contents
MK 2200LMK 2200MK 1000A
MK 233AMK 234AMK 203AMK 204A
MK 231AMK 232AMK 201AMK 202A
MK 300A / 300EAMK 330AMK 301A / 302A / 301EDIN 330DIN 310 / 310EDIN 300 / 300EZCT 40S / 60S / 80S / 120S / 210S
MU 2300MU 350MU 250 / 150MX 210MX 200A / 180A / 160AMX 100 / 50
RPR 415ARPR 415
PFR 140 / 120 / 80 / 60PFR 96 / 96PPFR LCD
AN 112 / 120 / 128AL 24
DVMDAMDPM 680DPM 380 / 380BDM 38
Combined Overcurrent &Earth Fault Relay
Overcurrent Relay
Earth Fault Relay
Earth Leakage Relay
Voltage Relay
Reverse Power Relay
Power Factor Regulator
Annunciator
Digital Power Meter
MPR 500Motor Protection Relay
reference colour tags
Print EditionJune 2015
( 423468-T )
No.1 Jalan TP 7/7, Sime UEP Industrial Park,40400 Shah Alam, Selangor, Malaysia.Website: www.itmikro.com Tel: +60-3-5192-7155 Fax: +60-3-5192-7166
Mikro® reserves the right to make changes without further notice to any products herein to improve reliability, function or design. The figures shown are without obligation.
MK2200L
Technical Data
RATINGS
Auxiliary SupplyModel MK2200L-150DRated voltage : 30 ~ 120 V DCOperating voltage : 24 ~ 150 V DC
Model MK2200L-240ADRated voltage : 100 ~ 240 V AC or 140 ~ 340 V DCOperating voltage : 85 ~ 265 V AC or 110 ~ 370 V DCRated frequency : 50 or 60 HzOperating frequency : 45 ~ 65 HzPower consumption : 8 VA max
Current Inputs Rated current, In, Ion : 1 or 5 A by connectionFrequency : 50 or 60 Hz nominalBurden : < 0.025 VA (1 A) : < 0.3 VA (5 A)Thermal withstand : 4 x In continuous : 40 x In for 2s : 100 x In for 1s
Digital Inputs Input type : Optically isolatedRated voltage : 20 ~ 380 V DC : 50 ~ 270 V AC
Output Contacts Trip Contact Relay R1, R2, R3, R4, IRF RelayRated voltage : 250 V AC / DCContinuous carry : 5 AExpected electrical life : 100,000 operations at rated loadExpected mechanical life : 5 x 106 operations
Features
• Multifunction numerical relay
• Three-phase, three stages setting for phase overcurrent
• Two stages setting for earth fault
• IDMT and definite time
• Thermal overload protection
• Two groups of protection settings
• Trip circuit supervision
• Circuit breaker failure protection
• RS232 and RS485 MODBUS-RTU communication
• Fault, alarm and tripping records with timestamp
• Multifunction programmable outputs
• Multifunction digital inputs
• Complies with IEC 60255-26 standard
• ANSI code : 49RMS, 50P, 50G, 51P, 51G, CLP, 50BF, 74TC
Com
bined Overcurrent &
Earth Fault R
elay
RECORDS Fault Record : Up to 50 recordsEvent Record : Up to 250 recordsAlarm Record : Up to 30 records
SETTING RANGES
General Line CT primary : 1 to 10,000 AEarth CT primary : 1 to 10,000 AFrequency : 50 or 60 Hz
Phase Overcurrent I> : 0.1 to 25 x In (Recommended up to
2 x In for IDMT delay)I> Delay type : IDMT or definite timetI> : 0 to 100 sI> IDMT curve : NI, VI, EI, LTI, NI 1.3/10ktI : 0.01 to 1.00I>> : 0.5 to 40 x IntI>> : 0 to 100 sI>>> : 0.5 to 40 x InI>>> Sample : Yes or NotI>>> : 0 to 100 s
Earth Fault Io> : 0.02 to 2 x Ion (Recommended up
to 0.5 x Ion for IDMT delay)Io> Delay type : IDMT or definite timetIo> : 0 to 100 sIo> IDMT curve : NI, VI, EI, LTI, NI 1.3/10ktIo : 0.01 to 1.00Io>> : 0.1 to 10 x IontIo>> : 0 to 100 s
Thermal Overload I > : 0.1 to 3 x InT : 1 to 200 minutesk : 1 to 1.5
Trip : 50 to 200%Alarm : 50 to 200%
MEASUREMENT RANGES Phase Current Secondary:5 A input : 0 to 200 A1 A input : 0 to 40 A
Earth Current Secondary:5 A input : 0 to 50 A1 A input : 0 to 10 A
ENVIRONMENTAL CONDITIONS Temperature : -5˚C to 55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d)Enclosure protection : IP54 at the panelApproximate weight : 2.9 kg
MK
2200L
Ordering Information
MK2200L - 150D For 50/60 Hz, auxiliary voltage 24 ~ 150 V DCMK2200L - 240AD For 50/60 Hz, auxiliary voltage 85 ~ 265 V AC or 110 ~ 370 V DC
MODEL DESCRIPTION
Case Dimensions
Normal Inverse Very Inverse Extremely Inverse
Long Time InverseTypical Application Diagram 1
Typical Application Diagram 2
Com
bined Overcurrent &
Earth Fault R
elay142 mm
165
mm
Front
Panel Cutout
198 mm34 mm
136
mm
Side
139
±1 m
m
129 ±1 mm
MK
2200L
MK2200
Technical Data
INPUTS Measuring input: Rated current In : 1 A or 5 ARated frequency : 50 or 60 HzThermal withstand : 4 x In continuous 25 x In for less than 10 sec 100 x In for less than 1 secBurden : < 0.3VA at In
Rated auxiliary voltage:Model MK2200-150D : 24~150 V DCModel MK2200-240A : 198~265 V ACModel MK2200-240AD : 85~265 V AC
110~340 V DC
Power consumption:AC auxiliary voltage : 6 ~ 10 VA typicalDC auxiliary voltage : 5 ~ 9 W typical
Binary Input:External binary input : 18 ~ 265 V DC 85 ~ 265 V AC
OUTPUT CONTACTS5 programmable contacts +1 IRF contact:Rated voltage : 250 V AC / DCContinuous carry : 5 A
Contact specification:Expected electrical life : 100,000 operations
at rated currentExpected mechanical life : 5 x 106 operations
Features
• Multifunction numerical relay
• Three-phase, low-set and high-set phase overcurrent
• Two sets of low-set and high-set setting for phase overcurrent
• Low-set and high-set earth fault
• Two sets of low-set and high-set setting for earth fault
• Circuit breaker failure protection
• Four selectable IDMT characteristic curves
• Definite time for low-set and high-set
• Numeric display of phase and earth fault currents
• Display of relay settings
• 9 non- volatile records of previous tripping currents
• Recording of relay start time
• Highly flexible programmable relay outputs
• Multifunction external digital input
• Isolated RS485 Modbus - RTU communication
• Selectable 50 Hz / 60 Hz
• ANSI code : 50P, 50G, 51P, 51G, 50BF
Com
bined Overcurrent &
Earth Fault R
elay
ACCURACYProtection thresholds : ± 3%Time delay : ± 2% with a minimum
of 30 msMeasurements : ± 3%Reset ratio : 95% typicalOvershoot time : less than 30 ms typical
EARTH-FAULT ELEMENTLow-set setting I o> : 0.05 ~ 1.0 x In ,
step 0.01
High-set setting I o>> : 0.05 ~ 10.0 x In , step 0.05
Time multiplier kt o> : 0.02 ~ 1.0 , step 0.01
Low set definite time t o>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1
High set definite time t o>>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1
OVERCURRENT ELEMENTLow-set setting I > : 0.10 ~ 2.50 x In ,
step 0.01
High-set setting I >> : 0.10 ~ 40 x In , 0.1 ~ 10 In : step 0.05 10 ~ 40 In : step 0.1
Time multiplier kt > : 0.02 ~ 1.0 , step 0.01
Low set definite time t >, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1
High set definite time t >>, 0 ~ 300 s : 0 ~ 10.0s : step 0.01 10.0 ~ 100s : step 0.1 100 ~ 300s : step 1
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing
MECHANICAL Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d) Enclosure protection : IP54 at the panelApproximate weight : 2.9 kg
COMMUNICATIONRS485 Modbus - RTU
MK
2200
Com
bined Overcurrent &
Earth Fault R
elay
Ordering Information
MK2200 - 150D For 50/60 Hz system, auxiliary voltage 24 ~ 150 V DCMK2200 - 240A For 50/60 Hz system, auxiliary voltage 198 ~ 265 V ACMK2200 - 240AD For 50/60 Hz system, auxiliary voltage 84 ~ 265 V AC
or 110 ~ 340 V DC
MODEL DESCRIPTION
Case Dimensions
Normal Inverse Very Inverse Extremely Inverse
Long Time InverseTypical Application Diagram 1
Typical Application Diagram 2
142 mm
165
mm
Front
Panel Cutout
198 mm34 mm
136
mm
Side
139
±1 m
m
129 ±1 mm
1 100.1
1
10
0.05
0.1
0.2
0.3
0.40.50.60.70.80.91.0
20
k
t/s
I/I > 1 100.01
0.1
1
10
0.05
0.1
0.2
0.30.40.50.60.81.0
20
k
t/s
I/I >1 10
0.01
0.1
1
10
100
0.05 0.1 0.2
0.30.40.50.60.81.0
20
k
t/s
I/I >
t/s
I/I >
L1
L2
L3
Trip Contact
R1
R2
R3
R4
R5
Internal
Relay
Failure
Termination Resistor
N-
P+Communication
Cable Shield
RS485
External
Binary
Input
Auxiliary
input Uaux
1 343635
3837
4039
4241
2726
28302922
23
24
25
2
3
45
6
78
9
1011
COM
5 A
COM
5 A
COM
1 A
1 A
1 A
5 A
COM
1 A
5 A
12
32
31
33
13
14
LOAD
L2
L1
L3
N
Trip Contact
R1
R2
R3
R4
R5
Internal
Relay
Failure
Termination Resistor
N-
P+Communication
Cable Shield
RS485
External
Binary
Input
Auxiliary
input Uaux
1 343635
3837
4039
4241
2726
28302922
23
24
25
2
3
45
6
78
9
1011
COM
5 A
COM
5 A
COM
1 A
1 A
1 A
5 A
COM
1 A
5 A
12
32
31
33
13
14
LOAD
MK
2200
MK1000A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThemal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK1000A-240A(6) : 198 ~ 265 V ACModel MK1000A-240AD(6) : 85 ~ 265 V AC 110 V DC ~ 340 V DCModel MK1000A-150D(6) : 24 ~ 150 V DCSupply frequency : 50 or 60 HzV A rating : 3 VA typical
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a
minimum of 50 ms
OUTPUT CONTACTS
Trip Contacts ( R1 & R2 )Rated voltage : 250V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations
at rated currentExpected mechanical life : 5 x 106 operations
Technical Data
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Three-phase, low-set overcurrent
• Three-phase, high-set overcurrent
• Low-set earth-fault
• High-set earth-fault
• Definite time for low-set and high-set
• Five selectable IDMT characteristic curves
• Local display of measured and set values
• Programmable relay outputs
• Non-volatile fault values recording
• Complies with IEC 60255-26 standard
• ANSI Code : 50P, 50G, 51P, 51G
SETTING RANGESi ) Overcurrent elementsLow-set ( I > ) : 0.5 A to 10.0 A,
step 0.05 A : 10% to 200%,
step 1%Low-set time multiplier ( kt >): 0.05 to 1.0,
step 0.01Low-set definite time ( t > ) : 0.05 to 99s High-set ( I >> ) : 0.5 A to 99.9 A,
step 0.10 A or disable
: 10% to 1998%, step 2%
High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01
ii ) Earth-fault elementLow-set ( I o > ) : 0.10 A to 5.0 A,
step 0.05 A : 2% to 100%Low-set time multiplier(kt o>): 0.05 to 1.0,
step 0.01Low-set definite time ( t o > ) : 0.05 to 99sHigh-set ( I o >> ) : 0.10 A to 50 A,
step 0.10 A or disable
: 2% to 1000%, step 2%
High-set delay time ( t o >> ) : 0.05 sec to 2.5 sec, step 0.01
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display
and red indicators
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg
Com
bined Overcurrent &
Earth Fault R
elayM
K 1000A
Com
bined Overcurrent &
Earth Fault R
elay
Normal Inverse 1.3/10
Very Inverse
MK1000A
R1 R2
COM NC NOCOMNCNO
62 3 4 5
9 10 11 12 13 14
7
15
8
16
1
AuxNL
L1
L2
L3
N
LOA
D
Typical Application Diagram
Case Dimensions
Ordering Information
Normal Inverse
MK1000A-240A For 50Hz system, auxiliary voltage 198 ~ 265 V ACMK1000A-240AD For 50Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DCMK1000A-150D For 50Hz system, auxiliary voltage 24 ~ 150 V DCMK1000A-240AD6 For 60Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DCMK1000A-150D6 For 60Hz system, auxiliary voltage 24 ~ 150 V DC
MODEL DESCRIPTION
Long Time Inverse
Extremely Inverse
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
MK
1000A
MK233A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK233A-240A (6) : 198 ~ 265 V ACModel MK233A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical
echnical Data
Features• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Three-phase, low-set overcurrent
• Three-phase, high-set overcurrent
• Local display of measured and set values
• Definite time for low-set and high-set
• Non-volatile fault value recording
• Programmable relay outputs
• Five selectable IDMT characteristic curves
• Complies with IEC 60255-26 standard
• ANSI Code : 50P, 51P
SETTING RANGES
Low-set ( I > ) : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%Low-set time multiplier ( kt > ) : 0.05 to 1.0, step 0.01Low-set definite time (t >) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum of
50 ms
OUTPUT CONTACTS (R1 & R2)
Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life: 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display and
red indicators
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg
Overcurrent R
elayM
K 233A
Overcurrent R
elay
Normal Inverse 1.3/10
Very Inverse
Aux
62 3 4 5
L
R1 R2
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
1
MK 233A
LOA
D
Typical Application Diagram
Case Dimensions
Ordering Information
Normal Inverse
MK233A - 240A For 50 Hz system, auxiliary voltage198 ~ 265 V AC MK233A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK233A - 240A6 For 60 Hz system, auxiliary voltage198 ~ 265 V ACMK233A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
Long Time Inverse
Extremely Inverse
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
MK
233A
MK234A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK234A-240A (6) : 198 ~ 265 V ACModel MK234A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
OUTPUT CONTACTS (R1 & R2)
Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
echnical Data
Overcurrent R
elayFeatures
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Three-phase, low-set overcurrent
• Three-phase, high-set overcurrent
• Local display of measured and set values
• Definite time for low-set and high-set
• Non-volatile fault value recording
• Programmable relay outputs
• Complies with IEC 60255-26 standard
• ANSI : 50P, 51P
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display
and red indicators
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.8 kg
SETTING RANGES
Low-set ( I > ) : 0.5 A to 6.0 A, step 0.05 A / 10% to 120%, step 1%Low-set definite time ( t > ) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.5 A to 99.9 A or disable, step 0.10 A / 10% to 1998%, step 2% High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01 M
K 234A
Overcurrent R
elay
Aux
62 3 4 5
L
R1 R2
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
1
MK 234A
LOA
D
Typical Application Diagram Case Dimensions
Ordering Information
MK234A - 240A For 50 Hz system, auxiliary supply 198 ~ 265 V ACMK234A - 110A For 50 Hz system, auxiliary supply 94 ~ 127 V ACMK234A - 240A6 For 60 Hz system, auxiliary supply 198 ~ 265 V ACMK234A -110A6 For 60 Hz system, auxiliary supply 94 ~ 127 V AC
MODEL DESCRIPTION
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
MK
234A
MK203A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK203A-240A : 198 ~ 265 V ACModel MK203A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical
SETTING RANGES
Low-set ( I > ) : 2.0 A to 6.0 A : 40% to 120%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous
TIME CURRENT CHARACTERISTIC CURVE
- Normal Inverse
echnical Data
Overcurrent R
elayFeatures
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set inverse definite minimum time ( IDMT ) relay
• High-set instantaneous relay
• Separate low-set and high-set trip indicators
• Option to disable high-set relay
• Front panel access to test function
• Complies with IEC 60255-26 standard
• ANSI Code : 50P, 51P
OUTPUT CONTACTS
Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life: 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg
MK
203A
Aux
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO NC
16
1
MK 203A
LOA
D
Typical Application Diagram
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO
AUX AUXMK 203A
NC
16
1 62 3 4 5
L N
9 10 11 12 13 14
7
15
8
COMNO
MK 202A
NC
16
1
R1
LOA
D
Combined IDMT Overcurrent & Earth Fault Relays
Ordering Information
MK203A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK203A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
Normal Inverse Case Dimensions
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
mFront
Side
Panel Cutout
96 m
m
Overcurrent R
elayM
K 203A
MK204A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK204A-240A : 198 ~ 265 V ACModel MK204A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical
SETTING RANGES
Low-set ( I > ) : 2.0 A to 6.0 A : 40% to 120%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous
echnical Data
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set inverse definite time relay (IDT)
• High-set instantaneous relay
• Separate low-set and high-set trip indicators
• Option to disable high-set relay
• Front panel access to test function
• Complies with IEC 60255-26 standard
• ANSI Code : 50P, 51P
OUTPUT CONTACTS
Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life: 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg
Overcurrent R
elayM
K 204A
Overcurrent R
elay
Aux
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO NC
16
1
MK 204A
LOA
D
Typical Application Diagram
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO
AUX AUXMK 204A
NC
16
1 62 3 4 5
L N
9 10 11 12 13 14
7
15
8
COMNO
MK 201A
NC
16
1
R1
LOA
D
Combined IDMT Overcurrent & Earth Fault Relays
Ordering Information
MK204A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK204A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
1.0
k
0.90.80.70.60.50.4
0.3
0.2
0.1
t/s
10
1
0.11 10 20 I/I>
Inverse Definite Time Case Dimensions
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
mFront
Side
Panel Cutout
96 m
m
MK
204A
MK231A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK231A-240A (6) : 198 ~ 265 V ACModel MK231A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical
SETTING RANGES
Low-set ( I > ) : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%Low-set definite time ( t > ) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99)High-set ( I >> ) : 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
OUTPUT CONTACTS
Rated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display
and red indicators
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.7 kg
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set earth-fault
• High-set earth-fault
• Local display of measured and set values
• Definite time for low-set and high-set
• Non-volatile fault value recording
• Programmable relay outputs
• Complies with IEC 60255-26 standard
• ANSI Code : 50N, 51N
Earth Fault R
elayM
K 231A
Earth Fault R
elay
Aux
62 3 4 5
L
R1 R2
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
1
MK 231A
L1
L2
L3
N
LOA
D
Typical Application Diagram 1 Typical Application Diagram 2
Ordering Information
MK231A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK231A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK231A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK231A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
Case Dimensions
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
Aux
62 3 4 5
L
R1 R2
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
1
MK 231A
Core BalanceCurrent Transformer
L1
L2
L3
N
MK
231A
Typical Application Diagram 2Aux
62 3 4 5
L
R1
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
R2
1
MK 232A
Core BalanceCurrent Transformer
L1
L2
L3
N
MK232A
Technical Data
RATINGSRated current ( In ) : 5 ARated frequency : 50 or 60 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLYModel MK232A-240A (6) : 198 ~ 265 V ACModel MK232A-110A (6) : 94 ~ 127 V ACSupply frequency : 50 or 60 HzVA rating : 3 VA typical
SETTING RANGESLow-set ( I > ) : 0.1 A to 5.0 A, step 0.05 A / 2% to 100%, step 1%Low-set time multiplier ( kt > ) : 0.05 to 1.0, step 0.01Low-set definite time (t >) : 0.05 to 99 sec, step 0.01 (0.05 to 1.0) / 0.1 (1.0 to 99) High-set ( I >> ) : 0.1 A to 50 A or disable, step 0.1 A / 2% to 1000%, step 2%High-set delay time ( t >> ) : 0.05 sec to 2.5 sec, step 0.01
ACCURACYProtection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
OUTPUT CONTACTSRated voltage : 250 V AC / DCContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSAuxiliary supply : Green indicatorPick-up : Red indicatorTrip : 7-segment display
and red indicators
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Enclosure protection : IP54 at the panelApproximate weight : 0.7 kg
Typical Application Diagram 1Aux
62 3 4 5
L
R1
N
9 10 11 12 13 14
7
15
8
COMNO NC COM NC NO
16
R2
1
MK 232A
L1
L2
L3
N
LOA
D
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set earth-fault
• High-set earth-fault
• Local display of measured and set values
• Definite time for low-set and high-set
• Non-volatile fault value recording
• Programmable relay outputs
• Five selectable IDMT characteristic curves
• Complies with IEC 60255-26 standard
• ANSI Code : 50N, 51N
Earth Fault R
elayM
K 232A
Earth Fault R
elay
Normal Inverse 1.3/10
Very Inverse
Case Dimensions
Ordering Information
Normal Inverse
MK232A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK232A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK232A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK232A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
Long Time Inverse
Extremely Inverse
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
MK
232A
MK201A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK201A-240A : 198 ~ 265 V AC Model MK201A-110A : 94 ~ 127 V AC Supply frequency : 50 HzVA rating : 3 VA typical
SETTING RANGES
Low-set ( I > ) : 0.1 A to 2.0 A : 2% to 40%Low-set delay time(DELAY): 0.05 sec to 1.0 secHigh-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time ( t >> ) : Instantaneous
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
OUTPUT CONTACTS
Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set definite time relay
• High-set instantaneous relay
• Separate low-set and high-set indicators
• Option to disable the high-set relay
• Front panel access to the test function
• Complies with IEC 60255-26 standard
• ANSI Code : 50N, 51N
Earth Fault R
elayM
K 201A
Case Dimensions
Earth Fault R
elay
Aux
62 3 4 5
L
R1
N
9 10 11 12 13 14
7
15
8
COMNO NC
16
1
MK 201A
L1
L2
L3
N
LOA
D
Typical Application Diagram
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO
AUX AUXMK 204A
NC
16
1 62 3 4 5
L N
9 10 11 12 13 14
7
15
8
COMNO
MK 201A
NC
16
1
R1
LOA
D
Combined IDMT Overcurrent & Earth Fault Relays
96 mm
Front
96 m
m
90 mm70 mm
Side
91.0 ± 0.5 mm91
.0 ±
0.5
mm
Panel Cutout
Ordering Information
MK201A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK201A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTIONM
K 201A
MK202A
Technical Data
RATINGS
Rated current ( In ) : 5 ARated frequency : 50 HzBurden : < 0.3 VA at InThermal withstand : 4 x In continuous
AUXILIARY SUPPLY
Model MK202A-240A : 198 ~ 265 V ACModel MK202A-110A : 94 ~ 127V ACSupply frequency : 50 HzVA rating : 3 VA typical
SETTING RANGES
Low-set ( I > ) : 0.1A to 2.0 A : 2% to 40%Time multiplier ( TM ) : 0.05 to 1.0High-set ( I >> ) : I > to 10 x I > or disableHigh-set delay time (t >>) : Instantaneous
ACCURACY
Protection thresholds : ± 5%Time delay : ± 5% with a minimum
of 50 ms
OUTPUT CONTACTS
Trip contact (R1) : Manual reset typeRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
TIME CURRENT CHARACTERISTIC CURVE
- Normal Inverse
INDICATORS
Auxiliary supply : Green indicatorPick-up : Red indicatorTrip : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg
Features
• Microprocessor based numerical relay
• Current measurement based on fundamental frequency
• Low-set inverse definite minimum time ( IDMT ) relay
• High-set instantaneous relay
• Separate low-set and high-set trip indicators
• Option to disable high-set element
• Front panel access to test function
• Complies with IEC 60255-26 standard
• ANSI Code : 50N, 51N
Earth Fault R
elayM
K 202A
Earth Fault R
elay
Aux
62 3 4 5
L
R1
N
9 10 11 12 13 14
7
15
8
COMNO NC
16
1
MK 202A
L1
L2
L3
N
LOA
D
Typical Application Diagram
62 3 4 5
L
R1
N
L1
L2
L3
N
9 10 11 12 13 14
7
15
8
COMNO
AUX AUXMK 203A
NC
16
1 62 3 4 5
L N
9 10 11 12 13 14
7
15
8
COMNO
MK 202A
NC
16
1
R1
LOA
D
Combined IDMT Overcurrent & Earth Fault Relays
Ordering Information
MK202A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK202A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
Normal Inverse Case Dimensions
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
mFront
Panel Cutout
96 m
m
90 mm70 mm
Side
MK
202A
MK300AMK300EA
Technical Data
AUXILIARY SUPPLYModel MK300A / 300EA -230A : 184 ~ 276 V ACModel MK300A / 300EA -110A : 94 ~ 127 V ACRated frequency : 50 HzVA rating : 3 VA typical
SETTINGSensitivity adjustment : 30mA, 50mA,
0.10~1.00A(Step=50mA) 1.00~10.0A (Step=1.00A)
Time delay adjustment : Instantaneous, 0.1~3.0sec (Step=0.1s)
PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%
RECORDFault record : 3 latest tripped fault
currents or “tSt” for manual test trip
Storage : Non-volatile memory
INPUT Remote Reset : N.O. dry contact *
OUTPUTS Trip contact : Activated during leakage
trip, manual test trip or ZCT connection error
Positive safety contact*: Activated when power-up and relay function correctly
Alarm contact* : Activated when measured leakage current exceeded 50% of IΔn.
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)
3 A (NC)Expected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSPre-fault alarm : Red indicator
(Normal blink)Time delay : Red indicator
(Fast blink)Leakage trip : 7-segment display
and red indicatorZCT connection error : 7-segment display
and red indicatorReal-time leakage current : 7-segment display
ZERO - PHASE CURRENT TRANSFORMERTo operate with Mikro’s ZCT series of current transformer
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 0.4 kg (excluding ZCT)
Features for MK 300A / 300EA
• Numerical earth leakage relay
• Programmable current sensitivity and time delay
• Detection of no connection to ZCT
• Relay trip indicator
• Relay alarm indicator
• Real-time leakage current display
• 50% pre-fault indicator
• Leakage fault current recording
• Standard DIN 96x96mm panel mounting
• Protected against nuisance tripping
Features for MK 300EA only
• Positive safety output contact
• Pre-fault alarm contact
• Remote reset function
Earth Leakage R
elayM
K 300A
/ 300EA
MK 300EA
MK 300A
Earth Leakage R
elay
TRIPCONTACT
62 3 4 5 71
9 11 12 13 14 15
LNAUX
8
1610
LOAD
SHUNTTRIP
L1 L2 L3 N PE
MIKROZCT
MK300A
COMNONC
The EARTH wire must not pass through the ZCT
Typical Application Diagram For MK300A
Typical Application Diagram For MK300EA
TRIPCONTACT
62 3 4 5 71
9 11 12 13 14 15
LNAUX
8
1610
POSITIVE SAFETY CONTACT
LOAD
COM
L1 L2 L3 N PE
MK300EA
ALARMCONTACT
REMOTE RESET
CONTACTOR
MIKROZCT
NONCCOMNONC COMNO
The EARTH wire must not pass through the ZCT
Ordering Information
MK300A - 240AD For 50Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300EA - 240AD For 50Hz system, auxiliary voltage 85~265VAC or 110~340VDC MK300A - 230A For 50Hz system, auxiliary voltage 184~276VACMK300EA - 230A For 50Hz system, auxiliary voltage 184~276VACMK300A - 110A For 50Hz system, auxiliary voltage 94~127VACMK300EA - 110A For 50Hz system, auxiliary voltage 94~127VAC MK300A - 240AD6 For 60Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300EA - 240AD6 For 60Hz system, auxiliary voltage 85~265VAC or 110~340VDCMK300A - 230A6 For 60Hz system, auxiliary voltage 184~276VACMK300EA - 230A6 For 60Hz system, auxiliary voltage 184~276VACMK300A - 110A6 For 60Hz system, auxiliary voltage 94~127VACMK300EA - 110A6 For 60Hz system, auxiliary voltage 94~127VAC
MODEL DESCRIPTION
Case Dimensions
MK
300A / 300E
A
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Panel Cutout
96 m
m
90 mm70 mm
Side
MK330A
Technical Data
AUXILIARY SUPPLYModel MK330A-230A : 184~276VACModel MK330A-110A : 94~127VACRated frequency : 50HzVA rating : 3VA typical
PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%
SETTINGSensitivity adjustment : 30mA, 50mA,
0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A)
Time delay adjustment: Instantaneous, 0.1~3.0sec (Step=0.1s)
Number of shots : 0~30 (Step=1, 0=Disable auto re-close function)
Dead time : 1~500sec (Step=1sec)
Persistent fault time : 0~500sec (Step=1sec, 0=Disable function)
Reclaim time : 0~500min (Step=1min, 0=Disable function)
Lockout auto reset time: 0~200hour (Step=1Hr, 0=Disable function)
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)
3 A (NC)Expected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSPre-fault alarm : Red indicator (Normal
blink)Time delay : Red indicator (Fast blink)Leakage trip : 7-segment display and
red indicatorRe-close lockout : 7-segment display and
red indicatorZCT connection error : 7-segment display and
red indicatorReal-time leakage current : 7-segment display
ZERO-PHASE CURRENT TRANSFORMERTo operate with Mikro’s ZCT series of current transformer
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 0.6 kg (excluding ZCT)
Programmable contact: Option 0 = Disable Option 1 = All (Option
2 to 6) Option 2 = ZCT error
Option 3 = Leakage trip, test trip,
re-close lockout Option 4 =Re-close
lockout Option 5 = Pre-fault alarm, leakage trip, test trip, re-close lockout
Option 6 = Re-close lockout, ZCT error
RECORDFault record : 3 latest tripped fault
currents or “tSt” for manual test trip
Storage : Non-volatile memory
INPUTRemote reset : N.O. dry contact
OUTPUTSTrip safe contact : Activated when the relay
is in normal power-up condition with the measured leakage current less than 0.85 IΔn.
Programmable contact: Activated according to user setting
Earth Leakage R
elayM
K 330A
Features
• Numerical auto-reclosing earth leakage relay
• Incorporated positive safety feature into trip contact
• One programmable contact for flexibility
• Detection of no connection to ZCT
• Relay trip / alarm indicator
• Real-time leakage current display
• Leakage fault current recording
• Remote reset function
• Standard DIN 96 x 96mm panel mounting
• Protected against nuisance tripping
Earth Leakage R
elay
Ordering Information
MK330A-230A For 50Hz system, auxiliary voltage 184~276VAC
MK330A-110A For 50Hz system, auxiliary voltage 94~127VAC
MK330A-230A6 For 60Hz system, auxiliary voltage 184~276VAC
MK330A-110A6 For 60Hz system, auxiliary voltage 94~127VAC
MODEL DESCRIPTION
Case Dimensions Typical Application Diagram
TRIP SAFECONTACT*
62 3 4 5 71
9 11 12 13 14 15
LNAUX
8
1610
PROGRAMMABLE CONTACT
LOAD
COM
L1 L2 L3 N PE
MK330A
REMOTE RESET
CONTACTOR
MIKROZCT
NONCCOMNONC
The EARTH wire must not pass through the ZCT
* The trip safe contact is activated (terminal 10-11 closed) when
the relay is in normal power-up condition with the measured
leakage current less than 0.85 IΔn.
MK
330A
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Panel Cutout
96 m
m
90 mm70 mm
Side
MK302AMK301AMK301E
Technical Data
AUXILIARY SUPPLY
Model MK301A / 302A -240A : 198 ~ 265 V ACModel MK301A / 302A -110A : 94 ~ 127 V ACRated frequency : 50 / 60 HzVA rating : 3 VA typical
SETTING RANGES
Sensitivity adjustment : 0.03 A to 30 ADelay time adjustment : 0 sec to 3.0 sec
PERFORMANCE
Setting accuracy : -15% to +0%Timing accuracy : ±5%
OUTPUT CONTACTS
Contact arrangement : 1 x manual reset type : 1 x safety contact* : NC and NO contacts
availableRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INPUTS
Remote Test* / Reset Inputs* : N.O. dry contact
INDICATORS
Auxiliary supply : Green indicatorTime delay : Red indicatorTrip : Red indicatorReal-time leakage current : Red indicator
Features
• Trip starting indicator
• Detection of no connection to current transformer for extra safety
• Relay tripped indicator
• High immunity to electrical interference
Features for MK 302A only
• Safety output contact
• Earth leakage level indicators
• Remote reset and remote test functions
Earth Leakage R
elayM
K 302A
/ 301A / 301E
ZERO - PHASE CURRENT TRANSFORMER
To operate with Mikro’s ZCT series of current transformer
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg (excluding ZCT)
* Applicable to MK302A series only
** Applicable to MK301E series only
MK 302A
MK 301A
MK 301E
Earth Leakage R
elay
Typical Application Diagram
L1
L2
L3
N
2 3 4 5 6
10
1
9 11 12 13 14
7
15
8
16
L NAUX
TRIP CONTACT
MK301A or MK302A
LOAD
SHUNTTRIP
NO NC COM
PE
The EARTH wire must not pass through the ZCT
L1
L2
L3
N
1 2 3 4 5 6
9 10 11 12 13 14
7
15
8
16
L NAUX
TRIP CONTACT
LOAD
CONTACTOR
SAFETY CONTACT*
REMOTETEST*
REMOTE RESET*
COM COM NCNC NONO
PE
The EARTH wire must not pass through the ZCT
MK302A
L1
L2
L3
N
1 2 3 4 5 6
9 10 11 12 13 14
7
15
8
16
L NAUX
TRIP CONTACT TRIP CONTACT 2**
LOAD
SHUNTTRIP
NO NC COM NC NOC OM
PE
The EARTH wire must not pass through the ZCT
MK301E
Case Dimensions
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Panel Cutout
96 m
m
90 mm70 mm
Side
Ordering Information
MK301A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V AC MK301A - 110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK302A - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK302A -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK301E - 240A For 50 Hz system, auxiliary voltage 198 ~ 265 V ACMK301E -110A For 50 Hz system, auxiliary voltage 94 ~ 127 V ACMK301A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V AC MK301A - 110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V ACMK302A - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK302A -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V ACMK301E - 240A6 For 60 Hz system, auxiliary voltage 198 ~ 265 V ACMK301E -110A6 For 60 Hz system, auxiliary voltage 94 ~ 127 V AC
MODEL DESCRIPTION
MK
302A / 301A
/ 301E
DIN330
Technical Data
AUXILIARY SUPPLYModel DIN330-230 A(6) : 184 ~ 276 V ACRated frequency : 50 or 60 HzVA rating : 3 VA typical
PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%
SETTINGSensitivity adjustment : 30 mA, 50 mA, 0.10 A –1.00 A
(Step = 50 mA), 1.00 A – 10.0 A
(Step = 1.00 A)Time delay adjustment: Instantaneous,
0.1s – 3.0s Step = 0.10 sec.
Number of shots : 0 - 30. Step = 1. 0 = Disable auto reclose function
Dead time : 1 - 500 sec. Step = 1 sec.
Permanent fault time : 0 - 500 sec. Step = 1 sec. 0 = Disable function
Reclaim time : 0 - 500 minute Step = 1 min 0 = Disable function
Lockout auto reset time: 0 - 200 hour Step = 1 Hrs 0 = Disable function
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO) 3 A (NC)Expected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORS50% pre-fault alarm : Red indicator (Normal
blink)Time delay : Red indicator (Fast blink)Leakage trip : 7-segment display and
red indicatorReclose lockout : 7-segment display and
red indicatorZCT fault : 7-segment display and
red indicatorReal time leakage current : 7-segment display
To operate with Mikro’s ZCT series of current transformer
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : Panel mountingDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg (excluding ZCT)
Programmable contact : Option 0 = Disable Option 1 = All (Option 2 to 6) Option 2 = ZCT error Option 3 = Leakage trip, test trip, re-close lockout Option 4 = Re-close lockout Option 5 = Pre-fault alarm, leakage trip, test trip, reclose lockout Option 6 =Re-close lockout, ZCT error
RECORDFault record : 3 latest tripped fault
currents or “tSt” for manual test trip
Storage : Non-volatile memory
INPUTRemote reset : N.O. dry contact
OUTPUTSTrip safe contact : Activated when the relay
is in normal power-up condition with the
measured leakage current less than 0.85 IΔn.
Programmable contact: Activated according to user setting
Earth Leakage R
elayD
IN 330
Features
• Numerical auto-reclosing earth leakage relay
• Incorporated positive safety feature into trip contact
•
• Detection of no connection to ZCT
• Relay trip / alarm indicator
• Real-time leakage current display
• Leakage fault current recording
• Remote reset function
• Standard 35mm DIN rail mounting
• Protected against nuisance tripping
Earth Leakage R
elay
Ordering Information
DIN330 - 230 A For 50 Hz system, auxiliary voltage 230 V AC DIN330 - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC
MODEL DESCRIPTION
Case Dimensions
Front
Side
71 mm
20 mm
45 mm
20 mm
70 mm
85 mm
30 mm 20 mm 20 mm
TRIP SAFE CONTACT PROGRAMMABLE CONTACT
LOAD
L1
L2
L3 N
62 3 4 5 71
8 9 10 11 12 13 14
L NAUX
CONTACTOR
MIKROZCT
DIN330
REMOTERESET
COM NO NC COM NO NC
PE
The EARTH wire must not pass through the ZCT
Typical Application Diagram
* The trip safe contact is activated (terminal 9-10 closed) when
the relay is in normal power-up condition with the measured
leakage current less than 0.85 IDn.
DIN
330
DIN310DIN310E
Technical Data
AUXILIARY SUPPLYDIN310-230 A(6) : 184 ~ 276 V AC DIN310E-230 A(6) : 184 ~ 276 V ACRated frequency : 50 or 60 HzVA rating : 3 VA typical
PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%
SETTINGSensitivity adjustment : 30mA, 50mA,
0.10~1.00A (Step=50mA) 1.00~10.0A (Step=1.00A)
Time delay adjustment: Instantaneous, 0.1~3.0sec
Step=0.10 sec
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 A (NO)
3 A (NC)Expected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
RECORDFault record : 3 latest tripped fault
currents or “tSt” for manual test trip
Storage : Non-volatile memory
INPUTRemote reset* : N.O. dry contact
OUTPUTSTrip Contact : Activated if relay tripped
or ZCT faultPositive safety contact* : Activated when ZCT is
connected properly to the relay
Pre-fault alarm contact*: Activated when leakage current exceeded 50% of sensitivity setting
INDICATORS50% pre-fault alarm : Red indicatorTime delay : Red indicatorLeakage trip : 7-segment display and red
indicatorZCT fault : 7-segment display and red
indicatorReal time leakage current: 7-segment display
Earth Leakage R
elayD
IN 310 / 310E
Features
• Numerical earth leakage relay
• Programmable current sensitivity and time delay
• Detection of no connection to ZCT
• Relay trip indicator
• Relay alarm indicator
• Real-time leakage current display
• Leakage fault current recording
• 50% pre-fault indicator
• Standard DIN rail mounting
• Protection against nuisance tripping
Features For DIN 310E only
• Positive safety output contact
• 50% pre-fault output contact
• Remote reset function
To operate with Mikro’s ZCT series of current transformer
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : Panel mountingDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg (excluding ZCT)
* Applicable to DIN310E series only
Case Dimensions
Earth Leakage R
elay
Ordering Information
DIN310 - 230 A For 50 Hz system, auxiliary voltage 230 V AC DIN310E - 230 A For 50 Hz system, auxiliary voltage 230 V ACDIN310 - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC DIN310E - 230 A6 For 60 Hz system, auxiliary voltage 230 V AC
* 60Hz system, auxiliary voltage 110V AC model available upon special request.
MODEL DESCRIPTION
Front
Side
71 mm
20 mm45 m
m
20 mm
70 mm
85 mm
30 mm 20 mm 20 mmTRIP CONTACT SAFETY CONTACT
LOAD
L1
L2
L3 N
62 3 4 5 71
8 9 10 11 12 13 14
L NAUX
CONTACTOR
MIKROZCT
DIN310E
REMOTERESET
ALARM CONTACT
NO NC NCCOM COM NO
PE
The EARTH wire must not pass through the ZCT
TRIPCONTACT
LOAD
L1
L2
L3 N
62 3 4 5 71
8 9
COM NO NC
10 11 12 13 14
L NAUX
SHUNTTRIP
MIKROZCT
DIN310
PE
The EARTH wire must not pass through the ZCT
Typical Application Diagram For DIN 310E
Typical Application Diagram For DIN 310
DIN
310 / 310E
DIN300DIN300E
Technical Data
AUXILIARY SUPPLYModel DIN300 / 300E -240A : 198 ~ 265 V ACModel DIN300 / 300E -110A : 94 ~ 127 V ACRated frequency : 50 / 60 HzVA rating : 3 VA typical
SETTING RANGESSensitivity setting : 30 mA, 50 mA, 75 mA,
100 mA, 125 mA, 150 mA, 200 mA, 250 mA, 300 mA, 500 mA, 750 mA, 1 A, 1.25 A, 1.5 A, 2 A, 2.5 A, 3 A, 5 A, 7.5 A, 10 A, 12.5 A, 15 A, 20 A, 25 A, 30 A.
Time delay setting : Instantaneous, 50 ms, 100 ms, 150 ms, 250 ms, 350 ms, 500 ms, 1 s, 3 s.
PERFORMANCESetting accuracy : -15% to +0%Timing accuracy : ±5%
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : DIN rail mountingDimension (mm) : 71(w) x 85(h) x 70(d)
Approximate weight
:
0.4 kg (excluding ZCT)
* Applicable to DIN300E model only
OUTPUT CONTACTSContacts ( Trip / 50% pre-fault* )Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INPUTRemote test* / Reset inputs* : N.O. dry contacts
To operate with Mikro’s ZCT series of current transformer
INDICATORSAuxiliary supply : Green indicatorTime delay : Red indicatorTrip : Red indicatorLeakage current* : 5 red indicators for
leakage levels
Earth Leakage R
elayD
IN 300 / 300E
Features
• 25 selectable sensitivity settings: 30 mA to 30 A
• 9 selectable time delays: 0ms to 3s
• Earth leakage level indicators
• Detection of no connection to ZCT
• Relay tripped indicator
• Trip starting indicator
• Protected against nuisance tripping
Features For DIN 300E only
• 50% pre-fault output contact
• Remote test and remote reset functions
Earth Leakage R
elay
Case Dimensions
Ordering Information
DIN300 - 240A For 50 Hz system, auxiliary voltage 240 V AC DIN300 - 110A For 50 Hz system, auxiliary voltage 110 V ACDIN300E - 240A For 50 Hz system, auxiliary voltage 240 V AC DIN300E - 110A For 50 Hz system, auxiliary voltage 110 V ACDIN300 - 240A6 For 60 Hz system, auxiliary voltage 240 V AC DIN300 - 110A6 For 60 Hz system, auxiliary voltage 110 V ACDIN300E - 240A6 For 60 Hz system, auxiliary voltage 240 V AC DIN300E - 110A6 For 60 Hz system, auxiliary voltage 110 V AC
MODEL DESCRIPTION
71mm
71mm
30mm 20mm 20mm
45mm
85mm
20mm
20mm
Front view
Side view
L1
L2
L3 N
1 2 3 4 5 6
8 9 10 11 12 13
7
14
L NAUX
S2
S1
TRIP CONTACT50% PRE-FAULT CONTACT
LOAD
SHUNTTRIP
REM
OTE
RES
ET
REM
OTE
TES
T
COMCOM NO NCNCNO
PE
The EARTH wire must not pass through the ZCT
L1
L2
L3 N
1 2 3 4 5 6
8 9 10 11 12 13
7
14
L NAUX
S2
S1
TRIP CONTACT
LOAD
SHUNTTRIP
COM NO NC
PE
The EARTH wire must not pass through the ZCT
Typical Application Diagram For DIN 300E
Typical Application Diagram For DIN 300
DIN
300 / 300E
ZCT40SZCT60SZCT80SZCT120SZCT210S
B
A C
D
G
F
E
Front
Bottom
DIMENSION
(mm) ZCT Model
40S 60S 80S 120S 210S
A 40 60 80 120 210 B 89 105 130 180 310 C 94 110 135 195 311 D 6 6 6 6 6 E 37 37 37 37 37 F 75 87 112 159 292 G 27 27 27 27 18
Earth Leakage R
elayZC
T 40S / 60S
/ 80S / 120S
/ 210S
Case Dimensions
Calculation to determine Inner Diameter of ZCT required
Ordering Information
ZCT 40S 40 14 12 ZCT 60S 60 23 21 ZCT 80S 80 32 29 ZCT 120S 120 51 46 ZCT 210S 210 93 83
ZCT40S 40mm inner diameter 0.16 kgZCT60S 60mm inner diameter 0.20 kgZCT80S 80mm inner diameter 0.28 kgZCT120S 120mm inner diameter 0.57 kgZCT210S 210mm inner diameter 1.5 kg
D d3, 3 wire d4, 4 wire
MODEL ZCT inner Up till wire Up till wire diameter (mm) diameter (mm) diameter (mm)
MODEL DESCRIPTION WEIGHT
40S
60S
80S
120S 210S
D
d3
3 wire
D
d4
4 wire
Example:
For a single core CU / PVC insulated, non-sheathed 450 / 750 V 50mm2 conductor, it’s nominal overall diameter is 11.7mm. To pass 4 wires through the ZCT, we can use ZCT40S as the maximum diameter it can support is up till 12mm.
DVMFeatures
• Built-in selector switch
• Easy-to-read, 14.2mm digit display
• DIN size casing
Technical Data
Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V ACVA rating : 3 VAInput frequency : 47 ~ 66 HzMaximum input voltage : 500 VrmsApproximate weight : 0.6 kg
Digital P
ower M
eter
Aux SupplyAC 240 V
DVM360 Series
62 3 4 5
L1
L2
L3
N
7 8 9 10 11 12
1
Typical Application Diagram
Aux SupplyAC 240 V
DVM100 Series
62 3 4 5
7 8 9 10 11 12
1
L
N
Case Dimensions
96 m
m
96 mm
Front
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Panel Cutout
91.5 mm
87 mm
Side
Ordering Information
DVM360 - 240A Auxiliary voltage 240 V AC DVM100 - 240A Auxiliary voltage 240 V ACDVM360 - 110A Auxiliary voltage 110 V ACDVM100 - 110A Auxiliary voltage 110 V AC
MODEL DESCRIPTION
DVM3VV
L1
L2
L3
N
TypypiTT cal Apppplic
DV
M
DAMFeatures
• Built-in selector switch
• Easy-to-read, 14.2mm digit display
• DIN size casing
• Wide selection of current transformer (CT) ratio
Technical Data
Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V ACVA rating : 3 VAInput frequency : 47 ~ 66 HzMaximum input : 6 A continuousAmmeter CT ratio : .../5 AClass : 1.0Approximate weight : 0.7 kg
Aux SupplyAC 240 V
DAM330 / 3000 Series
62 3 4 5
L1
L2
L3
7 8 9 10 11 12
1
Typical Application Diagram
Aux SupplyAC 240 V
DAM100 / 1000 Series
62 3 4 5
7 8 9 10 11 12
1
L
N
Case Dimensions
96 m
m
96 mm
Front
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Panel Cutout
91.5 mm
87 mm
Side
L1
TypypiTT cal App
Digital P
ower M
eterD
AM
For primary current from 60 A to 500 A
DAM 330 - XXXXDAM 100 - XXXX
Order number
Example: Model DAM 330 - 0060 for digital ammeter with CT ratio 60 / 5 A.
0060
ORDER NUMBERModel DAM 330 & DAM 100
*CT RATIO
60 / 5 A
0100 100 / 5 A
0150 150 / 5 A
0200
0250
0300
0400
0500
200 / 5 A
250 / 5 A
300 / 5 A
400 / 5 A
500 / 5 A
For primary current from 600 A to 5000 A
DAM 3000 - XXXXDAM 1000 - XXXX
Order number
600
ORDER NUMBERModel DAM3000 & DAM1000
*CT RATIO
600 / 5 A
800 800 / 5 A
1000 1000 / 5 A
1200
1500
1600
2000
2400
1200 / 5 A
1500 / 5 A
1600 / 5 A
2000 / 5 A
2400 / 5 A
2500 2500 / 5 A
3000 3000 / 5 A
3200 3200 / 5 A
3500 3500 / 5 A
4000 4000 / 5 A
4500 4500 / 5 A
5000 5000 / 5 A
*CT : Current Transformer For other CT ratio, please contact
the manufacturer.
DAM330 - xxxx - 240A
MODEL DESCRIPTION
Auxiliary voltage 240 V AC
DAM100 - xxxx - 240A Auxiliary voltage 240 V AC
DAM330 - xxxx - 110A Auxiliary voltage 110 V AC
DAM100 - xxxx - 110A Auxiliary voltage 110 V AC
DAM3000 - xxxx - 240A Auxiliary voltage 240 V AC
DAM1000 - xxxx - 240A Auxiliary voltage 240 V AC
DAM3000 - xxxx - 110A Auxiliary voltage 110 V AC
DAM1000 - xxxx - 110A Auxiliary voltage 110 V AC
DAM330
MODEL
/ SERIES
DAM3000
DAM100
WITH
SELECTOR
WITHOUT
SELECTOR
A
UNIT
A
A
A
DISPLAY
FORMAT
DAM1000
Ordering Information
Digital P
ower M
eterD
AM
DPM680FeaturesMeasurement Parameters: • Phase & Line Voltages (L-N) • Phase Current & Neutral Current • Bidirectional kW, kVAR & kVA• Bidirectional kWh, kVARh & kVAh• Frequency • Total & Displacement Power Factor• Voltage Total Harmonic Distortion• Current Total Harmonic Distortion• Avg. and Max. Thermal Current Demand• Avg. and Max. Power (kW, kVA, kVAR) Demand• Current Sequence Components• Voltage Sequence Components
TFT Colour LCD Display Serial RS-485 Modbus RTU Modbus TCP/IPBuilt-in WebserverVoltage & Current Waveform DisplayVoltage & Current Harmonics Display
Digital P
ower M
eter
Technical Data
WIRING SYSTEMS3-phase 4-wire system 3-phase 3-wire system
Nominal current : 5 A Min. measurement : 5 mA Accuracy : 0.2% of full scaleBurden : < 0.05 VA at 5 AMeasurement range : 10 APulsed withstand : 100 A for 1 secCT primary : 5 ~ 50,000 A
Nominal phase voltage : 0 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.2% at full scalePhase voltage via VT : 60 ~ 50,000 V
POWER MEASUREMENT Real power, apparent power, reactive power Accuracy : 0.5%
POWER FACTOR MEASUREMENT Total and displacement power factor Accuracy : 0.5%
POWER & THERMAL CURRENT DEMANDInterval : 1 ~ 30 mins
VOLTAGE AND CURRENT SEQUENCECOMPONENTSPositive, negative and zero sequence
FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Accuracy : 0.2%
ENERGY MEASUREMENT ACCURACYActive : IEC 62053-22 class 0.5 Reactive : IEC 62053-23 class 2
HARMONICS DISPLAY Fundamental up to 32nd order
VOLTAGE & CURRENT WAVEFORMDISPLAY Simultaneous 3-phase voltage orcurrent waveforms
COMMUNICATIONProtocol : Modbus RTU Interface : Isolated RS485
Protocol : Modbus TCP/IPInterface : Ethernet 10M/100M BaseT
Protocol : HTTP ServerInterface : Ethernet 10M/100M BaseT
AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : 3W typicalSustained overload : 500 V AC
ENVIRONMENTAL CONDITIONSOvervoltage category : IVPollution degree : 2Operating temperature : -10˚C ~ +55˚C Storage temperature : -20˚C ~ +70˚CHumidity : 0 – 95%,
non condensing
MECHANICAL Mounting : according to DIN 43700 /
ANSI C39.1Dimension (mm) : 96(w) x 96(h) x 100(d) Enclosure protection : IP63 at the panel
IP20 at the bodyApproximate weight : 0.5 kg
DP
M 680
Ordering Information
Test Standards
DPM 680-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC
Safety requirements.
EMC requirements.
MODEL DESCRIPTION
IEC 61010-1
IEC 61326-1
Case DimensionsTypical Application Diagrams
101.6±0.5mm
91±0.5mm
91±0.5mm
Cut-Out Recommendations
Digital P
ower M
eter
3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input
3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs 3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input
3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
GND
l2
l1
S2
S1ln
Ln
L3L2L1 Ln
90~415 V AC /100~300 V DCAUX
RS 485Modbus-RTU
Ethernet
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
GND
l2
l1
S2
S1ln
Ln
L3L2L1 Ln
90~415 V AC /100~300 V DCAUX
RS 485Modbus-RTU
Ethernet
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
GND
l2
l1
S2
S1ln
Ln
L3L2L1
90~415 V AC /100~300 V DCAUX
RS 485Modbus-RTU
GND
Ethernet
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
l2
l1
S2
S1ln
Ln
L3L2L1
90~415 V AC /100~300 V DCAUX
RS 485Modbus-RTU
Ethernet
GND
LOAD
LOAD
LOAD
LOAD
Front
Rear
Side
96 mm
83 mm
17 mm
100 m
m
96 mm
90 mm
86 mmea
DP
M 680
DPM380DPM380B
Features
LCD display with back lighting
Modbus-RTU communication
(for DPM380 only)
MEASUREMENT PARAMETERS:
• Phase Voltage (L-N)
• Line Voltage (L-L)
• Phase Current and Neutral Current
• Bidirectional kW (per phase & total)
• Bidirectional kVAR (per phase & total)
• Bidirectional kVA (per phase & total)
• Frequency
• Power Factor (per phase & total)
• Energy (+ and - ) for kWh, kVARh and kVAh
• THD Phase Voltage ( L-N )
• THD Phase Current
• Active Power (kW) Demand
Technical Data
DISPLAY TYPELCD display
MEASUREMENTS3-phase 4-wire system 3-phase 3-wire system
CURRENT MEASUREMENTCT primary : 5 ~ 8000 ACT secondary : 5 AMinimum measurement : 5 mAAccuracy : 0.5% from 1A to 6 A (secondary)Burden : < 0.05 VA at 5 ASustained overload : 6 A
VOLTAGE MEASUREMENTNominal phase voltage : 20 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.5% at full scalePhase voltage via VT : 60 ~ 33,000 V
POWER MEASUREMENTReal power, apparent power, reactive power measurementMeasuring updating period : 1 sAccuracy : 1.0%
ACTIVE POWER DEMANDInterval : 1 ~ 30 mins
POWER FACTOR MEASUREMENTTotal and displacement power factor Accuracy : 1.0%
FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 HzMeasurement updating period : 1sAccuracy : 0.5%
ENERGY ACCURACYActive (according to IEC 62053-21) : class 1Reactive (according to IEC 62053-23) : class 2
AUXILIARY POWER SUPPLYAC voltage : 90 ~ 415 V ACFrequency : 50 / 60 HzDC voltage : 100 ~ 300 V DCPower consumption : <3 VA
COMMUNICATIONHardware interface : Isolated RS485Protocol : Modbus-RTUBaud rate : 2400, 4800, 9600, 19200, 38400
ENVIRONMENTAL CONDITIONSOperating temperature : -10˚C ~ +55˚CStorage temperature : -20˚C ~ +70˚C Humidity : 0 – 95%,
non condensing
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 100(d) Approximate weight : 0.5 kg
Digital P
ower M
eterD
PM
380 / 380B
• Maximum Active Power (kW) Demand
Typical Application Diagram
Ordering Information
Electromagnetic Compatibility (EMC)
DPM 380-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with RS 485DPM 380B-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC
Immunity for industrial environments.
Emission standard for industrial environments.
MODEL DESCRIPTION
Part 6-2: Generic Standards IEC61000-6-2
Part 6-4: Generic Standards IEC61000-6-4
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
GND
l2
l1
S2
S1ln
Ln
L3L2L1 Ln
90~415 V AC /100~300 V DCAUX
RS 485Modbus-RTU
* For DPM380 only
+
-
GND
3-PHASE 4-WIRE SYSTEM WITH 4 CTs CONNECTION
LOAD
L3
L2
L1
S2
S1
S2
S1
S2
S1
l3
GND
l2
l1
S2
S1ln
Ln
L3L2L1 Ln
90~415 V AC /100~300 V DCAUX
3-PHASE 4-WIRE SYSTEM WITH 3 CTs CONNECTION
RS 485Modbus-RTU
* For DPM380 only
+
-
GND
LOAD
Case Dimensions
Front
Rear
Side
96 mm
83 mm
17 mm
100 m
m1
96 mm
90 mm
86 mm
86 mm
ea
101.6±0.5mm
91±0.5mm
91±0.5mm
Cut-Out Recommendations
Digital P
ower M
eterD
PM
380 / 380B
DM38Features
LCD display with back lighting
Modbus-RTU communication
DIN rail type
MEASUREMENT PARAMETERS:
• Phase Voltage ( L-N )
• Line Voltage ( L-L )
• Phase Current
• Bidirectional kW (per phase & total)
• Bidirectional kVAR (per phase & total)
• Bidirectional kVA (per phase & total)
• Frequency
• Power Factor (per phase & total)
• Energy (+ and - ) for kWh, kVARh and kVAh
• THD Phase Voltage ( L-N )
• THD Phase Current
Technical Data
DISPLAY TYPELCD display
MEASUREMENTS3-phase 4-wire system
CURRENT MEASUREMENTCT primary : 5 ~ 8000 ACT secondary : 5 AMinimum measurement : 10 mAAccuracy : 0.5% from 1A to 6 A (secondary)Burden : < 0.03 VA at 5 ASustained overload : 6 A
VOLTAGE MEASUREMENTNominal phase voltage : 70 ~ 300 V AC Minimum measurement : 10 V Accuracy : 0.5% at full scale
POWER MEASUREMENTReal power, apparent power, reactive power measurementMeasuring updating period : 1 sAccuracy : 1.0%
POWER FACTOR MEASUREMENTTotal and displacement power factor Accuracy : 1.0%
FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 HzMeasurement updating period : 1sAccuracy : 0.5%
ENERGY ACCURACYActive (according to IEC 62053-21) : class 1Reactive (according to IEC 62053-23) : class 2
POWER SUPPLYSelf supplied : 100 ~ 240 V ACFrequency : 50 / 60 HzPower consumption : <3 VA
COMMUNICATIONHardware interface : Isolated RS485Protocol : Modbus-RTUBaud rate : 2400, 4800, 9600, 19200, 38400
ENVIRONMENTAL CONDITIONSOperating temperature : -10˚C ~ +55˚CStorage temperature : -20˚C ~ +70˚CHumidity : 0 – 95%,
non condensing
MECHANICALMounting : DIN railDimension (mm) : 65(w) x 85(h) x 50(d)Approximate weight : 0.3 kg
Digital P
ower M
eterD
M 38
Digital P
ower M
eter
65 mm
85 mm
45.5 mm
71 mm
Front
15.5 mm
50 mm
Side
Case Dimensions
Typical Application Diagram
1 2 3 4 5 6
S1 S2 S1 S2 S1 S2
7 8 9 10 11
12 13 14 15 16 17 18 19 20 21 22
LnL3
L2
L1
RS 485Modbus-RTU
NOTE: Current transformer secondaryterminal MUST NOT be earthed.
S1P1
P2S2 DM38
120 Ohm
I1 I2 I3
L3L1 L2 Ln
DM 38 CONNECTION DIAGRAM
!X
+-GN
D
LOA
D
Ordering Information
Electromagnetic Compatibility (EMC)
DM 38-240A Self Powered 100~240 V AC
Immunity for industrial environments.
Emission standard for industrial environments.
MODEL DESCRIPTION
Part 6-2: Generic Standards IEC61000-6-2
Part 6-4: Generic Standards IEC61000-6-4
DM
38
MU2300 Features
• Multifunction numerical voltage protection relay
• time or inverse-time characteristic
• time
• or inverse-time characteristic
• time
• Negative sequence overvoltage protection (U2>)
• Neutral displacement / residual overvoltage protection (U0characteristic
• Can be used in single-phase or three-phase operation
• Multi-function isolated digital input with wide input voltage range
• Fault record and event code recording
• Five programmable voltage-free output contacts
• Isolated RS485 Modbus - RTU communication
• ANSI Code : 27, 47, 59, 60
Voltage Relay
MU
2300
Introduction
The MU2300 is a microprocessor based numerical relay for voltage protection functions in electrical distribution network.
Technical Data
INPUTS
Measuring input:
Rated voltage input : 57 ~ 130 VRated frequency : 50 / 60 Hz
Rated auxiliary voltage:
Model MU2300-150D : 24 ~ 150 V DCModel MU2300-240AD : 85 ~ 265 V AC
110 ~ 340 V DC
Power consumption:
AC auxiliary voltage : 6 ~ 10 VA typicalDC auxiliary voltage : 5 ~ 9 W typical
Binary Input:
External binary input : 85 ~ 265 V AC/DC
COMMUNICATION
RS485 Modbus - RTU
OUTPUT CONTACTS
5 programmable contacts +1 IRF contact:
Rated voltage : 250 V AC / DCContinuous carry : 5 AMake and carry for 0.2 s : 30 AExpected electrical life : 100,000 operations
at rated currentExpected mechanical life : 5 x 106 operations
UNDER-VOLTAGE ELEMENT
Low set setting U< : 5 - 130 VHigh set setting U<< : 5 - 130 VTime multiplier, TMS : 0.5 - 100
: 0 - 600 s : 0 - 600 s
OVER-VOLTAGE ELEMENT
Low set setting U> : 5 - 200 VHigh set setting U>> : 5 - 260 VTime multiplier, TMS : 0.5 - 100
: 0 - 600 ste time tU>> : 0 - 600 s
NEGATIVE SEQUENCE OVER-VOLTAGE
ELEMENT
Negative sequence over-voltage setting, U2> : 5 - 200 V
Time multiplier, TMS : 0.5 - 1002>
: 0 - 600 s
RESIDUAL OVER-VOLTAGE ELEMENT
Residual over-voltage setting, U0> : 0.5 - 130 VTime multiplier, TMS : 0.5 - 100
0>: 0 - 600 s
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 142(w) x 165(h) x 198(d)Enclosure protection : IP54 at the panelApproximate weight : 2.7 kg
Voltage Relay
11
1010
100100
00 0.10.1 0.20.2 0.30.3 0.40.4 0.50.5 0.60.6 0.70.7 0.80.8 0.90.9 11TMS=1
TMS=5
TMS=3
TMS=10
TMS=8
Applied voltage/relay setting voltageApplied voltage/relay setting voltage
Ope
rati
ng ti
me
(sec
)O
pera
ting
tim
e (s
ec)
Undervoltage Characteristic
0.01
0.1
1
10
100
0 2 4 6 8 10 12 14 16 18 20
TMS=1
TMS=8TMS=10
TMS=5TMS=3
Applied voltage/relay setting voltageApplied voltage/relay setting voltage
Ope
rati
ng ti
me
(sec
)O
pera
ting
tim
e (s
ec)
Overvoltage Characteristic
142 mm
165
mm
Front
129 1 mm
139
1 m
m
Panel Cutout
198 mm
34 mm
136
mm
Side
Typical Application Diagrams
3
2
6
5
9
8
12
11
31
3233
13
14
343635
3837
4039
4241
2726
283029
25
24
22
23
ExternalDigital
Input
Uaux
R1
R2
R3
R4
R5
AB
C
Trip Contact
A
BCPhase rotation
InternalRelayFailure
Termination ResistorN-
P+CommunicationCable Shield
3
2
6
5
9
8
12
11
31
3233
13
14
343635
3837
4039
4241
2726
283029
25
24
22
23
ExternalDigital
Input
Uaux
R1
R2
R3
R4
R5
AB
C
Trip Contact
A
BCPhase rotation
InternalRelayFailure
Termination ResistorN-
P+CommunicationCable Shield
3
2
6
5
9
8
12
11
31
3233
13
14
343635
3837
4039
4241
2726
283029
25
24
22
23
ExternalDigital
Input
Uaux
R1
R2
R3
R4
R5
AB
C
Trip Contact
A
BCPhase rotation
InternalRelayFailure
Termination ResistorN-
P+CommunicationCable Shield
3
2
6
5
9
8
12
11
31
3233
13
14
343635
3837
4039
4241
2726
283029
25
24
22
23
ExternalDigital
Input
Uaux
R1
R2
R3
R4
R5
AB
C
Trip Contact
A
BCPhase rotation
InternalRelayFailure
Termination ResistorN-
P+CommunicationCable Shield
3Vp-p + Vresidual connection 2Vp-p + Vresidual connection
3Vp-n + Vresidual connection 3Vp-n connection
Ordering Information
MU2300-150D For 50 / 60 Hz system, auxiliary voltage 24 ~ 150 V DC
MU2300-240AD For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110~340 V DC
MODEL DESCRIPTION
Case Dimensions
MU
2300
MU350
Technical Data
SETTING RANGESUndervoltage Time delay for undervoltage : 0.1s to 30sOvervoltage Time delay for overvoltage : 0.1s to 30sStart time delay : 0s to 999sUnbalance Time delay for unbalance : 0.5s to 30sPhase loss : Fixed time <0.5sPhase sequence : Fixed time <0.5s
AUXILIARY SUPPLYMU350-415V : 380 V (-25%) to 415 V (+20%) AC Supply frequency : 45 Hz to 65 HzMaximum power consumption: 3VA
MEASURING INPUTLine to line : 100 to 415 (+20%) VAC Line to Neutral : 58 to 240 (+20%) VAC
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSAuxiliary supply : Green indicatorPickup indicator : Red indicatorTrip : 7-segment display and
red LED indicators
ACCURACYProtection thresholds : ± 3%Time delay : 0 to 0.5s, ± 15% with
minimum 40ms : 0.6s and above, < ± 3%Measurements : ± 3%
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.31 kg
Product Description
MU350 is 3-phase voltage relay that combines various protections and starting delay.
Features
• Undervoltage
• Overvoltage
• Delay-on
• 2 voltage-free output contacts
• Voltage and frequency display
• 3-Phase
• Unbalance
• Phase loss
• Phase sequence
• With or without neutral connection
• Phase to phase or phase to neutral monitoring
• Programmable relay outputs
• ANSI Code : 27, 47, 59, 60
Voltage Relay
MU
350
Ordering Information
MU350-415V 3-Phase, auxiliary voltage 380 ~ 415 V AC, 45-65 HzMODEL DESCRIPTION
Voltage Relay
Typical Application Diagrams
MU
350
L1 N
R2R1
L-L 100-415V AC, L-N 58-240V AC
L2 L3
L1L2L3N
AUX
380-415V AC
(OPTIONAL)
NC NO COM NC NO COM
Case Dimensions
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Panel Cutout
96 m
m
90 mm70 mm
Side
MU250MU150
Technical Data
SETTING RANGESUndervoltage : 1% to 25%Time delay for undervoltage : 0.1s to 30sOvervoltage : 1% to 20%Time delay for overvoltage : 0.1s to 30sStart time delay : 0s to 999s
For MU250 only:Unbalance : 3% to 20%Time delay for unbalance : 0.5s to 30sPhase loss : Fixed time <0.5sPhase sequence : Fixed time <0.5s
POWER SUPPLY INPUTInput voltage:MU150-110V & MU250-110V : 100 V (-25%) to 120 V (+20%) ACMU150-240V & MU250-220V : 220 V (-25%) to 240 V (+20%) ACMU250-415V : 380 V (-25%) to 415 V (+20%)Supply frequency : 45 Hz to 65 Hz
Maximum power consumption:MU250 : 3VAMU150 : 2.5VA
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSAuxiliary supply : Green indicatorPickup indicator : Red indicatorTrip : 7-segment display and red
LED indicators
ACCURACYProtection thresholds : ± 3%Time delay : 0 to 0.5s, ± 15% with
minimum 40ms : 0.6s and above, < ± 3%Measurements : ± 3%
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.4 kg
Product Description
MU150 and MU250 are voltage relays that combine various protections and starting delay.
MU150 is used for single-phase monitoring while MU250 is used for 3-phase monitoring.
Features
• Microprocessor based numerical relay• Undervoltage• Overvoltage• Delay-on• 2 voltage-free output contacts• Voltage and frequency display• ANSI Code : 27, 47, 59, 60
Features For MU 250 only
• 3-Phase• Unbalance• Phase loss• Phase sequence• With or without neutral connection• Phase to phase or phase to neutral monitoring
MU 250
MU 150
Voltage Relay
MU
250 / 150
Ordering Information Case Dimensions
MU150-110V Single-Phase, 100/110/120 V AC, 45-65 Hz power supply
MU150-240V Single-Phase, 220/230/240 V AC, 45-65 Hz power supply
MU250-110V 3-phase, 100/110/120 V AC 45-65 Hz power supply
MU250-220V 3-phase, 220/230/240 V AC 45-65 Hz power supply
MU250-415V 3-Phase, 380/400/415 V AC, 45-65 Hz power supply
MODEL DESCRIPTION
Front
Side
71 mm
20 mm
45 mm
20 mm
70 mm
85 mm
30 mm 20 mm 20 mm
Voltage Relay
R2R1
62 3 4 5 71
8 9
COM NO NC COM NO NC
10 11 12 13 14
(OPTIONAL)
L1
L2
L3
N
MU250
(Neutral connection is optional)
Typical Application Diagrams
R2R1
62 3 4 5 71
8 9
COM NO NC COM NO NC
10 11 12 13 14
L
N
MU150
MU250 MU150
MU
250 / 150
MX210
Technical Data
POWER SUPPLY INPUT3-Phase SystemPhase-to-phase voltage : 380 V (-25%) to 415 V
(+20%) AC
Single Phase Phase-to-neutral voltage : 220 V (-25%) to 240 V
(+20%) ACFrequency range : 45 to 65 HzMax. power consumption : 3 VA maximum
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
SETTING RANGESUndervoltage : 78% - 98%Overvoltage : 102% - 122%Delay time : 0.1 - 10sNormal voltage : 380, 400, 415 Vpp, 220,
230, 240, Vpn3-phase / Single-phase
ACCURACY Protection thresholds : ± 3%Hysteresis : 1%Delay time : 0-0.5s, ± 15%,
40ms minimum : 0.5s and above, ± 3%Measurements : ± 3%
INDICATORSPower supply ON : Green indicatorOutput ON : Green indicatorUndervoltage : Red indicatorOvervoltage : Red indicatorPhase error : Red indicator
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.3 kg
Features
• Numerical voltage protection relay
• Undervoltage
• Overvoltage
• Phase loss
• Phase sequence
• 3-Phase/Single-phase
• ANSI Code: 27, 47, 59
Product Description
MX210 is voltage relay that combinesovervoltage, undervoltage, phase loss,phase sequence and delay start functions.
MX210 can be programmed by user toset nominal voltage as well as set into 3-phase or Single-phase mode.
3 - Phase Voltage R
elayM
X 210
3 - Phase Voltage R
elay
Case Dimensions Ordering Information
Wiring Diagram
Operations Diagram
Single-Phase System
i ) Over Voltage Function
3-Phase System
ii ) Under Voltage Function
T
Over Voltage LimitHysteresis
RelayON
RYB
>U LED ON
T
Under Voltage Limit
Hysteresis
RelayON
<U LED ON
RYB
MX 210
1 2 3 4 5 6
8 9 10 11 12 13
7
14
R1
L
N
L1
L2
L3
N
1 2 3 4 5 6
8 9 10 11 12 13
7
14
R1
MX210 - 415V 3-Phase 380-415V AC Single-Phase 220-240V AC 45-65Hz
MODEL DESCRIPTION
Front Side
71 mm
20 mm
45 mm
20 mm
70 mm
85 mm
30 mm 20 mm 20 mm
MX200AMK180AMK160AMX 200A
Under & Over Voltage Relay
MX 180AOver Voltage Relay
MX 160AUnder Voltage Relay
Technical Data
POWER SUPPLY INPUT3-Phase SystemPhase-to-phase voltage : 380 V AC ± 20%
400 V AC ± 20% 415 V AC ± 20%
Single Phase Phase-to-neutral voltage : 220 V AC ± 20%
230 V AC ± 20% 240 V AC ± 20%
Frequency range : 45 to 65 HzMax. power consumption : 3 VA
Input ConnectionsFor 3-phase model : Phase L1, L2, L3 to
pin 5, 6, & 7 Neutral to pin 11For single-phase model : Phase L to pin 5, 6 &
7*** Neutral to pin 11
SETTING RANGESLower voltage limit * : 78% - 98%Upper voltage limit ** : 102% - 122%Delay time, T : 0.1 - 10s
HYSTERESIS ≤1% of rms - value
OUTPUT CONTACTSRated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORSPower supply ON : Green indicatorOutput ON : Red indicatorUnder voltage limit (U<) * : Red indicatorOver voltage limit (U>) ** : Red indicator
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICALMounting : Circular 11-pin plug-in
socketDimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.3 kg
* Applicable to MX160A and MX200A only
** Applicable to MX180A and MX200A only
*** For single phase connection, short pin 5,6 & 7
Features
• Electronic monitoring relay
• Voltage monitoring for single 3-phase system
• Phase failure monitoring
• Adjustable voltage limit
• Adjustable delay time
• Indicators for voltage fault
• Indicators for power and output ON
• ANSI Code : 27, 47, 59
Product Description
MX160A, MX180A & MX200A are single or 3-phase monitoring relays. The relays are designed for application where it required to maintain the voltage within set limits. A built-in adjustable time delay prevents nuisance tripping.
Voltage Relay
MX 200A
/ 180A / 160A
Voltage Relay
Case Dimensions Ordering Information
80 mm
72.5 mm
35 mm
MX160A - 380
MODEL
UnderVoltage
Monitoring
YES
MX160A - 400 YES
MX160A - 415 YES
OverVoltage
Monitoring
NO
NO
NO
SupplyVoltage
V AC
380
400
415
MX180A - 380 NO YES 380
MX180A - 400 NO YES 400
MX180A - 415 NO YES 415
MX200A - 380 YES YES 380
MX200A - 400 YES YES 400
MX200A - 415 YES YES 415
FUNCTION
Wiring Diagram
Operations Diagram
L3
L2
L1
N
5 6 78
9
10111
2
3
4
L
N
5 6 78
9
10111
2
3
4
Single-Phase System
i ) Over Voltage Function**
3-Phase System
ii ) Under Voltage Function*
T
Over Voltage LimitHysteresis
RelayON
RYB
>U LED ON
T
Under Voltage Limit
Hysteresis
RelayON
<U LED ON
RYB
MX 200A
/ 180A / 160A
MX100MK50MX 100
Phase Sequence &Phase Failure monitoring
MX 50Phase Failure monitoring
Technical Data
POWER SUPPLY INPUT
Phase-to-phase voltage : 230 V AC ±20% : 400 V AC ±20%Frequency range : 45 to 65 HzMax power consumption : 3 VAInput connections : Phase L1 to pin 5 Phase L2 to pin 6 Phase L3 to pin 7 Neutral (optional) to
pin 11
OUTPUT CONTACTS
Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORS
Power supply ON : Green indicatorOutput ON : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Circular 11-pin plug-in socket
Dimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.3 kg
Voltage Relay
MX 100 / 50
Features
• Electronic monitoring relay
• Phase sequence monitoring*
• Phase failure monitoring
• Plug-in type module
• Indicators for power and alarm status
• ANSI Code : 47
Product Description
This phase sequence and phase failure relay is designed for application where the 3-phase supply needs to be continuously monitored for proper sequencing and phase loss. Commonly used to protect a 3-phase motor.
Voltage Relay
MODEL
MX100 - 230
MX100 - 400
MX50 - 230
MX50 - 400
DESCRIPTION
Auxiliary voltage 184~276 V AC
Auxiliary voltage 320~480 V AC
Auxiliary voltage 184~276 V AC
Auxiliary voltage 320~480 V AC
Wiring Diagram
Function Table
Example 2
L3
L2
L1
N
5 6 78
9
10111
2
3
4
3 ~L3
Example 1
L2
L1
5 6 78
9
10111
2
3
4
3~
Condition
1
2
3
4
5
6
Pin 5
L1
Loss
L1
L1
L2
L3
Pin 6
L2
L2
Loss
L2
L1
L2
Pin 7
L3
L3
L3
Loss
L3
L1
Relay
ON
OFF
OFF
OFF
OFF
OFF
Remark
System healthy
Phase failure
Phase failure
Phase failure
Sequence fault*
Sequence fault** Applicable to MX100 model only
Case Dimensions Ordering Information
80 mm
72.5 mm
35 mm
MX 100 / 50
Technical Data
INPUT
Rated Phase-neutral voltage : 220V to 240V ACRated Phase-phase voltage : 380V to 415V ACRated frequency : 50 or 60 HzRated current (In) : 5ABurden : < 0.3 VA at InThermal withstand : 1.2 x Un , 2 x In continuous : 1.2 x Un , 10 x In for 3 secPower consumption : 3 VA maximum
OUTPUT CONTACTS
Rated voltage : 250 V AC/DCContact rating : 5 AExpected electrical life: 100,000 operations at
rated currentExpected mechanical life: 5 x 106 operations
SETTING RANGES
Range : 2% to 20% reverse current with 1% Hysteresis
Time delay : 0 sec to 20 sec3-Phase 4-wire (star) or 3-Phase 3-wire (delta)
ACCURACY
Protection thresholds Hysteresis : ± 3%Delay time : 1% : 0-0.5s, ± 15%, 40ms minimum.Measurements : 0.5s and above, ± 3% : ± 3%
INDICATORS
Auxiliary supply : Green indicatorDelay : Red indicatorTrip : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing
MECHANICAL
Mounting : DIN railDimension (mm) : 71(w) x 85(h) x 70(d)Approximate weight : 0.3 kg
Reverse P
ower R
elayR
PR
415A
RPR415AFeatures
• Reverse power monitoring
• 3-phase, 3 or 4-wire system
• Adjustable reverse power setting
• Adjustable tripping time delay
• Indicators for auxiliary power, trip delay and trip status
• Test button
• ANSI Code: 32
Product Description
RPR 415A relay is a directionally controlled timing relay used to protect AC generators from motoring. When such condition occurs and the reverse current exceeded the customer adjustable preset limit for a predetermined delay time, the trip relay operates to disconnect the circuit.
Reverse P
ower R
elay
Case Dimensions
Ordering Information
RPR415A 380-415Vpp AC / 220-240Vpn AC, 45-65Hz
3-Phase 4-wire / single-phase system 3-Phase 3-wire system
MODEL DESCRIPTION
Typical Application Diagram
RP
R 415A
Front Side
71 mm
20 mm
45 mm
20 mm
70 mm
85 mm
30 mm 20 mm 20 mm
L1
L2
L3
N
1 2 3 4 5 6
8 9 10 11 12 13
7
14
R1
S1 Generator3~
I
S1S2
L1
L2
L3
1 2 3 4 5 6
8 9 10 11 12 13
7
14
R1
S1 Generator3~
I
S1S2
415V
240V
Technical Data
INPUT
Rated voltage (Un) : 380 ~ 440 V ACRated current (In) : 5 ARated frequency : 50 or 60 HzOverload : 1.2 x Un , 2 x In continuous 1.2 x Un , 10 x In for 3 sec
OUTPUT CONTACTS
Rated voltage : 250 V AC/DCContact rating : 5 AExpected electrical life: 100,000 operations at
rated currentExpected mechanical life: 5 x 106 operations
SETTING RANGES
Range : 2% to 20% reverse current with 1% Hysteresis
Time delay : 0 sec to 20 sec
INDICATORS
Auxiliary supply : Green indicatorDelay : Red indicatorTrip : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 142(d)Approximate weight : 0.8 kg
Reverse P
ower R
elayR
PR
415
RPR415Features
• Reverse power monitoring
• 3-phase-4-wire system
• Adjustable reverse power setting
• Adjustable tripping time delay
• Indicators for auxiliary power, trip delay and trip status
• Test button
• ANSI Code : 32
Product Description
The RPR 415 relay is a directionally controlled timing relay used to protect AC generators from motoring. When such a condition occurs and the reverse current exceeded the customer adjustable preset limit and the current persists for a predetermined delay time, the trip relay operates to diconnect the circuit.
Reverse P
ower R
elay
Case Dimensions
142 mm
132 mm
Side
96 m
m
96 mm
Front
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Panel Cutout
Ordering Information
RPR415 Auxiliary voltage 380 ~ 440 V AC
MODEL DESCRIPTION
2 3 4 5 6 7 8
9 10 11 12 13 14 15
1
16
NC
P1
S1
COM
DIRECTION OF CURRENT FOR OPERATION
NO
L1
L2
L3
N
Typical Application Diagram
RP
R 415
Pow
er Factor Regulator
PFR
140 / 120 / 80 / 60
Technical Data
RATINGS AUXILIARY POWER SUPPLY
Current Supply voltage : 220~240 V AC / 380~415 V AC
Operating Limits : -15% + 10%Consumption : 10 VA maxRated frequency : 50 Hz or 60 Hz
OUTPUT CONTACTS
Numbers of outputs : 6 / 8 / 12 / 14 ( PFR60 / PFR80 / PFR120 / PFR140 )
Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operationsMax current for the common terminals : 12 A continuous
CURRENT INPUT
Rated current ( In ) : 5 AOperating Limits : 0.05 A to 6.5 ARated Frequency : 50 Hz or 60 Hz
CONTROL RANGE
Power factor setting : 0.8 Ind - 0.8 CapC/K setting : 0.03 - 1.20 / AutomaticSwitching sensitivity : 5 - 600 s/stepReconnection time for same step : 5 - 240 sTHD threshold : 0.20 - 3.00 ( 20% - 300% ) /
OFFSwitching Program : Automatic / Automatic
Rotate / 4-quadrant / Manual
: 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16
( Automatic if C/K set to Auto )
PFR140PFR120PFR80PFR60
Features
• Microprocessor based intelligent auto switching control
• Automatic C/K and rated step adjustment
• Automatic CT polarity correction
• Display of power factor, current & total harmonic distortion of current
• Programmable sensitivity
• Last step can be used as alarm/fan output
• Under/over voltage alarm, under/over compensate alarm & high harmonic distortion alarm
• User-friendly setting
• Complies with IEC 61000-6-2 standard
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 144(w) x 144(h) x 90(d)Enclosure protection : IP54 at the panelApproximate weight : 1.2 kg
MAIN
P1
P2
FUSE
K14 K13 K2 K1
24232221201918171615
14
13
12111098
14131211
7654321
10987654321
AUXVOLTAGE
CURRENT/ 5 A
Po
we
r F
act
or
Re
gu
lato
r
L1L2L3N
380~415 V AC
1615
14
13 AUXVOLTAGE
For 220~240 V AC Model Only
220~240 V AC
LOAD
Typical Application Diagram
Case Dimensions Ordering Information
144 mm
138 mm
138
mm
76 mm90 mm
144
mm
Front
Side
PanelCutout
MODEL
PFR60 - 415 - 50
PFR80 - 415 - 50
PFR120 - 415 - 50
PFR140 - 415 - 50
PFR60 - 220 - 50
PFR80 - 220 - 50
PFR120 - 220 - 50
PFR140 - 220 - 50
PFR60 - 415 - 60
PFR80 - 415 - 60
PFR120 - 415 - 60
PFR140 - 415 - 60
PFR60 - 220 - 60
PFR80 - 220 - 60
PFR120 - 220 - 60
PFR140 - 220 - 60
DESCRIPTION
6 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
8 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
12 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
14 Steps, 50 Hz system, auxiliary voltage 380~415 V AC
6 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
8 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
12 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
14 Steps, 50 Hz system, auxiliary voltage 220~240 V AC
6 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
8 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
12 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
14 Steps, 60 Hz system, auxiliary voltage 380~415 V AC
6 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
8 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
12 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
14 Steps, 60 Hz system, auxiliary voltage 220~240 V AC
Pow
er Factor Regulator
PFR
140 / 120 / 80 / 60
Technical Data
RATINGS AUXILIARY POWER SUPPLY
Model PFR96 : 110 ~ 120 V AC / 220 ~ 240 V ACModel PFR96P : 380 ~ 415 V ACOperating Limits : -15% + 10%Consumption : 10 VA maxRated frequency : 50 Hz or 60 Hz
OUTPUT CONTACTS
Numbers of outputs : 6Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operationsMax current for the common terminals : 12 A continuous
CURRENT INPUT
Rated current ( In ) : 5 AOperating Limits : 0.15 A to 6.5 ARated frequency : 50 Hz or 60 Hz
CONTROL RANGE
Power factor setting : 0.8 Ind - 0.8 CapC/K setting : 0.03 - 1.20 / AutomaticSwitching sensitivity : 5 - 600 s/stepReconnection time for same step : 5 - 240 sSwitching Program : Automatic / Automatic
Rotate / 4-quadrant / Manual
: 0 / 1 / 2 / 3 / 4 / 5 / 6 / 8 / 12 / 16
( Automatic if C/K set to Auto )
PFR96PFR96P
Features
• Microprocessor based intelligent auto switching control
• Automatic C/K and rated step adjustment
• Automatic CT polarity correction
• Display of power factor & current
• Programmable sensitivity
• Last step can be used as alarm/fan output
• Under/over voltage alarm, under/over compensate alarm
• User-friendly setting
• Complies with IEC 61000-6-2 standard
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 90(d)Approximate weight : 0.6 kg
For PFR 96
• For single-phase system
For PFR 96P
• For 3-phase system
Pow
er Factor Regulator
PFR
96 / 96P
K1 K6K5
FUSE
Po
we
r F
act
or
Re
gu
lato
r
VOLTAGE380~415V AC
MAIN
L1L2L3N
8
7
6
5
4
3
2
1
CURRENT/ 5 A
6
5
4
3
2
1
16
15
14
13
12
11
10
9P2
P1
FUSE
LOAD
K1 K6K5
FUSE
FUSE
Po
we
r F
act
or
Re
gu
lato
rVOLTAGE220 V AC /110 V AC
MAIN
L1L2L3N
8
7
6
5
4
3
2
1
CURRENT/ 5 A
6
5
4
3
2
1
16
15
14
13
12
11
10
9P2
P1
LOAD
Typical Application Diagram
Ordering Information
Diagram 2 - For model PFR96PDiagram 1 - For model PFR96
Case Dimensions
96 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
70 mm90 mm
96m
m
Front
Side
PanelCutout
MODEL
PFR96 - 220 - 50
PFR96 - 220 - 60
PFR96 - 110 - 50
PFR96 - 110 - 60
PFR96P - 415 - 50
PFR96P - 415 - 60
DESCRIPTION
6 Steps, for 50 Hz system, auxiliary voltage 220~240 V AC
6 Steps, for 60 Hz system, auxiliary voltage 220~240 V AC
6 Steps, for 50 Hz system, auxiliary voltage 110~120 V AC
6 Steps, for 60 Hz system, auxiliary voltage 110~120 V AC
6 Steps, for 50 Hz system, auxiliary voltage 380~415 V AC
6 Steps, for 60 Hz system, auxiliary voltage 380~415 V ACP
ower Factor R
egulatorP
FR 96 / 96P
Typical Application Diagram
Pow
er Factor Regulator
PFR
LCD
PFRLCDFeatures
• 2” inch, 64 x 128 dot matrix LCD display with back lighting
• Three phase and single phase detection of reactive power
• 12 (or 8 for 8 step model) output with two additional
• Independent contact for signal alarm output and fan output
• Three phase compensation mode
• • Automatic detection of C/K and rated
step value
• No Voltage release
• • Alarm linked signal contact
• Programmable fan control
• ModBus-RTU communication
• Active, reactive, apparent power
• Temperature
• Phase voltage and phase current
• Frequency
• Up till 31st order Harmonics measurement in graphical and table format
• Power Factor and Displacement Power Factor (Cosφ)
Measurement Parameters
L1 L2 NL3
3435
3344
3243
4241
3938
3736
40
2120
2214
2313
1211
98
76
104
32
15
SIGFAN
12
45
67
39
1011
128
2430 Thermistor
T1
P+
N-RP
T2
31
GND
PFR
LC
D
FANSIG
AUX
NL
S2S2
S1S1
S2S1
L3L2
L1N
CT2
CT1
CT3
RS485 Modbus-RTU
FUSE
FUSE
P1P2
P1P2 P1
P2
K12 K2 K1
PFRLCD120P3-230-50
LOAD
L1 L2 NL3
3435
3344
3243
4241
3938
3736
40
2120
2214
2313
1211
98
76
104
32
15
SIGFAN
12
45
67
39
1011
128
2430 Thermistor
T1
P+
N-RP
T2
31
GND
PFR
LC
D
FANSIG
AUX
NL
Out
InL3
L2L1
NC
T1
RS485 Modbus-RTU
FUSE
FUSE
P1P2
K12 K2 K1
PFRLCD120P1-230-50
LOAD
PFRLCD Connection diagram for 3 Phase 12 Step model PFRLCD Connection diagram for 1 Phase 12 Step model
Ordering Information
Case Dimensions
Front View
Panel Cutout
144mm
Side View
122mm
102mm
144m
m
138mm
138mm
Pow
er Factor Regulator
Technical Data
CURRENT INPUT (EACH PHASE)
Nominal Current : 5 A rmsOperating Limits : 0.01-10 A rmsRated frequency : 50 Hz or 60 Hz
VOLTAGE INPUT
(EACH PHASE with respect to neutral)
Nominal Voltage : 230 VrmsOperating Limits : 0 - 277 V L-NConsumption : 0.05 VARated Frequency : 50 Hz or 60 HzCatagory : III
THERMISTOR INPUT
Thermistor Temperature range : 0 – 100 °C
AUXILIARY
Auxiliary Input Voltage Range : 85 - 265 VrmsConsumption : 10 VA maxRated Frequency : 50 Hz or 60 Hz
OUTPUT CONTACTS
Number of outputs : 14 (model dependent)Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
CONTROL RANGE
Target Power factor : 0.80 Inductive – 0.80 Capacitive
C/K setting : 0.03 – 1.20 / Automatic detect
Sensitivity : 5 - 300s / StepReconnection time : 5 – 240s Switching program : Automatic/ Manual/
Four-quadrant/ Rotational/ Linear
: 0/ 1/ 2/ 3/ 4/ 5/ 6/ 8/ 12/ 16/ Fixed
Detection mode : L1 / L2 / L3 / Max Load / Three Phase
Fan Setting : Fixed on / Output On / Temperature / None
Signal Contact programmable alarm / None
ALARM SETTING RANGE
%THDI : 20 - 300% / OFFOver Voltage : 253 – 264 V/ OFFUnder Voltage : 195 – 204 V/ OFFOver Current : 5.50 – 7.00 A/ OFFUnder Current : 0.01 – 0.15 A/ OFFUnder Compensate : On / OFFOver Compensate : On / OFF*CT Polarity Error : On / OFFStep Error : On / OFFTemperature : 36 – 70 °C / OFF
DISPLAY
%THDI & %THDV : 0 – 500%Harmonics Resolution : Up till 31st Harmonics Active power : 0– 3000 WReactive power : 0 – 3000 VARApparent power : 0 – 3000 VAVoltage : 0 – 300 VACCurrent : 0.00 – 10.0 A rmsTemperature : 0 – 100 °CFrequency : 45 – 65HzPower Factor : -1.00 – 1.00Displacement Power Factor : -1.00 – 1.00
ENVIRONMENT CONDITIONS
Temperature : -5°C to +55°CHumidity : 56 days at 93%RH and
40°C non-condensingPollution Degree : IIDielectric Withstand : IEC61010-1Altitude : 2000 m
ELECTROMAGNETIC COMPATIBILITY (EMC)
Part 6-2: Generic standards : IEC61000-6-2Immunity for industrial environmentsPart 6-4: Generic standards : IEC61000-6-4Emission standard for industrial environments
MECHANICAL Mounting : Panel mountingDimension (mm) : 144(w) x 144(h) x 122(d)Enclosure protection : IP54 at the panel IP20 at the bodyApproximate weight : 1.2 kg (for three phase model), 1 kg (for single phase model)
MODEL
PFRLCD120P3-230-50
PFRLCD80P3-230-50
PFRLCD120P1-230-50
PFRLCD80P1-230-50
PFRLCD120P3-230-60
PFRLCD80P3-230-60
PFRLCD120P1-230-60
PFRLCD80P1-230-60
DESCRIPTION
12 Step, 3 Phase, 230Vrms, 50Hz Model
8 Step, 3 Phase, 230Vrms, 50Hz Model
12 Step, 1 Phase, 230Vrms, 50Hz Model
8 Step, 1 Phase, 230Vrms, 50Hz Model
12 Step, 3 Phase, 230Vrms, 60Hz Model
8 Step, 3 Phase, 230Vrms, 60Hz Model
12 Step, 1 Phase, 230Vrms, 60Hz Model
8 Step, 1 Phase, 230Vrms, 60Hz Model
PFR
LCD
Tests And StandardsElectrostatic discharge IEC61000-4-2, Class III, air discharge 8 KVElectrostatic discharge IEC61000-4-2, Class III, contact discharge 6 KVElectrical fast transient IEC61000-4-4 4 KV, 5/50nsSurge immunity IEC61000-4-5 4 KV, L to EEnclosure protection when panel mounted Front: IP41 Enclosure: IP30
AN112AN120AN128
Annunciator
AN
112 / 120 / 128
Features
• 12, 20 or 28 windows. Replaceable super-bright LED modules, with choice of amber or red illumination
• 11 Alarm Sequences as per ISA-18.1 standard
• programmable, either from front panel built-in pushbutton or using PC
• Option of either RS232 or RS485 MODBUS-RTU communication. Comes with user-friendly
• Repeat relay for each window as well as
relays for connection to external equipment to form alarm management system
• Sleep or unattended mode feature is available, for stations not permanently manned
• Auto-silence and auto-acknowledge features, with delay settable from 1 – 255 s
• Other amount of windows available upon request.
The AN112/120 series Alarm Annunciator provides ideal solution for all your alarm system management and requirement. It comes with either 12, 20 or 28 windows, and due to the use of microprocessor-based design, the alarm annunciator is highly
and industries.
Programmable Alarm Annunciator
Technical Data
WINDOWWindow Dimension : 50 x 30 mm.Type: White translucent lens.Colours: Red, Amber. Coloured
module.Windows Flash Fast: 1.4 Hz
Slow: 0.45 Hz
Intermittent:
ALARM SEQUENCESM, A, R, R-12, F1A, F1M, F2A, F2M, F3A, F3M, Follower
AUXILIARY POWER INPUTFuse protected.AN1xx-30 : 24-36 V DC or 18-27 V AC.AN1xx-110 : 88-132 V DC or 64-95 V AC.Power consumption : AN112: 6 W, AN120: 8 W,
AN128: 10W
ALARM CONTACT INPUTSOpto-isolated inputsAN1xx-30 : 24-36 V DCAN1xx-110 : 88-132 V DCInput current : 3 mA typical
OUTPUT CONTACTSRepeat relays : Potential free for each
alarm point. 5 A at 250 V AC, 3 A at 30 V
DC. Resistive load.AUX1-AUX3, RBACK, SSP : 5 A at 250 V AC, 5 A at 30 V
DC. Resistive load.
TERMINALSWire size : 28-14 AWG. ( 0.08mm2 to 2.5mm2 ) Removable screw type terminal block
COMMUNICATION Hardware interface : AN1xx - xx - x - A: RS232 AN1xx - xx - x - B : Isolated
RS485Protocol : Modbus - RTUBaud rate : 300 to 57600
ENVIRONMENT CONDITIONSOperation temperature: -20 to 60˚CStorage temperature : -20 to 80˚CHumidity : 0 - 95% RH,
non condensing
MECHANICAL Mounting : Panel MountingApproximate weight : AN 112 : 2.4 kg AN 120 : 3.1 kg AN 128 : 3.5 kg
Annunciator
Case Dimensions
Ordering Information
Order code:A: RS 232 communicationB: RS 485 communication
0: without repeat relays1: with repeat relays
Power Supply: 30, 110 V DCNumber of Windows: 12, 20, 28
For example: 12 windows, 30 V DC, with repeat relays, RS232 communication: AN112-30-1-A
AN1 - - -
Typical Connection Diagram
4 3 2 1C12
- +-+
- +
4 3 2 1C11
- +
4 3 2 1C10
- +
4 3 2 1
1 21Sleep
2 3
1 2
Power
PowerGround
3 5 6 7
D-D+
4
C9
RS485
RS232
- +
4 3 2 1C8
- +
4 3 2 1C7
- +
4 3 2 1C6
- +
4 3 2 1C5
- +
4 3 2 1C4
- +
-+
1 2 3 4 2 3 41
RBCK SSP AUX3
Relay output
AUX2 AUX1
6 7 85 109
Button
MuteAck
ResetTest
1RstDis
1 2 3 4C3
-+
1 2 3 4C2
-+
1 2 3 4C1
AN120 Front
237 mm
217
mm
AN112 Front
237 mm
157
mm
Bottom
206 mm
1.5 mm
132
mm
132 mm
126 mm
AN112 Side
132 mm
186 mm
AN120 Side
AN128 Front
237 mm
277
mm
132 mm
246 mm
AN128 Side
AN
112 / 120 / 128
Features
• Alarm monitoring
• Outputs for lamp and horn
• Indicators for output contacts
Product Description
Alarm relay provides LED indication and output
contact signalling when there is alarm signal
received. The alarm relay consist of alarm input,
alarm accept, alarm reset, lamp test controlled
input and 2 relay contacts. Red LED indication
2 (LED) turned on when alarm signal is received.
AL24
Annunciator
AL 24
Technical Data
INPUT
Auxiliary input : 24 V DC ± 5%Max power consumption : 2 W
INPUT CONNECTION
Alarm input : Pin 7Aalrm accept : Pin 4Lamp test : Pin 8Reset : Pin 5Common : Pin 6
INPUT TYPE
Dry contact
OUTPUT CONTACTS
Rated voltage : 250 V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
INDICATORS
Auxiliary supply : Green indicatorRelay 1 (Lamp) : Red indicatorRelay 2 (Horn) : Red indicator
ENVIRONMENTAL CONDITIONS
Temperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and
40˚C non-condensing
MECHANICAL
Mounting : Circular 11-pin plug-in socket
Dimension (mm) : 35(w) x 80(h) x 72.5(d)Approximate weight : 0.2 kg
Annunciator
Case Dimensions
80 mm
AUXILIARY
Alarm Relay
AL 24
RELAY 1RELAY 2
72.5 mm
35 mm
Ordering Information
AL 24 Auxiliary voltage 24 V DC
MODEL DESCRIPTION
Auxiliary supply (pin +2, -10)Alarm (pin 7, 6)Alarm accept (pin 4, 6)Reset (pin 5, 6)Relay 1 (Lamp)Relay 2 (Horn)Lamp test (pin 8, 6)
Operation Diagram
Connection Diagram
5 6 78
RY1
RESE
T
ALA
RMAC
CEPT
LAM
PTE
ST
NO
+
NO
COM
Power Supply ( DC only )
COM
RY29
10111
2
3
4
-
ALA
RM
AL 24
Technical Data
CT RATINGSRated current : 2-10ARated frequency : 50 Hz or 60 HzBurden : <0.3 VA at rated currentThermal withstand : Continuous : 2x max rated 45s : 6x max rated 1s : 10x max rated
BINARY INPUTRated input voltage : 12V (Supplied internally)
AUXILIARY SUPPLYModel MPR 500-240AD : 85 ~ 265 V AC 110 ~ 370 V DCSupply frequency : 50 or 60 HzMaximum power consumption : 3 VA typical
OUTPUT CONTACTSRated voltage : 250V ACContact rating : 5 AExpected electrical life : 100,000 operations at
rated currentExpected mechanical life : 5 x 106 operations
SETTING RANGESThermal Overloadtime constant, t6X : 1 – 40s. Step 0.1s for 1-10s, step 1s for 10-40s. Short circuit, I>> : B. Step 1 x IBShort circuit delay time, t>> : 0 – 25s. Step 0.1s for 1-10s, step 1s for 10-25s. Undercurrent, I<< : B. Step 1%Undercurrent delay time, t<< : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.Unbalance, : Step 1%Unbalance delay time, t : 0 – 25s. Step 0.1s for 1-10s, Step 1s for 10-25s.Earth fault, I0 : B. Step 1%Earth fault delay time, t0 : 0 – 25s. Step 0.1s for 1-10s, step 1s for 10-25s.Phass loss : < 120msPhase sequence : < 120ms
Prolonged starting/stalled rotor, IS : B. Step 0.1 x IBProlonged starting time delay, tStart : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.Stalled rotor delay time, tStall : 0 – 60s. Step 0.1s for 1-10s, step 1s for 10-60s.
INDICATORSRun : Green indicatorTrip/Pickup : 7-segment display and red indicatorThermal : Yellow indicator
ENVIRONMENTAL CONDITIONSTemperature : -5˚C to +55˚CHumidity : 56 days at 93% RH and 40˚C
non-condensing
MECHANICALMounting : Panel mountingDimension (mm) : 96(w) x 96(h) x 110(d)Approximate weight : 0.8 kg
Motor P
rotection Relay
MP
R 500
MPR500Features
• Microprocessor based numerical relay
• Thermal overload
• Overcurrent
• Undercurrent
• Unbalance
• Phase loss
• Phase sequence
• Earth fault
• Prolonged starting/stall rotor
• 2 voltage-free output contacts
• ANSI Code : 37, 46, 47, 49, 50P, 50G
Motor P
rotection Relay
(a) With 0% thermal capacity (cold start)
time
t6x
I / I B
10 sec
1 sec
2 sec3 sec
5 sec
21 3 4 5 6
20 sec30 sec40 sec1 min
2 min3 min
5 min
10 min
20 min30 min
1 hour
2 hour
2s
5s
10s
20s30s40s
1s1.05
Typical Application Diagrams
t6x
2s
5s
10s
20s30s40s
1s
(b) With prior 50% thermal capacity
21 3 4 5 6
1.05
I / I B
time
10 sec
1 sec
2 sec3 sec
5 sec
20 sec30 sec40 sec1 min
2 min3 min
5 min
10 min
20 min30 min
1 hour
2 hour
Thermal Tripping Curve Case Dimensions
Aux
6
2
3
4
5
L
R1
R2
N
9
10
11
12
13
14
715
816
1
MPR 500
L
M
K1
N
K1H1
S2
S1
K1
Block R1/Reset/Trip
Start
Stop
NO
NC
COM
COM
NC
NOBinaryinput
F1
F2
Single-Phase Motor)
Ordering Information
MPR500-240AD For 50 / 60 Hz system, auxiliary voltage 85 ~ 265 V AC or 110 ~ 370 V DCMODEL DESCRIPTION
96 mm
110 mm100 mm
91.0 ± 0.5 mm
91.0
± 0
.5 m
m
Front
Side
Panel Cutout
96 m
m
MP
R 500
Aux
6
2
3
4
5
L
R1
R2
N
9
10
11
12
13
14
715
816
1
MPR 500
L1L2L3
M
K1
N
K1H1
S2
S1
K1
Block R1/Reset/Trip
Start
Stop
NO
NC
COM
COM
NC
NOBinaryinput
F1 F2 F3
F4
Motor with higher full load current using external CT
top related