product approval
Post on 18-Dec-2021
6 Views
Preview:
TRANSCRIPT
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Product ApprovalUSER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL8787-R7Application Type RevisionCode Version 2014Application Status Approved
CommentsArchived
Product Manufacturer Kawneer Company, Inc.Address/Phone/Email 555 Guthridge Court
Norcross, GA 30092(770) 840-6426tanya.dolby@alcoa.com
Authorized Signature Tanya Dolbytanya.dolby@alcoa.com
Technical Representative Tanya A. DolbyAddress/Phone/Email 555 Guthridge Court
Norcross, GA 30092(770) 840-6426tanya.dolby@alcoa.com
Quality Assurance Representative Mr. Scott NearAddress/Phone/Email 500 East 12th Street
Bloomsburg, PA 17815(570) 784-8000scott.near@alcoa.com
Category Panel WallsSubcategory Storefronts
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report
W. W. Schaefer
Florida License PE-44135Quality Assurance Entity Architectural Testing, Inc.Quality Assurance Contract Expiration Date 12/31/2018Validated By Terrence E. Lunn, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL8787_R7_COI_Certification of independence.pdf
Referenced Standard and Year (of Standard) Standard YearAAMA 501 2005ASTM E1886 2005ASTM E1996 2006ASTM E1996 2009ASTM E283 2004ASTM E330 2002ASTM E331 2000TAS 201/202/203 1994
Reviewed for CodeCompliance
PRBD20171039731
Equivalence of Product StandardsCertified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/28/2016Date Validated 10/31/2016Date Pending FBC Approval 11/02/2016Date Approved 12/14/2016
Summary of Products
FL # Model, Number or Name Description
8787.1 IR500 - LMI IR500 Aluminum Storefront System
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: N/AOther: Storefront size, pressure, assembly and installation
requirements are to be as specified in the attached drawing No. 1633. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This storefront system is rated as a wind zone 4 missile level "D" large missile impact product. All glass meets the requirements of the current ASTM EI300 standard.
Installation InstructionsFL8787_R7_II_Drawing 1633.pdf Verified By: W.W. Schaefer, P.E. 44135 Created by Independent Third Party: YesEvaluation ReportsFL8787_R7_AE_Evaluation report WWS-309.pdf Created by Independent Third Party: Yes
8787.2 IR501 - LMI IR501 Aluminum Storefront System
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +65/-65Other: Storefront size, assembly and installation
requirements are to be as specified in the attached drawing No. 1461. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This storefront system is rated as a wind zone 4 missile level "D" large missile impact product. All glass meets the requirements of the current ASTM E1300 standard.
Installation InstructionsFL8787_R7_II_Drawing 1461.pdf Verified By: W.W. Schaefer, P.E. 44135 Created by Independent Third Party: YesEvaluation ReportsFL8787_R7_AE_Evaluation report WWS-305.pdf Created by Independent Third Party: Yes
8787.3 IR501 - SMI IR501 Aluminum Storefront System
Limits of UseApproved for use in HVHZ: YesApproved for use outside HVHZ: YesImpact Resistant: YesDesign Pressure: +65/-65Other: Storefront size, assembly and installation
requirements are to be as specified in the attached drawing No. 1484. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This storefront system is rated as a small missile impact product. All glass meets the requirements of the current ASTM E1300 standard.
Installation InstructionsFL8787_R7_II_Drawing 1484.pdf Verified By: W.W. Schaefer, P.E. 44135 Created by Independent Third Party: YesEvaluation ReportsFL8787_R7_AE_Evaluation report WWS-306.pdf Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
Reviewed for CodeCompliance
PRBD20171039731
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
Reviewed for CodeCompliance
PRBD20171039731
W. W. Schaefer Engineering & Consulting, P.A. (CA #6809)7480 150th Court North
Palm Beach Gardens, FL 33418
Phone (561)744-3424
ENGINEER'S EVALUATION REPORT #WWS-305
Prepared for:
Kawneer Company, Inc.555 Guthridge CourtNorcross, GA 30092Phone: 770-449-5555
Prepared by:
Warren W. Schaefer, P.E.Florida Professional Engineer #44135
Manufacturer: Kawneer Company, Inc.
Product Category: Storefront
Evaluation Method: 1-D (Engineer's evaluation)
Product model & name: IR501 LMI Aluminum Store Front system
Documents that must accompany this report:
1. W. W. Schaefer Engineering & Consulting drawing No. 1461
Storefront size restrictions and assembly requirements:
See drawing No. 1461
Maximum allowable design pressure:
See drawing No. 1461
Installation requirements:
See drawing No. 1461
Code compliance:Code section(s) considered with this evaluation:
FBC Chapters 17 &24
Mullions:
Mullion conditions stated in this approval have been tested in accordance with TAS-201,202 & 203, ASTM E330, ASTM E1886 & ASTM E1996 andmeet the requirements ofFBC.
Glass:
All glass meets the current ASTM E1300 standard.
Test Standards applicable to the testing ofthis storefront system:
1
Reviewed for CodeCompliance
PRBD20171039731
TAS-201,202 & 203, ASTM E330, ASTM E331, ASTM E283, ASTM E1886, ASTME1996 & AAMA 501
Test Laboratory: Intertek Architectural Testing, Inc. (Previously named Hurricane TestLaboratory, Inc.)
Test report numbers: G049-0201-08, G049-0303-07, G049-1201-05 & G049-0111-06Note: All HVHZ test reports have been signed & sealed by a Florida PE.
General report notes & system limitations:1. All size & installation conditions shown in this report and the referenced drawing No.
1461 are based off the referenced test reports and/or engineering analysis in accordancewith the Florida Building Code.
2. Storefront systems shall be constructed in accordance with the descriptions in this report,and the manufacturer's state approved quality assurance entity specifications.
3. This product is approved for use in & outside of the High Velocity Hurricane Zones(HVHZ).
4. Job required design wind pressure shall be calculated in accordance with the FloridaBuilding Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and OtherStructures (0.85 directionality factor may apply per the current ASCE 7 standard).
5. These storefront systems are large missile impact rated for use in wind zone 4 & missilelevel "D" locations and need not be shuttered.
6. Dry glazing gaskets are in accordance with ASTM C864 or ASTM C509 per FBCchapter 24.
Ouality Assurance Entit¥: Architectural Testing, Inc.A
Warr*(W. Schaefer, P.E.Flortla P.E. #44135
f
JUN 27 2016
009%0!1880##:,2>_ts W. 80/944
43.43>,:"L,CE/Vs;... Eal;S f No. 44135'\
-
*
3'*\ STATE oF : *S' 4 %•-LORIOF..•" 2
2
Reviewed for CodeCompliance
PRBD20171039731