TRANSDUCERS
2
Why we’re here today?
• To learn a technical subject ( the content) in English (the language)
• Because there is no other way to learn a language than listening and talking
• Because 90% of technical literature is in English• Because we’d like you to be competitive with
European students of your age
3
Some friendly reminders
• From now till the end of this presentation we will talk in English only!
• I will speak in plain English and slowly but I won’t speak in Italian/English and neither in English/Italian!
• Questions are most welcome … if they are simple!
4
prepared by g.bancale
4
What is a transducer ?(a fairly good definition)
A transducer is a device which transforms a non-electrical
physical quantity (i.e. temperature, sound or light) into an
electrical signal (i.e. voltage, current, capacity…)
5
Where are they used and what for?• Antenna: is the most basic transducer and can be made from a simple
piece of wire. It converts electromagnetic energy into electricity when it receives signals and does the opposite when it transmits
• Strain gauges: have a long thin wire attached to a foil backing which is glued to an object. When the object changes shape, the strain gauge also changes shape and its resistance changes. The amount of stress or strain in the object is calculated from this change in resistance
• Accelerometer: which converts the change in position of mass into an electrical signal. Accelerometers measure the force of acceleration and deceleration. They are used in car airbags, stability control, hard drives, and many electronic gadgets.
6
…more• Geiger counter: detects radiation levels by using a transducer called a
Geiger-Muller tube
• Microphone and Speaker. Microphones convert sound pressure waves into electrical current, while speaker convert electrical current into sound pressure waves.
• And many many others
7
prepared by g.bancale
7
electrical signal
non-electrical physical quantity
8
prepared by g.bancale
8
What is its structureA transducer is made of three blocks:o Input I/Fo Sensoro Output I/F
InputI/F sensor Output
I/F
Transducer
9
prepared by g.bancale
9
Where does it fit in the DAQ
Transducer Conditioning +filtering A/DSampling P
Control logic
10
prepared by g.bancale
10
Important parameters of a transducer
• Static response: how does it respond to slowly variable signals, is it precise and accurate
• Dynamic response: how does it respond to quickly variable signals (bandwidth of control system, tr, ts !!!)
• Environmental factors: how these factors are affecting transducer performance
• Reliability: MTBF
11
prepared by g.bancale
11
Precision Accuracy
Precise
not accurate
Not precise
accuratePrecise
+ accurate
Not precise
not accurate
12
prepared by g.bancale
12
TRANSDUCERS
• Temperature transducers▫ Thermocouples▫ Resistance - Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
13
prepared by g.bancale
13
TRANSDUCERS
• Temperature transducers▫ Thermocouples ▫ Resistance - Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
14
prepared by g.bancale
14
What is a Thermocouple It’s a temperature sensitive device which works thanks to the Seebeck effect:“a voltage is generated in a circuit containing two different metals by keeping the junctions between them at different temperatures”
Estonian physician Thomas Seebeck (1770–1831)
15
prepared by g.bancale
15
Pros and Cons in temperature measuring using Thermocouples• Pros▫ They are inexpensive. ▫ They are rugged and reliable. ▫ They can be used over a wide temperature range.
• Cons▫ low output voltage▫ low sensitivity▫ non-linearity▫ electrical connections.
16
prepared by g.bancale
16
How does a thermocouple look like ?
Here it is!
please note the two wires (of two different metals) joined in the
junction.
17
prepared by g.bancale
17
How does a thermocouple work ?
High impedance voltmeter !
18
prepared by g.bancale
18
In normal operation, cold junction is placed in an ice bath
19
prepared by g.bancale
19
What types of thermocouples can we have ?
temp. range (°C)
• Type K : Chromel - Alumel -270 / 1370• Type J : Iron-Constantan -210 / 1050• Type E : Chromel -Constantan -270 / 790• Type N : Nicros -Nisil -260 / 1300• Type T : Copper-Constantan -270 / 400
It is important to note that thermocouples measure the temperature difference between two points, not absolute temperature
20
More features:• Type K ‘General Purpose' and low cost thermocouple, very popular
• Type J Limited range (-40 to +750°C), less popular than type K.
• Type E High output (68 mV/°C) well suited to low temperature (cryogenic) use
• Type N High stability and resistance to high temperature oxidation, designed as an 'improved' type K, it’s becoming more popular.
• Type T They are used for moist or sub-zero temperature monitoring applications because of superior corrosion resistance
21
Alloys used:
• Constantan: 55% Copper and 45% Nickel• Cromel: 90% Ni + 10% Cr• Alumel: 95% Ni + 2% Mn + 2% Al + 1% Silicon• Nicrosil: 14.4%Cr +1.4 Silicon + 0.1% Mn + Ni• Nisil: same as Nicrosil but different %
How much are thermocouples ?• Type K Thermocouple (Exposed wire, fiberglass insulated) Tip
Diameter: 1.5 mm Tip Temperature: -60 to +350 °C Price $9.90
• Type K Thermocouple (Insertion Probe) Tip Diameter: 3.3 mm Tip Temperature: -50 to +250 °C Price $39.60
25
prepared by g.bancale
25
Magnitude of thermal EMFThe temperature is usually expressed as a polynomial function ofthe measured voltage. Sometimes it is possible to get a decent linear approximation over a limited temperature range.
wherec and k = constants of the thermocouple materialsT1 = the temperature of the ‘hot’ junctionT2 = the temperature of the ‘cold’ or ‘reference’ junction
)()( 22
2121 TTkTTcE
26
27
prepared by g.bancale
27
Measurement circuit: issuesWe would like DVM to read only V1, but the voltmeter created two more metallic junctions: J2 and J3 voltmeter reading V will be proportional to the temperature difference between J1 and J2 we cannot find the temperature at J1 unless we first find the temperature of J2.
28
prepared by g.bancale
28
29
prepared by g.bancale
29
The circuit will provide accurate readings, but it is desirable to eliminate the ice bath
30
prepared by g.bancale
30One way to do this is to replace the ice bath with another isothermal block
directly measures the temperature of the isothermal block (the reference junction) and use that informationto compute the unknown temperature
Cu Fe C CCu
31
prepared by g.bancale
31
Last but not least: reference junction compensation circuit
The AD580 is a three-terminal, low cost, temperature compensated,voltage reference which provides a fixed 2.5 V output for inputs between 4.5 V and 30 V.
AD590 is an integrated-circuit temperature transducer which produces an output current proportional to absolute temperature.The device acts as a high impedance constant current regulator, passing 1µA/oK for supply voltages between +4V and +30V
32
prepared by g.bancale
32
Thermocouple - applications
• Thermocouples are most suitable for measuring over a large temperature range, up to 1800 K.
• They are less suitable for applications where smaller temperature differences need to be measured with high accuracy, for example the range 0–100 °C with 0.1 °C accuracy. For such applications, Thermistors and RTD’s are more suitable.
33
prepared by g.bancale
33
TRANSDUCERS
• Temperature transducers▫ Thermocouples ▫ Resistance - Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
34
prepared by g.bancale
34
Resistance temperature detectors (RTDs)
RTDs are temperature sensors that exploit the predictable change in electrical resistance of some materials with changing temperature.
Temperature Metal Resistance
The resistance ideally changes linearly with temp.
Principle of operationRTDs are manufactured from metals whose
resistance increases with temperature.Within a limited temperature range, this
resistivity increases linearly with temperature:
where:Rt = resistance at temperature tR0= resistance at a standard temperature t0
= temperature coefficient of resistance (°C-1)
PRTs ( platinum RTDs )
• They are the most popular RTD type• Nearly linear over a wide range of temperatures• Small enough to have response times of a
fraction of a second• They are among the most precise temperature
sensors available with resolution and measurement uncertainties of ±0.1 °C or better
Why Platinum
• Chemical stability
• Availability in a pure form
• Highly reproducible electrical properties
• Platinum probes will read 100Ω at 0°C and at 100°C the
DIN grade (i.e. pure platinum intentionally contaminated with other platinum group
metals) platinum RTD will read 138.5Ω
• Only platinum RTDs have an international standard ( =
0.00385 Ω/Ω/°C )
How does an RTD look like ?
• Usually they are provided encapsulated in probes
• They have an external indicator, controller or transmitter, or enclosed inside other devices where they measure temperature as a part of the device's function (i.e. temperature controller, precision thermostat... )
…more
• price $ 65.00 • Temperature Range: -200 to 260°C • High-Accuracy• Platinum Elements •3-Wire Construction Standard, 2 and 4-Wire Constructions Available
• Wall mount transducer• Temperature, Temperature/Humidity and Barometric Pressure Transmitter Models• Low-Cost Miniature DesignStylish Design Blends in well with Your Office, Computer Room or Laboratory Décor• $46.00 Wall mount RTD sensor
Pros and Cons in temperature measuring using RTDsPros• stable output for long period of time• ease of recalibration• accurate readings over relatively narrow
temperature ranges
…more
Cons (compared to thermocouples)• Smaller overall temperature range• Higher initial cost • Less rugged in high vibration environments• Active devices requiring an electrical current to
produce a voltage drop across the sensor that can be then measured by a calibrated read-out device
42
prepared by g.bancale
42
Platinum
Copper
TungstenNickel
43
prepared by g.bancale
43
Construction of a PRTs
• The coiled element sensor, made by inserting the helical sensing wires into a packed powder-filled insulating mandrel, provides a strain-free sensing element.
• All work is done manually under a microscope.• Strain-free elements required for industrial measurements below –200°C.•They also insure superior interchangeability and stability to the highest temp.
…more
•The thin film sensing element is made by depositing a thin layer of platinum in a resistance pattern on a ceramic substrate.•A glassy layer is applied for seal and protection.
Specifications
• Wiring configuration (2, 3, or 4-wire)• Self-heating• Stability• Repeatability• Response time
A. Wiring ConfigurationSerious lead-wire resistance errors for2/wire RTD especially in a 100Ω sensor.
• If lead wire resistance remains constant, it can be offset and not affect the temperature measurement.
• If ambient temperature conditions change, the wire resistance will also change, introducing errors. If the wire is very long, this source of error could be significant.
• Two-wire RTDs are typically used only with very short lead wires, or with a 1000Ω element.
B. Wiring ConfigurationIn a 3-wire RTD, there are 3 leads coming fromthe RTD instead of 2. L1 and L3 carry themeasuring current, while L2 acts only as apotential lead. Ideally, the resistances of L1 and L3are equal and therefore canceled. The resistance inR3 is equal to the resistance of the sensor Rt at agiven temperature—usually the beginning of thetemperature range. At this point, V out = zero. Asthe temperature of the sensor increases, theresistance of the sensor increases, causing theresistance to be out of balance and indicated at Vout. Resistances L1 and L3 in leads up to tens offeet long usually match well enough for 100 ohmthree-wire RTDs.
(L1+L2+Rt)xR2=R1x(L2+L3+R3)
But: L1=L3 therefore:
(L3+L2+Rt)xR2=R1x(L3+L2+R3)
Self-Heating• To measure resistance, it is necessary to pass a current
through the RTD• The resultant voltage drop across the resistor heats the
device ( Joule heating )• The sensor's indicated temperature is therefore slightly
higher than the actual temperature• The amount of self-heating also depends heavily on the
medium in which the RTD is immersed. An RTD can self-heat up to 100x higher in still air than in moving water, so self-heating specifications are just a conservative guide.
Stability• Sensor’s ability to maintain a consistent output when a
constant input is applied.• Unintended physical or thermal shocks can cause small,
one-time shifts. The material that the platinum is adhered to, when wound on a mandrel or deposited on a substrate, can expand and contract differentially to cause strain incorporated in normal performance but not cause shifts.
• The stability of platinum RTDs is exceptional, with most experiencing drift rates < 0.05°C over five years.
Repeatability
• Sensor’s ability to give the same output or reading under repeated identical conditions
• Absolute accuracy is not necessary in most applications. The focus should be on the stability and repeatability of the sensor (i.e. if an RTD in a 100.00°C bath consistently reads 100.06°C, the electronics can easily compensate for this error)
Response Time• Sensor's ability to react to a change in temperature, and
depends on the sensor's thermal mass and heat transfer from the material being tested
• Surface RTDs respond quickly to surface temperature change
• RTD specifications will list the sensor's time constant, which is the time it takes for an RTD to respond to a step change in temperature and come to 63% of its final equilibrium value.
52
prepared by g.bancale
52
TRANSDUCERS
• Temperature transducers▫ Thermocouples ▫ Resistance - Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
53
prepared by g.bancale
53
Milestones of ThermistorsTHERMal resISTORS
• 1833: negative temperature coefficient of silver sulphide was first observed by M. Faraday
• Before 2003 only ceramic materials (a mix of different metal oxides) were used for production of Thermistors
• After 2003 AdSem started manufacturing of Si and Ge high temperature NTC Thermistors with better performance than any ceramic NTC Thermistors
Types• NTC - Negative Temperature Coefficient, used
mostly in temperature sensing
Temperature semiconductor resistance
• PTC - Positive Temperature Coefficient, used
mostly in electric current control
• Symbol
Key features• the change in electrical resistance when subjected to a
corresponding change in body temperature is▫ Predictable▫ Precise ▫ Stable
• extremely high temperature coefficient of resistance• typical temperature range of -100° to over +600° F• Thermistors are generally accepted to be the most advantageous
sensor for many applications including temperature measurement and control.
THERMISTOR APPLICATIONS
And…
And…
And…
And
How they look like
How they look like
63
prepared by g.bancale
63
Thermistor
Semiconductor Temp. Sensors• The ordinary semiconductor diode may be used as a
temperature sensor • The forward biased voltage across a diode has a
temperature coefficient of about 2.3mV/°C and is reasonably linear
• The bias current should be held as constant as possible using constant current source, or a resistor from a stable voltage source
…more• If two identical transistors are operated at different but
constant collector current densities, then the difference in their base-emitter voltages is proportional to the absolute temperature of the transistors
• The transistor sensor is used in diode mode by connecting the base and collector together.
• VBE changes by approx. -2.2 mV/C°• The result is a sensor
very low power sensitive linear but electrically and mechanically delicate
IC temperature sensors• The AD590 and the LM35 have traditionally
been the most popular devices, but over the last few years better alternatives have become available.
• They provide a current or voltage output signal with relatively low output impedance
• Require an excitation power source and are essentially linear
AD590:Product Description•The AD590 is a two-terminal integrated circuit temperature transducer• produces an output current proportional to absolute temperature(1µA/K which means 298.2 µA 298.2K (25°C)
•The AD590 should be used in any temperature sensing application below 150°C• low cost • Linearization circuitry, precision voltage amplifiers, resistance measuring circuitry and cold junction compensation are not needed in applying the AD590•The AD590 is particularly useful in remote sensing applications. The device is insensitive to voltage drops over long lines due to its high impedance current output.
LM 35:Product Description• Calibrated directly in ° Celsius +10.0 mV/°C
• Rated for full -55° to +150°C range
• Suitable for remote applications
• Low cost due to wafer-level trimming
• Operates from 4 to 30 volts
• Low self-heating, 0.08°C in still air
• Nonlinearity only ±¼°C typical
• Low impedance output, 0.1 Ohm for 1 mA load
Price: Qty 1K+ $0.73
71
prepared by g.bancale
71
TRANSDUCER
• Temperature transducers▫ Thermocouples▫ Resistance-Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
72
prepared by g.bancale
72
Resistive position transducersDistance
Electrical signal
Principle of operation of an RPT• The principle of the resistive position transducer is that
the measured quantity (i.e. the position of an object, or the distance it has moved) causes a resistance change in the sensing element.
• One type of displacement transducer uses a resistance element with a sliding contact linked to the object being monitored.
• Thus the resistance between the slider and one end of the resistance element depends on the position of the object.
74
prepared by g.bancale
74
Resistive position transducers
21
2
RRR
EEout
…more • The output voltage depends on the wiper
position and therefore is a function of the shaft position.
• The output voltage Eout is a fraction of E, depending on the position of the wiper.
• The element is considered perfectly linear if the resistance of the transducer is distributed uniformly along the length of travel of wiper.
77
prepared by g.bancale
77
TRANSDUCER
• Temperature transducers▫ Thermocouples▫ Resistance-Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
78
prepared by g.bancale
78
Displacement transducers
• Capacitive transducer
• Inductive transducer
• Variable inductance transducer
79
prepared by g.bancale
79
Capacitive transducers• The capacitance of a parallel-plate capacitor is
given by
• ε = dielectric constantεo = 8.854 x 1o-12, in farad per meterA = the area of the plate, in square meterd = the plate spacing in meters
• Since C is inversely proportional to d, any change in d will cause a change in C.
dAC o
80
prepared by g.bancale
80
Capacitive transducers – physical design
81
prepared by g.bancale
81
Inductive transducers (IT)
• Inductive Transducers may be either
▫ Self - generating type transducers
▫ Passive type transducers.
Self-Generating IT• Self-Generating IT utilises the basic electrical
generator principle that: when there is relative motion between conductor and magnetic field, a voltage is induced in the conductor.
• An example of this is Tachometer that directly converts speeds or velocity into an electrical signal.
Tachometers• Examples of a Common Tachometer
84
prepared by g.bancale
84
IT– tachometer with a PM stator
85
prepared by g.bancale
85
IT– tachometer with a PM rotor
Passive type IT (LVDT)• Passive inductive transducers require an
external source of power.• The Differential transformer is a passive
inductive transformer, well known as Linear Variable Differential Transformer (LVDT).
• It consists basically of a primary winding and two secondary windings, wound over a hollow tube and positioned so that the primary is between two of its secondaries.
Linear Variable Differential Transformer (LVDT)• Some examples of LVDTs.
Linear Variable Differential Transformer • An example of LVDT electrical wiring.
Linear Variable Differential Transformer
• An iron core slides within the tube and therefore affects the magnetic coupling between the primary and two secondaries.
• When the core is in the centre , the voltage induced in the two secondaries is equal.
• When the core is moved in one direction of centre, the voltage induced in one winding is increased and that in the other is decreased. Movement in the opposite direction reverses this effects.
Linear Variable Differential Transformer• In next figure, the winding
is connected ‘series opposing’-that is the polarities of V1 and V2 oppose each other
• Consequently, when the core is in the center so that V1=V2, there is no voltage output, Vo = 0V.
91
prepared by g.bancale
91
Linear Variable Differential Transformer
• When the core is moved in one direction from the center, the voltage induced in one winding is increased and that in the others is decreased.
• Movement in the opposite direction reverse the effect.
92
prepared by g.bancale
92
Variable Inductance Transducers –operation
Core at the centerV1 = V2
Vo = 0
93
prepared by g.bancale
93
Variable Inductance Transducers –operation
Core moves towards S1V1 > V2
Vo increase
94
prepared by g.bancale
94
Variable Inductance Transducers –operation
Core moves towards S2V2 > V1
Vo decrease
95
prepared by g.bancale
95
Variable Inductance Transducers –operationThus, the amplitude of Vo is
a function of distance the core has moved. If the core is attached to a moving object, the LVDT output voltage can be a measure of the position of the object. The farther the core moves from the centre, the greater the difference in value between V1 and V2, and consequently the greater the value of Vo.
Advantages of LVDT• It produces a high output voltages for small
changes in core position.• Low cost • Solid and robust - capable of working in a wide
variety of environments. • No permanent damage to the LVDT if
measurements exceed the designed range.
97
prepared by g.bancale
97
TRANSDUCER
• Temperature transducers▫ Thermocouples▫ Resistance-Temperature Detectors (RTD)▫ Thermistors
• Resistive position transducers• Displacement transducers• Strain gauge
Strain gauge• The Strain Gauge is an example of a passive
transducer that uses electrical resistance variation in wires to sense the strain produced by a force on the wire.
• It is a very versatile detector and transducer for measuring weight, pressure, mechanical force or displacement.
Strain gauge: how they look likeThe construction of a bonded strain gauge shows a fine wire looped back and forth on a mounting plate, which is usually cemented to the element that undergoing stress.
100
prepared by g.bancale
100
Strain gauge
From the equation of resistance,
R = resistanceρ = specific resistance of the conductor materialL = the length of the conductor in metersA = the area of the conductor in square metersWhen a strain produced by a force is applied on
the wires, L increase and A decrease.
ALR
101
prepared by g.bancale
101
Strain gauge
L increase A decrease
From the equation of resistance,
R increaseALR
102
prepared by g.bancale
102
Strain gauge – the gauge factor
LLRRK
//
K = the gauge factorR = the initial resistance in ohms (without strain)ΔR = the change of initial resistance in ohmsL = the initial length in meters (without strain)ΔL = the change of initial length in meters
103
prepared by g.bancale
103
Strain gauge – the gauge factor
LLRRK
//
104
prepared by g.bancale
104
Strain gauge – the gauge factor
GRRK /
For many common materials, there is a constant ratio between stress and strain. Stress is defined as the internal force per unit area.
S = the stress in kilograms per square meterF = the force in kilogramsA = the area in square meters
105
prepared by g.bancale
105
Stress equation
AFS
106
prepared by g.bancale
106
Young’s modulus
The constant of proportionality between stress and strain for the curve is known as the modulus of elasticity of the materials
E = Young’s modulus in kilograms per square meter
S = the stress in kilograms per square meterG = the strain (no unit)
GSE
Measuring Circuits
Measuring Circuits
Application & Installation• The output of a strain gage circuit is a very low-level voltage signal
requiring a sensitivity of 100 microvolts or better.• The low level of the signal makes it particularly susceptible to
unwanted noise from other electrical devices.• Capacitive coupling caused by the lead wires' running too close to
AC power cables or ground currents are potential error sources in strain measurement.
• Other error sources may include magnetically induced voltages when the lead wires pass through variable magnetic fields, parasitic (unwanted) contact resistances of lead wires, insulation failure, and thermocouple effects at the junction of dissimilar metals. The sum of such interferences can result in significant signal degradation.
Evaluation test on Transducers Name………………………………………………………….. 5a CE Thursday, 5th March 2009
1. where does a transducer fit in the DAQ (i.e. Data AcQuisition)
2. two important parameters of a transducer are Static and Dynamic response. Can you
explain the difference between these two?
3. explain the principle of operation of a thermocouple
4. are thermocouples suitable for heavy industrial applications? Why?
5. why should you use an ice bath when measuring temperature with a thermocouple?
6. explain the principle of operation of RTD’s
7. are RTD’s and specifically PRT’s precise temperature sensors?
8. how can you minimize lead - wire resistance errors for RTD
9. an ordinary semiconductor diode may be used as a temperature sensor, can you explain
how?
10. LM35 is by far the most popular temperature sensor among students. Can you remember
why?
11. explain the principle of operation of a resistive position transducer
12. LVDT’s (Linear Variable Differential Transformer) are passive type inductive displacement
transducers. Can you explain how they work?
13. what can you measure with a strain gauge?
14. what is the equation that explains the operation of a strain gauge
15. the gauge factor is indicated as K in the following formula. Can you tell the meaning of the
terms which appear in the formula?
LLRRK
//
ΔΔ
= Please note that:
• all answers must be in English, answers in Italian will not be evaluated • you are free to use drawings to better explain your answers • all questions have the same weight, so in order to have a sufficient score you have to
provide correct answers to 9 questions • you are not allowed to use any book or material with related information, you are allowed to
use English dictionary
top related