01/02
EXTREMELY HAZARDOUS
VERY HIGHLYHAZARDOUS
HIGHLYHAZARDOUS
HAZARDOUS
MODERATELYHAZARDOUS
LOWHAZARD
654321
< 0.1
0.1 – 1
1 – 10
10 – 100
100 – 1,000
1,000 – 5,000
µg/m3
1
1 – 10
10 – 100
100 – 1,000
1,000 – 10,000
> 10,000
µg/day
OEB Occupational Exposure Band
OELOccupational
ExposureLimit
ADEAcceptional Daily Exposure
1,000 – 5,000
µg/mg/m
Occupational
OEL
EXTREMELY HAZARDOUS
VERY HIGHLYHAZARDOUS
HIGHLYHAZARDOUS
HAZARDOUS
MODERATELYHAZARDOUS
LOWHAZARD
OEB
< 0.1
0.1 – 1
1 – 10
10 – 100
100 – 1,000
1
1 – 10
10 – 100
100 – 1,000
1,000 – 10,000
EXTREMELY HAZARDOUS
VERY HIGHLYHAZARDOUS
HAZARDOUS
HAZARDOUS
MODERATELYHAZARDOUS
HAZARD
< 0.1< 0.1
0.1 – 1
1 – 10
10 – 100
100 – 1,000
PRODUCT INFORMATION
GB
PI-C
ont.P
N-1
7678
/1 |
© R
EMB
E® K
erst
ing
| All
righ
ts re
serv
ed |
Valid
from
14.
05.2
018
| Sub
ject
to
tech
nica
l cha
nges
wit
hout
not
ice
OEB4. APPROVED. CERTIFIED. SAFE.
Sampling in the containment area presents users with major chal-lenges. On the one hand the system always must remain closed due to the toxic media it contains, on the other hand, it has to be opened for sampling. With its automated in-line sampling system, REMBE® Kersting offers maximum safety and ease, in order to increase efficiency in process management.
OperationWith the containment sampler sampling occurs using the Smart-Glide p* cup sampler. Sampling is transported through the sampling system. The point of withdrawal as well as the sample collection point are separated from the continuing process with pneumatic pinch valves. Their tightness has been tested according to DIN 12266-1 P12 leak rate A inclusive protocol. Because of the pressure in the testing intermediate chamber this pressure is monitored by a pressure transmitter – approved according to ATEX product line 2014/34/EU. The filter system for the pressure equalisation of the sample chamber is according to filter class H13. In addition the con-tainment sampler includes a compressed air storage with a safety circuit, in order to keep the pneumatic actuated pinch valves closed in case of a pressure drop. At the end of the sampling process the samples are captured in a collection hose with a length of 20m and packaged for secure transportation.* Details on SmartGlide p on p. 02
Your Benefits• No release of toxic substances.
• Maximum product protection.
• Guaranteed leak-tightness in the process.
• Sample size determined by cup size.
• Precise process management.
CONTAINMENT SAMPLER
Sampling of toxic media
You can find detailed information and contacts for the Containment Sampler on: www.rembe-kersting.comor contact us at: +49 2961 7405-300, info@rembe-kersting.de.
Certifi ed according to
PED and TA-Lu� .
Consulting. Engineering. Products. Service.
Product InformatIon
GB
PI-C
ont.P
N-1
7678
/1 |
© R
EMB
E® K
erst
ing
| All
righ
ts re
serv
ed |
Valid
from
14.
05.2
018
| Sub
ject
to
tech
nica
l cha
nges
wit
hout
not
ice
02/02
Technical data
Material | Stainless steel (product contact)
1.4404 / 1.4301
Material | Sealing (product contact)
FPM EPDM or PTFE
Max. permissible temperature60 °C 180 °C optional
Max. permissible operating pressure -20 mbar g up to 0,1 bar g at 200 °C
Approval
ATEX Zone 20/21 PED TA-Luft
Designs
TypeSample volume
[ml]Fill tube – Ø | DN
[mm]Connection | DN
[mm]Ejection ports | DN
[mm]
SmartGlide p mini
40
150 80
50 200
250
SmartGlide p mini GMP
40
150 80
50 200
250
SmartGlide p
160
250 125
50 300
350
SmartGlide p maxi
250
350 150
50 400
450
SmartGlide p [Cup Sampler]
Zur Heide 35 | 59929 Brilon, Germany | T +49 2961 7405-300 | F +49 2961 7405-349info@rembe-kersting.de | www.rembe-kersting.com
Application and operationThe SmartGlide is used to sample free-falling media inside drop tubes and drop shafts. To remove the medium the sample cup moves into the process and captures a defined amount of the medium – up to 250 ml* depending on the SmartGlide type. After retraction, the cup is tilted and the removed sample is dispensed into a preselected sample container such as the sample collection system LayFlat.* Type SmartGlide maxi