product presentation b ases of f ocal t herapy focal therapy rationale focal therapy represents the...

Post on 12-Jan-2016

223 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Product Presentation

BASES OF FOCAL THERAPY

Focal Therapy Rationale

• Focal therapy represents the perfect balance between Active Surveillance and Over-treatment

• Focal Therapy is the future of prostate cancer therapies

• Focal therapy relies on accurate imaging to target the area to be treated

• Focal Therapy needs controlled energy to treat the designated area

• Focal therapy needs precise tools to evaluate the treated area

1. Localization 2. Treatment 3. Validation

The 3 pillars of Focal Therapy

1. Localization 2. Treatment 3. Validation

The 3 pillars of Focal Therapy

Focal Imaging

• MR images reading

• Identification and Record of Tumors

• Image registration Software tools

1. Localization

1. Localization 2. Treatment 3. Validation

The 3 pillars of Focal Therapy

2. Treatment

Focal Treatment

• Position Accurately energy to be delivered

• Precise energy delivery

• Ability to follow precisely a contour

1. Localization 2. Treatment 3. Validation

The 3 pillars of Focal Therapy

3. Validation

Focal Control

• Immediate validation of effective treatment

• Compare effectively treated areas with planning

• Ability to complete treatment if necessary

1. Localization 2. Treatment 3. Validation

The 3 pillars of Focal Treatment

ALL IN ONE DEVICE

Focal-One Value Proposition

is

EVOLUTIONR

• Focal Treatment is the future of prostate cancer therapies… TODAY

• Focal•One is the first therapeutical device dedicated to Focal Therapy

• Focal•One brings Imaging, Therapy, and Validation into a single device

FOCAL

PRODUCT DESCRIPTION

Focal•One Principles

• Pre-treatment imaging• MRI Import (from CD/DVD or PACS)

• MRI fusion with Focal-One RTUS

• Targeting of areas identified on the MRI

• Treatment Process• Precise treatment area contouring

• Accurate Dynamic Focusing HIFU

• Post-treatment imaging• Contrast Ultrasound Imaging

• Treatment Completion option

PRE-TREATMENT IMAGING

Pre-treatment planning

1- MRI

• Import MRI images from CD/DVD/PACS (Dicom)

• Edit Contour of Prostate and Target areas

• Load previously defined contour• Start contouring on Focal•One

Pre-treatment planning

2- Real-time Ultrasound Volume

• Acquire Ultrasound Volume

• Edit Contour of Prostate

Pre-treatment planning

3- MRI / Ultrasound elastic fusion

• Automatic registration of 3D contours of prostate (3D translations and rotations)

• Elastic deformation of the MRI volume to match Ultrasound contours

• Transformation applied to MRI target areas to be visualized in the ultrasound referential

+

TREATMENT PROCESS

Pre-treatment planning

Treatment Area Planning

• Precise contouring of the area to be treated

• Automatic dispatch of individual lesions

Focal•One Dynamic Focusing Probe

• 8 focal points from 32mm to 67mm ( f = 5 mm)△

• Unitary HIFU lesion stacking

• Shooting process : 1s ON /foci ; no OFF

• Unitary HIFU lesion height = 5mm

• Max Reachable depth (A-P Distance): 40 mm

Dynamic focusing treatment

• 16 isocentric rings = 16 ways• Equal surfaces• Electronic displacement of focal point• Natural focal point @ 60 mm

Pre-treatment planning

Treatment tracking

• Ability to pause at any time during the process

• Modify planning of slice being treated

• Ability to update the planning of upcoming slices

• Review the patient information (baseline, biopsy reports, etc…) without stopping the treatment

• Track the progress of the overall treatment with virtual 3D prostate

TREATMENT VALIDATION

Contrast-Enhanced Ultrasound

Treated area validation

• Use of standard Contrast-Enhanced Ultrasound Technology

• Allows to confirm de-vascularized area

• Allows to re-treat areas not completely treated

PRODUCT OFFERING

Configurations and Options

Dual Touch-Screen Interface Dynamic Focusing Probe Internal B-K UltraView MRI images import from CD/DVD/PACS

(DICOM 3.0) Automatic elastic Fusion between MRI and

Ultrasound

FOCAL•ONE

Contrast Imaging Ultrasound

CONTRAST OPTION

FOCAL•ONE DESIGN CONCEPT

Patient Positioning

• Use of the OR table

Surgeon position

Transport Position

top related