ROBERT A. TARDIF, P.E.ROBERT A. TARDIF, P.E. ADMINISTRATORADMINISTRATOR

SUBSURFACE SYSTEMS SUBSURFACE SYSTEMS BUREAUBUREAU

(603) (603) 271271--2902904 4 robert.tardif@des.nh.govrobert.tardif@des.nh.gov

TOPICSTOPICS

New ApplicationsRule Changes e-Permitting StatusOrganization Questions

New ApplicationsNew Applications

http://des.nh.gov/organization/divisions/watehttp://des.nh.gov/organization/divisions/wate r/ssb/index.htmr/ssb/index.htm

Subdivision of LotsSubdivision of LotsIndividual Sewage Disposal System Individual Sewage Disposal System (ISDS)(ISDS)WaiverWaiver

All applications submitted should be the All applications submitted should be the most recent version (12/01/2011)most recent version (12/01/2011)

RULE CHANGESRULE CHANGES

EnvEnv--Wq 1002.13 Wq 1002.13 ““CommercialCommercial””

–– Removed manufactured homes Removed manufactured homes –– Removed condominiums up to two unitsRemoved condominiums up to two units–– Now specifically excludes home officesNow specifically excludes home offices

EnvEnv--Wq 1002.75 Wq 1002.75 ““ResidenceResidence””

--Includes manufactured homes Includes manufactured homes --Includes condominiums up to two unitsIncludes condominiums up to two units--Includes home officesIncludes home offices

Env-Wq 1003.10 Repair or Replacement of Existing Residential

ISDS.- Removes exemption for replacement in-

kind-- Work is now allowed up to and including Work is now allowed up to and including

replacing the dreplacing the d--box without filing a permit box without filing a permit application with DES (e.g., replacing or application with DES (e.g., replacing or adding a vent, replacing a pump, replacing adding a vent, replacing a pump, replacing a tank)a tank)

Env-Wq 1003.06 Information Required for Replacement ISDS

Applications.

- The information previously required for a repair and replacement system is now required by rule for all replacement systems (e.g., number of structures served, type of appliances, type and size of old septic tank, etc.)

Env-Wq 1003.01 Preparation of Plans; Seals Required.

- For systems that require a P.E. stamp, the designer of record doesn’t have to be a designer/ P.E., but may partner with a designer/P.E. to stamp the plan.

EnvEnv--Wq 1004.06 Wq 1004.06 Inspection Inspection Required; Issuance of Operational Required; Issuance of Operational

ApprovalApproval..-- For phased construction, if the entire For phased construction, if the entire

project is not completed at the time of the project is not completed at the time of the initial inspection request, the plan must be initial inspection request, the plan must be amended to remove the structures not amended to remove the structures not built, prior to receiving operational built, prior to receiving operational approval. approval.

-- Those structures not built will require a Those structures not built will require a new CAnew CA

EnvEnv--Wq 1004.15 Wq 1004.15 Expansion, Expansion, Relocation, Remodeling, or Relocation, Remodeling, or

Replacement of Existing StructuresReplacement of Existing Structures..

EnvEnv--Wq 1008.05Wq 1008.05 Nitrate Setback to Property LinesNitrate Setback to Property Lines

GW FLOW

1500gpd

75’

38’

19’

38’

1500gpd

75’

38’

19’

38’

75’

150’

37’

75’

AGGREGATE FLOW

PROPERTY LINESETBACKSDETERMINED BY COMBININGFLOWS

FROM TABLE 1008-3FOR 1500 GPD

FROM TABLE 1008-3FOR 1500 GPD

FROM TABLE 1008-3FOR 3000 GPD

1500gpd

75’

38’

19’

38’

1500gpd

75’

38’

19’

38’

GW FLOW

PROPERTY LINE SETBACKSDETERMINED BY INDIVIDUALFLOWS

AGGREGATE FLOW

GW FLOW

1100gpd

55’

28’

14’

28’

450gpd

50’

25’

12’

25’

AGGREGATE FLOW

PROPERTY LINESETBACKSDETERMINED BY INDIVIDUALFLOWS

10’`

FROM TABLE 1008-3FOR 1100 GPD

FROM Env-Wq 1008.05(h)

FROM TABLE 1008-2

-- BOXES ARE A VERY SIMPLIFIED WAY BOXES ARE A VERY SIMPLIFIED WAY OF DETERMINING NITRATE PLUMES.OF DETERMINING NITRATE PLUMES.

-- EnvEnv--Wq 1008.05(e):Wq 1008.05(e):– If the applicant submits a hydrogeological

analysis of the property which shows that the requirements of Env-Wq 402 will be met, the minimum setback distances shall be reduced.

EnvEnv--Wq 1010 Wq 1010 Septic TanksSeptic Tanks-- 1,250 gallon minimum tank size. 1,250 gallon minimum tank size. -- Basement plumbing fixtures.Basement plumbing fixtures.-- The liquid depth in any singleThe liquid depth in any single-- or multior multi--

compartment septic tank that is not a ledge tank compartment septic tank that is not a ledge tank shall be 40 inches or more in each shall be 40 inches or more in each compartment.compartment.

-- The liquid depth in any singleThe liquid depth in any single-- or multior multi-- compartment ledge tank shall be 30 inches or compartment ledge tank shall be 30 inches or more in each compartment.more in each compartment.

-- NonNon--conforming tank allowance.conforming tank allowance.

Exemptions RSA 485Exemptions RSA 485--A:33A:33-- No plans and specifications shall be required No plans and specifications shall be required

-- whenever land is subdivided whenever land is subdivided andand-- the purpose of such subdivision is to correct or the purpose of such subdivision is to correct or

conform boundary lines conform boundary lines oror-- when land is exchanged between abutters and no when land is exchanged between abutters and no

building is contemplated on the exchanged land.building is contemplated on the exchanged land.Env-Wq 1003.15 Alteration of Subdivisions

After Approval.– (a) The plan for a subdivision approved by the

department shall be the final plan.– (b) For a subdivision, a new application shall be

submitted if any lot line changes, unless exempted by– RSA 485-A:33.

Env-Wq 1003.07 Applicant's Signature Required;

Certification of Accuracy

- If the application is submitted electronically, the use of the user log-on ID, password, and personal identification number (PIN) assigned to the permitted designer shall constitute the signature and agreement required

Env-Wq 1003.08 Owner's Signature Required.

- If the application is submitted electronically, the permitted designer shall submit a portable document format (PDF) copy of the statement required by (a), above, signed by the owner(s), with the application.

QUESTIONS?QUESTIONS?

RemindersReminders

Heavy secure cast coversHeavy secure cast covers when at gradewhen at grade

Plastic secure risers /coversPlastic secure risers /covers

Riser and cover examplesRiser and cover examples

Plastic vented Plastic vented ““TT”” with 24with 24”” openingopening

Waterproof flexible joint (boot)Waterproof flexible joint (boot)

Pipe PitchPipe Pitch

2222°° elbow corrects thiselbow corrects this

NHDES SUBSURFACE BUREAUNHDES SUBSURFACE BUREAU

ROBERT A. TARDIF, P.E.ROBERT A. TARDIF, P.E.–– ADMINISTRATORADMINISTRATOR–– SUBSURFACE SYSTEMS BUREAUSUBSURFACE SYSTEMS BUREAU–– (603) (603) 271271--2902904 4 robert.tardif@des.nh.govrobert.tardif@des.nh.gov

INSPECTORS

douglas.smith@des.nh.gov 893-3637john.baas@des.nh.gov 559-1511brenda.hayward@des.nh.gov 875-7730leonard.raposa@des.nh.gov 271-2182james.berg@des.nh.gov 863-3266frederick.treiss@des.nh.gov 466-5379stan.bomba@des.nh.gov 271-2916

REVIEWERSREVIEWERS

eric.thomas@des.nh.goveric.thomas@des.nh.gov 271271--29322932

stan.bomba@des.nh.govstan.bomba@des.nh.gov 271271--29312931

christopher.moore@des.nh.govchristopher.moore@des.nh.gov 271271--29172917

darren.king@des.nh.govdarren.king@des.nh.gov 271271--14881488

dawn.buker@des.nh.govdawn.buker@des.nh.gov 271271--14491449

COMPLIANCE COMPLIANCE

richard.deseve@des.nh.govrichard.deseve@des.nh.gov 271271--34423442

INFORMATION INFORMATION jojo--ann.mckenney@des.nh.govann.mckenney@des.nh.gov 271271--29242924

dexter.dragon@des.nh.govdexter.dragon@des.nh.gov 271271--26312631

top related