Maryland Transportation Authority Police Training Facility
Schematic Design PresentationDecember 13, 2007
Leah Clark
Location: Hawkins Point, Baltimore, Maryland
Size: • 42,100 square feet • 2 stories above grade
Project Team: • Owner: Maryland Transportation Authority • Mechanical and Electrical: Johnson, Mirmiran, & Thompson • Architectural: Rubeling & Associates • Civil and Structural: Carroll Engineering, Inc. • Construction Manager: To be determined by competitive bid among prequalified biddersContractor: To be determined (by bid among prequalified contractors)
Overview
First Floor
Front Façade
Physical Training Gym
Classroom ‘A’
Firing Range Area
Second Floor
SectionsClassroom ‘A’
Firing Range Area
Front Façade
Physical Training Gymnasium
SectionsClassroom ‘A’
Firing Range Area
Front Façade
Physical Training Gymnasium
Design Criteria Light Distribution of Task Plane
Uniformity on task plane
Peripheral Emphasis
Control and FlexibilityVariety of tasksMultiple switching options
Illuminance Levels (to perform task)
Classroom ‘A’
Classroom ‘A’
Zone 4
Zone 1
Zone 2
Zone 3
Zone 5
Projection Screen
TV
WhiteboardWhiteboardLighting
Under-cabinetLightingSuspended
Direct-IndirectLighting
Classroom ‘A’
Range AreaDesign Criteria Control and Flexibility
Pseudo-realistic training environments Multiple lighting systems Control system with preset lighting scenes
Illuminance LevelsVertical face of the targets
Interior Conditions – 50 fcExterior Conditions – 10 fc
Horizontal illuminance in the shooting lines Interior Conditions – 20 fcExterior Conditions – 1 fc
Direct Glare
Lower cutoff angles for fixtures
Range AreaDimmable Recessed Compact FluorescentLighting
Red LED Lighting to signal when firing lane is in use
High Pressure Sodium Fixtures to simulate exterior night lighting scene
Range AreaDimmable Recessed Compact FluorescentLighting
Red LED Lighting to signal when firing lane is in use
Linear Fluorescent Lighting to simulate normal interior conditions
Range Area
Floor Recessed Fixtures illuminate vertical face of targets
Shooting Targets
Physical Training GymnasiumDesign Criteria
Control and Flexibility
Allow fixtures to be Multiple lighting systems Control system
Illuminance Levels
Highlight Exposed StructureUplight ceiling joists
Physical Training Gymnasium
Physical Training Gymnasium
Design Criteria Sense of Direction
Higher light levels at entrance Points of interest Precast logos
Light Pollution / Trespass Modeling of Faces and Objects Safety and security
Security cameras
Light Distribution on SurfacesHierarchy of light
Front Facade
Front Facade
Building Identification
Standing Seam Metal Awning
MdTA Police Logo
Main Entrance
MdTA Logo
Front Facade