tsdos.org

Phased Array UT is Now in the AWS D1.1 Code –What Will That Change for NDT of Pole Welds?

Author:Garrett Ehler, AWS-CWI, ASNT/ACCP Level III

Texas NDT Academy

tsdos.org

This presentation will discuss:The Structural Welding Code

What is Phased Array Ultrasonic Testing?

Phased Array and the Code

PAUT Viability in Manufacturing

Summary

tsdos.org

Why inspect?To confirm the product:• Meets customer specifications• Meets the code/standards• Is of high quality• Has full longevity• Is free of defects

tsdos.org

To Eliminate Failures

tsdos.org

To Prevent Field Problems

tsdos.org

AWS Structural Welding Code Steel

Clause 8. “Inspection” Lists:• Inspection

Responsibilities• Qualifications of

Inspectors• Details for the acceptable

forms of NDT• Acceptance Criteria

tsdos.org

Inspection PlansWeld Inspection Programs Should Include:• Verification of Welder

Qualifications• Verification of Inspector

Qualifications• Verification of WPS

qualification status

tsdos.org

Inspection PlansWeld Inspection Programs Should Include:• Verification of the Joint fit-

up and welding conditions are being met.

• Confirmation that the weld was deposited as designed without discontinuity/defect.

tsdos.org

Weld Confirmation• Comprehensive Visual

Inspection• Magnetic Particle

Inspection (If Required)• Ultrasonic Testing (Now

Including PAUT)From AWS D1.1 (2020)

tsdos.org

Conventional Ultrasonic Testing (UT) vs. Phased Array Ultrasonic Testing (PAUT)

Until 2020 Phased Array UT was not recognized in D1.1 (Only Conventional UT)

tsdos.org

Conventional Ultrasonic Testing (UT)• Ultrasonic Testing

Method uses high frequency sound waves traveling through a part to detect discontinuities.

tsdos.org

Conventional UT• A single

piezoelectric element is acoustically coupled with a part to generate the sound wave for a full volumetric inspection.

tsdos.org

Conventional UT• Technician relies

on a scanning pattern to achieve the full volumetric inspection.

• Scanning is performed along 2 axis with an added oscillation (Movement A).

tsdos.org

Phased Array Ultrasonic Testing (PAUT)

Phased Array UT (PAUT) uses a probe built from multiple elements (16 to 128+) of the same frequency acting in unison as an array.

tsdos.org

PAUT Beam SteeringAs waves from each element interact based on designed focal laws, phasing effects increase or decrease wave energies at the point of combination to steer or focus the beam.

tsdos.org

Typical PAUT Imaging

Traditional “A” Scan (Top left)

“S” or Sectoral

Scan (Top Right)

Encoded “B” Scan (Bottom)

tsdos.org

PAUT vs. UTPAUT – “A” and “S” Scan Conventional “A” Scan

tsdos.org

PAUT and the CodeAWS D1.1 (2020)

tsdos.org

PAUTAnnex H Dictates:• Personnel Requirements• Equipment Requirements• Scan Plan• Calibration Requirements• Full Examination Procedures• Evaluation/Analysis• Documentation and Reporting.

tsdos.org

PAUT In the Manufacturing Environment

• Annex H – Gives full details for use of PAUT to test D1.1 weldments.

Meets the Requirements of

D1.1 2020

• 30° thru 80° shear waves simultaneously.

Real time dynamic imaging

• Complex weldments• Randomly orientated discontinuities.

Increased probability of

detection

tsdos.org

PAUT In the Manufacturing Environment

Excellent for confirmation of penetration in partial join penetration weldments.• Long seams• Arm bracket to shaft weldments

Volumetric inspections of complete joint penetration weldments.• Base Plate/Flange to Pole Shaft.• Arm Bracket to Shaft Weldments.• CJP Areas of Long Seams

tsdos.org

PAUT In the Manufacturing Environment

Increased accuracy during toe crack inspection and remediation.• Post Galvanized Flange/Base Plate to Shaft Welds

Comprehensive corrosion mapping of in-service materials.• Direct Embedded structures

tsdos.org

PAUT VS ConventionalIn tough Joint Configurations

Conventional UT has trouble reaching the root of the weld

on thin materials.

.25” Material In a T-Joint Configuration

Pole Shaft Wall

Base Plate

PAUT VS ConventionalIn tough Joint Configurations

Same material configuration with a

PAUT probe providing complete coverage of

the volume of the weld. Pole Shaft Wall

Base Plate

tsdos.org

PAUT In the Manufacturing Environment

• Higher probability of detection.• Increased accuracy of inspections.• Fewer escapes to the field.• More consistency of finished product.

tsdos.org

Questions?Garrett Ehler

Texas Nondestructive Testing Academywww.TXNDT.com