Call LTC on 65801142 to give loopback to confirm line status. If unable to get loopback check copper socket setup and routing.

Run Hyperterminal- Select COMM 1- Bits per sec - 115200- Flow Control - NoneClick OK button

File- Properties- Settings- Emulation - VT100

Username - userPassword - 1234

Main Menu- 2 Configuration- 1 Quick Setup- 1 Default Gateway - Default Gateway IP 10.10.10.2 or RAD IP ie (198.18.3.102 in WO)- Enter- 3 SavedEscape

- 2 Router Interface- Ethernet IP Address, press 'M' - 1 IP Address 10.10.10.1 or RAD IP (ie 198.18.3.101 in WO) - 2 Netmask 255.255.255.252Enter - 3 Save- E1 IP Address, press 'M' - 1 IP Address 198.18.3.98 (WAN in WO) - 2 Netmask 255.255.255.252Enter - 3 Save - 3 E1 Configuration - 8 Time Slot (Time Slot refer to Speed stated in WO. Each Time Slot is 64K)Escape

- 2 System - 1 Management - 4 Management Access (to check TELNET ACCESS is ENABLED)Escape

- 3 Physical Port - 1 Ethernet Status (to check 100 Base - TX Full Duplex)Escape

- 5 IP Router - 4 Default Gateway - 2 Default Gateway IP 10.10.10.2 or RAD IP (ie 198.18.3.102 in WO)Escape- Transparent IP - 2 Gateway - 10.10.10.2 or RAD IP (ie 198.18.3.102 in WO)Escape

Main Menu- 4 Diagnostic1 Ping to 198.18.3.973 Start

Call Megapop on 64240700 to confirm circuit up and running.