pre-demolition asbestos and lead survey report
Post on 18-Dec-2021
7 Views
Preview:
TRANSCRIPT
www.forensicanalytical.com Forensic Analytical Consulting Services
May 3, 2021
Pre-demolition Asbestos and Lead Survey Report
City of Piedmont Community Pool and Carriage House 777 & 799 Magnolia Avenue Piedmont, California 94611 Prepared for: Daniel Gonzales City of Piedmont Public Works Director 120 Vista Avenue Piedmont, California 94611 Prepared By:
Karina Garcia Forensic Analytical Consulting Services 21228 Cabot Blvd. Hayward, CA 94545 510-266-4600 | kgarcia@forensicanalytical.com FACS Project #PJ62195
www.forensicanalytical.com Forensic Analytical Consulting Services
Contents Executive Summary ................................................................................................................................ 1
Introduction ............................................................................................................................................... 2
Site Characterization ............................................................................................................................... 2
Scope of Work .......................................................................................................................................... 2
Asbestos Survey Methodology ............................................................................................................ 2
Lead Survey Methodology ..................................................................................................................... 3
Findings and Recommendations ......................................................................................................... 3
Asbestos Regulations ............................................................................................................................ 7
Lead Regulations and Guidelines ....................................................................................................... 9
Limitations ............................................................................................................................................... 10
Appendix A: Results Summary Tables and Laboratory Analytical Reports Appendix B: Sample Location Diagram Appendix C: CDPH Form Appendix D: FACS Personnel Certifications
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
1 of 11
Executive Summary Forensic Analytical Consulting Services, Inc. (FACS) conducted a comprehensive asbestos-containing material identification survey and a lead-containing paint identification survey of the City of Piedmont Community Pool and Carriage House in Piedmont, California on March 12th, and 16th, 2021. Asbestos was detected in the Pool House roof flashing. Lead was reported in the Pool House green metal louvres, white concrete footing, gray metal rails, white gypsum wallboard walls, white metal pipes, green wood beams, white wood ceilings, white wood walls, off-white ceramic wall tiles, and tan with wavy pattern wall tiles, in the wading pool light blue ceramic wall tiles, in the main pool sample of white and black ceramic floor tiles, the Carriage House red concrete floor, white concrete walls/footing, white wood walls, white wood ceilings, white wood doors, red wood stairs, tan wood walls, cream stucco walls, cream concrete walls/footing, and brown wood windowsills. A more complete discussion of findings, conclusions, and recommendations is provided below.
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
2 of 11
Introduction The City of Piedmont retained Forensic Analytical Consulting Services, Inc. (FACS) to perform a comprehensive asbestos-containing materials (ACM) and lead-containing paint identification survey for the Community Pool and Carriage House in Piedmont, California. The survey was performed on March 12th and 16th, 2021 to identify the asbestos and lead content of materials and paint that would be impacted by demolition of the subject buildings. The FACS project management team consisted of Karina Garcia, Associate Project Manager, and Dave Brinkerhoff, Local Director. Ms. Garcia is a California Department of Public Health (CDPH) Certified Lead Sampling Technician (CDPH LRC-00003109) and Mr. Brinkerhoff is a California Division of Occupational Safety and Health (Cal/OSHA) Certified Asbestos Consultant (CAC 16-5645) and a CDPH Certified Inspector/Assessor (CDPH LRC-00002772). Mark Torres, Miguel Coyotl, and Anthony Aguilar conducted the site survey. Mr. Torres is a Cal/OSHA Certified Asbestos Consultant (CAC 18-6369) and a CDPH Certified Inspector/Assessor (CDPH LRC-00000582). Mr. Aguilar is a Cal/OSHA Certified Site Surveillance Technician (CSST 19-6525) and a CDPH Certified Sampling Technician (CDPH LRC-00001334). Mr. Coyotl is a Cal/OSHA Certified Site Surveillance Technician (CSST 18-6253) and a CDPH Certified Sampling Technician (CDPH LRC-00003703). FACS employee certifications are included in Appendix D. Site Characterization The two project buildings consisted of a one-story wood framed Pool House, and a two-story wood framed residence. The interior of the Pool House consisted primarily of painted wood and gypsum board walls, the floors were ceramic tile and concrete, and a painted wood ceiling. The roof of the Pool House was rolled roofing. There is a wood shed adjacent to the Pool House with a composite shingle roof. The interior of the Carriage House consisted primarily of painted wood and concrete walls, the floors were painted wood and concrete, and painted wood ceilings. Demolition is planned for the structures. Scope of Work FACS’ scope of work included a comprehensive bulk asbestos and lead paint survey, laboratory sample analyses, and report generation. This report contains the findings and recommendations from our inspection and the analytical results of samples submitted for laboratory analysis. The purpose of the survey was to identify, sample, and analyze suspect ACM and suspect lead-containing paint that may be disturbed in demolition of the subject buildings, within the limitations described below. Asbestos Survey Methodology Performing an asbestos survey prior to commencement of any demolition and renovation is regulated by the local air quality district. In the San Francisco Bay Area, an asbestos survey is required regardless of the building’s construction date. This asbestos survey was performed in accordance with the Bay Area Air Quality Management District (BAAQMD) Regulation 11, Rule 2. BAAQMD and Cal/OSHA recognize material with more than one percent (1%) asbestos to be ACM. However, Cal/OSHA also requires notification and registration of the contractor when working with materials containing more than one-tenth of one percent (0.1%) asbestos, and requires worker protection and specified work practices whenever materials containing any detectable levels of asbestos are to be disturbed. Our investigation consisted of the following:
• Visual inspection;
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
3 of 11
• Collection of samples of suspect ACM using the AHERA Survey protocol; • Submitting samples to SGS Forensic Laboratories, Inc. (SGSFL) located in Hayward, California
for analysis by Polarized Light Microscopy (PLM). SGSFL is accredited by the American Industrial Hygiene Association (AIHA) and by the NIST National Volunteer Laboratory Accreditation Program (NVLAP) for asbestos sample analysis; and
• Presenting analytical results, conclusions, and recommendations in a report that can be submitted to the BAAQMD.
The types, number, and locations of samples were determined based on available information about the subject project provided to FACS, visual observations, regulatory requirements, and other project management considerations. Lead Survey Methodology This survey was conducted by paint chip sampling. The lead survey was intended to assist with compliance with Cal/OSHA worker protection requirements. The lead survey was not a comprehensive lead-based paint survey as detailed in the "Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing" by The National Center for Lead-Safe Housing for HUD. Paint containing lead greater than 0.5% lead by weight (or 5,000 ppm) is considered lead-based paint (LBP) by CDPH and the Environmental Protection Agency (EPA), which regulate the disturbance of LBP. Paint with any detectable level of lead is considered lead-containing paint by Cal/OSHA and is regulated under Title 8 California Code of Regulations (CCR) Section 1532.1, Lead in Construction Standard. Since this paint chip survey sampled only representative components and not every individual component, the lead results are assumed to be the same on like components in the same general area of the representative component that was sampled. The paint chip samples were collected using a sharp scraper to remove all layers of paint down to the substrate material, taking care not to include the substrate in the sample. The detection limit is determined by factors including the size and matrix of each individual sample. Our investigation consisted of the following:
• Visual inspection; • Collection of samples of suspect lead-containing paint; • Submitting samples to SGSFL for analysis by atomic absorption spectrometry (Flame AAS) in
accordance with EPA Methods 3050B and 7000B. SGSFL is accredited by the AIHA Environmental Lead Laboratory Accreditation Program (ELLAP) and by the CDPH for lead analysis; and
• Presenting analytical results, conclusions, and recommendations in a report. The types, number, and locations of samples were determined based on available information about the subject project provided to FACS, visual observations, regulatory requirements, and other project management considerations. Findings and Recommendations Asbestos Survey Results The table below presents a summary of the asbestos findings for each of the homogeneous materials sampled in this survey.
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
4 of 11
Table 1. Asbestos Survey Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Material Location Asbestos Content Regulatory Classification Quantity
Wallboard/Joint compound
Pool House: office, chemical storage room, men’s and women’s locker
rooms, employee locker room
White drywall: ND White joint compound: ND
Paint: ND NA NA
Stucco Pool House: exterior Grey cementitious material: ND Tan cementitious material: ND
Paint: ND NA NA
Rolled roofing Pool House: roof
Tan fibrous material: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Stones: ND
NA NA
Off-white penetration mastic Pool House: roof Off-white mastic: ND Black semi-fibrous tar: ND NA NA
Roof flashing Pool House: roof
Stones: ND Black tar: ND Black felt: ND Stones: ND
Black tar: ND Black felt: ND Black tar: ND
Black felt: 20% Chrysotile Black tar: ND
CAT 1 60sf
Flange gasket Pool House:
chemical storage room 8” pipe
Black non-fibrous material: ND NA NA
2” white ceramic floor tile, grout, and mortar Pool House: office
White ceramic tile: ND White grout: ND
Brown mortar: ND NA NA
4” off-white ceramic wall tile Pool House: office
men’s and women’s locker rooms
Off-white ceramic tile: ND White grout: ND Grey mortar: ND
NA NA
Gray floor coating Pool House: men’s and women’s locker
rooms floor Grey coating: ND NA NA
4” tan ceramic wall tile, grout and mortar
Pool House: women’s locker room
Tan ceramic tile: ND Tan grout: ND
Grey mortar: ND NA NA
Concrete pad floor Pool House:
chemical storage floor
Grey cementitious material: ND NA NA
Exterior pavement Pool House: exterior floor
Grey/brown cementitious material: ND NA NA
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
5 of 11
Table 1. Asbestos Survey Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Material Location Asbestos Content Regulatory Classification Quantity
Off-white expansion joint Pool House: exterior pavement sections Grey non-fibrous material: ND NA NA
Concrete building footing Pool House: building footing Grey cementitious material: ND NA NA
Asphalt Pool House: asphalt road to south building Black cementitious material: ND NA NA
CMU wall Pool House: exterior of north building Grey cementitious material: ND NA NA
4” blue ceramic wall tile, grout, and mortar Pools
Light blue ceramic tile: ND White grout: ND Grey mortar: ND
NA NA
Vapor barrier Pool House: pool equipment room Brown fibrous material: ND NA NA
Duct tape
Pool House: chemical shed furnace, pool
equipment room
Black tar foil: ND Clear adhesive: ND NA NA
Roof shingle/felt Pool House: chemical shed roof
Stones: ND Black roof shingle: ND
Stones: ND Black roof shingle: ND
Black felt: ND
NA NA
Particle board paper Pool House: chemical shed ceiling Tan paper: ND NA NA
White HVAC mastic Pool House: pool house roof
White mastic: ND Black tar: ND NA NA
White flashing mastic Pool House: pool house lower roof
White mastic: ND Black non-fibrous material: ND NA NA
Concrete pad floor Carriage House: concrete pad
Grey cementitious material: ND Paint: ND NA NA
Concrete footing Carriage House: concrete flooring
Grey cementitious material: ND Paint: ND NA NA
Patterned vinyl flooring Carriage House: storage closet floor Tan sheet flooring: ND NA NA
Exterior stucco Carriage House: building exterior
Grey cementitious material: ND Paint: ND NA NA
Roof shingle and felt Carriage House: roof Brown roof shingle: ND Black felt: ND NA NA
Asphalt Carriage House: parking lot
Grey cementitious material: ND Paint: ND NA NA
Concrete panel Carriage House: building exterior,
upper panels Black cementitious tar: ND NA NA
Concrete retaining wall Carriage House:
north exterior retaining wall
Grey cementitious material: ND NA NA
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
6 of 11
Table 1. Asbestos Survey Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Material Location Asbestos Content Regulatory Classification Quantity
Abbreviations/Acronyms ND – No Asbestos Detected NA – Not Applicable SF – Square Feet LF – Linear Feet CAT 1 Nonfriable – Category 1 Nonfriable Asbestos-Containing Material Asbestos was detected in the following material collected for this survey:
• Roof flashing in Pool House roof These results apply to all locations where the materials listed above are present in the project areas, not just to the sample locations. A table summarizing the laboratory analytical results for each of the bulk samples collected and submitted for asbestos analysis can be found in Appendix A of this report. Samples containing less than 10% asbestos (including Trace) must be further analyzed using the point count method to determine asbestos content more accurately or else must be considered >1% asbestos (ACM). FACS recommends:
1. Develop a specification for removal of ACM prior to disturbance by construction activities. 2. If other suspect asbestos-containing materials not previously tested are uncovered during
construction activities, those materials must be assumed to contain asbestos or must be sampled accordingly prior to their disturbance.
Lead Survey Results The table below presents a summary of the lead findings for each of the paints sampled in this survey.
Material Location Lead Content White paint on stucco wall Pool House, exterior stucco walls <0.007 wt%
Green paint on wood beam Pool House, exterior wood panels, beams, exterior door and door frame 0.056 wt%
White paint on wood ceiling Pool House, exterior wood ceiling
overhang, exterior door ad door frame, chemical storage room, men’s and
women’s locker rooms 0.052 wt%
Green paint on metal louvre Pool House, exterior lower windows 0.26 wt% White paint on concrete footing Pool House, exterior concrete footing 0.010 wt%
Gray paint on metal rail Pool House, exterior guard rail 0.017 wt% White paint on gypsum
wallboard wall Pool House, chemical storage room,
wallboard 0.044 wt%
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
7 of 11
Material Location Lead Content
White paint on wood wall Pool House, chemical storage room, wood walls 0.065 wt%
White paint on metal pipe Pool House, chemical storage room, metal pipes 0.27 wt%
White ceramic floor tile Pool House, office, pools <7 mg/kg
Green paint on metal door Pool House, men’s and women’s locker rooms metal doors and door frames <0.006 wt%
Gray paint on concrete floor Pool House, men’s and women’s locker rooms floor <0.007 wt%
Off-white ceramic wall tile Pool House, office, men’s and women’s locker rooms 8 mg/kg
Tan with wavy pattern wall tile Pool House, women’s locker room 9 mg/kg Beige ceramic wall tile Pool House, women’s locker room <7 mg/kg
Black ceramic floor tile Wading pool, main pool <6 mg/kg
White ceramic floor tile Wading pool, main pool <7 mg/kg
Light blue ceramic wall tile Wading pool, main pool 610 mg/kg Green paint on wood wall trim Storage shed, wood wall <0.007 wt%
White paint on wood wall Storage shed, wood wall <0.007 wt%
Black paint on metal pole Fence adjacent to pool area <0.007 wt% White and black ceramic floor
tile Main pool 10 mg/kg
Red paint on concrete floor Carriage House, 1st floor, floor >0.5 wt%1
White paint on wood wall Carriage House, 1st floor, wooden walls 4.4 wt%
White paint on wood ceiling Carriage House, 1st floor, wooden ceiling rafters 4.3 wt%
White paint on concrete wall/footing Carriage House, 1st floor, concrete footing 0.020 wt%
White paint on wood door Carriage House, 1st floor, wooden door and door frames 21 wt%
Red paint on wood stairs Wooden stairs 14 wt%
Tan paint on wood wall Carriage House, 2nd floor storage rooms wooden walls and ceiling 25 wt%
Cream paint on stucco wall Carriage House, exterior stucco walls 7.1 wt% Cream paint on concrete
wall/footing Carriage House, exterior concrete footing 0.65 wt%
Brown paint on wood windowsill
Carriage House, wooden exterior beams/siding, windows and window
frames 9.1 wt%
Abbreviations/Acronyms wt.% – Percent by Weight
1 FACS was unable to obtain a proper paint sample without substrate due to the condition of the paint. Even though the result on the lab report is 0.37 wt%, there is the possibility of dilution due to the amount of substrate on the sample. FACS has taken a conservative approach and is treating it as >0.50 wt%.
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
8 of 11
A detectable concentration of lead was reported in the Pool House green metal louvres, white concrete footing, gray metal rails, white gypsum wallboard walls, white metal pipes, off-white ceramic wall tiles, tan with wavy pattern ceramic wall tiles, light blue ceramic wall tiles, in the main pool white and black ceramic floor tiles, and in the Carriage House red concrete floor, and white concrete walls/footing. In the Pool House, all green wooden beams, white wood ceilings, and white wood walls should be considered to be lead-based paint based on these results. In the Carriage House, all white wood walls, white wood ceilings, white wood doors, red wood stairs, tan wood walls, cream stucco walls, cream concrete walls/footings, and brown wood windowsills should be considered to be lead-based paint based on these results. As required by the California Department of Public Health, Title 17, Article 16 Regulations, dated April 20, 2008, FACS will forward Form 8552 to CDPH notifying them of the absence of LBP in the areas tested at the subject property. A copy of the Form 8552 is contained in Appendix C. FACS recommends:
1. Current Cal/OSHA regulations (e.g. 8CCR 1532.1 “Lead in Construction” Standard) apply to all construction work where an employee may be occupationally exposed to lead. Therefore any work performed on a surface containing any amount of lead must comply with this regulation.
2. Any paint not represented by a result that is below the analytical limit of detection should be considered to contain lead and be treated as such until proven otherwise.
3. If other suspect lead-containing materials and/or paint not previously tested are encountered during demolition activities, those materials and/or paint must be assumed to contain lead or must be sampled accordingly prior to their disturbance.
4. Building records should indicate that a complete lead hazard evaluation of the building was not performed. The lead paint sampling was limited to assisting with Cal/OSHA compliance during demolition activities.
Asbestos Regulations The following is a summary of some current regulations that contain requirements related to building surveys for asbestos, worker protection from asbestos exposure, and asbestos as a hazardous waste. These summaries are not intended to be all-inclusive and do not contain every aspect of the regulations discussed. For detailed regulatory requirements in specific situations, FACS may be consulted, and the applicable regulations should be examined. Building Survey US EPA National Emission Standard for Hazardous Air Pollutants (NESHAP), 40 CFR Part 61 and Bay Area Air Quality Management District (BAAQMD) Regulation 11 Rule 2 Under NESHAP’s regulation, no visible emissions are allowed during building demolition or renovation activities that involve regulated asbestos-containing materials (RACM). For this reason, all buildings must be surveyed for ACM prior to demolition or renovation. BAAQMD, which implements NESHAP, must be notified prior to any building demolition even if no ACM are present. BAAQMD must be notified of most renovation projects that disturb RACM. All RACM must be removed from a building prior to demolition. Any disturbance (removal) of RACM during renovation or demolition must be performed according to BAAQMD regulations. RACM is (a) friable ACM; (b) Category I non-friable ACM that has or will become friable; (c) Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading; or (d) Category II non-friable ACM that may become or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation.
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
9 of 11
Category I non-friable ACM are asbestos-containing packings, gaskets, resilient floor coverings, mastics, and asphalt roofing products. Category II non-friable ACM is any non-friable material not designated as Category I. Per BAAQMD, these products include transite board, pipe, and asbestos-cement products, plaster, stucco, and paint. Asbestos Hazard Emergency Response Act (AHERA), 40 CFR Part 763, Subpart E AHERA requires asbestos surveys and the development of Asbestos Management Plans for all of the nation's primary and secondary schools. The asbestos survey procedures of AHERA are considered the industry standard and are applied to all surveys performed by FACS unless otherwise specified. Samples are analyzed in accordance with EPA Method 600/R-93-116, using PLM with dispersion staining and visual area estimation to determine percent asbestos content. This method allows for identifying the primary types of asbestos used in building materials. All layers in a sample must be analyzed and reported separately. Samples (and layers of samples) containing <1 percent asbestos by PLM are reported as Trace. Samples containing <10 percent asbestos (including Trace) must be further analyzed using the point-count method to determine asbestos content more accurately or be considered >1 percent asbestos (ACM). Composite sampling, which may potentially reduce the total asbestos content of a material, is only permitted by EPA when sampling joint compound, tape, and gypsum wallboard according to Asbestos NESHAP Clarification Regarding Analysis of Multi-Layered Systems (40 CFR Part 61 FRL-4821-7). OSHA does not recognize composite sampling. Worker Protection California Assembly Bill AB3713, Health and Safety Code Division 20, Chapter 10.4, Section 25915-25924 Building owners, employers, lessees, etc., must notify tenants, employees, and contractors of the presence of asbestos in both friable and non-friable forms. Preventive maintenance activities must be developed and communicated to these parties. Notification is required 15 days after the identification of ACM and asbestos-containing construction materials (ACCM, >0.1 percent asbestos) in the building, and annually thereafter. Occupational Safety and Health Administration (OSHA) 29 CFR 1926.1101 and Cal/OSHA 8 CCR 1529 – Asbestos in Construction OSHA and Cal/OSHA require employers to implement specific work practices to protect workers from airborne asbestos exposure. Materials that contain any detectable amount of asbestos are regulated by OSHA and Cal/OSHA. Even building materials that contain low levels of asbestos (<1 percent) can potentially generate significant concentrations of airborne asbestos fibers when disturbed; therefore, control measures should be instituted that adequately address worker health and safety during planned renovation or demolition activities involving these materials. OSHA requires ACM to be categorized into Thermal System Insulation (TSI), Surfacing Materials, and ‘Other’ Materials for the purpose of determining job classification for abatement. TSI is ACM applied to pipes, fittings, boilers, breeching, tanks, ducts, or other structural components to prevent heat loss or gain. Surfacing Material is material that is sprayed, troweled, or otherwise applied to surfaces (such as acoustical plaster on ceilings; fireproofing materials on structural members; or other materials applied to surfaces for acoustical, fireproofing, and other purposes). ′Other′ materials are all ACM not categorized as TSI or Surfacing Material.
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
10 of 11
Hazardous Asbestos Waste US EPA National Emission Standard for Hazardous Air Pollutants (NESHAP), 40 CFR Part 61 and Bay Area Air Quality Management District (BAAQMD) Regulation 11 Rule 2 Hazardous waste in California is regulated by Cal/EPA, Division of Toxic Substances Control (DTSC). In California, friable ACM (>1 percent asbestos) waste is hazardous waste. EPA defines friable ACM waste as asbestos-containing waste but does not consider it to be “hazardous waste”. A waste site must be notified of the asbestos content of waste, including non-hazardous asbestos waste, prior to disposal. Lead Regulations and Guidelines The following is a summary of some current regulations that contain requirements related to worker protection from lead exposure and some regulations and guidelines related lead waste segregation, characterization, and disposal. These summaries are not intended to be all-inclusive and do not contain every aspect of the regulations discussed. For detailed regulatory requirements in specific situations, FACS may be consulted, and the applicable regulations should be examined. Worker Protection Cal/OSHA Lead in Construction Safety Standard (8 CCR 1532.1) The current Cal/OSHA Lead in Construction Safety Standard (8 CCR 1532.1) regulation applies to all construction work where an employee may be occupationally exposed to lead; therefore, work (including manual demolition, scraping, welding, etc.) performed on surfaces containing any detectable concentration of lead must comply with the standard, including exposure assessment monitoring (personal air sampling) to determine if the airborne lead exposure levels are within acceptable limits. For work involving a Cal/OSHA “trigger tasks” (such as sanding, cutting, torch cutting, etc.), workers must be protected during the initial exposure assessment, per the Cal/OSHA Lead Standard requirements, as if they were exposed above the Permissible Exposure Limit (PEL) until actual exposures are determined. With torch cutting, for example, this includes providing supplied air respiratory protection during the initial exposure assessment. Lead Waste Segregation, Characterization, and Disposal Loose and flaking paints should be scraped down to intact paint (and the resulting paint chips captured for disposal) prior to demolition. Only components with intact, well-adhered paint will then remain during demolition. The owner or removal/demolition contractor should conduct appropriate segregation of waste created during the removal or dismantling/demolition process and dispose of the different waste streams in accordance regulatory requirements based on appropriate testing results. Lead waste is considered a hazardous waste if the result of the Toxicity Characterization Leaching Procedure (TCLP) test exceeds 5 milligrams per liter (mg/l), under the Resource Conservation and Recovery Act (RCRA), 40 CFR 261, Appendix II. In California, a waste is also considered hazardous if the result of soluble lead content by a Waste Extraction Test (WET) is greater than 5 mg/l, or if the total lead content exceeds 1,000 milligrams per kilogram (mg/kg) in accordance with Title 22 of the CCR. When TTLC results are below 50 mg/kg, STLC/TCLP limits cannot be exceeded, so the waste is classified as general construction debris. Limitations The results of this survey do not apply beyond the planned demolition activities described above. Suspect asbestos- and lead-containing materials in areas not included in the scope of this survey should be assumed to be ACM and lead-containing, respectively, unless testing is conducted which determines
City of Piedmont Community Pool & Carriage House, Pre-Demo Asbestos and Lead Survey Report (5/03/2021)
www.forensicanalytical.com Forensic Analytical Consulting Services
11 of 11
otherwise. The lead paint sampling was limited only to Cal/OSHA compliance during demolition activities and is not considered to be a complete lead hazard evaluation. If revisions to the demolition project are made that impact additional materials or areas, FACS should be contacted to review the changes and/or to conduct additional survey work to address potential impact to untested materials. This investigation is limited to the conditions and practices observed and information made available to FACS. The methods, conclusions and recommendations provided are based on FACS’ judgment, expertise and the standard of practice for professional service. They are subject to the limitations and variability inherent in the methodology employed. As with all environmental investigations, this investigation is limited to the defined scope and does not purport to set forth all hazards, nor indicate that other hazards do not exist. Please do not hesitate to contact our offices at 510-266-4600 with any questions or concerns. Respectfully, Reviewed by: FORENSIC ANALYTICAL FORENSIC ANALYTICAL
Wilson Wong Associate Project Manager Senior Project Manager CDPH No. LRC-00003109 CAC No. # 92-0791 CDPH I/A No. 3659
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Appendix A Results Summary Tables and Laboratory Analytical Reports
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 3. Summary of Asbestos Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Asbestos Content Sample Location
A1 Wallboard/Joint compound White drywall: ND
White joint compound: ND Paint: ND
Chemical storage room, north wall
A2 Wallboard/Joint compound White drywall: ND
White joint compound: ND Paint: ND
Men’s locker room, east wall
A3 Wallboard/Joint compound White drywall: ND
White joint compound: ND Paint: ND
Employee locker room, north wall
A4 Stucco Grey cementitious material: ND Tan cementitious material: ND
Paint: ND Exterior, northwest corner
A5 Stucco Grey cementitious material: ND Tan cementitious material: ND
Paint: ND Exterior, north
A6 Stucco Grey cementitious material: ND Tan cementitious material: ND
Paint: ND Exterior, northeast
A7 Stucco Grey cementitious material: ND Tan cementitious material: ND
Paint: ND Exterior, southwest
A8 Stucco Grey cementitious material: ND Tan cementitious material: ND
Paint: ND Exterior, southeast
A9 Rolled roofing
Tan fibrous material: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Stones: ND
Pool house, lower roof, center
A10 Rolled roofing
Tan fibrous material: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Black tar: ND Black felt: ND Stones: ND
Pool house, upper roof, center
A11 Off-white penetration mastic Off-white mastic: ND Black semi-fibrous tar: ND
Pool house, upper roof, southwest
A12 Off-white penetration mastic Off-white mastic: ND Black semi-fibrous tar: ND Pool house, lower roof, south
A13 Roof flashing Stones: ND
Black tar: ND Black felt: ND Stones: ND
Pool house, upper roof, east
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 3. Summary of Asbestos Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Asbestos Content Sample Location
Black tar: ND Black felt: ND Black tar: ND
Black felt: 20% Chrysotile Black tar: ND
A14 Roof flashing
Stones: ND Black tar: ND Black felt: ND Stones: ND
Black tar: ND Black felt: ND Black tar: ND
Black felt: 20% Chrysotile Black tar: ND
Pool house, upper roof, west
A15 Flange gasket Black non-fibrous material: ND Chemical storage room, 8” flange
A16 Flange gasket Black non-fibrous material: ND Chemical storage room, 8” flange
A17 2” white ceramic floor tile, grout, and mortar
White ceramic tile: ND White grout: ND
Brown mortar: ND Office floor, west
A18 2” white ceramic floor tile, grout, and mortar
White ceramic tile: ND White grout: ND
Brown mortar: ND Office floor, east
A19 4” off-white ceramic wall tile Off-white ceramic tile: ND
White grout: ND Grey mortar: ND
Office, east wall
A20 4” off-white ceramic wall tile Off-white ceramic tile: ND
White grout: ND Grey mortar: ND
Men’s locker, center wall shower
A21 Gray floor coating Grey coating: ND Men’s locker room, floor
A22 Gray floor coating Grey coating: ND Women’s locker room, floor
A23 4” tan ceramic wall tile, grout, and mortar
Tan ceramic tile: ND Tan grout: ND
Grey mortar: ND Women’s locker room, south
A24 4” tan ceramic wall tile, grout, and mortar
White ceramic tile: ND White grout: ND Grey mortar: ND
Women’s locker room, north
A25 Concrete pad floor Grey cementitious material: ND Chemical storage room, floor
A26 Concrete pad floor Grey cementitious material: ND Employee locker room, floor
A27 Exterior pavement Grey/brown cementitious material: ND Exterior, north
A28 Exterior pavement Grey cementitious material: ND Exterior, south
A29 Off-white expansion joint Grey non-fibrous material: ND Exterior, north, at building
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 3. Summary of Asbestos Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Asbestos Content Sample Location
A30 Off-white expansion joint Grey non-fibrous material: ND Exterior, north, at pool
A31 Concrete building footing Grey cementitious material: ND Exterior, north side
A32 Concrete building footing Grey cementitious material: ND Exterior, south side
A33 Asphalt Black cementitious material: ND Exterior, east road, west side
A34 Asphalt Black cementitious material: ND Exterior, east road, east side
A35 CMU wall Grey cementitious material: ND Exterior, west of pool
A36 CMU wall Grey cementitious material: ND Exterior, west of pool
A37 4” blue ceramic wall tile, grout, and mortar
Light blue ceramic tile: ND White grout: ND Grey mortar: ND
East pool, wall
A38 4” blue ceramic wall tile, grout, and mortar
Light blue ceramic tile: ND White grout: ND Grey mortar: ND
East pool, floor
A39 Vapor barrier Brown fibrous material: ND Pool equipment room, north wall
A40 Vapor barrier Brown fibrous material: ND Pool equipment room, east wall
A41 Duct tape Black tar foil: ND Clear adhesive: ND Storage shed, furnace
A42 Duct tape Black tar foil: ND Clear adhesive: ND Pool equipment room, furnace
A43 Roofing shingle and felt
Stones: ND Black roof shingle: ND
Stones: ND Black roof shingle: ND
Black felt: ND
Storage shed, roof
A44 Roofing shingle and felt
Stones: ND Black roof shingle: ND
Stones: ND Black roof shingle: ND
Black felt: ND
Storage shed, roof
A45 Particle board paper Tan paper: ND Storage shed, ceiling
A46 Particle board paper Tan paper: ND Storage shed, ceiling
A47 White HVAC mastic White mastic: ND Black tar: ND Roof, west side
A48 White HVAC mastic White mastic: ND Roof, west side
A49 White flashing mastic White mastic: ND Black non-fibrous material: ND Lower roof, north side
A50 White flashing mastic White mastic: ND Black non-fibrous material: ND Lower roof, south side
CAR-A1 Concrete pad floor Grey cementitious material: ND Paint: ND
Carriage house, 1st floor, south area floor
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 3. Summary of Asbestos Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Asbestos Content Sample Location
CAR-A2 Concrete pad floor Grey cementitious material: ND Paint: ND
Carriage house, 1st floor, north area floor
CAR-A3 Concrete footing Grey cementitious material: ND Paint: ND
Carriage house , 1st floor, north area wall
CAR-A4 Concrete footing Grey cementitious material: ND Paint: ND
Carriage house, 1st floor, restroom, east wall
CAR-A5 Patterned vinyl flooring Tan sheet flooring: ND Carriage house, 2nd floor, storage room B closet
CAR-A6 Patterned vinyl flooring Tan sheet flooring: ND Carriage house, 2nd floor, storage room B closet
CAR-A7 Exterior stucco Grey cementitious material: ND Paint: ND
Carriage house, exterior, southeast wall
CAR-A8 Exterior stucco Grey cementitious material: ND Paint: ND
Carriage house, exterior, northeast wall
CAR-A9 Exterior stucco Grey cementitious material: ND Paint: ND
Carriage house, exterior northeast corner wall
CAR-A10 Exterior stucco Grey cementitious material: ND Paint: ND
Carriage house, exterior northwest corner wall
CAR-A11 Exterior stucco Grey cementitious material: ND Paint: ND
Carriage house, southeast column
CAR-A12 Roof shingle and felt Brown roof shingle: ND Black felt: ND Carriage house, northeast roof
CAR-A13 Roof shingle and felt Brown roof shingle: ND Black felt: ND Carriage house, northwest roof
CAR-A14 Concrete panel Grey cementitious material: ND Paint: ND
Carriage house, exterior east wall, south
CAR-A15 Concrete panel Grey cementitious material: ND Paint: ND
Carriage house, exterior east wall, center
CAR-A16 Concrete panel Grey cementitious material: ND Paint: ND
Carriage house, exterior east wall, north
CAR-A17 Asphalt Black cementitious tar: ND East parking lot
CAR-A18 Asphalt Black cementitious tar: ND South parking lot
CAR-A19 Concrete retaining wall Grey cementitious material: ND Northeast retaining wall
CAR-A20 Concrete retaining wall Grey cementitious material: ND Northwest retaining wall Analytical Method: Polarized Light Microscopy (PLM), EPA/600/R-93/116
ND = No Asbestos Detected
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 4. Summary of Lead Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Lead Content Sample Location
Pb1 White paint on stucco wall <0.007 wt% Pool house, exterior, northwest area outside office
Pb2 Green paint on wood beam 0.056 wt% Pool house, exterior, north
central area, outside women’s locker room
Pb3 White paint on wood ceiling 0.052 wt% Pool house, exterior, north
central area, outside women’s locker room
Pb4 Green paint on metal louvre 0.26 wt% Pool house, exterior, south
central area, adjacent to chemical storage room
Pb5 White paint on concrete footing 0.010 wt% Pool house, exterior, southwest area, lower south wall
Pb6 Gray paint on metal rail 0.017 wt% Pool house, exterior, southwest
area, adjacent to chemical storage room
Pb7 White paint on gypsum wallboard wall 0.044 wt%
Pool house, chemical storage room, north central area adjacent
to door
Pb8 White paint on wood wall 0.065 wt% Pool house, chemical storage room, central area wall, south
side
Pb9 White paint on metal pipe 0.27 wt% Pool house, chemical storage room, central area wall, south
side Pb10 White ceramic floor tile <7 mg/kg Pool house, office, southwest area
Pb11 Green paint on metal door <0.006 wt% Pool house, exterior, north central area, outside women’s locker room
Pb12 Gray paint on concrete floor <0.007 wt% Pool house, men’s locker room, southeast area, adjacent to shower
Pb13 Off-white ceramic wall tile 8 mg/kg Pool house, office, southwest area, adjacent to door
Pb14 Tan with wavy pattern wall tile 9 mg/kg Pool house, women’s locker room, southeast area
Pb15 Beige ceramic wall tile <7 mg/kg Pool house, women’s locker room, north central area
Pb16 Black ceramic floor tile <6 mg/kg Wading pool, exterior, northwest area in pool area
Pb17 White ceramic floor tile <7 mg/kg Wading pool, exterior, northwest area in pool area
Pb18 Light blue ceramic wall tile 610 mg/kg Wading pool, exterior, southwest area in pool area
Pb19 Green paint on wood wall trim <0.007 wt% Storage shed, exterior, northeast area
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix A
Table 4. Summary of Lead Analytical Results City of Piedmont
Community Pool and Carriage House Piedmont, CA
Sample Number Material Description Lead Content Sample Location
Pb20 White paint on wood wall <0.006 wt% Storage shed, exterior, northeast area
Pb21 Black paint on metal pole <0.007 wt% Between main pool area and wading pool area
Pb22 White and black ceramic floor tile 10 mg/kg Main pool area, exterior, north central area
CAR-Pb1 Red paint on concrete floor 3700 mg/kg Carriage house, 1st floor, south floor
CAR-Pb2 White paint on wood wall 4.4 wt% Carriage house,1st floor, east wall
CAR-Pb3 White paint on wood ceiling 4.3 wt% Carriage house,1st floor, north ceiling
CAR-Pb4 White paint on concrete wall/footing 0.020 wt% Carriage house,1st floor, bathroom wall, north
CAR-Pb5 White paint on wood door 21 wt% Carriage house,1st floor, bathroom door
CAR-Pb6 Red paint on wood stairs 14 wt% Carriage house, stairs floor
CAR-Pb7 Tan paint on wood wall 25 wt% Carriage house, 2nd floor, storage room, wall
CAR-Pb8 Cream paint on stucco wall 7.1 wt% Carriage house, exterior building, south wall
CAR-Pb9 Cream paint on concrete wall/footing 0.65 wt% Carriage house, exterior building, east wall
CAR-Pb10 Brown paint on wood windowsill 9.1 wt% Carriage house, exterior building, east windowsill
Analytical Method: EPA 3050B/EPA 7000B < = Below Analytical Limit of Detection
Final Report
(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation)Bulk Asbestos Analysis
NVLAP Lab Code: 101459-0HAY01Client ID:Forensic Analytical Consulting SvcsB315070Report Number:Mirna Garcia
Date Received:21228 Cabot Blvd.03/17/21Date Analyzed:03/18/21Date Printed:Hayward, CA 94545
First Reported:
HAY01PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
SGSFL Job ID:Job ID/Site:
Date(s) Collected: 03/12/202150Total Samples Submitted:
Total Samples Analyzed: 50
03/12/21
03/18/21
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A1 12398307Layer: White Drywall NDLayer: White Joint Compound NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (20 %) Fibrous Glass (10 %)
A2 12398308Layer: White Drywall NDLayer: White Joint Compound NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (20 %) Fibrous Glass (10 %)
A3 12398309Layer: White Drywall NDLayer: White Joint Compound NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (20 %) Fibrous Glass (10 %)
A4 12398310Layer: Grey Cementitious Material NDLayer: Tan Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A5 12398311Layer: Grey Cementitious Material NDLayer: Tan Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
1 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A6 12398312Layer: Grey Cementitious Material NDLayer: Tan Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A7 12398313Layer: Grey Cementitious Material NDLayer: Tan Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A8 12398314Layer: Grey Cementitious Material NDLayer: Tan Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A9 12398315Layer: Tan Fibrous Material NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt NDLayer: Stones ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (45 %) Fibrous Glass (5 %) Synthetic (10 %) Comment: Bulk complex sample.
A10 12398316Layer: Stones NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace) Fibrous Glass (10 %) Synthetic (35 %) Comment: Bulk complex sample.
2 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A11 12398317Layer: Off-White Mastic NDLayer: Black Semi-Fibrous Tar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (15 %)
A12 12398318Layer: Off-White Mastic NDLayer: Black Semi-Fibrous Tar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (15 %)
A13 12398319Layer: Stones NDLayer: Black Tar NDLayer: Black Felt NDLayer: Stones NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt Chrysotile 20 %Layer: Black Tar ND
Asbestos (4%)Total Composite Values of Fibrous Components:Cellulose (25 %) Synthetic (20 %) Comment: Bulk complex sample.
A14 12398320Layer: Stones NDLayer: Black Tar NDLayer: Black Felt NDLayer: Stones NDLayer: Black Tar NDLayer: Black Felt NDLayer: Black Tar NDLayer: Black Felt Chrysotile 20 %Layer: Black Tar ND
Asbestos (4%)Total Composite Values of Fibrous Components:Cellulose (10 %) Fibrous Glass (15 %) Synthetic (20 %) Comment: Bulk complex sample.
A15 12398321Layer: Black Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A16 12398322Layer: Black Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
3 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A17 12398323Layer: White Ceramic Tile NDLayer: White Grout NDLayer: Brown Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A18 12398324Layer: White Ceramic Tile NDLayer: White Grout NDLayer: Brown Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A19 12398325Layer: Off-White Ceramic Tile NDLayer: White Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A20 12398326Layer: Off-White Ceramic Tile NDLayer: White Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A21 12398327Layer: Grey Coating ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A22 12398328Layer: Grey Coating ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A23 12398329Layer: Tan Ceramic Tile NDLayer: Tan Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A24 12398330Layer: White Ceramic Tile NDLayer: White Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace) Synthetic (5 %)
4 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A25 12398331Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A26 12398332Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A27 12398333Layer: Grey/Brown Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A28 12398334Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A29 12398335Layer: Grey Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A30 12398336Layer: Grey Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A31 12398337Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A32 12398338Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A33 12398339Layer: Black Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A34 12398340Layer: Black Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
5 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A35 12398341Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A36 12398342Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A37 12398343Layer: Light Blue Ceramic Tile NDLayer: White Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A38 12398344Layer: Light Blue Ceramic Tile NDLayer: White Grout NDLayer: Grey Mortar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A39 12398345Layer: Brown Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (90 %)
A40 12398346Layer: Brown Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (90 %)
A41 12398347Layer: Black Tar Foil NDLayer: Clear Adhesive ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A42 12398348Layer: Black Tar Foil NDLayer: Clear Adhesive ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
6 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
A43 12398349Layer: Stones NDLayer: Black Roof Shingle NDLayer: Stones NDLayer: Black Roof Shingle NDLayer: Black Felt ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (10 %) Fibrous Glass (40 %)
A44 12398350Layer: Stones NDLayer: Black Roof Shingle NDLayer: Stones NDLayer: Black Roof Shingle NDLayer: Black Felt ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (10 %) Fibrous Glass (40 %)
A45 12398351Layer: Tan Paper ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (99 %)
A46 12398352Layer: Tan Paper ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (99 %)
A47 12398353Layer: White Mastic NDLayer: Black Tar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A48 12398354Layer: White Mastic ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A49 12398355Layer: White Mastic NDLayer: Black Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
A50 12398356Layer: White Mastic NDLayer: Black Non-Fibrous Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
7 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315070Date Printed: 03/18/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
Analytical results and reports are generated by SGS Forensic Laboratories (SGSFL) at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGSFL to any third party without prior written request from client. This report applies only to the sample(s) tested.Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGSFL. The client is solely responsiblefor theuse and interpretation of test results and reports requested from SGSFL. SGSFL is not able to assess the degree of hazard resulting from materials analyzed. SGS ForensicLaboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. All samples werereceived in acceptable condition unless otherwise noted.
Note: Limit of Quantification ('LOQ') = 1%. 'Trace' denotes the presence of asbestos below the LOQ. 'ND' = 'None Detected'.Tad Thrower, Laboratory Supervisor, Hayward Laboratory
8 of 83777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Final Report
(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation)Bulk Asbestos Analysis
NVLAP Lab Code: 101459-0HAY01Client ID:Forensic Analytical Consulting SvcsB315449Report Number:Mirna Garcia
Date Received:21228 Cabot Blvd.03/22/21Date Analyzed:03/23/21Date Printed:Hayward, CA 94545
First Reported:
HAY01PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
SGSFL Job ID:Job ID/Site:
Date(s) Collected: 03/12/202120Total Samples Submitted:
Total Samples Analyzed: 20
03/18/21
03/23/21
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
CAR-A1 12400982Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A2 12400983Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A3 12400984Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A4 12400985Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A5 12400986Layer: Tan Sheet Flooring ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A6 12400987Layer: Tan Sheet Flooring ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A7 12400988Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
1 of 33777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315449Date Printed: 03/23/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
CAR-A8 12400989Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A9 12400990Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A10 12400991Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A11 12400992Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A12 12400993Layer: Brown Roof Shingle NDLayer: Black Felt ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (10 %) Fibrous Glass (40 %)
CAR-A13 12400994Layer: Brown Roof Shingle NDLayer: Black Felt ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (10 %) Fibrous Glass (40 %)
CAR-A14 12400995Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A15 12400996Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
2 of 33777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Report Number: B315449Date Printed: 03/23/21Client Name: Forensic Analytical Consulting Svcs
Sample ID Lab NumberAsbestos
TypePercent in
LayerAsbestos AsbestosPercent in Percent in
Type TypeLayer Layer
CAR-A16 12400997Layer: Grey Cementitious Material NDLayer: Paint ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A17 12400998Layer: Black Cementitious Tar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A18 12400999Layer: Black Cementitious Tar ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A19 12401000Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
CAR-A20 12401001Layer: Grey Cementitious Material ND
Asbestos (ND)Total Composite Values of Fibrous Components:Cellulose (Trace)
Analytical results and reports are generated by SGS Forensic Laboratories (SGSFL) at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGSFL to any third party without prior written request from client. This report applies only to the sample(s) tested.Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGSFL. The client is solely responsiblefor theuse and interpretation of test results and reports requested from SGSFL. SGSFL is not able to assess the degree of hazard resulting from materials analyzed. SGS ForensicLaboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. All samples werereceived in acceptable condition unless otherwise noted.
Note: Limit of Quantification ('LOQ') = 1%. 'Trace' denotes the presence of asbestos below the LOQ. 'ND' = 'None Detected'.Tad Thrower, Laboratory Supervisor, Hayward Laboratory
3 of 33777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
Metals Analysis of PaintsClient ID:Report Number:Date Received:
M232443
Job ID / Site: PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
Forensic Analytical Consulting Svcs HAY01
SGSFL Job ID:
Date Analyzed:
HAY01
Mirna Garcia
Hayward, CA 94545
21228 Cabot Blvd.
Date Printed: 03/18/2103/18/21
First Reported: 03/18/21
03/12/21
Final Report
(AIHA-LAP, LLC Accreditation, Lab ID #101762)
Date(s) Collected: 03/12/21 Total Samples Submitted:Total Samples Analyzed:
14
14
Sample Number Lab Number ResultResult Reporting Method
Analyte Units Limit* Reference
EPA 3050B/7000B< 0.007PbPB1 30885253 wt% 0.007
EPA 3050B/7000B0.056PbPB2 30885254 wt% 0.007
EPA 3050B/7000B0.052PbPB3 30885255 wt% 0.006
EPA 3050B/7000B0.26PbPB4 30885256 wt% 0.02
EPA 3050B/7000B0.010PbPB5 30885257 wt% 0.007
EPA 3050B/7000B0.017PbPB6 30885258 wt% 0.007
EPA 3050B/7000B0.044PbPB7 30885259 wt% 0.007
EPA 3050B/7000B0.065PbPB8 30885260 wt% 0.007
EPA 3050B/7000B0.27PbPB9 30885261 wt% 0.02
EPA 3050B/7000B< 0.006PbPB11 30885263 wt% 0.006
EPA 3050B/7000B< 0.007PbPB12 30885264 wt% 0.007
EPA 3050B/7000B< 0.007PbPB19 30885271 wt% 0.007
EPA 3050B/7000B< 0.006PbPB20 30885272 wt% 0.006
EPA 3050B/7000B< 0.007PbPB21 30885273 wt% 0.007
Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only tothe sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS ForensicLaboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratoriesis not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30)days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGSForensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptableunless otherwise noted.Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.
* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not aregulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.
Kevin Poon, Laboratory Analyst, Hayward Laboratory
3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
1 of 1
Metals Analysis of Bulks - TTLCClient ID:Report Number:Date Received:
M232520
Job ID / Site: PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
Forensic Analytical Consulting Svcs HAY01
SGSFL Job ID:
Date Analyzed:
HAY01
Mirna Garcia
Hayward, CA 94545
21228 Cabot Blvd.
Date Printed: 03/19/2103/19/21
First Reported: 03/19/21
03/12/21
Final Report
(AIHA-LAP, LLC Accreditation, Lab ID #101762)
Date(s) Collected: 03/12/21 Total Samples Submitted:Total Samples Analyzed:
8
8
Sample Number Lab Number ResultResult Reporting Method
Analyte Units Limit* Reference
EPA 3050B/7000B< 7PbPB10 30885262 mg/kg 7
EPA 3050B/7000B8PbPB13 30885265 mg/kg 6
EPA 3050B/7000B9PbPB14 30885266 mg/kg 7
EPA 3050B/7000B< 7PbPB15 30885267 mg/kg 7
EPA 3050B/7000B< 6PbPB16 30885268 mg/kg 6
EPA 3050B/7000B< 7PbPB17 30885269 mg/kg 7
EPA 3050B/7000B610PbPB18 30885270 mg/kg 60
EPA 3050B/7000B10PbPB22 30885274 mg/kg 7
Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only tothe sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS ForensicLaboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratoriesis not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30)days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGSForensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptableunless otherwise noted.Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.
* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not aregulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.
Kevin Poon, Laboratory Analyst, Hayward Laboratory
3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218
1 of 1
Metals Analysis of Soils - TTLCClient ID:Report Number:Date Received:
M232536
Job ID / Site: PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
Forensic Analytical Consulting Svcs HAY01
SGSFL Job ID:
Date Analyzed:
HAY01
Mirna Garcia
Hayward, CA 94545
21228 Cabot Blvd.
Date Printed: 03/23/2103/23/21
First Reported: 03/23/21
03/18/21
Final Report
(AIHA-LAP, LLC Accreditation, Lab ID #101629)
Date(s) Collected: 3/12/21 Total Samples Submitted:Total Samples Analyzed:
1
1
Sample Number Lab Number ResultResult Reporting Method
Analyte Units Limit* Reference
EPA 3050B/7000B3700PbCAR-PB1 30885408 mg/kg 300
Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only tothe sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS ForensicLaboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratoriesis not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30)days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGSForensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptableunless otherwise noted.Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.
* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not aregulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.
Beatriz Hinojosa, Laboratory Supervisor, Carson Laboratory
20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450
1 of 1
Metals Analysis of PaintsClient ID:Report Number:Date Received:
M232535
Job ID / Site: PJ62195; City of Piedmont Piedmont Community Pool and Carriage House 777and 779 Magnolia Avenue Piedmont CA
Forensic Analytical Consulting Svcs HAY01
SGSFL Job ID:
Date Analyzed:
HAY01
Mirna Garcia
Hayward, CA 94545
21228 Cabot Blvd.
Date Printed: 03/23/2103/23/21
First Reported: 03/23/21
03/18/21
Final Report
(AIHA-LAP, LLC Accreditation, Lab ID #101629)
Date(s) Collected: 3/12/21 Total Samples Submitted:Total Samples Analyzed:
9
9
Sample Number Lab Number ResultResult Reporting Method
Analyte Units Limit* Reference
EPA 3050B/7000B4.4PbCAR-PB2 30885409 wt% 0.6
EPA 3050B/7000B4.3PbCAR-PB3 30885410 wt% 0.3
EPA 3050B/7000B0.020PbCAR-PB4 30885411 wt% 0.006
EPA 3050B/7000B21PbCAR-PB5 30885412 wt% 2
EPA 3050B/7000B14PbCAR-PB6 30885413 wt% 0.6
EPA 3050B/7000B25PbCAR-PB7 30885414 wt% 2
EPA 3050B/7000B7.1PbCAR-PB8 30885415 wt% 0.6
EPA 3050B/7000B0.65PbCAR-PB9 30885416 wt% 0.06
EPA 3050B/7000B9.1PbCAR-PB10 30885417 wt% 0.6
Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report.Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only tothe sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS ForensicLaboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratoriesis not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30)days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGSForensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptableunless otherwise noted.Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.
* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not aregulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.
Beatriz Hinojosa, Laboratory Supervisor, Carson Laboratory
20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450
1 of 1
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix B
Appendix B Sample Location Drawing
Carriage House (Interior)
LEGEND Positive Asbestos Bulk Sample Location: N/A Positive Lead Bulk Sample Location: CAR-1, CAR-Pb2, CAR-Pb3, CAR-Pb4, CAR-Pb5, CAR-Pb6, CAR-Pb7
SAMPLE LOCATION DRAWING Carriage House 799 Magnolia Ave. Piedmont, CA FACS # PJ62195 March 12 & 16, 2021
N
A5 A6 A5 A6 A5 A6
CAR-A5 CAR-A6
CAR-A3 CAR-A2 CAR-A4
A1 CAR-A1
CAR-Pb1
CAR-Pb2
CAR-Pb4
CAR-Pb5
CAR-Pb3
CAR-Pb6
CAR-Pb7
Carriage House (Exterior)
LEGEND Positive Asbestos Bulk Sample Location: N/A Positive Lead Bulk Sample Location: CAR-Pb8, CAR-Pb9
SAMPLE LOCATION DRAWING Carriage House 799 Magnolia Ave. Piedmont, CA FACS # PJ62195 March 12 & 16, 2021
N
CAR-A13
CAR-A20
CAR-A10
CAR-A9 CRA-A12
CAR-Pb10
CAR-Pb9
CAR-Pb8
CAR-A19
CAR-A8 CAR-A16
CAR-A15
CAR-A7
CAR-A18 CAR-A11
CAR-A14
CAR-A17
LEGEND Positive Asbestos Bulk Sample Location: N/A Positive Lead Bulk Sample Location: Pb2, Pb3, Pb4, Pb5, Pb6, Pb7, Pb8, Pb9, Pb13, Pb14, Pb18
SAMPLE LOCATION DRAWING Community Pool & Carriage House Asbestos and Lead Survey Piedmont Community Pool 777 Magnolia Avenue Piedmont, CA USA FACS # PJ62195, March 12 & 16, 2021
N
Pool House
LEGEND Positive Asbestos Bulk Sample Location: A13, A14 Positive Lead Bulk Sample Location: N/A
SAMPLE LOCATION DRAWING Community Pool & Carriage House Asbestos and Lead Survey Piedmont Community Pool 777 Magnolia Avenue Piedmont, CA USA FACS # PJ62195, March 12 & 16, 2021
N
Pool House Roof
LEGEND Positive Asbestos Bulk Sample Location: N/A Positive Lead Bulk Sample Location: Pb22
SAMPLE LOCATION DRAWING Community Pool & Carriage House Asbestos and Lead Survey Piedmont Community Pool 777 Magnolia Avenue Piedmont, CA USA FACS # PJ62195, March 12 & 16, 2021
N
Pool Area
LEAD HAZARD EVALUATION REPORT
California Department of Public HealthState of California—Health and Human Services Agency
Section 3 — Structure Where Lead Hazard Evaluation Was Conducted
Lead Inspection Risk assessment Clearance Inspection Other (specify) _____________________________
City County Zip Code
Construction date (year) of structure
Type of structure
Multi-unit building School or daycare
Single family dwelling
Section 4 — Owner of Structure (if business/agency, list contact person)
Address [number, street, apartment (if applicable)] City State
Name Telephone number
Section 5 — Results of Lead Hazard Evaluation (check all that apply)
No lead-based paint detected
No lead hazards detected
Intact lead-based paint detected
Lead-contaminated dust found
Section 6 — Individual Conducting Lead Hazard EvaluationName
Name and CDPH certification number of any other individuals conducting sampling or testing (if applicable)
CDPH certification number Signature Date
Section 7 — Attachments
A. A foundation diagram or sketch of the structure indicating the specifc locations of each lead hazard or presence of lead-based paint;B. Each testing method, device, and sampling procedure used;C. All data collected, including quality control data, laboratory results, including laboratory name, address, and phone number.
First copy and attachments retained by inspector
Second copy and attachments retained by owner
Third copy only (no attachments) mailed or faxed to:
California Department of Public HealthChildhood Lead Poisoning Prevention Branch Reports850 Marina Bay Parkway, Building P, Third FloorRichmond, CA 94804-6403Fax: (510) 620-5656
CDPH 8552 (6/07)
Zip Code
Address [number, street, apartment (if applicable)] City State Zip Code
Telephone number
Section 2 — Type of Lead Hazard Evaluation (Check one box only)
Address [number, street, apartment (if applicable)]
Other____________
No
Deteriorated lead-based paint detected
Lead-contaminated soil found Other____________________
Yes
Don’t Know
Children living in structure?
Section 1 — Date of Lead Hazard Evaluation _____________________
www.forensicanalytical.com Forensic Analytical Consulting Services
Appendix D
Appendix D FACS Personnel Certifications
top related