Patient Care DevicesPatient Care Devices
HIMSS10 Webinar Series; October 22 2009 HIMSS10 Webinar Series; October 22 2009
22
AgendaAgenda
PCD Domain OverviewPCD Domain Overview Published Profiles: DEC, PIV, ACM, IDCO, Published Profiles: DEC, PIV, ACM, IDCO,
RTMRTM New Profiles/White Papers: DPI, WCM, MEMNew Profiles/White Papers: DPI, WCM, MEM Considered for PCD Cycle 5Considered for PCD Cycle 5 Showcase DemonstrationsShowcase Demonstrations ContactsContacts Q & AQ & A
NOTE: Update to 2008, 2009 IHE PCD WebinarNOTE: Update to 2008, 2009 IHE PCD Webinar
33
IHE Patient IHE Patient CareCare Devices (PCD) Devices (PCD)
IHE-PCD CharterIHE-PCD Charter
The Patient Care Device Domain is concerned The Patient Care Device Domain is concerned with with use casesuse cases in which at least one actor is a in which at least one actor is a patient-centric point-of-care medical devicepatient-centric point-of-care medical device . . The PCD The PCD coordinatescoordinates with other IHE clinical with other IHE clinical specialty based domains such as medical specialty based domains such as medical imaging and lab to ensure imaging and lab to ensure consistencyconsistency of of medical device integration solutions across all medical device integration solutions across all IHE technical frameworks.IHE technical frameworks.
NOTE: NOTE: Formed in 2005 & sponsored by HIMSS & ACCEFormed in 2005 & sponsored by HIMSS & ACCE
44
PCD Domain OverviewPCD Domain Overview
• Heterogeneity – … coexistence in a multi-vendor & multi-modality world, leveraging shared infrastructure
• Semantic Interoperability – … from the sensor to the EHR
• Real-time Availability – … facilitating more timely clinical decisions
PCD Profile Primary Objectives:PCD Profile Primary Objectives:
Ultimately providing improved – … safety, quality of care & workflow efficiency
55
PCD - Published ProfilesPCD - Published Profiles
DEC ProfileDEC Profile
Device to Enterprise CommunicationDevice to Enterprise Communication
Trial ImplementationTrial Implementation
66
Device Enterprise Communication (DEC)Device Enterprise Communication (DEC)
77
(DEC-PIB) Patient ID Binding(DEC-PIB) Patient ID Binding
ITI-PAMITI-PAM
ITI-PDQITI-PDQ
Note: Note: This is an option to DEC for coordinating authenticated patient IDs.This is an option to DEC for coordinating authenticated patient IDs.
88
SPD - Subscribe to Patient DataSPD - Subscribe to Patient Data
Note: Note: This is an option to DEC for configuring PCD-01 content & frequency.This is an option to DEC for configuring PCD-01 content & frequency.
99
SPD - Subscribe to Patient DataSPD - Subscribe to Patient Data
1010
RTMRTM
RTM ProfileRTM Profile
Rosetta Terminology MappingRosetta Terminology Mapping
Trial ImplementationTrial Implementation
1111
Rosetta for Semantic InteroperabilityRosetta for Semantic Interoperability
1212
Rosetta for Semantic InteroperabilityRosetta for Semantic Interoperability
Migrating Toward True PCD Semantic Interoperability
Today HIMSS ’10!
ISO/IEEE 11073Semantic Standards
Vendor Semantics
IHE PCD TF Content
Vendor A
Vendor C
Vendor B
RosettaMappingTables(RTM)
11073PnP Comm
HL7 v3CDA/CCD
HL7 v2Messages
1313
RTM GoalsRTM GoalsExpandExpand the number of numeric parameters
supported by PCD-01 from 40 today to over 350 terms, providing a more comprehensive set for development and validation.
HarmonizeHarmonize the use of existing nomenclature terms defined by ISO/IEEE 11073-10101.
SpecifySpecify the units-of-measureunits-of-measure, enumerated valuesenumerated values and measurement sites associated with each parameter.
Identify and add new nomenclature termsIdentify and add new nomenclature terms that are currently missing from ISO/IEEE 11073-10101.
NOTE: Respiratory / Ventilator terms are a major area. See http://wiki.ihe.net/index.php?title=PCD_RTM_Ventilatorhttp://wiki.ihe.net/index.php?title=PCD_RTM_Ventilator
1414
ACMACM
ACM ProfileACM Profile
Alarm Communication ManagementAlarm Communication Management
Trial ImplementationTrial Implementation
1515
Alarm Communication Management (ACM)Alarm Communication Management (ACM)
Alarm Communication Management
enables systems to deliver the right alarms, with the right priority, to the right individuals via devices with the right content, escalating to other individuals via devices (based on system configuration)
Alarm Communication Management
enables systems to deliver the right alarms, with the right priority, to the right individuals via devices with the right content, escalating to other individuals via devices (based on system configuration)
Trial Implementation
1616
ACM Data FlowsACM Data Flows
AlarmSource
AlarmAggregator
AlarmReceiver
AlarmCoordinator
AlarmDisseminator
AlarmCommunication
AlarmEndpoint
AlarmCommunication
AC
AlarmCommunication
AC
AlarmManagement
AM
AlarmManagement
AM
AlarmReporter
AR
AlarmReporter
AR
AlarmReporter
AlarmCache
Communication detailed in ACM profileCommunication detailed in ACM profile
Communication not detailed in ACM profileCommunication not detailed in ACM profile
.
.
.
.
.
.......
PCD Inputs(PM, NC, Resp,
Pump, etc.)
PCD Inputs(PM, NC, Resp,
Pump, etc.)
Output Devices(Marquee Sign, Pager,
Wi-Fi Phone or Badge, etc.)
Output Devices(Marquee Sign, Pager,
Wi-Fi Phone or Badge, etc.)
HIS, EMRHIS, EMRAlarm
ArchiverAA
AlarmArchiver
AA
Report Alarm Report Alarm
Alarm StatusAlarm Status**Alarm StatusAlarm Status**
*Note: Implementation TBD*Note: Implementation TBD
Subscribe to AlarmSubscribe to Alarm **Subscribe to AlarmSubscribe to Alarm **
** Disseminate Alarm ** Disseminate Alarm Dissemination StatusDissemination Status **Dissemination StatusDissemination Status **
Report AlarmReport AlarmReport AlarmReport AlarmSubscribe to Alarm Subscribe to Alarm ** Subscribe to Alarm Subscribe to Alarm **
GapGap!!
1717
ACM UpdatesACM Updates
Fill Gap: Alarm Manager (AM) to Alarm Communicator (AC)
Define alarm identifier codes (RTM for alarms)
Extend implementation of actors & transactions
Expand to additional IHE domains
1818
PIVPIV
PIV ProfilePIV Profile
Point-of-Care Infusion VerificationPoint-of-Care Infusion Verification
Trial ImplementationTrial Implementation
1919
Point-of-Care Infusion Verification supports the electronic transfer of infusion parameters from a Barcode Point of Care (BPOC) system, also known as a Bar Code Medication Administration (BCMA) system, to an infusion pump.
Point-of-Care Infusion Verification supports the electronic transfer of infusion parameters from a Barcode Point of Care (BPOC) system, also known as a Bar Code Medication Administration (BCMA) system, to an infusion pump.
PIV StatementPIV Statement
2020
PIV WorkflowPIV Workflow
Nurse
Review
MAR Entry
Pharmacist reviews
order detail
(Pharmacy
System)
eMAR updated
Medication
DispensedNurse removes
Medication
from Dispensing
Unit or Med Room
Nurse Confirms 5
Rights:
Right Patient,
Medication,
Dose, Time, Route
AT THE BEDSIDE
Medication
Administered
Physician reviews
data and places
Orders
Nurse
Review
eMAR Entry
Pharmacist reviews
order detail
(Pharmacy
System)
eMAR updated
Medication
DispensedNurse removes
Medication
from Dispensing
Unit or Med Room
Nurse Confirms 5
Rights:
Right Patient,
Medication,
Dose, Time, Route
AT THE BEDSIDE
Medication
Administered
Physician reviews
data and places
Orders
This is the focus ofThis is the focus ofPIV … only!PIV … only!
2121
PIV ActorsActors
DEC!DEC!
2222
IDCOIDCO
IDCO ProfileIDCO Profile
Implantable Device – Implantable Device – Cardiac Cardiac – Observation– Observation
Trial ImplementationTrial Implementation
2323
Implantable Device – Cardiac – Observation ProfileImplantable Device – Cardiac – Observation Profile
• IDCO specifies the creation, IDCO specifies the creation, transmission, and processing of transmission, and processing of discrete data elements and report discrete data elements and report attachments associated with attachments associated with implantable cardiac device implantable cardiac device interrogations (observations) or interrogations (observations) or messages.messages.
2424
Implantable Cardiac DeviceImplantable Cardiac Device
ImplantableCardiac Device
Leads for Sensingor Delivering Electrical Therapy
2525
IDCO Profile ContextIDCO Profile Context• Device is interrogated via inductive or wireless telemetry in clinic or home
environment using vendor proprietary equipment
• Information is transferred to clinic system as structured HL7 v2.6 ORU message using IEEE 11073 IDC nomenclature [PCD-09]
2626
IDCO ActorsIDCO Actors
2727
PCD – Emerging ProfilesPCD – Emerging Profiles
Emerging ProfilesEmerging Profiles Implanted Cardiac Devices (IDCO)Implanted Cardiac Devices (IDCO) Waveform Communication Management (WCM)Waveform Communication Management (WCM) Medical Equipment Management (MEM)Medical Equipment Management (MEM) Real Time Location TrackingReal Time Location Tracking Device Point-of-Care Integration (DPI, a multiyear Device Point-of-Care Integration (DPI, a multiyear
effort)effort) Real-time data archiving and communicationReal-time data archiving and communication Mobile, enterprise-wide, reliable vital signs Mobile, enterprise-wide, reliable vital signs
monitoringmonitoring … … many more!many more!
2828
DPIDPI
Device Point-of-Care Integration Device Point-of-Care Integration [DPI][DPI]
2929
DPI: Scope –
Device Point-of-care Integration (DPI) is concerned with use cases that include care contexts that fall within the stated charter of the IHE PCD, namely where "at least one actor is a one actor is a regulated patient centric point-of-care medical regulated patient centric point-of-care medical devicedevice," and that require device-to-device device-to-device communicationcommunication.
IHE PCD Profile: DPIIHE PCD Profile: DPI
3030
IHE PCD Profile: DPIIHE PCD Profile: DPI
Device Point-of-Care IntegrationDevice Point-of-Care Integration• Discovery and Association (PnP)Discovery and Association (PnP)• Real-Time Data ReportingReal-Time Data Reporting• Bi-Directional / SymmetricBi-Directional / Symmetric• External ControlExternal Control
Enterprise IntegrationEnterprise Integration
Semantic InteroperabilitySemantic Interoperability
Monitored ParametersMonitored ParametersAlarms & LimitsAlarms & LimitsWaveforms (Real-Time)Waveforms (Real-Time)Control ParametersControl Parameters
Semantic InteroperabilitySemantic Interoperability
Monitored ParametersMonitored ParametersAlarms & LimitsAlarms & LimitsWaveforms (Real-Time)Waveforms (Real-Time)Control ParametersControl Parameters
Device Reporting, Device Reporting, Management & Management &
ControlControl
Device Reporting, Device Reporting, Management & Management &
ControlControl
Real-TimeClinical Decision Support
Point-of-Care
Applications Real-Time
Closed / OpenLoop Control
DPI Manager / Enterprise
Gateway
DPI Manager / Enterprise
Gateway
3131
PCD - MEMPCD - MEM
Medical Equipment Management Medical Equipment Management [MEM][MEM]
Imagine … Imagine …
What if I.T. & device vendors gave me What if I.T. & device vendors gave me EVERYTHING I ever wanted?!EVERYTHING I ever wanted?!
3232
MEMMEM
DEVICE MANAGEMENT
REPORTER
Patch ManagementPending patchesPatch history
Location ServicesCurrent locationPrevious locations (Trending)Boundary controls (Alarm when
device leaves area)
Device Configuration Management
Recall ManagementUnique device identificationHardware configuration (serial numbers, etc)Software configuration (revision numbers, etc)
Device ReconfigurationUse profiles (NICU vs. CICU)
Operational Status and Monitoring
Is the device currently in useUsage historyAlarms – which are active, what the trigger
levels, how long has the alarm been onDay/time of last self check and its resultEvent log recordingPreventative Maintanence
Last PMNext scheduled PMLast repair time/date
Battery ManagementOn A/C or D/C? Charge level (% of full)/Est.
operating time left. Charging / Discharging historyBattery type and installation date Est. battery life
IHE
PC
D
Sta
nd
ard
s b
ased
T
ran
sac
tio
ns
DEVICE MANAGEMENT
CONSUMER
DPIDECACM
Risk ManagementSupport for IEC 80001-1 ...
v Activities (incl. configuration and network performance monitoring)
v Risk Management Filev ...
3333
MEM StatusMEM Status
2009 – White Paper2009 – White Paper Ongoing workOngoing work
– Cycle 5 Brief Profile Proposal Cycle 5 Brief Profile Proposal • Real Time Location TrackingReal Time Location Tracking
– Location Boundary AlarmsLocation Boundary Alarms– Battery ManagementBattery Management– Semantic Content RequirementsSemantic Content Requirements
3434
PCD - WCMPCD - WCM
WaveformWaveformCommunicationCommunication
Management [WCM]Management [WCM]
3535
WCMWCM
Waveform Communication ManagementWaveform Communication Management
will extend the [DEC] profile to provide a method will extend the [DEC] profile to provide a method for passing for passing near real-time waveform datanear real-time waveform data using using HL7 v2 observation messagesHL7 v2 observation messages between a between a Reporter and a Consumer.Reporter and a Consumer.
• A filter will be an optional element A filter will be an optional element
3636
WCMWCM
WCM will cover the following prioritized WCM will cover the following prioritized Use Cases:Use Cases:
1.1. Current Multi-Channel Waveform (MCW) Current Multi-Channel Waveform (MCW) snapshotsnapshot as defined by the source is created/pushed by as defined by the source is created/pushed by alarm source based on alarm source based on eventevent occurrence occurrence
2.2. Current MCW Current MCW snapshotsnapshot as defined by source on as defined by source on requestrequest to source to source
3.3. Continuous MCW Continuous MCW streamsstreams4.4. MCW snapshot MCW snapshot archivearchive query query5.5. Periodic Periodic trendtrend data on request data on request
It is not expected that all Use Cases will be It is not expected that all Use Cases will be covered during the first cycle.covered during the first cycle.
3737
WCMWCM
• A number of existing standards will be A number of existing standards will be evaluated as references:evaluated as references:– MFERMFER (ISO 11973-92001) (ISO 11973-92001)– FEFFEF (ISO 14271) (ISO 14271)– FDA HL7 v3 Annotated ECGFDA HL7 v3 Annotated ECG Guideline Guideline– DICOMDICOM Supplement 30 – Waveform Supplement 30 – Waveform
Interchange Interchange – Previous HL7 v2 waveform spec (deprecated)Previous HL7 v2 waveform spec (deprecated)
• Our scope is to create a profile which Our scope is to create a profile which leverages existing IHE PCD Profiles and leverages existing IHE PCD Profiles and “principles” of using HL7 v2.x and IEEE “principles” of using HL7 v2.x and IEEE 11073 nomenclature.11073 nomenclature.
3838
WCMWCM Key requirements:Key requirements:
LeverageLeverage existing IHE PCD Profiles and existing IHE PCD Profiles and “principles” of using HL7 v2.x and IEEE 11073 “principles” of using HL7 v2.x and IEEE 11073 nomenclature.nomenclature.
Provide Provide raw dataraw data and not bit-maps or pdf files and not bit-maps or pdf files• Supports rendering at end clientSupports rendering at end client• Supports further analysis at end clientSupports further analysis at end client
Support “Support “snapshotssnapshots”, data “”, data “streamsstreams” and ” and retrospective “retrospective “trendtrend” data types” data types
Minimize optionalityMinimize optionality• Focus on simplicity and avoid complexityFocus on simplicity and avoid complexity
3939
PCD - Cycle 5PCD - Cycle 5
Under Consideration for Under Consideration for
the Next Cyclethe Next Cycle
4040
Proposed Work for Cycle 5 (out for ballot)
• Asynchronous Data Query
• Location Tracking
• Medical Equipment Management
• Query for Bulk Data
• Device to Patient Association
• Device Integration (specific devices)
• Device Integration - General Content
• Event Communication
4141
PCD - TestingPCD - Testing
Test Tooling SupportTest Tooling Support
VA’s Message WorkbenchVA’s Message Workbench
NIST ToolsNIST Tools
4242
PCD & SDO CoordinationPCD & SDO Coordination
PCD coordination with SDOs…PCD coordination with SDOs…
IHE - HL7 IHE - HL7 (MoU)(MoU)
IHE - IEEE EMB IHE - IEEE EMB (MoU)(MoU)
IHE – ISO TC215 IHE – ISO TC215 (Liaison)(Liaison)
……
4343
PCD & HITSPPCD & HITSP
(from HITSP TC Orientation 2009.02.17)
4444
PCD & Continua Health AlliancePCD & Continua Health Alliance
Continua & IHE established a Memorandum of Continua & IHE established a Memorandum of Understanding (“MoU”) Understanding (“MoU”) to “to “enable and promote enable and promote interoperability of healthcare devicesinteroperability of healthcare devices.”.”
Provides for joint participation in Interoperability Provides for joint participation in Interoperability Showcases (e.g., @ HIMSS ’10)Showcases (e.g., @ HIMSS ’10)
Coordination on HITSP RMON SDE#2 is laying the Coordination on HITSP RMON SDE#2 is laying the foundation for interoperability from bedroom to OR!foundation for interoperability from bedroom to OR!
4545
PCD & ASTM “ICE” / CIMIT MDPnPPCD & ASTM “ICE” / CIMIT MDPnP
(From ICE-PAC Overview Update 2009.06.22 to IHE PCD)
ICE-PCD Analysis Committee (ICE-PAC)ICE-PCD Analysis Committee (ICE-PAC) – JWG underway to perform a map & gap analysis between “ICE” use case analyses, ISO/IEEE 11073 standards & the IHE DPI WG.
4646
PCD & ICE-PAC JWGPCD & ICE-PAC JWG
(From ICE-PAC Overview Update 2009.06.22 to IHE PCD)
4747
PCD - ShowcasePCD - Showcase
HIMSS ShowcaseHIMSS Showcase
Where we get to show off !!Where we get to show off !!
4848
HIMSS Showcase ’09 - ProductsHIMSS Showcase ’09 - Products
4949
HIMSS Showcase ’09 - ORHIMSS Showcase ’09 - OR
5050
HIMSS Showcase ’09 - ICUHIMSS Showcase ’09 - ICU
5151
HIMSS Showcase ’09 – Step Down UnitHIMSS Showcase ’09 – Step Down Unit
5252
PCD @ HIMSS 2009PCD @ HIMSS 2009
5353
HIMSS ’09 IHE Showcase SponsorsHIMSS ’09 IHE Showcase Sponsors
5454
Why use IHE PCD profiles?Why use IHE PCD profiles?
• Simplified standards-based integration of point-of-care device info & services
• Multi-vendor product integration testing @ Connectathons
• Visibility of products with care providers and peer technology organizations in Showcases
• Path to programs such as the U.S. National Health Information Network (NHIN)
PCD profiles will enable…PCD profiles will enable…
5555
IHE PCD DEC: Simplified SpecsIHE PCD DEC: Simplified Specs
5656
For Further InformationFor Further Information
• InternetInternet– Web:Web: www.ihe.net/pcdwww.ihe.net/pcd
www.accenet.org/ihewww.accenet.org/ihe
– Wiki:Wiki: wiki.ihe.net/index.php?title=Patient_Care_Devicewiki.ihe.net/index.php?title=Patient_Care_Device
• PCD Co-ChairsPCD Co-Chairs– Ken FuchsKen Fuchs Planning CommitteePlanning Committee ken.fuchs@draeger.com ken.fuchs@draeger.com – Steve Merritt Steve Merritt Planning CommitteePlanning Committee steve.merritt@bhs.orgsteve.merritt@bhs.org
– Todd Cooper Todd Cooper Technical CommitteeTechnical Committee t.cooper@IEEE.org t.cooper@IEEE.org – John RhoadsJohn Rhoads Technical CommitteeTechnical Committee john.rhoads@Philips.comjohn.rhoads@Philips.com
• PCD Technical Project ManagerPCD Technical Project Manager– Manny FurstManny Furst efurst@IEEE.orgefurst@IEEE.org
• Sponsor RepresentativesSponsor Representatives– Jack HarringtonJack Harrington HIMSSHIMSS jackh82@comcast.netjackh82@comcast.net– Elliot SloaneElliot Sloane IHE InternationalIHE International ebsloane@IEEE.org ebsloane@IEEE.org – Ray ZambutoRay Zambuto ACCEACCE
Ray.Zambuto@techmed.lincfs.comRay.Zambuto@techmed.lincfs.com
5757
top related