/030HB71LNA 4C25/030H
B71LNA 4C40/030H
B71LNA 4D06/030HB71LNA 4D10/030HB71LNA 4D16/030HB71LNA 4D20/030HB71LNA 4D25/030H
B71LNA 4D40/030HB71LNA 4B06/100HB71LNA 4B10/100HB71LNA 4B16/100HB71LNA 4B20/100HB71LNA 4B25/100H
B71LNA 4B40/100H
B71LNA 4C06/100HB71LNA 4C10/100HB71LNA 4C16/100HB71LNA 4C20/100HB71LNA 4C25/100H
B71LNA 4C40/100H
B71LNA 4D06/100HB71LNA 4D10/100HB71LNA 4D16/100HB71LNA 4D20/100HB71LNA 4D25/100H
B71LNA 4D40/100HB71LNA 4B06/300HB71LNA 4B10/300HB71LNA 4B16/300HB71LNA 4B20/300HB71LNA 4B25/300H
B71LNA 4B40/300H
B71LNA 4C06/300HB71LNA 4C10/300HB71LNA 4C16/300HB71LNA 4C20/300HB71LNA 4C25/300H
B71LNA 4C40/300H
B71LNA 4D06/300HB71LNA 4D10/300HB71LNA 4D16/300HB71LNA 4D20/300HB71LNA 4D25/300H
B71LNA 4D40/300H
1713617137171381713917140
17142
171431714417145171461714717148
1715017151171521715317154
17156
171991720017201172021720317204
1720617207172081720917210
17212
1721317214172151721617217
17219
172621726317264172651726617267
1726917270172711727217273
17275
1727617277172781727917280
17282
1717117172171731717417175
171771723417235172361723717238
172401729717298172991730017301
17303
171641716517166171671716817169
1722717228172291723017231
172331729017291172921729317294
17296
1715717158171591716017161
17163172201722117222172231722417225
172831728417285172861728717288
1719217193171941719517196
171981725517256172571725817259
172611731817319173201732117322
17324
171851718617187171881718917190
1724817249172501725117252
172541731117312173131731417315
17317
1717817179171801718117182
17184172411724217243172441724517246
173041730517306173071730817309
B71LNA 4B32/300H B71LNA 4C32/300H B71LNA 4D32/300H17281 173023 17323
B71LNA 4B32/100H B71LNA 4C32/100H B71LNA 4D32/100H17218 17239 17260
B71LNA 4B32/030H B71LNA 4C32/030H B71LNA 4D32/030H17155 17176 17197
B71LNA 3B32/300H B71LNA 3C32/300H B71LNA 3D32/300H17274 17295 17316
B71LNA 3B32/100H B71LNA 3C32/100H B71LNA 3D32/100H17211 17232 17253
B71LNA 3B40/030H B71LNA 3C40/030H B71LNA 3D40/030H17149 17170 17191
B71LNA 2B40/300H B71LNA 2C40/300H B71LNA 2D40/300H17268 17289 17310
B71LNA 2B32/030H B71LNA 2C32/030H B71LNA 2D32/030H17141 17162 17183
B71LNA 2B40/100H B71LNA 2C40/100H B71LNA 2D40/100H17205 17226 17247
Residual Current Circuit Breakers with Overcurrent ProtectionSeries 3SB71LN
2-58 www.sassin.com
Mod
ular
Dev
ices
Outline and installation dimensions
unit in mm
Tripping curves
Types Both RCCBs and RCBOs are divided into types depending on the operating function:Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulation faults
I n< 50/R, to provide protection again indirect contacts
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
Curve B Curve C
0.004
B
0.01
0.020.04
0.10.20.40.6
1246
10204060
100200400600
1000200040006000
10000
1.5 2 3 4 6 8 10 15 20 30 400.004
0.10.20.40.6
1246
10204060
100200400600
1000200040006000
10000
1.5 2 3 4 6 8 10 15 20 30 40
0.01
0.020.04
C
1.13 1.45 1.13 1.45
50.6±0.3
78max
90m
ax(P
akag
e out
line d
imen
sion)
45±0.3 35
92m
ax(in
stalla
tion
dim
ensio
ns)
90 0-1.6
72
542
3
4
Action time(s) Action time(s)
0.004
0.1
0.20.40.6
1
246
10204060
100
200400600
1000200040006000
10000
1.13 1.45 1.5 2 3 4 6 8 10 15 20 30 40
0.01
0.020.04
D
Action time(s)
Curve D
0-1.2
0-0.8
Modular Devices
2-59www.sassin.com
Series 3SB72LE-25
3SB72LE-25 RCBO (Residual current circuit breakers with over-current protection), is newly developed by SASSIN, which applies to circuit of AC50/60Hz, rated voltage to 230V, and rated current up to 25A. 3SB72LE-25 series RCBO are widely used in residual building with the function of switching and isolating, overload protection, short-circuit protection and protection against the effects of sinusoidal alternating earth fault currents.
Standard: IEC61009-1Number of poles (P): 1+NRated current In (A): 6, 10, 16, 20, 25Rated frequency (Hz): 50/60Rated operating voltage Ue (V): AC230Rated insulation voltage Ui (V): 500Rated residual operating current IΔn (mA): 30Rated breaking capacity Icn (kA): 6Rated residual breaking capacity IΔm (kA): 4.5Electrical life: 4000(240times/hour)Agreed non-tripping current: 1.13In (h): 1Agreed tripping current: 1.45In (h): 12.55In (s): 1<t<60Tripping characteristic type: CInstantaneous non-tripping current: t≤0.1s: 5InInstantaneous tripping current: t<0.1s: 10InDegree of protection: IP20Energy limiting class: 3Class of pollution: 2Mounting class: Ⅱ, ⅢInstallation way: With the mounting rail of TH35-7.5 steelConnecting wire(Min/Max)(mm2): 1/16Terminal tightening torque (N·m): 1.8Upper /lower incoming line: upper incoming lineInsulation function: yes
Application
Technical specifications
Instruction of type code
Selection and ordering data
610162025
B72LE C06/030B72LE C10/030B72LE C16/030B72LE C20/030B72LE C25/030
1533115332153331533415335
Type code Order code1+N
Number of pole
(P)
Rated current
(A)
Series code
Rated residual current(mA): 30
B72LE C 06 030 /
Outline and installation dimensions
unit in mm
T
1 N
2 N
45
±0
.3
35
50.3±0.3
78max
10
1m
ax(P
aka
ge o
utl
ine d
ime
nsio
n)
10
3m
ax(I
nsta
lla
tio
n d
ime
nsio
ns)
18+0-0.3
Tripping curve: C
Residual Current Circuit Breakers with Overcurrent Protection
Rated current (A): 6, 10, 16, 20, 25
New product to be expected
Rated residual CurrentIΔn(mA)
30
2-60 www.sassin.com
Residual Current Circuit Breakers with Overcurrent ProtectionSeries 3SB71L-50
Mod
ular
Dev
ices
Functions
Switching and isolation function. Protection against overload and short-circuit currents. protection against the effects of sinusoidal alternating earth fault currents protection against indirect contacts and additional protection against direct contacts. Protection against fire hazard caused by insulation faults. Used in residential building and distribution boards.
Instruction of type code
Technical specifications Standard: IEC 61009-1 Approval: CE Type (wave form of the earth leakage sensed): AC Number of poles: 1+N (1 module) Rated current In (A): 6, 10, 16, 20, 25, 32, 40, 50 Rated voltage Ue (V): 230 Rated insulation voltage Ui (VAC): 500 Rated Frequency Fn (Hz ): 50/60 Rated residual currents IΔn (mA) 30 Rated breaking capacity acc.to IEC61009-1 ultimate Icn (kA): 10 Rated breaking capacity acc.to IEC60947-2 ultimate Icu (kA): 10 Rated residual breaking capacity IΔm (kA):10 Rated impulse withstand voltage (1.2/50) Uimp (kV): 4 Dielectric test voltage at ind. freq. for 1 min.(kV): 2 Surge current resistance (wave 8/20) (A): 3,000 Tripping characteristic: B, C Characteristic B ( In): 3-5 Characteristic C ( In): 5-10 Electrical life (times): 4,000 Mechanical life (times): 10,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded ( mm ): 0.75-352 Finely stranded with end sleeve ( mm ): 0.75-25
Terminals Terminal tightening torque ( ): 2.5
Ambient temperature (℃): -5 ~ +45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude( meters): Max 2,000
N•m
Features
The combination of an RCCB and a miniature circuit breaker in a compact design. The MCB part protects lines against overload and short circuits and is available in characteristics curve B and C. Electronic Type,voltage dependent The handle provides a clear indication of the contact position. The earth reference cable ensures protection against earth leakage in case of loss of supply neutral.
Rated residual current(mA):30
Series code
Rated current(A): 6,10,16,20,25,32,40,50
B71L C 06 030
Tripping curve:B,C
2-61www.sassin.com
Modular Devices
Residual Current Circuit Breakers with Overcurrent Protection Series 3SB71L-50
In(A)
1P+N
610162025324050
Order code
Selection and ordering data
Type code Order code Type code I△n(mA)
30
Rated residual current Rated current B Curve C Curve
N
NN
OUT OUTN L FE
B71L B06/030 23589B71L B10/030 23590B71L B16/030 23591B71L B20/030 23592B71L B25/030 23593B71L B32/030 23594B71L B40/030 23595B71L B50/030 23596
B71L C06/030 23597B71L C10/030 23598B71L C16/030 23599B71L C20/030 23600B71L C25/030 23601B71L C32/030 23602B71L C40/030 23603B71L C50/030 23604
Tripping curves
Types Both RCCBs and RCBOs are divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.
20000
10000
2H
2000
1000
500
200
100
50
20
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
t (s)
0.5 1 2 3 4 5 7 10 14 20 30 50 70 100 200 I/In
20000
100002H
2000
1000
500
200
100
50
20
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
0.002
0.001
t (s)
2
5
10
0.5 1 2 3 4 5 7 10 14 20 30 50 70 100 200 I/In
Curve B Curve C
Number of poles
Outline and installation dimensions
unit in mm
18
130
35 45
7871
44
Type AC
2-62 www.sassin.com
Mod
ular
Dev
ices
Instruction of type code
Functions
Assembly on side with MCBsProtection against the effects of sinusoidal alternating
earth fault currentsProtection against indirect contacts and additional
protection against direct contacts
Technical specifications
Δ
Standard: IEC 61009-1 AC, A Number of poles: 2, 3, 4 Rated current In (A): 40, 63
Rated voltage Ue (V AC): 230/400 Rated insulation voltage Ui (VAC): 500 Rated Frequency Fn (Hz): 50/60 Rated residual currents (mA) : I n= 30,100, 300 Rated breaking capacity (Icn) : Icn of the associated MCB Rated residual breaking capacity lm: Icn of the associated MCB Electrical life (times): 4,000 Mechanical life (times): 10,000 Degree of protection: IP20, with connected conductors Mounting position: Any Conductor cross-sections
2 Solid and stranded (mm ): 0.75-35 2 Finely stranded with end sleeve (mm ): 0.75-25
Terminals Terminal tightening torque(N•m): 2.8 Ambient temperature (℃): -25 ~ 45, max. 95 % humidity Storage temperature (℃): -40 ~ +75 Altitude Max (meters ): 2,000
Approval: CEType (wave form of the earth leakage sensed):
Features
Electronic Type,voltage dependent and Electromagnetic type, voltage independent.for customer's option Assembly on side with MCBs 3SB71 series.
Rated residual current
Series code
B71LB 40 2 E A 030
Frame current
M: Electromagnetic type E:Electronic type
Number of poles: 2, 3, 4
Residual trip characteristic type
RCD BlocksSeries 3SB71LB
2-63www.sassin.com
Modular Devices
RCD BlocksSeries 3SB71LB
Selection and ordering data
In(A)40
63
Type AC
Order code
3
Packing unit 1
Packing unit 1
Packing unit 1
4
Type A
Type code Order code Type code I n(mA)△
3010030030100300
40
63
3010030030100300
40
63
3010030030100300
Electromagnetic typeRated residual current Rated current
19502B71LB40 2MC03019503B71LB40 2MC10019504B71LB40 2MC30019505B71LB63 2MC03019506B71LB63 2MC10019507B71LB63 2MC300
19508B71LB40 2MA03019509B71LB40 2MA10019510B71LB40 2MA30019511B71LB63 2MA03019512B71LB63 2MA10019513B71LB63 2MA300
19514B71LB40 3MC03019515B71LB40 3MC10019516B71LB40 3MC30019517B71LB63 3MC03019518B71LB63 3MC10019519B71LB63 3MC300
195201952119522195231952419525
B71LB40 3MA030B71LB40 3MA100B71LB40 3MA300B71LB63 3MA030B71LB63 3MA100B71LB63 3MA300
19526B71LB40 4MC03019527B71LB40 4MC10019528B71LB40 4MC30019529B71LB63 4MC03019530B71LB63 4MC10019531B71LB63 4MC300
19532B71LB40 4MA03019533B71LB40 4MA10019534B71LB40 4MA30019535B71LB63 4MA03019536B71LB63 4MA10019537B71LB63 4MA300
In(A)
2
40
63
3
Packing unit 1
Packing unit 1
Packing unit 1
4
Type A
Electronic TypeI△n(mA)
3010030030100300
40
63
3010030030100300
40
63
3010030030100300
Rated residual current Rated current Order code Type code
19538B71LB40 2EA03019539B71LB40 2EA10019540B71LB40 2EA30019541B71LB63 2EA03019542B71LB63 2EA10019543B71LB63 2EA300
195441954519546195471954819549
B71LB40 3EA030B71LB40 3EA100B71LB40 3EA300B71LB63 3EA030B71LB63 3EA100B71LB63 3EA300
19550B71LB40 4EA03019551B71LB40 4EA10019552B71LB40 4EA30019553B71LB63 4EA03019554B71LB63 4EA10019555B71LB63 4EA300
Number of poles
2
Number of poles
Mod
ular
Dev
ices
RCD BlocksSeries 3SB71LB
2-64 www.sassin.com
a
10000
3SB71LB-63
30mA
230V~~ ~
IEC61009-1GB16917.1
400V~
30mA
3SB71LB-63
10000
a a
10000
3SB71LB-63
30mA
400V~~
0 OFF
1 ON
143
100
100
12571.6
10045
44
70.5
6.5
35.5
Outline and installation dimensions
unit in mm
IEC61009-1GB16917.1
0 OFF
1 ON
0 OFF
1 ON
IEC61009-1GB16917.1
Types
Both RCCBs and RCBOs are divided into types depending on the operating function: Type AC : For which tripping is ensured for residual sinusoidal alternating currents, whether suddenly applied or slowly rising. Type A : For which tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
Tripping sensitivity data
RCD with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact.RCD with a rated residual current of maximum 300 mA are used as preventative fire protection in case of insulationfaults
I n< 50/R, to provide protection again indirect contacts
RCD with a rated residual current of 100mA co-ordinated with the earth system according to the formula △
7
1 2
3
56
4
Max.
4.5 Nm
Assembly diagram
Additional Components (for MCB Series:3SB71-63,3SB71-125,3SB71Z,RCBO Series: 3SL71N-40,3SB71LN)
Modular Devices
2-65www.sassin.com
Functions
3SB71C Auxiliary contact: indication of the position of MCB and RCD 3SB71J Auxiliary alarm: signaling of status making or breaking of MCB and RCD through Alarm 3SB71CC/CJ Auxiliary contact & alarm: combination of auxilary contact and alarm 3SB71Q Under voltage release: protection of the load in the event of a voltage drop (between 70% and 35% of its rated value) 3SB71F Shunt release :remote opening of the device when a voltage is applied Suitable for MCB Series:3SB71-63,3SB71-125,3SB71Z,RCBO Series: 3SL71N-40, 3SB71LN
Technical specifications
Standard: IEC60947-2 Rated insulation voltage Vi ( : 500 Rated frequency (Hz):50/60 Utilization category: AC14 Mechanical life (times): 4,000 Conductor cross-sections
2 Solid and stranded (mm ) : 2.5 Ambient temperature ( : -5 ~ +40, max. 95 % humidity Storage temperature ( : -40 ~ +75
VAC)
℃)℃)
Features
Combination of auxiliary elements with MCB Series: 3SB71-63,3SB71-125,3SB71Z,RCBO Series: 3SL71N-40, 3SB71LN
3SB71F
3SB71CC/R
3SB71CJ/CCR
3SB71Q/R
3SB71LB
3SB71F
3SB71CC/L
3SB71CJ/CCL
3SB71Q/L
2-66 www.sassin.com
Mod
ular
Dev
ices
Additional Components (for MCB Series:3SB71-63,3SB71-125,3SB71Z,RCBO Series: 3SL71N-40,3SB71LN)
55555555555555
12V24V48V
127V DC230V DC127V AC230V AC
12V24V48V
127V DC230V DC127V AC230V AC
1212121212121212121212121212
RRRRRRRLLLLLLL
0.50.50.50.50.50.50.50.50.50.50.50.50.50.5
20002000200020002000200020002000200020002000200020002000
AC14AC14AC14AC14AC14AC14AC14AC14AC14AC14AC14AC14AC14AC14
-
-
-
-
-
-
-
-
-
-
-
-
-
-
160781607916080160811608216083160841608516086160871608816089160901609122.5mm
22.5mm
22.5mm22.5mm22.5mm22.5mm22.5mm22.5mm
22.5mm
22.5mm22.5mm22.5mm22.5mm22.5mm≥4000
≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000≥4000
Selection and ordering data
U <
D1 D2
0.3s 0
55
55
55
AC230AC230
A 230AC230
C
A 230AC230
C
-
-
-
-
-
-
1212
1212
1212
RL
RL
RL
0.50.5
0.50.5
0.50.5
≥4000≥4000
-
-
-
-
-
-
20002000
20002000
20002000
22.5mm AC14AC14
AC14AC14
AC14AC14
2027120272
2027320274
1046610477
5
5
5
5
12
12
12
12
R
R
L
L
0.5
0.5
0.5
0.5
4000
4000
4000
4000
22.5mm
22.5mm
22.5mm
22.5mm
AC14
AC14
AC14
AC14
17726
20275
26330
26329
Rated current
(A)
Voltage(V)
CoilVoltage
V AC
PackingUnit
pc
InstallationSide
TorqueN/m
MechanicLife
times
ElectricLife
times
Diselectric
Strength
WireSquare Application Order
Code
14 12 C2 C1
3SB71F Shunt release
3SB71Q Under voltage release
3SB71CJ/CC Auxiliary contact & Auxiliary alarm contact
3SB71J Auxiliary alarm contact
3SB71CC Auxiliary contact
≥4000≥4000
≥4000≥4000
≥4000
≥4000
≥4000
≥4000
AC24-60DC16-48
AC110-415DC110-125
AC24-60DC16-48
AC110-415DC110-125
22.5mm
22.5mm22.5mm
22.5mm22.5mm
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2-67www.sassin.com
Modular Devices
Functions
OF and OFN Auxiliary contact: indication of the position of the device’s contacts SD Auxiliary alarm: signaling of the position of the device’s contacts by alarm only after the automatic release of the MCBs and RCDs due to an overload or a short-circuit S2 Shunt Release: remote opening of the device when a voltage is applied U2+O2 Under voltage release: protection of the load in the event of a voltage drop (between 70% and 35% of its rated value) Suitable for MCB series 3SB5,3SB52, 3SB1-63N, 3SB1-125
Technical specifications
Standard IEC60947-5-1 Rated insulation voltage ( : 500 Rated frequency (Hz): 50/60 Rated impulse withstand voltage (kA) : 5 Utilization category: AC14, AC15 Mechanical life (times): 10,000 Conductor cross-sections
2 Solid and stranded (mm ): 2-2.5 Ambient temperature ( : -5 ~ +40, max. 95 % humidity Storage temperature ( : -40 ~ +75
:VAC)
℃)℃)
SD Auxiliary alarm
S2 Shunt release
A1
A2
Uvo
1 3
2 4
Type code Order code
Ratedcurrent
(A) 6 SD 10472
Type code Order code
Rated voltage
(V) 230 AC400 AC24 DC48 DC
S223AS240AS224DS248D
10476104771047810479
U2 & O2 Under voltage / Over voltage release
Type code Order code
Rated voltage
(V) UO23A 10480230 AC
OF Auxiliary contact
Type code Order codeOF
Ratedcurrent
(A) 6 10468
Selection and ordering data
OFN Auxiliary contact
Type code Order codeOFN
Ratedcurrent
(A) 6 34355
Application :3SB52, 3SB1-125
Application :3SB5,3SB1-63N
Additional Components (for MCB Series: 3SB5,3SB52,3SB1-63N,3SB1-125)
400 AC24 DC48 DC
UO40AUO24DUO48D
104811048210483
Outline and installation dimensions
unit in mm
45
44
86
35
71
5
6
7
8
90
18
36
54
72
Functions
Making and breaking under load conditionProviding safety isolation for terminal distribution systemUsed in residential building, non-residential building
Technical specifications
Standard: IEC 60947-3Approval: CERated current In (A): 32, 63, 100, 125Rated voltage Un (VAC): 230/400Rated insulation voltage (VAC): 500Number of poles: 1, 2, 3, 4Rated short-time withstand current 20 In: 1SDegree of protection: IP20, with connected conductorsElectrical life (times): 10,000Mechanical life (times): 20,000Fire resistance according to UL 94:V0Mounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35 Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque (N ): 2-2.5Ambient temperature (℃): -25~+45, max. 95% humidityStorage temperature (℃): -40~+75Altitude(meters): Max. 2,000
•m
Features
The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationBased on the technology of MCB series 3SB71, similar designto series 3SB71Matched with series 3SB71
Reference
Accessories: page 84-86
Instruction of type code
Number of poles: 1, 2, 3, 4
Series code
Rated current(A): 32, 63, 100 , 125
B71G 2 032
Pack.
Selection and ordering data
1Type code Order code
12121212
32 B71G 1032 2289963
100125
B71G 1063B71G 1100B71G 1125
229002290138876
1
2
2 6666
32 B71G 203263
100125
B71G 2063B71G 2100B71G 2125
22902229032290438877
4444
3 32 B71G 303263
100125
B71G 3063B71G 3100B71G 3125
22905229062290738878
1 3 5 7
2 4 6 8
1 3 5
2 4 6
1 3
2 4
Number of poles
Rated current
(A)
333
4 32 B71G 403263
100B71G 4063B71G 4100
229082290922910
3125 B71G 4125 38879
2-68 www.sassin.com
Mod
ular
Dev
ices
Main SwitchesSeries 3SB71G
2-69www.sassin.com
Modular Devices
Main SwitchesSeries 3SG6
45
50
84
35
77
Pack.1212121212666664444433333
Selection and ordering data
1 25406380
10025406380
10025406380
10025406380
100
G6 1025G6 1040G6 1063G6 1080G6 1100G6 2025G6 2040G6 2063G6 2080G6 2100G6 3025G6 3040G6 3063G6 3080G6 3100G6 4025G6 4040G6 4063G6 4080G6 4100
39949 39950 39951 39952 39953 39954 39955 39956 39957 39958 39959 39960 39961 39962 39963 39964 39965 39966 39967 39968
Type code Order code
1
2
2
3
4
1 3 5 7
2 4 6 8
1 3 5
2 4 6
1 3
2 4
Number of poles
Functions
Making and breaking under load conditionProviding safety isolation for terminal distribution systemUsed in residential building, non-residential building
Technical specifications
Standard: IEC 60947-3Approval: CERated current In (A): 25, 40, 63, 80, 100Rated voltage Un (VAC): 1P: 230/400; 2-4P: 400Rated insulation voltage (VAC): 500Number of poles (P): 1, 2, 3, 4Rated short-time withstand current 20 In: 1SDegree of protection: IP20, with connected conductorsElectrical endurance (Cycles): 4,000Mechanical endurance (Cycles): 10,000Fire resistance according to IEC 60695: 960℃ Mounting position: AnyBusbar Connection: Pin typeConductor cross-sectionsSolid and stranded (mm²): 1-35Finely stranded with end sleeve (mm²): 1-25Terminal tightening torque (N ): 2.5Ambient temperature (℃): -5~+45, max. 95% humidityAltitude(meters): Max. 2,000
• m
Features
Adequate printing of all data on the front provides long term identificationMatched with series 3SB6
Rated current
(A)
Instruction of type code
Number of poles(P): 1, 2, 3, 4
Series code
Rated current(A): 25, 40, 63, 80, 100
G6 2 025
Outline and installation dimensions
18
36
54
72
unit in mm
www.sassin.com
Main SwitchesSeries 3SB1G
2-70
Mod
ular
Dev
ices
Functions
Making and breaking under load conditionProviding safety isolation for terminal distribution system.Used in residential building, non-residential building.
Technical specifications
Standard: IEC 60947-3Approval: CERated current Ie (A): 40, 63, 100Rated voltage Ui (VAC): 230/400Rated insulation voltage Vi(VAC): 500Number of poles: 1, 2, 3, 4Degree of protection: IP20, with connected conductorsElectrical life (times): 1,500Mechanical life (times): 8,500Rated short-time withstand current 12 Ie: 1 SMounting position: AnyConductor cross-sectionsSolid and stranded (mm²): 0.75-35Finely stranded with end sleeve (mm²): 0.75-25 Terminal tightening torque (N·m): 2.5Ambient temperature (℃): -25~+45, max. 95% humidityStorage temperature (℃): -40~+75Altitude Max.(meters): 2,000
Instruction of type code
Selection and ordering data
Pack.40 B1G 1040 23605 1263 12
100 12
Type code Order code
B1G 1063B1G 1100
2360623607
40 B1G 3040 463 4
100 4B1G 3063B1G 3100
23611
40 B1G 4040
23612
363 3
100 3B1G 4063B1G 4100
23613
236142361523616
1 3 5 7
2 4 6 8
40 B1G 2040 663 6
100 6B1G 2063B1G 2100
236082360923610
1 3 5
2 4 6
1
2
1 3
2 4
The handle provides a clear indication of the contact positionAdequate printing of all data on the front provides long-term identificationBased the technology of MCB series 3SB1-63N, similar design to series 3SB1-63N.Matched with series MCB 3SB5, 3SB52, 3SB1-63NFull sets of accessories
Features
ReferenceAccessories: page 108~110
1
2
3
4
Number of poles
Rated current (A)
Number of poles: 1, 2, 3, 4
Series code
Rated current (A): 40, 63, 100
B1G 2 032
Outline and installation dimensions
unit in mm
5
6
7
8
45
43.8
76
35
70.1
80
18
36
54
72
230/400
Pushbuttons and Indicator Lamps 3SB71PD, 3SB1DSeries
2-71www.sassin.com
Modular Devices
Functions
Technical specifications
Standard: IEC 60947-5-1Approval: CERated voltage Ue (V): 230Rated current In (A): 6Conventional glowing current (A): 16 Frequency (Hz): 50/60Modules (18mm): 1Utilization category: AC14, DC13Degree of protection: IP20, with connected conductorsConductor cross-sectionsSolid and stranded (mm²): 1-10Finely stranded with end sleeve (mm²): 1-4Terminal tightening torque ( ): 0.5Ambient temperature (℃): -5~+40, max. 95% humidityStorage temperature (℃): -40~+75Connection Capacity (mm²): 1-16
N·m
The pushbuttons are used for remote control in every kind of electric installation.The indicator lamps signal any event in every kind of electric installation.3SB71P,3SB71D,3SB71PD may match with MCB series 3SB71-633SB1D may match with MCB series 3SB5,3SB52,3SB1-63N
Outline and installation dimensions
unit in mm
3SB71P/3SB71D/3SB71PD 3SB1D
70.9max
50.3
69max
18
91
.5m
ax
35
±0
.5
45
75
273
5
3SB71PD/P/D
3SB1D
2-72 www.sassin.com
Mod
ular
Dev
ices
Pushbuttons and Indicator LampsSeries 3SB71PD, 3SB1D
Selection and ordering data
3SB1D Indicator lamps
Pushbutton IndicatorGreen B71P G12 16185 B71P G21 16186 B71P G22 16187 B71P G30 16188Red - B71P R12 16189 B71P R21 16190 B71P R22 16191 B71P R30 16192Black - B71P H12 16193 B71P H21 16194 B71P H22 16195 B71P H30 16196Yellow - B71P Y12 16197 B71P Y21 16198 B71P Y22 16199 B71P Y30 16200Blue - B71P B12 16201 B71P B21 16202 B71P B22 16203 B71P B30 16204
Color 1NO+2NC 2NO+1NC 2NO+2NC 3NO
-
3SB71P Pushbutton
Voltage
----
-Type code Order code Type code Order code Type code Order code Type code Order code
3SB71PD Pushbutton+Indicator
Red B71PD R12V12 16208 B71PD R21V12 16209 - - B71PD R30V12 16210White B71PD W12V12 16211 B71PD W21V12 16212 - - B71PD W30V12 16213Yellow B71PD Y12V12 16214 B71PD Y21V12 16215 - - B71PD Y30V12 16216Blue B71PD B12V12 16217 B71PD B21V12 16218 - - B71PD B30V12 16219
Green B71PD G12V24 16220 B71PD G21V24 16221 - - B71PD G30V24 16222
White B71PD W12V24 16226 B71PD W21V24 16227 - - B71PD W30V24 16228Yellow B71PD Y12V24 16229 B71PD Y21V24 16230 - - B71PD Y30V24 16231Blue B71PD B12V24 16232 B71PD B21V24 16233 - - B71PD B30V24 16234
Green B71PD G12V110 16235 B71PD G21V110 16236 - - B71PD G30V110 16237Red B71PD R12V110 16238 B71PD R21V110 16239 - - B71PD R30V110 16240White B71PD W12V110 16241 B71PD W21V110 16242 - - B71PD W30V110 16243Yellow B71PD Y12V110 16244 B71PD Y21V110 16245 - - B71PD Y30V110 16246Blue B71PD B12V110 16247 B71PD B21V110 16248 - - B71PD B30V110 16249
Green B71PD G12V230 16250 B71PD G21V230 16251 - - B71PD G30V230 16252Red B71PD R12V230 16253 B71PD R21V230 16254 - - B71PD R30V230 16255White B71PD W12V230 16256 B71PD W21V230 16257 - - B71PD W30V230 16258Yellow B71PD Y12V230 16259 B71PD Y21V230 16260 - - B71PD Y30V230 16261Blue B71PD B12V230 16262 B71PD B21V230 16263 - - B71PD B30V230 16264
Pushbutton Indicator Type code Order code Type code Order code Type code Order code Type code Order codeColor 1NO+2NC 2NO+1NC 2NO+2NC 3NOVoltage
(VAC/DC)Green B71PD G12V12 16205 B71PD G21V12 16206 - - B71PD G30V12 16207
Red B71PD R12V24 16223 B71PD R21V24 16224 - - B71PD R30V24 16225
3SB71D Indicator
Green - B71D G12 16265 B71D G24 16266 B71D G110 16267 B71D G230 16268Red - B71D R12 16269 B71D R24 16270 B71D R110 16271 B71D R230 16272White - B71D W12 16273 B71D W24 16274 B71D W110 16275 B71D W230 16276Yellow - B71D Y12 16277 B71D Y24 16278 B71D Y110 16279 B71D Y230 16280Blue - B71D B12 16281 B71D B24 16282 B71D B110 16283 B71D B230 16284
Pushbutton IndicatorColor 12V AC/DC
Type code Order code Type code Order code Type code Order code Type code Order code24V AC/DC 110V AC/DC 230V AC/DC
Color Pack.12
1212
1212
RedGreenYellowWhiteGrey
B1D N1 2473424735247362473724738
Type codeNeon bulbNeon bulbNeon bulbNeon bulbNeon bulb
B1D N2B1D N3B1D N4B1D N5
1212121212
2424242424
110110110110110
230230230230230
Order codeIllumination Indicator
2-73www.sassin.com
Modular Devices
Surge Protective Devices Series 3SU71
Functions
Types 2 surge arresters Handling energy from distant/ indirect lightning strikes or from switching operations Feature lower protection level (Up) Recommended at the incoming of installation for locations with no exposure to direct lightning impulses
Technical specification of the integrated auxiliary contact
Contact complement: 1NO (1 make contact) +1NC (1 normally closed contact) Min. load:24V D.C. - 10 mA Max. load:240V A.C. - 1 A
Instruction of type code
Series code
U71 10 D 1 275
Max. discharge current (kA):10, 20, 40, 60Class:D,C
Max. cont. operating voltage
Number of poles: 1,1+N, 2, 3, 3+N, 4
Technical specifications
Type: 3SU71 Standard: IEC61643-1 Approval: CE Type / test class: 2/Ⅱ Number of poles: 1P, 1P+NPE, 2P, 2P+NPE, 3P, 3P+NPE, 4P Type of current: AC Frequency (Hz): 50/60 Rated voltage Un (V): 230/400 Max.Cont. operating voltage U (V) : 140,275,320,385,420 Max.discharge current Imax (8/20) per pole (kA): 10, 20, 40, 60 Norminal discharge current In (8/20) per pole (kA): 5, 10, 15, 20 Voltage protection level Up (kV) : 1.0, 1.2, 1.2, 1.5 Tov (Temporary overvoltage) withstand UT (5s.) ( V) : 440 Continuous operating current Ic (mA) : <1 Degree of protection: Ip20, with connected conductors Pluggable cartridge: Yes State indicator: Yes Integrated auxiliary contact: Yes Conductor cross-sections
2 Solid and stranded (mm ) : 2-35 2 Finely stranded with end sleeve (mm ) 2-25
Terminals Terminal tightening torque ( ) : 2.8 Ambient temperature ( : -5 to +40, max. 95 % humidity Storage temperature ( : -40 ... +75
2 )
N·m℃)
℃) Connection Capacity (mm : 1-25
www.sassin.com2-74 www.sassin.com
Mod
ular
Dev
ices
Surge Protective DevicesSeries 3SU71
Max.Cont. operating voltage Uc(V)
Selection and ordering data
Type code Order code
Max.discharge current Imax (8/20) per pole(kA)
Nominal discharge current In (8/20) per pole(kA)
Number of
poles
140 1P1P+N2P3P3P+N4P
U71C 10D1/140 34823 U71C 10D1N/140 38093 U71C 10D2/140 34828 U71C 10D3/140 34833 U71C 10D3N/140 38098 U71 C10D4/140 34838
10
275 10 5 U71 C10D1/275 34824 20 10 U71C 20D1/275 34843 40 20 U71 C40D1/275 34859 60 30 U71 C60D1/275 34875
5
1P
10 5 U71C 10D1N/275 38094 20 10 U71 C20D1N/275 38103 40 20 U71C 40C1N/275 38111 60 30 U71 C60C1N/275 38119
1P+N
10 5 U71 C10D2/275 34829 20 10 U71C 20D2/275 34847 40 20 U71 C40C2/275 34863 60 30 U71 C60C2/275 34879
2P
3P 10 5 U71C 10D3/275 34834 20 10 U71 C20D3/275 34851 40 20 U71C 40C3/275 34867 60 30 U71 C60C3/275 34883
3P+N 10 5 U71C 10D3N/275 38099 20 10 U71C 20D3N/275 3810740 20 U71 C40C3N/275 3811560 30 U71C 60C3N/275 38123
4P 10 5 U71 C10D4/275 34839 20 10 U71 C20D4/275 3485540 20 U71 C40C4/275 3487160 30 U71 C60C4/275 34887
320 10 5 U71 C10D1/320 3482520 10 U71 C20D1/320 34845 40 20 U71C 40D1/320 3486060 30 U71C 60D1/320 34876
1P
10 5 U71C 10D1N/320 38095 20 10 U71C 20D1N/320 38104 40 20 U71 C40C1N/320 38112 60 30 U71C 60C1N/320 38120
1P+N
10 5 U71C 10D2/320 34830 20 10 U71C 20D2/320 34848 40 20 U71C 40C2/320 34864 60 30 U71C 60C2/320 34880
2P
3P 10 5 U71C 10D3/320 34835 20 10 U71C 20D3/320 34852 40 20 U71C 40C3/320 34868 60 30 U71C 60C3/320 34884
3P+N 10 5 U71C 10D3N/320 38100 20 10 U71C 20D3N/320 3810840 20 U71C 40C3N/320 3811660 30 U71C 60C3N/320 38124
4P 10 5 U71C 10D4/320 34840 20 10 U71C 20D4/320 3485640 20 U71C 40C4/320 3487260 30 U71C 60C4/320 34888
10 510 510 510 510 5
Auxiliary contact
with
with
with
2-75www.sassin.comwww.sassin.com
Modular Devices
Surge Protective Devices Series 3SU71
Max.Cont. operating voltage Uc(V)
Selection and ordering data
Type code Order code
Max.discharge current Imax (8/20) per pole(kA)
Nominal discharge current In (8/20) per pole(kA)
Number of
poles385 10 5 U71C 10D1/385 34826
20 10 U71C 20D1/385 34845 40 20 U71C 40D1/385 34861 60 30 U71 C60D1/385 34877
1P
10 5 U71C 10D1N/385 38096 20 10 U71C 20D1N/385 38105 40 20 U71C40C1N/385 38113 60 30 U71C 60C1N/385 38121
1P+N
10 5 U71C 10D2/385 34831 20 10 U71C 20D2/385 34849 40 20 U71C 40C2/385 34865 60 30 U71C 60C2/385 34881
2P
3P 10 5 U71C 10D3/385 34836 20 10 U71C 20D3/385 34853 40 20 U71C 40C3/385 34869 60 30 U71C 60C3/385 34885
3P+N 10 5 U71C 10D3N/385 38101 20 10 U71C 20D3N/385 3810940 20 U71C 40C3N/385 3811760 30 U71C 60C3N/385 38125
4P 10 5 U71C 10D4/385 34841 20 10 U71C 20D4/385 3485740 20 U71C 40C4/385 3487360 30 U71C 60C4/385 34889
420 10 5 U71C 10D1/420 34827 20 10 U71C 20D1/420 34846 40 20 U71C 40D1/420 34862 60 30 U71C 60D1/420 34878
1P
10 5 U71C 10D1N/420 38097 20 10 U71C 20D1N/420 38106 40 20 U71C 40C1N/420 38114 60 30 U71C 60C1N/420 38122
1P+N
10 5 U71C 10D2/420 34832 20 10 U71C 20D2/420 34850 40 20 U71C 40C2/420 34866 60 30 U71C 60C2/420 34882
2P
3P 10 5 U71C 10D3/420 34837 20 10 U71C 20D3/420 34854 40 20 U71C 40C3/420 34870 60 30 U71C 60C3/420 34886
3P+N 10 5 U71C 10D3N/420 38102 20 10 U71C 20D3N/420 3811040 20 U71C 40C3N/420 3811860 30 U71C 60C3N/420 38126
4P 10 5 U71C 10D4/420 34842 20 10 U71C 20D4/420 3485840 20 U71 C40C4/420 3487460 30 U71C 60C4/420 34890
Auxiliary contact
with
with
www.sassin.com2-76 www.sassin.com
Mod
ular
Dev
ices
Surge Protective DevicesSeries 3SU1
Functions
Types 2 surge arresters Handling energy from distant/ indirect lightning strikes or from switching operations Feature lower protection level (Up) Recommended at the incoming of installation for locations with no exposure to direct lightning impulses 3SU1 DC provide protection for equipment on photovoltaic connected system, against transient overvoltages that occur on the electrical network
Technical specification of the integrated auxiliary contact
Contact complement: 1NO (1 make contact) +1NC (1 normally closed contact) Min. load:24V D.C. - 10 mA Max. load:240V A.C. - 1 A
Instruction of type code
Series code
U1 10 D 1 275
Max. discharge current (kA):10, 20, 40, 60Class:D, C
Max. cont. operating voltage
Number of poles: 1,2, 3, 4
Technical specifications
Type: 3SU1 3SU1DC Standard: IEC61643-1 Approval: CE Type / test class: 2/Ⅱ Number of poles: 1P, 1P+NPE, 2P, 2P+NPE, 3P, 3P+NPE, 4P 2P Type of current: AC DC Frequency (Hz): 50/60 Rated voltage Un (V): 230/400 Max.Cont. operating voltage U (V) : 440 Max.discharge current Imax (8/20) per pole (kA): 10, 20, 40, 60 40 Norminal discharge current In (8/20) per pole (kA): 5, 10, 15, 20 20 Voltage protection level Up (kV) : 1.0, 1.2, 1.2, 1.5 3.8 Tov (Temporary overvoltage) withstand UT (5s.) ( V) : 440 Continuous operating current Ic (mA) : <1 Degree of protection: Ip20, with connected conductors Pluggable cartridge: Yes NO. State indicator: Yes Yes Integrated auxiliary contact: Yes NO. Conductor cross-sections
2 Solid and stranded (mm ) : 2-35 2-252 Finely stranded with end sleeve (mm ) 2-25 2-16
Terminals Terminal tightening torque ( ) : 2.8 Ambient temperature ( : -5 to +40, max. 95 % humidity Storage temperature ( : -40 ... +75
2 )
N·m℃)
℃) Connection Capacity (mm : 1-25
2-77www.sassin.comwww.sassin.com
Modular Devices
Surge Protective Devices Series 3SU1
10204060
5101520
11.21.21.5
10204060
5101520
11.21.21.5
Max.Cont. operating voltage Uc(V)
Selection and ordering data
1
Type code Order code
Max.discharge current Imax (8/20) per pole(kA)
Nominal discharge current In (8/20) per pole(kA)
Voltage protection level Up(kV)
275
10204060
5101520
11.21.21.5
L
1+NPE 275
10204060
5101520
11.21.21.5
2 275
10204060
5101520
11.21.21.5
2+NPE 275
10204060
5101520
11.21.21.5
NL
N L
NL
N L
3 275
10204060
5101520
11.21.21.5
3+NPE 275
10204060
5101520
11.21.21.5
4 275
102040
51015
11.21.2
60 20 1.5
L1L2L3
L1 L2 L3
NL1
L1 L2N
L2
NL1
L3
L1 L2 L3N
L2
NL1
L3
L1 L2 L3N
L2
Number of
poles
L
10204060
5101520
11.21.21.5
NL
N L
4 275
102040
51015
11.21.2
60 20 1.5
without
Auxiliary contact
with
with
without
with
without
with
without
NL1
L1 L2N
L2
NL1
L3
L1 L2 L3N
L2
3
2
1
U1 10D1/275U1 20D1/275U1 40C1/275U1 60C1/275U1 10D1N/275U1 20D1N/275U1 40C1N/275U1 60C1N/275
2903929053290672907429043290572907129078
U1C 10D1/275U1C 20D1/275U1C 40C1/275U1C 60C1/275
32683 32687 32691 32695
U1 10D2/275U1 20D2/275U1 40C2/275U1 60C2/275U1 10D2N/275U1 20D2N/275U1 40C2N/275U1 60C2N/275
U1 10D3/275U1 20D3/275U1 40C3/275U1 60C3/275U1 10D3N/275U1 20D3N/275U1 40C3N/275U1 60C3N/275
U1 10D4/275U1 20D4/275U1 40C4/275U1 60C4/275
U1C 10D2/275U1C 20D2/275U1C 40C2/275U1C 60C2/275
U1C 10D3/275U1C 20D3/275U1C 40C3/275U1C 60C3/275
U1C 10D4/275U1C 20D4/275U1C 40C4/275U1C 60C4/275
290402905429068290752904429058290722907932684 32688 32692 32696
2904129055290692907629045290592907329080
29042290562907029077
32685 32689 32693 32697
32686 32690 32694 32698
275
275
275
2-78 www.sassin.com
Mod
ular
Dev
ices
Surge Protective DevicesSeries 3SU1
10204060
5101520
11.21.21.5
10204060
5101520
11.21.21.5
Max.Cont. operating voltage Uc(V)
Selection and ordering data
1
Type code Order code
Max.discharge current Imax (8/20) per pole(kA)
Nominal discharge current In (8/20) per pole(kA)
Voltage protection level Up(kV)
400
10204060
5101520
11.21.21.5
L
1+NPE
10204060
5101520
11.21.21.5
2
10204060
5101520
11.21.21.5
2+NPE
10204060
5101520
11.21.21.5
NL
N L
NL
N L
3
10204060
5101520
11.21.21.5
3+NPE
10204060
5101520
11.21.21.5
4
102040
51015
11.21.2
60 20 1.5
L1L2L3
L1 L2 L3
NL1
L1 L2N
L2
NL1
L3
L1 L2 L3N
L2
NL1
L3
L1 L2 L3N
L2
Number of
poles
L
10204060
5101520
11.21.21.5
NL
N L
4
102040
51015
11.21.2
60 20 1.5
without
Auxiliary contact
with
with
without
with
without
with
without
NL1
L1 L2N
L2
NL1
L3
L1 L2 L3N
L2
3
2
1
U1 10D1/400U1 20D1/400U1 40C1/400U1 60C1/400U1 10D1N/400U1 20D1N/400U1 40C1N/400U1 60C1N/400U1C 10D1/400U1C 20D1/400U1C 40C1/400U1C 60C1/400
U1 10D2/400U1 20D2/400U1 40C2/400U1 60C2/400U1 10D2N/400U1 20D2N/400U1 40C2N/400U1 60C2N/400
U1 10D3/400U1 20D3/400U1 40C3/400U1 60C3/400U1 10D3N/400U1 20D3N/400U1 40C3N/400U1 60C3N/400
U1 10D4/400U1 20D4/400U1 40C4/400U1 60C4/400
U1C 10D2/400U1C 20D2/400U1C 40C2/400U1C 60C2/400
U1C 10D3/400U1C 20D3/400U1C 40C3/400U1C 60C3/400
U1C 10D4/400U1C 20D4/400U1C 40C4/400U1C 60C4/400
400
400
400
400
400
400
400
400
400
400
293122932629340293472931629330293442935132699 32703 32707 32711
32700 32704 32708 32712
32701 32705 32709 32713
32702 32706 32710 32714
2931329327293412934829317293312934529352
2931429328293422934929318293322934629353
29315293292934329350
2-79www.sassin.com
Modular Devices
Surge Protective Devices Series 3SU1 DC
Max.Cont. operating voltage Uc(V)
Selection and ordering data
1Type code Order code
Max.discharge current Imax (8/20) per pole(kA)
Nominal discharge current In (8/20) per pole(kA)
Voltage protection level Up(kV)
275
10204060
5101520
11.21.21.5
L
320
10204060
5101520
11.21.21.5
NL
N L
Replacement cartridges for surge protective devices type 2
385
10204060
5101520
11.21.21.5
Surge protective devices, photovoltaic
404040
202020
3.83.83.8
3 3006001000
400
10204060
5101520
11.21.21.5
440
10204060
5101520
11.21.21.5
Number of
poles
Max.cont operating voltage Uc(V)
. Max discharge current Imax (8/20) per pole(kA)
. Nominal discharge current In (8/20) per pole(kA)
Voltage protection level Up(kA)
Number of
poles Type code Order code
U1 300 DU1 600DU1 1000 D
326823268118589
U1RP 27510U1RP 27520U1RP 27540U1RP 27560
U1RP 32010U1RP 32020U1RP 32040U1RP 32060
U1RP 44010U1RP 44020U1RP 44040U1RP 44060
U1RP 40010U1RP 40020U1RP 40040U1RP 40060
U1RP 38510U1RP 38520U1RP 38540U1RP 38560
32962 32963 32964 32965
32966 32967 32968 32969
32974 32975 32976 32977
32978 32979 32980 32981
32970 32971 32972 32973
www.sassin.com2-80 www.sassin.com
Mod
ular
Dev
ices
Surge Protective DevicesSeries 3SU1 Modular
Application
Technical specifications
These plug-in modular forms the surge arrester with relevant bases.
3SU1 MOD150 40
Type 2Class II
150V
20kA40kA
≤0.8kV≤0.6kV≤25ns
-40℃-80℃green/red
Type 2 Type 2 Type 2 Type 2
3SU1 MOD275 40
3SU1 MOD320 40
3SU1 MOD385 40
3SU1 MOD440 40
Class II275V
20kA40kA
≤1.3kV≤1.0kV≤25ns
-40℃-80℃green/red
Class II320V
20kA40kA
≤1.5kV≤1.2kV≤25ns
-40℃-80℃green/red
Class II385V
20kA40kA
≤1.8kV≤1.4kV≤25ns
-40℃-80℃green/red
Class II440V
20kA40kA
≤2.0kV≤1.6kV≤25ns
-40℃-80℃green/red
SPD classification according to IEC61643-11
SPD classification according to IEC61643-1
Operating state/fault indication
Nominal discharge current (8/20μs) InMax. discharge current (8/20μs) Imax
Voltage protection level 5kA Up
Max. continuous operating a.c. voltage Uc
Voltage protection level Up
Response time tAOperating temperature range Tu
Thermalplastic UL94-V0Enclosure material
Application
These plug-in modular is suitable for Imax 40kA modular to form 1+1 or 3+1 products
Technical specifications
Total 12 types of bases are available to form the whole range of our products.
Application
Technical specifications
Type 2Class II255V20kA40kA
≤1.5kV
≤100ns-40℃-80℃
green/red
100Arms
Thermalplastic UL94-V0
Type 2Class II255V40kA
80kA
≤1.5kV
≤100ns-40℃-80℃
green/red
100Arms
Thermalplastic UL94-V0
Max. continuous operating a.c. voltage Uc
Voltage protection level Up
Response time tAOperating temperature range TuOperating state/fault indication
Nominal discharge current (8/20μs) InMax. discharge current (8/20μs) Imax
SPD according to EN 61643 - 11
SPD according to IEC 61643-1
Follow current extinguishing capability [N-PE]
Enclosure material
3SU1 MOD NPE 40MOD NPE 3SU1 MOD NPE 80
3SU1 T2BASE 3
-40℃-80℃2 2.5mm2 35mm
BASE 3SU1 T2BASE 4
3SU1 T2BASE 3+1
BR T2BASE 2
3SU1 T2BASE 1+1
3SU1 T2BASE 1
35mm Din railThermal plastic UL94-V0
-40℃-80℃22.5mm235mm
-40℃-80℃22.5mm235mm
-40℃-80℃22.5mm235mm
-40℃-80℃22.5mm235mm
-40℃-80℃22.5mm235mm
Operating temperature range TU
Cross sectional area (max.)For mounting on
Cross sectional area (min.)
Enclosure material
Type
www.sassin.comwww.sassin.com
Modular Devices
Surge Protective Devices Series 3SU2-50GR
3SU2-50GR
Type 1
Class I
275V
50kA
50kA
≤2.0kV
10kA rms
500A gL
≤100ns
210mm235mm
35mm Din rail
Thermalplastic UL94-V0
IP20
Max. continuous operating a.c. voltage Uc
Norminal discharge current (8/20μs) In
Voltage protection level Up
Follow current extinguishing capability a.c. Ifi
Max. backup fuse
Response time tA
Operating temperature range Tu
Cross-section area(Max.)
For mounting on
Enclosure material
Degree of protection
Lightning impulse current (10/350μs) Iimp
3SU2-50GR N+1
Type 1
Class I
275V
50kA
50kA
10kA rms
500A gL
≤100ns
210mm235mm
IP20
-40℃-80℃-40℃-80℃
35mm Din rail
Cross-section area (Min.)
SPD classification according to IEC61643-11
SPD classification according to IEC61643-1
Thermalplastic UL94-V0
Application
Technical specifications
Outline and installation dimensions
Type
Poles 1, 2, 3, 4 3+1, 1+1
3SU2-50GR 4P is suitable for TN-S system3SU2-50GR 3P is suitable for TN-C system3SU2-50GR 2P surge arrester is suitable for single-phaseTN system3SU2-50GR 3+1 and 1+1 surge arrester is suitable for TT system
≤2.0kV/≤1.5kV
Unit in mm
2-81
www.sassin.com2-82 www.sassin.com
Mod
ular
Dev
ices
Surge Protective DevicesSeries 3SU2-25GR
Application
3SU2-25GR 4P is suitable for TN-S system3SU2-25GR 3P is suitable for TN-C system3SU2-25GR 2P surge arrester is suitable for single-phaseTN system
Type 1
Class I
275V
25kA
25kA
≤2.5kV
315A
≤100ns
210mm
235mm
35mm Din rail
IP20
SPD classifiication according to IEC61643-11
SPD classifiication according to IEC61643-1
Max. backup fuse
Cross-section area(Min.)
Cross-section area (Max.)
For mounting on
Enclosure material
Degree of protection
3SU2-25GR
Type 1
Class I
275V
25kA
25kA
≤2.5kV
315A
≤100ns
210mm
235mm
35mm Din rail
IP20
2.5kA rms 2.5kA rms
-40℃-80℃ -40℃-80℃
Max. continuous operating a.c. voltage Uc
Norminal discharge current (8/20μs) In
Lightning impulse current (10/350μs) Iimp
Voltage protection level Up
Follow current extinguishing capability a.c. Ifi
Operating temperature range Tu
Thermalplastic UL94-V0 Thermalplastic UL94-V0
Response time tA
Type
Poles 1, 2, 3, 4 3+1, 1+1
3SU2-25GR N+1
3SU2-25GR 3+1 and 1+1 surge arrester is suitable for TT system
Technical specifications
Outline and installation dimensions
Unit in mm
2-83www.sassin.comwww.sassin.com
Modular Devices
Surge Protective Devices Series 3SU3-25M
Application
Technical specifications
3SU3-25M 4P is suitable for TN-S system3SU3-25M 3P is suitable for TN-C system3SU3-25M 2P surge arrester is suitable for single-phaseTN system.3SU3-25M 3+1 and 1+1 surge arrester is suitable for TT system.
Type 1 Type2
275V
25kA
25kA/100kA(NPE)
315A gl
≤25ns
210mm
235mm
35mm Din rail
IP20
SPD classifiication according to IEC61643-11
SPD classifiication according to IEC61643-1
Max. backup fuse
Cross-section area(Min.)
Cross-section area (Max.)
For mounting on
Enclosure material
Degree of protection
3SU3-25M
Class I Class II
275V
25kA
315A gl
210mm
235mm
35mm Din rail
IP20
-40℃-80℃ -40℃-80℃
Max. continuous operating a.c. voltage Uc
Norminal discharge current (8/20μs) In
Lightning impulse current (10/350μs) Iimp
Voltage protection level Up
Follow current extinguishing capability a.c. Ifi
Operating temperature range Tu
Thermalplastic UL94-V0 Thermalplastic UL94-V0
Response time tA
Type
Poles 1, 2, 3, 4 3+1, 1+1
3SU3-25M N+1
Class I Class II
Type 1 Type2
25kA/100kA(NPE)
≤1.3kV ≤1.3kV≤1.5kV
100A rms(NPE)
Maximum discharge current (8/20μs) Imax 160kA 160kA
≤25ns/ ≤100ns
Outline and installation dimensions
Unit in mm
2-84 www.sassin.com
Mod
ular
Dev
ices
Functions
Remote switching and controlling of power circuits Used in building automation,controlling of small pumps, ventilations, heating systems, lighting systems, and so on
Technical specifications
Type: 3SCH8-25 3SCH8-63 Standards: IEC61095 IEC60947-4-1 Approvals: CE Number of poles: 2, 4 Type of current: AC Frequency (Hz): 50/60 Rated voltage Un (V): 230/400 Rated current In in AC-7a /Ac1 (A) 10, 16, 20, 25 25, 32, 40, 63 Rated current In in AC-7b /Ac1 (A) 4, 5.5, 7, 8.5 8.5, 12, 15, 25 Rated power in AC3 (Kw): 230V 2-5 5-13 400V 6-13 15-40 Control circuit voltage (V) : 24, 230 Mechanical life (times): 300,000 Electrical life (times): AC-7a /AC1 10,000 80, 000 AC-7b /AC1 50,000 40,000 Degree of protection: IP20, with connected conductors Conductor cross-sections
2 Solid and stranded (mm ) : 2-25 2 Finely stranded with end sleeve (mm ) 2-25
Terminals Terminal tightening torque ( ) : 0.8-2.4 Ambient temperature ( : -5 ~ +40, max. 95 % humidity Storage temperature ( : -40 ~ +75
2(mm )
N •m℃)
℃) ℃ Connection Capacity : 1-25
Instruction of type code
Quantity of auxiliary contactCoil code
Series code
Rated current
CH8 25 2 10 11 B7
Frame current: 25, 63
Number of poles: 2, 4
Mini ContactorsSeries 3SCH8
2-85www.sassin.com
Modular Devices
Mini Contactors Series 3SCH8
(1) Please contact us if any other coil voltage required
Selection and ordering data
CH825 410 22B7 25904259052590625907259082590925910259112591225913259142591525916259172591825919
4 2NO+2NC3NO+1NC4NO4NC
CH825 410 31B7CH825 410 40B7CH825 410 04B7
2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC
CH825 416 22B7CH825 416 31B7CH825 416 40B7CH825 416 04B7CH825 420 22B7CH825 420 31B7CH825 420 40B7CH825 420 04B7CH825 425 22B7CH825 425 31B7CH825 425 40B7CH825 425 04B7
CH825 210 11B7 2589625897258982589925900259012590225903
Type code Order code
2 1NO+1NC2NO
24 10
16
20
25
24 24 24 24 24 24 24
CH825 210 20B7CH825 216 11B7CH825 216 20B7CH825 220 11B7CH825 220 20B7CH825 225 11B7CH825 225 20B7
CH825 210 11P7 2615626157261582615926160261612616226163
CH825 210 20P7CH825 216 11P7CH825 216 20P7CH825 220 11P7CH825 220 20P7CH825 225 11P7CH825 225 20P7
CH825 410 22P7 26164261652616626167261682616926170261712617226173261742617526176261772617826179
CH825 410 31P7CH825 410 40P7CH825 410 04P7
2.2
3333
3.53.53.53.54444
22
3.23.24455
22
3.23.24455
CH825 416 22P7CH825 416 31P7CH825 416 40P7CH825 416 04P7CH825 420 22P7CH825 420 31P7CH825 420 40P7CH825 420 04P7CH825 425 22P7CH825 425 31P7CH825 425 40P7CH825 425 04P7
Rated control Power in (KW)Control
voltage (Vac)
Contact position
Rated current In (A)
10
16
20
25
1NO+1NC2NO1NO+1NC2NO1NO+1NC2NO
Width18mm mods
11111111
Numbers ofPoles
1NO+1NC2NO1NO+1NC2NO1NO+1NC2NO1NO+1NC2NO
230 230 230 230 230 230 230 230
10
16
20
25
10
16
20
25
24 2424 24 24 24 24 24 24242424 24 24 24 24
10
25
10
25
2525
2020
2020
1616
1616
1010
2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC
230 230 230 230 230230 230230230 230 230 230 230 230230 230
10
25
10
25
2525
2020
2020
1616
1616
1010
AC-7a AC
4
5.5
7
8.5
4
5.5
7
8.5
AC-7b AC
AC-7a/230V
AC-7b/230V
4
5.5
7
8.5
4
5.5
7
8.5
0.75
1.01.01.21.2
0.75
1.41.4
0.75
1.01.01.21.2
0.75
1.41.4
AC-7a/400V
AC-7b/400V
4
8.5
4
8.5
8.58.5
7
5.5
44
5.55.55.5
777
4
8.5
4
8.5
8.58.5
7
5.5
44
5.55.55.5
777
6.2
10
13
15151515
6.26.26.2
101010
131313
2.22.22.2
6.2
10
13
15151515
6.26.26.2
101010
131313
2.2
3333
3.53.53.53.54444
2.22.22.2
A1
A2
1 3
2 4
220/240V~
R1
R2
A1
A2
1
2
220/240V~
A1
A2
1 3 5 7
2 4 6 8
220/240V~
A1
A2
R 1 3 R31
2 R 2 4 R4
220/240V~
A1
A2
1 3 5 R1
2 4 6 R2
220/240V~
A1
A2
1 3 5 7
2 4 6 8
220/240V~
11111111
2222222222222222
2222222222222222
2-86 www.sassin.com
Mini ContactorsSeries 3SCH8
www.sassin.com
Mod
ular
Dev
ices
Selection and ordering data
Type code Order code
Control voltage (Vac)
Contact position
Width18mm mods
Numbers ofPoles
CH863 425 22B7 25932259332593425935259362593725938259392594025941259422594325944259452594625947
2NO+2NC3NO+1NC4NO4NC
CH863 425 31B7CH863 425 40B7CH863 425 04B7CH863 432 22B7CH863 432 31B7CH863 432 40B7CH863 432 04B7CH863 440 22B7CH863 440 31B7CH863 440 40B7CH863 440 04B7CH863 463 22B7CH863 463 31B7CH863 463 40B7CH863 463 04B7
CH863 225 11B7 259202592125922259232592425925259262592725928259292593025931
1NO+1NC2NO
25
2NCCH863 225 20B7CH863 225 02B7CH863 232 11B7CH863 232 20B7CH863 232 02B7CH863 240 11B7CH863 240 20B7CH863 240 02B7CH863 263 11B7CH863 263 20B7CH863 263 02B7
CH863 225 11P7 261802618126182261832618426185261862618726188261892619026191
CH863 225 20P7CH863 225 02P7CH863 232 11P7CH863 232 20P7CH863 232 02P7CH863 240 11P7CH863 240 20P7CH863 240 02P7CH863 263 11P7CH863 263 20P7CH863 263 02P7
CH863 425 22P7 26192261932619426195261962619726198261992620026201262022620326204262052620626207
CH863 425 31P7CH863 425 40P7CH863 425 04P7CH863 432 22P7CH863 432 31P7CH863 432 40P7CH863 432 04P7CH863 440 22P7CH863 440 31P7CH863 440 40P7CH863 440 04P7CH863 463 22P7CH863 463 31P7CH863 463 40P7CH863 463 04P7
(1) Please contact us if any other coil voltage required
555
6.56.56.58.58.58.5131313
2525323232404040636363
242424242424242424242424
1NO+1NC2NO2NC1NO+1NC2NO2NC1NO+1NC2NO2NC
1NO+1NC2NO
25
2NC2525323232404040636363
230230230230230230230230230230230230
1NO+1NC2NO2NC1NO+1NC2NO2NC1NO+1NC2NO2NC
2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC
2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC2NO+2NC3NO+1NC4NO4NC
636363
63404040403232323225252525 230
230230230230230230230230230230230230230230230
636363
63404040403232323225252525 15
151515212121212626262640
24242424242424242424242424242424
2
4
Rated current in in (A)AC-7a/Ac-1
AC-7b/Ac-1
Rated control Power in (KW)AC-7a/230V
AC-7b/230V
AC-7a/230V
AC-7b/230V
8.58.58.5121212151515252525
8.58.58.5121212151515252525
1.41.41.4222
2.52.52.5444
555
6.56.56.58.58.58.5131313
1.41.41.4222
2.52.52.5444
8.58.5
8.5
121212
15151525252525
15
12
8.5
8.58.5
8.5
121212
15151525252525
15
12
8.5
404040
15151515212121212626262640404040
4444
6.56.56.56.57.57.57.57.513131313
4444
6.56.56.56.57.57.57.57.513131313
A1
A2
1 3
2 4
220/240V~
R1
R2
A1
A2
1
2
220/240V~
R3
R4
A1
A2
R1
R2
220/240V~
A1
A2
1 3 5 7
2 4 6 8
220/240V~
A1
A2
R 1 3 R31
2 R 2 4 R4
220/240V~
A1
A2
1 3 5 R1
2 4 6 R2
220/240V~
A1
A2
1 3 5 7
2 4 6 8
220/240V~
222222222222
222222222222
3333333333333333
3333333333333333
2-87www.sassin.com
Mini Contactors Series 3SCH8
www.sassin.com
Modular Devices
Outline and installation dimensions
18 65.5
49.5
85
35
45
6749.5
85 35
45
36
3SCH8-25 2P
36 6749.5
85 35
45
54 6749.5
85 35
45
3SCH8-25 4P
3SCH8-63 2P 3SCH8-63 4P
2-88 www.sassin.com
Mod
ular
Dev
ices
www.sassin.com
Mini ContactorsSeries 3SCH8
Application case of mini contactor
Remote indication of lighting statusMCB control 3SCH8 contactor.Two indicators show
2-89www.sassin.com
Modular Devices
www.sassin.com
Fuse Holders Series RT18
Functions
Widely used in terminal distribution system Being complete series of terminal distribution system together with series 3SB71
Technical specifications
Type: RT18-20X RT18-32/X RT18-63/X Standards: IEC60269 Approvals: CE Fuse: 8×32 10×38 14×51 Poles: 1 1, 2, 3 1, 2, 3 Type of current: AC Frequency (Hz): 50/60 Rated voltage Un (V): 230/400 Rated current (A): 20 32 63 Degree of protection: IP20 Conductor cross-sections
2 Solid and stranded (mm ): 2-252 2 Finely stranded with end sleeve (mm ) 2-16mm
Terminals Terminal tightening torque ( ) : 2.5 Ambient temperature ( : -5 to +40, max. 95 % humidity Storage temperature ( : -40~ +75
2 (mm )
N·m℃)
℃) Connection Capacity : 1-25
Instruction of type code
Outline and installation dimensions
TypeA828282
106106106
B787878
103103103
C353535
353535
D636363
808080
Dimension(mm)E
183654
265278
CBA
D
E E
1P 2P 3P
E
Code of indicator
Series code
RT18 A 1 X
Frame
Number of poles
RT18-32 1PRT18-32 2PRT18-32 3P
RT18-63 1PRT18-63 2PRT18-63 3P
2-90 www.sassin.com
Fuse HoldersSeries RT18
Mod
ular
Dev
ices
Selection and ordering data
Type Code Order CodeFuseIndicatorRated current In (A)Number of poles
1 20 yes 8 32×
1 32 yes 10 38×2 32 yes 10 38×3 32 yes 10 38×
1 63 yes 14 51×2 63 yes 14 51×3 63 yes 14 51×
1 32 No 10 38×2 32 No 10 38×3 32 No 10 38×
1 63 No 14 51×2 63 No 14 51×3 63 No 14 51×
RT18A1XRT18A2XRT18A3X
RT18A0X
RT18B1XRT18B2XRT18B3X
RT18A1RT18A2RT18A3
RT18B1RT18B2RT18B3
246852468624687
32675
246892469024691
246932469424695
246972469824699
Type code Order code Maximum rated voltage (V)
Rated current In (A)Dimension (mm)
2461016
Cylindrical8.5×31.5
H.R.C Fuse
380
Cylindrical10×38
2461016202532
380
2470124702247032470424705247062470724708
Matched fuse base
RT18-20X
RT18-32RT18-32X
Cylindrical14×51
2461016202532405063
380 RT18-63RT18-63X
2470924710247112471224713247142471524716247172471824719
3242132422324233242432425
F08gL02F08gL04F08gL06F08gL10F08gL16F10gL02F10gL04F10gL06F10gL10F10gL16F10gL20F10gL25F10gL32F14gL02F14gL04F14gL06F14gL10F14gL16F14gL20F14gL25F14gL32F14gL40F14gL50F14gL63
www.sassin.com
Modular Devices
Over-Voltage and Under-Voltage ProtectorsSeries 3SVP6
2-91
Instruction of type code
Functions
Over-voltage and under-voltage protectionUsed in terminal distribution systemDouble busbur desgin, with stronger wiring abilitySelf restart and recovery Fault can be indicated by LEDInstalled in DIN rail
VP6 2U32VP6 2U40VP6 2U50VP6 2U63VP6 4U32VP6 4U40VP6 4U50VP6 4U63VP6 2D32VP6 2D40VP6 2D50VP6 2D63VP6 4D32VP6 4D40VP6 4D50VP6 4D63
27680276812768227683276842768527686276872768827689276902769127692276932769427695
Type code
Rated current
In (A) Pack.6666333366663333
32405063324050633240506332405063
Order code
Selection and ordering dataFunctions Diagram
Outline and installation dimensions
unit in mmWiring Diagram
Technical specifications
Standards: IEC 60255-1, IEC 61010-1Number of poles (P): 2, 4Rated current In(A): 32, 40, 50, 65Rated frequency (Hz): 50/60Rated voltage Ue (V): 220Over-voltage action cut-off value (VAC): 265Over-voltage recovery value (VAC): 257Under-voltage action cut-off value: 175Under-voltage recovery valueⅡ(VAC): 180Action delayed time: 1 secondsRecovery delayed time: 30 secondsIP degree: IP20Operating temperature: -5-40℃
Series code
Rated current
VP6 2 U 32
U: Upper incomingD: Lower incoming
Upper incoming
Lower incoming
Incoming
Number of
poles
67.5
82
82
36max
N
N
2
1
N
N 2
1
4
3
6
5N
N
1
2
N
N
2
1
4
3
6
5
2P 4P
72max
2
4
2
4
Number of poles (P): 2, 4
Ts:Power-up delayTt:Action delay time
Tr:Reset delay time
U
LED: Un
LED:Fault(>U)
LED:Fault(<U)
Tt Tt <Tt <TtTs Tr Tr
11-14
Upper incoming Lower incoming
2P 4P
2-92 www.sassin.com
Modular Sockets & Electric BellsSeries MS71 Series 3SU213
Mod
ular
Dev
ices
Technical specifications
Rated voltage AC (V): 8, 12, 24, 36, 230Rated frequency (Hz): 50/60Max. continuous duty (minute): 30Connection terminal:Pillar terminal with ClampConnection capacity, rigid conductor (mm²): 10
SU213 1 24753247542475524756247572475824759
Type code
SU213 2SU213 3SU213 4SU213 5SU213 6SU213 7
8122436
220230240
Rated voltage(VAC) Pack.
12
1212
12121212
Order code
Selection and ordering data
Functions
Widely used in terminal distribution system Being complete series of terminal distribution system together with series 3SB71
Technical specifications
Standard: IEC60884-1 Approval: CE Rated current (A): 16Modules: 2.5Rated voltage Ue(V) : 230/400Conduct or cross-sections
2Solid and stranded (mm ): 0.75-25
Selection and ordering data
Type code Order code
Rated current In (A)
Number of Poles2P+E 16 MS71 17727
45 0-0.32
92M
AX
68.3
35±
0.5
Outline and installation dimensions
Electric BellsSeries 3SU213
2-93www.sassin.com
Modular Devices
Time SwitchesSeries 3SE8,3SUL181H,3SRC18,3SHC18A
Functions
Controlling circuit opening and closing according to the scheduled program. Can be set on the scheduled program Available on hourly,daily and weekly version and equipped with a 16A contact Fitting applications such as shop lighting systems, public buildings, schools, heating and irrigation systems and so forth.
Technical specifications
Type:
3SE8 3SUL181H 3SRC18 3SHC18A
Standard:Approval:
Rated supply voltage: (V)Contact type: - - - 1NC OR 1NOSwitching capacityresistive load: (A) 16 16 16 16
inductive load: (A)Rated frequency: (Hz)Full time range 7 minutes 24 hours 20 minutes 24 hours or one weekMinimum setting unit: 0.5 minutes 30 minutes 0.5 minutes -Electrical life (times)Mechanical life (times)Modules(18mm): 1 3 1 2Operating temperature:Storage temperature :MountingTerminal size for cable (mm²)
-40 ... +75°C
2.5
IEC 60730-1CE
AC 220-240
450/60
-5 to +40°C,max. 95 % humidity
ON DIN RAIL
510 times 510 times 510 times 510 times710 times 710 times 710 times 710 times
In(A)
Selection and ordering data
Order code Type code Rated current
24 hours
20 minutes
24 hours or one week
3SE8
3SUL181H
3SRC18
3SHC18A
Full time range
16
16
16
16
E8 24776
HC18A 24777
ALC18 24780
7 minutes
13684SUL181H
2-94 www.sassin.com
Time switchesSeries 3SE8,3SUL181H,3SRC18,3SHC18A
Mod
ular
Dev
ices
Outline and installation dimensions
unit in mm
3SE8 3SUL181H 3SRC18 3SHC18A
35max
86
.5m
ax
45
.5m
ax
65max
48max
Technical Specifications
Selection and ordering data
BT8-8BT8-8
Pack.18VA
Rated output power Type code Order code
ApprovalRated input voltage AC (V)Rated output voltage AC (V)Rated frequency (Hz)Rated output power (VA)Consumption (W)Pollution class
CE230
4, 6, 8, 12, 16, 2450/60
81.15
2
24751
Outline and installation dimensions
6650
2813.5
36
6
36
88 82 64 45
Unit in mm
Doorbell TransformerSeries BT8
Modular Devices
2-95www.sassin.com
Switching Power Supply3SDR-60
Protections: short circuit/ over load/ over voltage
Application
Universal AC input/Full rangeInstalled on DIN railApprovals: CELED showing the working stateCooling by free air convectionAC input voltage range: 85~264VAC, 47-63Hz, 120~370VDCAC inrush current: cold start 27A at 115VAC 36A at 230VACDC adjustment range: ±10% rated output voltageOver load protection: 105%-150% rated output voltageWithstand voltage: 1/P: 3KVAC/ 1/P-FG: 1.5KVAC, liminuteWorking temperature(℃): 10~60 (refer to output devating curveConnection: 1/P: 2 poles-O/P: 4poles screw DIN terminal
Technical specifications
Selection and ordering data
5.0V0.0~6.5A12V0.0~4.5A15V0.0~4.0A24V0.0~2.5A
±2%±1%±1%±1%
3SDR-60-53SDR-60-123SDR-60-153SDR-60-24
76%82%83%84%
Model Number Output Tolerance R&N Efficiency Power80mV
120mV120mV150mV
60W60W60W60W
2-96 www.sassin.com
Distribution BoxesSeries 3SD5 & 3SD6
Mod
ular
Dev
ices
Functions
Equipped with various modular electric for the function of terminal power distribution . Suited for the installation of all Sassin individual modular devices. (RCDs, MCBs, RCBO’s, Isolators etc). Used in residential building, non-residential building, industry.
Technical specifications
Standard: IEC60439-3Approval: CEModules (No.): 4, 6, 8,12,18, 24, 36Row : Single row for 4, 6, 8,12,18 modules
2 rows for 24 modules3 rows for 36 modules
Rated frame current In(A): 63,100Color: White RAL 9003 and grey RAL 7035The color of door: Transparent,non transparentMounting type: Surface, Flush.Degree of protection: IP30Material: HIPS for body
AS for doorFire resistence: 650℃/30sAmbient temperature : (℃) -5 ~ +40,max. 95 % humidityStorage temperature( :℃) -40 ~+75
Instruction of type code
Number of modules
Color of visor
Series codeRated frame current
D5 6 W T 08
Color of base
Number of modules
Color of visor
Series codeRated frame current
D6 6 W T 08
Color of base
2-97www.sassin.com
Modular Devices
Distribution Boxes Series 3SD5 & 3SD6
Selection and ordering data
In(A)Rated current
Order code Type code 468
12182436
3SD5 flush mounting Color of base
Color of door Number of module
63 White
White
468
12182436
Transparent
63 Grey
Grey
Transparent
468
12182436468
12182436468
12182436468
12182436468
12182436468
12182436
White
100 White Transparent
Grey
100 TransparentGrey
D506WW04 23157
D506WT04 23159
D506WW06 23163
D506WT06 23165
D506WW08 23169
D506WT08 23171
D506WW12 23137
D506WT12 23139
D506WW18 23143
D506WT18 23145
D506WW24 23149
D506WT24 23150
D506WW36 23153
D506WT36 23154D506GG04 24555
D506GT04 24556
D506GG06 24557
D506GT06 24558
D506GG08 24559
D506GT08 24560
D506GG12 24563
D506GT12 24564
D506GG18 24565
D506GT18 24566
D506GG24 24567
D506GT24 24568
D506GG36 24569
D506GT36 24570D510WW04 30655
D510WT04 30656
D510WW06 30657
D510WT06 30658
D510WW08 30659
D510WT08 30660
D510WW12 30663
D510WT12 30664
D510WW18 30665
D510WT18 30666
D510WW24 30667
D510WT24 30668
D510WW36 30669
D510WT36 30670D510GG04 30697
D510GT04 30698
D510GG06 30699
D510GT06 30700
D510GG08 30701
D510GT08 30702
D510GG12 30705
D510GT12 30706
D510GG18 30707
D510GT18 30708
D510GG24 30709
D510GT24 30710
D510GG36 30711
D510GT36 30712
2-98 www.sassin.com
Distribution BoxesSeries 3SD5 & 3SD6
Mod
ular
Dev
ices
In(A)Rated current
Order code Type code 468
12182436
3SD6 surface mounting Number of module
63 White
White
468
12182436
Transparent
Grey
63 Transparent
468
12182436468
12182436468
12182436468
12182436468
12182436468
12182436
Grey
White
100 White Transparent
Grey
100 TransparentGrey
D606WW04 23161
D606WT04 23162
D606WW06 23167
D606WT06 23168
D606WW08 23173
D606WT08 23174
D606WW12 23141
D606WT12 23142
D606WW18 23147
D606WT18 23148
D606WW24 23151
D606WT24 23152
D606WW36 23155
D606WT36 23156D606GG04 24571
D606GT04 24572
D606GG06 24573
D606GT06 24574
D606GG08 24575
D606GT08 24576
D606GG12 24579
D606GT12 24580
D606GG18 24581
D606GT18 24582
D606GG24 24583
D606GT24 24584
D606GG36 24585
D606GT36 24586D610WW04 30671
D610WT04 30672
D610WW06 30673
D610WT06 30674
D610WW08 30675
D610WT08 30676
D610WW12 30679
D610WT12 30680
D610WW18 30681
D610WT18 30682
D610WW24 30683
D610WT24 30684
D610WW36 30685
D610WT36 30686D610GG04 30713
D610GT04 30714
D610GG06 30715
D610GT06 30716
D610GG08 30717
D610GT08 30718
D610GG12 30721
D610GT12 30722
D610GG18 30723
D610GT18 30724
D610GG24 30725
D610GT24 30726
D610GG36 30727
D610GT36 30728
Color of base
Color of door
2-99www.sassin.com
Distribution Boxes Series 3SD5 & 3SD6
Modular Devices
Outline and installation dimensions(3SD5)
unit in mm
Fitting inside of the enclose
Attached with sticky label for marking on wire front panel; ready equipped with zero line and earth terminal bar and attached with zero bar, earth bar marks and alarm mark; users can select to connect with wire or insulating busbar method.
Distribution box MLoops Zero bar length Zero bar holes Earth bar length Earth bar holes Width Height
(mm)
66666
6 888888
(mm)(piece)3M4X7+M4X73M4X7+M4X74M4X7+M4X76M4X7+M4X79M4X7+M4X7
6M4X7+2M4X7
29.529.53752
74.528+28
(mm)(piece)4M4X7+M4X76M4X7+M4X78M4X7+M4X7
10M4X7+2M4X713M4X7+2M4X720M4X7+4M4X7
375267
37+5274.5+37
60+60+28+28
(mm)468
12182436 60+60+60+28 24M4X7+4M4X7 60+28 6 810M4X7+2M4X7
Φ16
10
44
6.9
56
90
4,6,8 &12 》
24 》
24 》
Φ16
12
8
18 》
66
100
112 150
Φ25 Φ25 Φ25 Φ25Φ32
125 160
383838
4 》 6 》
184
Φ25 Φ25Φ32
198
4242
255
Φ32 Φ32Φ32
270
43 434545
Φ25 Φ25
8 》 12 》
366
Φ32 Φ32Φ32
379
41 =98=
Φ25 Φ25Φ32 Φ32
49 49 41
18 》
25
56
66
4,6,8 &12 》
136172
207279
22
1
25
1
397
18 》
305
34
5
24 》
98
45
5
36 》
341
50
5
36 》
295
36 》
257
98
31
5
2-100 www.sassin.com
Distribution BoxesSeries 3SD5 & 3SD6
Mod
ular
Dev
ices
99
18 》
94.5
φ16
4,6,8 &12 》
19
9
112
183
255
148
4,6,8 &12 》
22
0
362
18 》
24 》
97
36 》36 》
306.3
473.7
φ15 φ25
41
4 》
φ15 φ25
40
6 》
40
φ20 φ32
18 》
362
φ15 φ32
34 3438
8 》
38
φ20 φ25φ15 φ15 φ16 φ32
3435
12 》
35
φ20 φ25φ16 φ16φ16 φ25
34 41 41
24 》
255183148112
36 》
306.3271
92
326
271
24 》
Outline and installation dimensions(3SD6)
unit in mm
2-101www.sassin.com
Distributon BoxesSeries 3SD5T (Metal Base)
Modular Devices
Equipped with various modular electric for the function of the terminal power distributionSuited for the installation of all the Sassin individual modular device (RCDs, MCBs, RCBOs, Isolators, etc.)Used in the residential buildings, non-residential buildings and industryLifting installation rail, easy for installation
Functions
Technical Specifications
Selection and ordering data
3SD5T flush mountingD5T06GT04D5T06GT06D5T06GT08D5T06GT12D5T06GT18D5T06GG04D5T06GG06D5T06GG08D5T06GG12D5T06GG18
Transparent
Grey
Grey
Grey
Color of base
Number of module
468
1218468
1218
63A
Rated currentIn(A) Type code Order code
StandardApprovalModules (NO.)RowRated frame current In (A)ColorThe color of the doorMounting typeDegree of the protectionMaterial
Fire resistenceAmbient temperature (℃)
Storage temperature (℃)
IEC60439-3CE
4, 6, 8, 12, 18Single
63White RAL 9003, Grey RAL7035Transparent, non transparent
FlushIP40
HIPS for the body SAN for the door
Metal for the base 650℃/30s
-5~+40, 50% humidity permitted under max +40℃
-40~+75
Color of door
23160231662317223140231462315823164231702313823144
Outline and installation dimensions
A B
CD Hmax
3SD5-043SD5-063SD5-083SD5-123SD5-18
A(mm) B(mm) C(mm) D(mm) Hmax(mm)Type221221221221251
190.5190.5190.5190.5223.5
136172207279397
108.5142.5180.5252.5360.5
102102102102103
2-102 www.sassin.com
Distribution BoxesSeries 3SD8
Mod
ular
Dev
ices
Functions
Equipped with various modular electric for the function of terminal power distribution . Suited for the installation of all Sassin individual modular devices. (RCDs, MCBs, RCBO’s,Isolators etc). Used in residential building, non-residential building,industry.
Instruction of type code
Technical spcification Standard: IEC60439-3Approval: CEModules (No.): 4,7,10,13,16,21Row : Single Rated voltage In(A): 100Color: White RAL 9003 Color of door: Transparent,non transparentMounting type: Surface, Flush.Degree of protection: IP30Material: HIPS for body
AS for doorFire resistence: 650℃/30sAmbient temperature ( : ℃) -5 ~ +40,max. 95 % humidityStorage temperature :(℃) -40 ~ +75℃
In(A)
Selection and ordering data
Rated current Order code Type code 3SD8 Surface Mounting Color
of baseColor of door
Number of module
100 White
White
Transparent
47
10131621
47
10131621
D810WW04D810WW07D810WW10D810WW13D810WW16D810WW21
D810WT04D810WT07D810WT10D810WT13D810WT16D810WT21
231762317823180231822318423186231752317723179231812318323185
Number of modules
Color of visor
Series codeRated frame current
D8 6 W T 08
Code of base
2-103www.sassin.com
Distribution Boxes Series 3SD8
Modular Devices
Attached with sticky label for marking on wire front panel; ready equipped with zero line and earth terminal bar and attached with zero bar, earth bar marks and alarm mark; users can select to connect with wire or insulating busbar method.
Earth bar holes
Fitting inside of the enclosure
Outline and installation dimensions
1xØ6 + 1xØ5.8 + 3xØ5.41xØ6 + 1xØ5.8 + 6xØ5.41xØ6 + 1xØ5.8 + 10xØ5.41xØ6 + 1xØ5.8 + 8xØ5.41xØ6 + 1xØ5.8 + 8xØ5.41xØ6 + 1xØ5.8 + 8xØ5.4
1xØ6 + 1xØ5.8 + 6xØ5.41xØ6 + 1xØ5.8 + 8xØ5.4
1xØ6 + 1xØ5.8 + 11xØ5.4
1xØ6 + 1xØ5.8 + 3xØ5.41xØ6 + 1xØ5.8 + 4xØ5.41xØ6 + 1xØ5.8 + 8xØ5.41xØ6 + 1xØ5.8 + 11xØ5.41xØ6 + 1xØ5.8 + 14xØ5.41xØ6 + 1xØ5.8 + 18xØ5.4
Neutral bar holes 1 Neutral bar holes 2The Number of Module4 module7 module
10 module13 module16 module21 module
2-104 www.sassin.com
Metal Distribution BoxesSeries TY3
Mod
ular
Dev
ices
Equipped with various modular eletric for the function of terminal power distributionSuited for the installation of all Sassin individual modular devices(RCDs,MCBs,RCBOs,Isolators etc)Used in the residential buildings, non-residential buildings and industry.All-metal enclosure, safe and fireproof, firm, practical.
Functions
Features
Executive Standard: IEC17466Protection degree: IEC60529 IP40Approval: CENumber of modules: 8/12/16/18/24/32/40/48/60Rated voltage: 230/380V Color: WhiteType: flush type and suspension type
Selection and ordering data
typeTY3 F8TY3 F12TY3 F16TY3 F20TY3 F24TY3 F32TY3 F40TY3 F48TY3 F60TY3 S8TY3 S12TY3 S16TY3 S20TY3 S24TY3 S32TY3 S40TY3 S48TY3 S60
250320390460320390460390460250320390460320390460390460
365193652036521365223652336524365253652636527365283652936530365313653236533365343653536536
812162024324048608
1216202432404860
Instruction of type code
Series code
TY3
Mounting type: F: flush type S: surface type
Number of Module
8F
Number of Module
Outline Dimension (mm)
250250250250500500500750750250250250250500500500750750
92929292
10010010010010092929292
100100100100100
Flush type
Surface type
63
63
Rated currentIn(A) A B C Type code Order code
A
B
C
Modular Devices
2-105www.sassin.com
Series 3SEnclosed Isolator
WH
3SWH isolator is rigidly build to withstand more than just the vagaries of the weather, it is designed also for frequent switching even on severe load such as switching of motor loads or other highly inductive load. Suitable to be mounted in outdoor and indoor for diverse environment.
Standard: IEC/EN 60947-3, AS/NZS 3947Approvals: CB, CE, SAARated Voltage (VAC): 240/415Rated Frequency (Hz): 50/60Utilization category (A): AC 22/ AC 23Number of pole (P): 1, 2, 3, 4IP Protection: IP66
Applications and functions
Technical specifications
Outline and installation dimensions
unit in mm
Selection and ordering data
Cat, No. Rating (Amps) Designation Wiring
DiagramIP
Rating3SWH1203SWH1323SWH1453SWH1633SWH2203SWH2323SWH2453SWH2633SWH3203SWH3323SWH3453SWH3633SWH4203SWH4323SWH4453SWH463
IP66
IP66
IP66
IP66
20A32A45A63A20A32A45A63A20A32A45A63A20A32A45A63A
Single Pole
Double Pole
Triple Pole
Four Pole
E NL1
L2E N
ENL1
NL2E
E NL5L3L1
L6L4L2E N
ENL5L3L1
NL6L4L2E
16
21
38
80
16
21
38
80
8780
72
62
2-106 www.sassin.com
Mod
ular
Dev
ices
Single Phase Metal Distribution BoxesSeries 3SD22
3SD Distribution systerm is suitable for the Circuit of AC 50/60Hz, rated voltage up to the AC 660V, rated current up to the 125A of distributing control of modern buliding such as large office mansion, hotel, commerce department, industrial and mining enterprise and so on. It can protect electric appliances from overload voltage &Current. It also can short and frequent switch ON/OFF under normal operating condition.
Functions
Selection and ordering data
TypeD2206D2208D2210D2212D2214D2216D2218D2220D2222
207±1.2243±1.2279±1.2315±1.2351±1.2387±1.2423±2.0459±2.0495±2.0
68
10121416182022
Number of module
148±1.2184±1.2220±1.2256±1.2292±1.2328±1.2364±2.0400±2.0436±2.0
3SD22-63SD22-83SD22-103SD22-123SD22-143SD22-163SD22-183SD22-203SD22-22
Type code Order code173251732617327173281732917330173311733217333
Outline and installation dimensions
Technical Specifications
StandardBusbar ratingTinned Copper busbar to prevent corrosionRated shortcircuit withstandCapacityIPFlush mounted Main incomerIsolator current rating (A) Utilisation categoryInsulation voltage (V)Impulse Voltage (KA)Main IncomerCurrent rating (A)Sensitivity (mA)
IEC60439125A Used for Single phases circuit system
20KA for 200msec41
Modular isolator and RCCB
100A and 125A AC 22
5006
Residual Current Circuit Breaker (RCCB)100300
Outline Dimension (mm)A B
Unit in mmA
B
250±
2.5
200±
2.5
81±1.5
65±1.5
Incoming Devices
Moulded case circuit breaker Frame 1(x160); up to 160A, 18KAFrame 2(x250); 200A & 250A, 25KA
Moulded isolatorscurrent rating: 100A & 125A
Miniature circuit breakercurrent rating: 100A & 125Apull up & bi connect terminalsIP20 Protection
Outgoing Devices
Miniature circuit breaker current rating: UP to 50A B/C/D Curves for various application pull up & Bi connect terminals IP20 Protection
Residual current circuit breakerscurrent rating: 100AInbulit ON/OFF indicationInbulit earth leakage Indication
2-107www.sassin.com
Modular Devices
Three Phase Metal Distribution Boxes3SD23Series
Mod
ular
Dev
ices
Three Phase Metal Distribution BoxesSeries 3SD23
www.sassin.com2-108
Equipped with various modular electric for the function of terminal power distributionSuited for the installation of all Sassin individual modular devices MCCB, MCB, Isolator, RCCBUsed in residential building, non-residential building industry
Functions
Selection and ordering data
Number of way
D23 M04040D23 M04063D23 M04080D23 M04100D23 M04125D23 M04160D23 M04200D23 M06040D23 M06063D23 M06080D23 M06100D23 M06125D23 M06160D23 M06200D23 M06250D23 M08040D23 M08063D23 M08080D23 M08100D23 M08125D23 M08160D23 M08200D23 M08250D23 M10040D23 M10063D23 M10080D23 M10100D23 M10125D23 M10160D23 M10200D23 M10250
40A63A80A
100A125A160A200A40A63A80A
100A125A160A200A250A40A63A80A
100A125A160A200A250A40A63A80A
100A125A160A200A250A
Main Incomer rating
4
6
8
10
Type code Order code37996379973799837999380003800138002380033800438005380063800738008380093801038011380123801338014380153801638017380183801938020380213802238023380243802538026
Technical Specifications
StandardBuabar ratingTinned Copper Busbar to prevent corrosionRated shortcircuit withstand capacityIPFlush mountedMain IncomerOperation voltage (VAC)Frequency (Hz)Rated insulation voltage (VAC)Impluse voltage (KV)Electrical enduranceBreaking capacity
IEC 60439-3250A
20KA For 200msec41
MCCBup to 440
50/60690/800
810000 operation
Up to 160A incomer-18KA 200A & 250A incomer-25KA
Invicta distribution board with MCCB
Instruction of type code
Series code
D23
Main Incomer rating
Number of way: 04, 06, 08, 10, 12, 16, 18, 24
M 04 040
Main Incomer: (M, D, B, R) M-MCCB D-Isolator B-MCB R-RCCB
Modular Devices
Three Phase Metal Distribution Boxes3SD23Series
2-109www.sassin.com
Number of way
D23 M12040D23 M12063D23 M12080D23 M12100D23 M12125D23 M12160D23 M12200D23 M12250D23 M16040D23 M16063D23 M16080D23 M16100D23 M16125D23 M16160D23 M16200D23 M16250D23 M18100D23 M18125D23 M18160D23 M18200D23 M18250D23 M24100D23 M24125D23 M24160D23 M24200D23 M24250
40A63A80A
100A125A160A200A250A40A63A80A
100A125A160A200A250A100A125A160A200A250A100A125A160A200A250A
Main Incomer rating
12
16
18
24
Type code Order code3802738028380293803038031380323803338034380353803638037380383803938040380413804238043380443804538046380473804838049380503805138052
Technical Specifications
StandardBuabar ratingTinned Copper Busbar to prevent corrosionRated shortcircuit withstand capacityIPFlush mountedMain IncomerRated insulation voltage (VAC)Impluse voltage (KV)Current rating
IEC 60439125A
20KA For 200msec41
isolator500
6100A and 125A
Invicta distribution board with isolator
Selection and ordering data
Number of way
D23 D04100D23 D04125D23 D06100D23 D06125D23 D08100D23 D08125D23 D10100D23 D10125D23 D12100D23 D12125D23 D16100D23 D16125D23 D18100D23 D18125D23 D24100D23 D24125
100A125A100A125A100A125A100A125A100A125A100A125A100A125A100A125A
Main Incomer rating
4 6 8 10 12 16 18 24
Type code Order code38053 38054 38055 38056 38057 38058 38059 38060 38061 38062 38063 38064 38065 38066 38067 38068
Mod
ular
Dev
ices
Three Phase Metal Distribution BoxesSeries 3SD23
www.sassin.com2-110
Technical Specifications
Technical Specifications
StandardBuabar ratingTinned Copper Busbar to prevent corrosionRated shortcircuit withstand capacityIPFlush mountedMiniature IncomerBreaking capacityCurrent rating
StandardBuabar rating (A)Tinned Copper Busbar to prevent corrosionRated shortcircuit withstand capacityIPFlush mountedMain IncomerSensitivity (mA)Current rating (A)
IEC 60439125A
20KA For 200msec41
MCB6KA&10KA as per IEC60947-2
100A and 125A
IEC60439125A
20KA for 200msec41
RCCB300100
Invicta distribution board with MCB
Invicta distribution board with RCCB
Selection and ordering data
Selection and ordering data
Number of way
Number of way
D23 B04100D23 B04125D23 B06100D23 B06125D23 B08100D23 B08125D23 B10100D23 B10125D23 B12100D23 B12125D23 B16100D23 B16125D23 B18100D23 B18125D23 B24100D23 B24125
D23 R04100D23 R06100D23 R08100D23 R10100D23 R12100D23 R16100D23 R18100D23 R24100
100A125A100A125A100A125A100A125A100A125A100A125A100A125A100A125A
100A100A100A100A100A100A100A100A
Main Incomer rating
Main Incomer rating
4 6 8 10 12 16 18 24
4 6 8
10 12 16 18 24
Type code
Type code
Order code
Order code
38069 38070 38071 38072 38073 38074 38075 38076 38077 38078 38079 38080 38081 38082 38083 38084
38085 38086 38087 38088 38089 38090 38091 38092
Modular Devices
2-111www.sassin.com
Functions
Equipped with various modular electric for the function of terminal power distribution . Suited for the installation of all Sassin individual modular devices. (RCDs, MCBs, RCBO’s,Isolators etc). Used in residential building, non-residential building,industry.
Technical specifications
Standard: IEC60439-3Approval: CENumber of modules: 5, 8,12,15,18,24 for 3SHT
4,8,12,24 for 3SHARow : Single for 5,8,12,15,18 modules
Rated voltage In(A): 63Color: White The color of door: TransparentMounting type: SurfaceDegree of protection: IP54Material: ABS for body
PC for doorFire resistence: 650℃/30sAmbient temperature : (℃) -5 ~ +40,max. 95 % humidityStorage temperature( :℃) -40 ~+75
In(A)
Selection and ordering data Rated current
Order code Type code 58
10151824
3SHT surface mounting Number of module63 White Transparent
Two for 24 modules
In(A)Rated current
Order code Type code 48
121824
3SHA surface mounting Number of module63 White Transparent
IPIP54
IP54IP
HA04 30729HA08 30730HA12 30731HA18 30732HA24 30733
HT05HT08HT10HT15HT18Ht24
246052460624607246082460924610
Color of base
Color of door
Color of base
Color of door
Distribution BoxesSeries:3SHT & 3SHA
2-112 www.sassin.com
Mod
ular
Dev
ices
Technical Specifications
Selection and ordering data
3SD7N Surface mountingD7N1D7N2D7N4D7N8
White
Color of base Type code Order code
StandardApprovalModules (NO.)Mounting typeColorDegree of protectionMaterialFire resistanceAmbient temperature (℃)Storage temperature (℃)
IEC60529CE
1,2,4,8SurfaceWhiteIP30ABS
650℃/30s-5~+40, max. 95% humidity
-40~+75
36031360323603314973
Outline and installation dimensions
Number of module L(mm) W(mm) H(mm)
1248
405690
167.5
142142142145
65656565
63
Rated current In(A)
Outline Dimension (mm)
L
W
H
Terminal BoxSeries 3SD7N
2-113www.sassin.com
Modular Devices
Terminal Box
Technical specifications
Standard: IEC60529Approval: CEColor: White Degree of protection: IP65Material: ABS Fire resistence: 650℃/30sAmbient temperature : (℃) -5 +40, max. 95 % humidity~Storage temperature :(℃) -40 +75~
Selection and ordering data
Order code Type code Color of base
Color of cover Size (mm)
White White
Type
50X5080X5085X85X50100X100X70150X150X70150X110X70200X100X70200X155X80200X200X80255X200X80300X250X120400X350X120
Transparent
O
65X5085X80X60110X80X70100X100X70120X100X70150X110X70175X125X75175X125X100150X150X80200X100X80180X180X80200X155X100200X200X100250X200X100300X250X130400X350X130350X300X130
X55White GreyN
65X5085X80X60110X80X70100X100X70120X100X70150X110X70175X125X75175X125X100150X150X80200X100X80180X180X80200X155X100200X200X100
X55N
OBW5050OBW8050OBW858550OBW10010070OBW15011070OBW15015070OBW20010070OBW20015580OBW20020080OBW25520080OBW300250120OBW400350120
297892979029791297922979329794297952979629797297982979929800
NBW655055NBW858060NBW1108070NBW10010070NBW12010070NBW15011070NBW17512575NBW175125100NBW15015080NBW20010080NBW18018080NBW200155100NBW200200100NBW250200100NBW300250130NBW400350130NBW350300130
2980129802298032980429805298062980729808298092981029811298122981329814298152981629817
NBT655055NBT858060NBT1108070NBT10010070NBT12010070NBT15011070NBT17512575NBT175125100NBT15015080NBT20010080NBT18018080NBT200155100NBT200200100
24587245882458924590245912459224593245942459524596245972459824599
White
2-114 www.sassin.com
Mod
ular
Dev
ices
Discription Type code Order code
Discription Type code Order code
Selection and ordering data
PIN type
Busbar systemsSuitable for cutting
Connection type Phases Rated current (A) Length(cm) Type code Order code
PIN typePIN typePIN typeFork typeFork typeFork typeFork type
1×54 632×273×184×141×542×273×184×14
63636363636363
100 SA-BB101100100100100100100100E nd caps
For 1p
For 4p
For 2pFor 3p
Shock-protection caps
Discription Phases Type code Order code
yellow
Feeder terminals
2Connection capacity: 6-25mmMax. electrical load: 63 AMax. tightening torque 2 Nm
Din rails
Dimmension:Length:100cmAluminum
2Connection capacity: 6-25mmMax. electrical load: 63 AMax. tightening torque 2 Nm
Dimmension:Length:100cmIron plated zinc
SA-BB201SA-BB301SA-BB401SA-BB102SA-BB202SA-BB302SA-BB402
247602476224764247662476124763247652476732676326773267832679
SA-BBSCY5 32680
SA-BBEC1SA-BBEC2SA-BBEC3SA-BBEC4
FT1B 32929
FT2G 32930
DR1 32931
DR2 32932
Din Rail Device Accessories
5 parts
2-115www.sassin.com
Modular Devices
Din Rail Device Accessories
Selection and ordering dataWay Rated Screw size Sectioncross Type code Order code
of brass (mm) current (A)3+1 4+16+16+28+19+110+213+220+4
636363636363636363
M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×
6 8×6 8×6 8×6 8×6 8×6 8×6 8×6 8×6 8×
3+1 4+16+16+28+19+110+213+220+4
100100100
M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×M4 7×
6 9×6 9×6 9×6 9×6 9×6 9×6 9×6 9×6 9×
100100100100100100
Terminal bars with screws
TBS0631TBS0641TBS0661TBS0662TBS0681TBS0691TBS06102TBS06132TBS06204TBS1031TBS1041TBS1061TBS1062TBS1081TBS1091TBS10102TBS10132TBS10204
329333293432935329363293732938329393294032941329423294332944329453294632947329483294932950
13+2
20+4
100
100
Way Rated current (A)
633+1
4+1
6+1
6+2
8+1
9+1
10+2
13+2
20+4
89.5
59.5
112
179.5
63
63
63
63
63
63
63
63
1003+1
4+1
6+1
6+2
8+1
9+1
10+2
100
100
100
100
100
100
2-116 www.sassin.com
Mod
ular
Dev
ices
Din Rail Device Accessories
Discription Application Type code Order code
Discription Type code Order code
Terminal blocksterminals with insulation holder for quick fastening onto DIN rails
Blanking platesMatched with distribution boxesfor device covers with materials of a thickness of 1 to 3 mm
width: 1 module = 17.5 mm, White
Padlock for MCBs and switchesPrevents unauthorised or dangerous operation of the operating lever. An adaptor makes it possible to blockthe operating lever when switched ON or OFF
3SB5,3SB52,3SB1-63N
3SB71, 3SB71Z
Way Rated Screw Installation Dimension Sectioncross Type code Order code of brass (mm) current (A)
100 6 9×6 9×6 9×6 9×6 9×6 9×
7810121315
100100100100100
size (mm) (mm) size35 7.5×35 7.5×35 7.5×35 7.5×35 7.5×35 7.5×
50 2157×2171.5×2184.5× 2191×21104×21
× M5 8×M5 8×
3SB1-125,
Red
M5 8×M5 8×M5 8×M5 8×
TBS1007TBS1008TBS1010TBS1012TBS1013TBS1015
329513295232953329543295532956
MBP1 32957
width: 0.5 module = 9 mm, White MBP2 32958
PL1 32959
PL2 32960
PL3 32961
PR
OD
UC
T C
AT
AL
OG
V 2
4.2
A
TEL: +86-21-50210890 50219970
FAX: +86-21-50217333
E-mail: sassin@sassin.com
Http: //www.sassin.com
No.2588 JINHAI RO D, PUDONG, SHANGHAI, CHINA 201209
SASSIN INTERNATIONAL ELECTRIC SHANGHAI CO.,LTD.
Specifications and technical date are subject to change without notice. Please contact us for any relevant information on ordering.
Modular Devices
top related