January 8, 2013 #1 Pump Systems

Pump Systems for Septic Tanks

Float Settings, Timer Settings, Pumps, and Troubleshooting

Pumps Systems January 8, 2013 #2

The Septic Tank

Pumps Systems January 8, 2013 #3

Common Tank Types • 1,000 gal tank • 1,500 gal tank • 1,500 gal two-compartment ∼ Spill-over or baffled ∼ Flow through

Pumps Systems January 8, 2013 #4

Volume Measurements • Gallons per inch ∼ 1,000 gal tank ∼ 1,500 gal tank

• Measurements for different tanks

Pumps Systems January 8, 2013 #5

Pump Selection • Typical application types for residential systems ∼ Pump to “d-box” ∼ Pump to pressurized system

Pumps Systems January 8, 2013 #6

Pump Selection • System hydraulics ∼ Head loss ∼ Gallons per minute

• Selecting the right pump

Pumps Systems January 8, 2013 #7

Pump Selection

Pumps Systems January 8, 2013 #8

Pump Selection

Pumps Systems January 8, 2013 #9

Pump Selection • Select right pump for application • Note minimum liquid level

Pumps Systems January 8, 2013 #10

Float Switches • Operation ∼ Normally Opened vs. Normally Closed

• Types ∼ A: Normally Open, 1/8” Differential, Mercury ∼ T: Normally Closed, 1/8” Differential, Mercury

∼ B: Normally Open, 4” Differential (Typ.), Mechanical

Pumps Systems January 8, 2013 #11

Flow Modulation • Gravity septic tank • Demand dose vs. timed dose

Pumps Systems January 8, 2013 #12

Float Functions (Demand Dose) • High Water Alarm • Pump On or Pump On/Off • Pump Off • Redundant Off

Pumps Systems January 8, 2013 #13

Float Settings (Demand Dose) • Invert of inlet vs. outside top of tank • High Level Float • Pump On • Pump Off • Redundant Off • Pump Minimum Liquid Level • Local regulations (Oregon DEQ)

Pumps Systems January 8, 2013 #14

Timed Dose Advantages • Aerobic, unsaturated conditions ∼ Sand filters vs. drainfield ∼ Allows oxygen to move freely through media ∼ Complete control of dose

Pumps Systems January 8, 2013 #15

Float Functions (Timed Dose) • High-Level Water Alarm • Timer Override • Timer On/Off • Redundant Off

Pumps Systems January 8, 2013 #16

Float Settings (Timed Dose) • Surge Volume ∼ Determine daily flows from house ∼ Determine needed volume to accommodate ∼ Calculate “inches” in selected tank to match needed

surge volume

Pumps Systems January 8, 2013 #17

Float Settings (Timed Dose) • Invert of inlet vs. outside top of tank • High Water Alarm • Override Timer • Surge Volume • Timer On/Off • Redundant Off • Pump Minimum Liquid Level • Local Regulations (Oregon DEQ)

Pumps Systems January 8, 2013 #18

Timer Settings • Calculations ∼ Determine dose to drainfield

• Consult regulation • Be careful of “minimums” and “maximums”

∼ Determine flow rate of pump • Pump curve • Drawdown test

Pumps Systems January 8, 2013 #19

Timer Settings • Calculate “On” Time ∼ Dose vs. Flow Rate

• Calculate “Off” Time ∼ Doses Per Day

Pumps Systems January 8, 2013 #20

Timer Settings • Program panel ∼ Electromechanical ∼ PLC

Pumps Systems January 8, 2013 #21

Troubleshooting (Demand Dose) • Frequent alarms • Floats • Pump • Filter

Pumps Systems January 8, 2013 #22

Troubleshooting (Timed Dose) • Frequent alarms • Floats • Pump • Filter • Surge Volume

Pumps Systems January 8, 2013 #23

Conclusion • Successful systems must be set up correctly from start-up. • Timed dose systems work well if set up appropriately.