m international limited - diytrade.comdoc.diytrade.com/docdvr/229183/23522064/1318177421.pdf ·...
Post on 05-Jun-2018
224 Views
Preview:
TRANSCRIPT
1
METALS INTERNATIONAL LIMITED
ANBAI TRADING (SHANGHAI) Co.,LTD.
L, 5/F, Liaoshen International Bldg,1068 Wuzhong Rd., Shanghai 201103 China
Tel: +86-21-6090-0836/60900837/6563 Fax: +86-21-6090-0838
Hhttp://www.klsteel.comUH Email: copprtube@klsteel.com HTUsklsteel@yahoo.com.cn
2
Company Profile
Metals International Limited is a reliable exporter and supplier of a wide
range of copper and copper alloy tubes, rods, bars, strips and profiles. Our
wide range of products includes Copper Tubes for Air Conditioning and
Refrigeration, Copper Tubes for Other Applications and Copper Alloys
Tubes. Adding on, we also offer Copper Bus Bar, Profiles and Rods, Copper
Coils and Strip and Plates for Earthing System as well as Copper Fittings.
All of our products are in full compliance with ASTM B68, ASTM B75,ASTM
B88, ASTM B111/ 111M ,ASME SB111/M,ASTM B280, ASTM A360, ASTM
B306, ASTM B743, ASTM A836,ASTM 837,ASME B16.22, BS 359,BS 864, BS
2871,BS EN1057, BS EN12737, BS EN12449, AS 1432, AS/NZ 1571, AS
1572,NZS 3501, GB/T 1527-2006, GB/T 8890-1998, JIS H3300:1997 etc. and
widely applied to various industries such as ACR, boiler construction, water,
gas and oil field.
Company is committed to quality products and also treasures its employees
who make it happen. Its vast organizational strength comprises of dedicated
and skilled teammates whose core competence lies in making a good
products, a better one.
With consistent strategic policy and continuous growth, Metals International
Limited has emerged out as a prominent player in the league of world-class
corporation of metals in the Global market. The organization has been
expanding, integrating and growing at the speed of light the fulfill the
ambition of its Global excellence. The establishment of Shanghai office had
been a major milestone in the path of progress of the Group.
Our goal is to provide quality products to our customers at competitive
prices with best service that will ensure long-term relationships with our
customers.
3
Specification
Type Usage Size Alloy Number Standard
O.D. (mm) W.T. (mm) ASTM EN JIS BS AS Welded
Copper
Tube
ACR 6-105 0.4-8 C12200/
C1220/CU-DHP ASTM B280 EN12735 JIS3300 BS1057 AS/NZS1571 ASTM B640
Water Tube 9-300 0.4-60 C12200 /CU-DHP/
CW024A/K/L/M
ASTM B88
/ANSI/NSF61/ASTM B698 EN1057 JIS3300 BS1057 NZS3501 ASTM B466
Copper Drainage
Tube(DWV) 9-300 0.4-60 C12200 ASTM B306 EN1057 JIS C1220 BS1057 AS1432 ASTM B467
ACR, GAS Pipe 9-76 0.4-8 C12000/C12200/C1020
0 ASTM B68 /ASTM B837 EN1057 JIS3300 BS1057 NZS3501
Condenser &
Heat Exchanger 6-108 0.4-8 C12200 ASTM B75 /ASTM 359 EN 12451 JIS3300 BS1057 AS2378
ASTM 395
/ASTM B543
Electrical Tube 9-76 0.4-8 EN13600 BS13600 ASTM B447
Medical &
Vacuum 9-300 0.4-60 ASTM B819 EN13348
BS 1057/
BS2871
Copper
Fittings
ACR/Pipe/Gaslin
e Pipe fittings 6-108 0.4-8 C12200 ASME B16.22 EN1254 JISH3401 BS864-2
Brass
Tube
Admiralty Brass
Tube 4-100 0.4-12
C44300/ CuZn28Sn1/
HSn70-1 ASTM111 EN 12451 JIS3300 BS1057 AS1569
4
Common Brass
Tube 4-100 0.4-12 C27200/C27400 ASTM B135 EN 12451 JIS3300 BS1057
Aluminum Brass
Tube 4-100 0.4-12 C68700/C6870/ CZ110 ASTM B359 EN 12451 JIS3300 BS1057 AS1569
Copper-
Nickel
Tube
90/10 Cu-Ni Tube 4-100 0.4-12 C70600/C7060/ CN102 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1569
70/30 Cu-Ni Tube 4-100 0.4-12 C71500/C7150/
CN107/C26000 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1572
4-100 0.4-12 C71640 ASTM B111/ASTM B3466 EN 12451 JIS3300 BS1057 AS1569
Insulate
d Coils
6.35-19.05
/24-41
0.8-1.22/8-
10 ASTM B743 AS1571
5
Manufacturing Process CASTING
Copper cathode is heated to melting point then cast into copper billets in a
modern remelt and casting facility. Precise control is maintained over metal
composition and billet quality is assured by skilled casthouse and on-site
laboratory personnel.
EXTRUSION
A 3,500 tonne hydraulic extrusion press converts the solid copper billets into
long tubular "shells" by forcing the preheated billet through a die and over a
piercing mandrel. Crane Copper Tube production and engineering excellence
has resulted in innovative extrusion techniques which produce shells of
superior dimensional and compositional uniformity enabling subsequent cold
drawing to finished dimensions with precise tolerances.
6
DRAWING
Cold drawing of the shell is carried out on an extensive array of specialised
equipment. Specially designed cold drawing machines called "bullblocks"
economically produce large quantities of thin-walled tube whilst larger diameter
and thick-walled tubes are rapidly produced on multi-die "drawbenches". Close
supervision by process operators and staff ensures tube of the desired
dimensional and mechanical properties.
FINISHING
The cold-drawn tubing is conveyed to "finishing lines" which manipulate and
cut the tube to produce a product of the required form and length. All tube is
inspected for defects using on-line eddy current analysis which ensures that
only flawless tube is packed and shipped from the mill.
7
ANNEALING
The temper of some tube is modified using annealing ovens which maintain
strict control over temperature and furnace atmosphere resulting in product
without discolouration and with those mechanical properties desired by the
customer.
LAGGING
Copper tube is fed through a specially designed cross-head plastic extruder
which applies a plastic coating in plain or castellated form. This provides the
customer with a cost effective prelagged copper tube.
8
BS EN 1057
BS EN 1057 has replaced the British Standard BS 2871 Part 1 and other conflicting standards previously used. This
standardization with EN 1057 has provided a common standard for many markets. However, as there are no
dimensional changes, all EN 1057 tube is totally compatible with current BS tube and fittings.
EN 1057 - TYPE Y (PREVIOUSLY BS 2871 TABLE Y)
Size Nom. Dia.
(Outside)
Nom. Wall
Thickness
Max. Working Pressures*
Half Hard Hard Annealed
mm mm mm bar+ bar+ bar+
6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
0.8
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.5
1.5
2.0
2.0
2.0
2.5
188
136
106
87
87
72
69
55
54
45
47
37
33
29
223
161
126
104
104
85
84
65
65
54
56
45
39
34
144
105
82
67
67
55
53
42
41
34
36
28
25
22
*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Underground works and heavy duty requirements including hot and cold water
supply, gas reticulation, sanitary plumbing, heating and general engineering.
ADDED
TOUGHNESS &
DURABILITY
9
EN 1057 - TYPE X (PREVIOUSLY BS 2871 TABLE X)
Size Nom. Dia.
(Outside)
Nom. Wall
Thickness
Max. Working Pressures*
Half Hard Hard Annealed
mm mm mm bar+ bar+ bar+
6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
133
159
6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
133
159
0.6
0.6
0.6
0.6
0.7
0.8
0.9
0.9
1.2
1.2
1.2
1.2
1.5
1.5
1.5
2.0
133
97
77
63
58
56
51
40
42
35
27
20
24
17
14
15
161
118
93
76
71
67
62
48
51
43
33
27
29
20
17
18
102
75
59
48
45
43
39
31
33
27
21
17
18
13
10
12
*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Above groundservices including drinking water supply, hot and cold water
systems, sanitation, central heating and other general purpose applications.
ECONOMICAL
AND
STRONG
10
EN 1057 - TYPE Z (PREVIOUSLY BS 2871 TABLE X)
Size Nom. Dia.
(Outside)
Nom. Wall
Thickness Max. Working Pressures*
mm mm mm bar+
6
8
10
12
15
18
22
28
35
42
54
66.7
76.1
108
133
159
6
8
10
12
15
18
22
28
35
42
54
66.7
76.3
108
133
159.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.8
0.9
1.0
1.2
1.2
1.5
1.5
113
98
78
64
50
50
41
32
30
28
25
20
19
17
16
15
*Based on material in hard drawn condition at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Above groundservices including drinking water supply, hot and cold water
systems, sanitation, central heating and other general purpose applications.
LOW COST
UTILITY
RANGE
MECHANICAL PROPERTIES OF TUBE TO EN 1057
Temper Nom. Dia.
(Outside) MPa*
Minimum
Elongation Hardness**
R220 Annealed
R250 Half Hard
R250 Half Hard
R290 Hard
6 to 54mm
6 to 66.7mm
6 to 159mm
6 to 267mm
220
250
250
290
40%
30% #
20% #
3%
40 to 70
75 to 100
75 to 100
100 min
# Note: Elongations for half hard tubes depend on the ratio of outside diameter to wall thickness.
* MPa: Minimum tensile strength ** Hardness HV/5 indicative
11
ASTM B88 : 99 (Copper Water and Gas Tube)
This specification covers hard drawn temper, seamless copper tubes which are suitable for use in general
plumbing applications, such as underground water service, potable water distribution, gas distribution and fire
sprinkler installations.
To assist with selection this standard is separated into three Types - K, L and M. Each type is differentiated by a
range of wall thicknesses, with Type K having thicker walls than Type L, and Type L being thicker than Type M, for
any given diameter.
TYPE K
Nom.
Size (")
Dimensions (")
Calculated Values (Based on ASME B31)
*Rated internal working pressures (psi)
Nom. Weight
(lbs per ft)
Actual
Wall
Thickness
Surface Temperature
Outside Diameter
Up to 150°F 300°F
Annealed Hard Drawn Annealed Hard Drawn
1/4
3/8
1/2
5/8
3/4
1
1¼
1½
2
2½
3
3½
4
5
6
8
.375
.500
.625
.750
.875
1.125
1.375
1.625
2.125
2.625
3.125
3.625
4.125
5.125
6.125
8.125
3/8
1/2
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
.035
.049
.049
.049
.065
.065
.065
.072
.083
.095
.109
.120
.134
.160
.192
.271
913
979
769
633
735
563
456
424
372
341
330
313
308
295
296
315
2029
2135
1683
1389
1609
1236
1003
933
820
751
579
549
540
517
520
554
842
902
709
583
662
520
420
391
343
314
304
288
283
272
272
290
1974
2077
1638
1351
1566
1203
976
908
798
731
560
531
522
500
502
535
0.145
0.269
0.344
0.419
0.642
0.839
1.037
1.362
2.065
2.928
4.005
5.124
6.516
9.678
13.878
25.930
12
TYPE L
Nom.
Size (")
Dimensions (")
Calculated Values (Based on ASME B31)
*Rated internal working pressures (psi)
Nom. Weight
(lbs per ft)
Actual
Wall
Thickness
Surface Temperature
Outside Diameter
Up to 150°F 300°F
Annealed Hard Drawn Annealed Hard Drawn
1/4
3/8
1/2
5/8
3/4
1
1¼
1½
2
2½
3
3½
4
5
6
8
.375
.500
.625
.750
.875
1.125
1.375
1.625
2.125
2.625
3.125
3.625
4.125
5.125
6.125
8.125
3/8
1/2
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
.030
.035
.040
.042
.045
.050
.055
.060
.070
.080
.090
.100
.110
.125
.140
.200
775
662
614
536
495
420
373
347
309
286
269
258
249
229
213
230
1722
1471
1362
1192
1099
933
828
771
686
633
476
456
440
404
376
406
714
610
565
494
456
387
344
319
285
263
248
238
229
211
197
211
1676
1431
1325
1160
1069
908
806
750
667
616
449
441
425
391
364
393
0.126
0.198
0.286
0.362
0.448
0.655
0.885
1.144
1.753
2.480
3.328
4.295
5.381
7.615
10.208
19.310
13
TYPE M
Nom.
Size (")
Dimensions (")
Calculated Values (Based on ASME B31)
*Rated internal working pressures (psi)
Nom. Weight
(lbs per ft)
Actual
Wall
Thickness
Surface Temperature
Outside Diameter
Up to 150°F 300°F
Annealed Hard Drawn Annealed Hard Drawn
3/8
1/2
3/4
1
1¼
1½
2
2½
3
3½
4
5
6
8
.500
.625
.875
1.125
1.375
1.625
2.125
2.625
3.125
3.625
4.125
5.125
6.125
8.125
1/2
5/8
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
5 1/8
6 1/8
8 1/8
.025
.028
.032
.035
.042
.049
.058
.065
.072
.083
.095
.109
.122
.170
485
420
346
286
287
281
254
233
215
214
313
198
185
195
1077
932
769
636
638
625
563
517
380
378
377
349
328
344
446
387
319
264
265
259
234
215
198
197
197
182
171
179
1048
907
748
619
621
608
548
503
367
366
365
337
317
333
0.144
0.204
0.328
0.465
0.682
0.940
1.460
2.027
2.678
3.582
4.664
6.661
8.922
16.475
* Annealed S = 5,100psi, Hard Drawn S = 11,300psi, for sizes ¼" to 2½" Nominal. S = 8,700psi for sizes over 2½" Nominal, as these
sizes are not normally available in the annealed form and are not therefore covered by ASME.
The figures provided are for guidance only, based on the indicated temperatures.
14
ASTM B280 : 99 (Seamless Copper Tube for Airconditioning and Refrigeration Field Service)
These tubes are supplied in both hard drawn straight lengths and annealed coils, after meticulous cleaning,
dehydrating and capping to ensure that the internal cleanliness standards are fully met. The intended use is in
the installation, repair, or alteration of airconditioning and refrigeration units.
STRAIGHT LENGTHS
Standard
Size, in.
Outside Dia.
in. (mm)
Wall Thickness
in. (mm)
Weight, lb/ft
(kg/m)
Nom. Weight,
kgs 5.8 metres
* Safe Working
internal pressures
PSI (KPa) 150°F
3/8
1/2
5/8
3/4
7/8
1 1/8
1 3/8
1 5/8
2 1/8
2 5/8
3 1/8
3 5/8
4 1/8
0.375 (9.52)
0.500 (12.7)
0.625 (15.9)
0.750 (19.1)
0.875 (22.2)
1.125 (28.6)
1.375 (34.9)
1.625 (41.3)
2.125 (54.0)
2.625 (66.7)
3.125 (79.4)
3.625 (92.1)
4.125 (104.8)
0.030 (0.76)
0.035 (0.89)
0.040 (1.02)
0.042 (1.07)
0.045 (1.14)
0.050 (1.27)
0.055 (1.40)
0.060 (1.52)
0.070 (1.78)
0.080 (2.03)
0.090 (2.29)
0.100 (2.54)
0.110 (2.79)
0.126 (0.187)
0.198 (0.295)
0.285 (0.424)
0.362 (0.539)
0.455 (0.677)
0.655 (0.975)
0.884 (1.317)
1.14 (1.703)
1.75 (2.609)
2.48 (3.692)
3.33 (4.954)
4.29 (6.393)
5.38 (8.010)
1.09
1.71
2.46
3.13
3.92
5.65
7.65
9.85
15.13
21.42
28.73
37.08
46.45
810 (5585)
675 (4654)
625 (4310)
545 (3758)
495 (3415)
440 (3035)
385 (2655)
355 (2450)
315 (2170)
295 (2035)
275 (1895)
270 (1860)
255 (1760)
ANNEALED COIL
Standard
Size, in.
Outside Dia.
in. (mm)
Wall Thickness
in. (mm)
Weight, lb/ft
(kg/m)
Nom. Weight,
kgs 15 metres
* Safe Working
internal pressures
PSI (KPa) 150°F
3/16
1/4
5/16
3/8
1/2
5/8
3/4
3/4
7/8
1 1/8
1 3/8
0.187 (4.76)
0.250 (6.35)
0.312 (7.92)
0.375 (9.52)
0.500 (12.7)
0.625 (15.9)
0.750 (19.1)
0.750 (19.1)
0.875 (22.2)
1.125 (28.6)
1.375 (34.9)
0.030 (0.76)
0.030 (0.76)
0.032 (0.81)
0.032 (0.81)
0.032 (0.81)
0.035 (0.89)
0.035 (0.89)
0.042 (1.07)
0.045 (1.14)
0.050 (1.27)
0.055 (1.40)
0.0575 (0.086)
0.0804 (0.120)
0.109 (0.162)
0.134 (0.199)
0.182 (0.271)
0.251 (0.373)
0.305 (0.454)
0.362 (0.539)
0.455 (0.677)
0.665 (0.975)
0.884 (1.317)
1.28
1.80
2.43
2.98
4.07
5.62
6.81
8.09
10.16
14.62
19.75
1690 (11650)
1230 (8480)
1040 (7170)
860 (5930)
630 (4344)
540 (3723)
440 (3034)
535 (3690)
500 (3450)
430 (2965)
390 (2690)
* Computed allowable stress for annealed copper tubes at the indicated temperature as determined from ASME B31.
15
ASTM B306 : Copper Drainage Tube (DWV)
This specification covers seamless copper drainage tube, which is intended for use with soldered fittings for
sanitary drainage, such as soil, waste and vent piping.
TYPE DWV
Nom.
Size (")
Dimensions (")
Calculated Values (Based on ASME B31)
*Rated internal working pressures (psi)
Nom. Weight
(lbs per ft)
Actual
Wall
Thickness
Surface Temperature
Outside Diameter
Up to 150°F 300°F
Annealed Hard Drawn Annealed Hard Drawn
1 1/4
1 1/2
2
3
4
5
6
8
1.375
1.625
2.125
3.125
4.125
5.125
6.125
8.125
1 3/8
1 5/8
2 1/8
3 1/8
4 1/8
5 1/8
6 1/8
8 1/8
.040
.042
.042
.045
.058
.072
.083
.109
280
249
185
135
128
128
126
124
621
552
410
239
225
227
223
219
258
230
170
124
117
118
116
114
604
537
399
231
218
220
216
209
0.649
0.810
1.066
1.689
2.874
4.432
6.110
10.645
* Annealed 150°F S = 5,100psi, sizes 1¼" to 8"
300°F S = 4,700psi, sizes 1¼" to 8"
Hard Drawn 150°F S = 11,300psi, sizes 1¼" to 2", S = 9,00psi sizes 3" to 8"
300°F S = 11,000psi, sizes 1¼" to 2", S = 8,70psi sizes 3" to 8"
The figures provided are for guidance only, based on the indicated temperatures.
16
AS 1432 : 2000 (Copper tubing for plumbing, gasfitting and drainage applications).
This standard provides for round seamless copper tubes intended for use in pressure and non-pressure plumbing,
gasfitting and drainage applications in hard drawn, bending quality, annealed, and plastic lagged coils and straight
lengths. Inert plastic lagging is available for this product coloured in green for potable drinking water and lilac for
recycled water applications.
TYPE A
NOMINAL
SIZE
NOM. DIA.
(OUTSIDE)
NOM. WALL
THICKNESS
PREVIOUS
SIZE
DN 6 *
DN 8 *
DN 10 *
DN 15 *
DN 18 *
DN 20 *
DN 25 *
DN 32 *
DN 40 *
DN 50
DN 65
DN 80
DN 90
DN 100
DN 125
DN 150
DN 200
6.4
7.9
9.5
12.7
15.9
19.1
25.4
31.8
38.1
50.8
63.5
76.2
88.9
101.6
127.0
152.4
203.2
0.9
0.9
1.0
1.0
1.2
1.4
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.6
2.6
1/4" x 20G
5/16" x 20G
3/8" x 19G
1/2" x 19G
5/8" x 18G
3/4" x 17G
1" x 16G
1¼" x 16G
1½" x 16G
2" x 16G
2½" x 16G
3" x 14G
3½" x 14G
4" x 14G
5" x 14G
6" x 12G
8" x 12G
TYPE B
NOMINAL
SIZE
NOM. DIA.
(OUTSIDE)
NOM. WALL
THICKNESS
PREVIOUS
SIZE
DN 6 *
DN 8 *
DN 10 *
DN 15 *
DN 18 *
DN 20 *
DN 25 *
DN 32 *
DN 40 *
6.4
7.9
9.5
12.7
15.9
19.1
25.4
31.8
38.1
0.7
0.7
0.9
0.9
1.0
1.0
1.2
1.2
1.2
1/4" x 22G
5/16" x 22G
3/8" x 20G
1/2" x 20G
5/8" x 19G
3/4" x 19G
1" x 18G
1¼" x 18G
1½" x 18G
17
DN 50
DN 65
DN 80
DN 90
DN 100
DN 125
DN 150
DN 200
50.8
63.5
76.2
88.9
101.6
127.0
152.4
203.2
1.2
1.2
1.6
1.6
1.6
1.6
2.0
2.0
2" x 18G
2½" x 18G
3" x 16G
3½" x 16G
4" x 16G
5" x 16G
6" x 14G
8" x 14G
TYPE C
NOMINAL
SIZE
NOM. DIA.
(OUTSIDE)
NOM. WALL
THICKNESS
PREVIOUS
SIZE
DN 10 *
DN 15 *
DN 18 *
DN 20 *
DN 25 *
9.5
12.7
15.9
119.1
125.4
0.7
0.7
0.9
0.9
0.9
3/8" x 22G
1/2" x 22G
5/8" x 20G
3/4" x 20G
1" x 20G
TYPE D
NOMINAL
SIZE
NOM. DIA.
(OUTSIDE)
NOM. WALL
THICKNESS
PREVIOUS
SIZE
DN 32
DN 40
DN 50
DN 65
DN 80
DN 90
DN 100
DN 125
DN 150
31.8
38.1
50.8
63.5
76.2
88.9
101.6
127.0
152.4
0.9
0.9
0.9
0.9
1.2
1.2
1.2
1.4
1.6
1¼" x 20G
1½" x 20G
2" x 20G
2½" x 20G
3" x 18G
3½" x 18G
4" x 18G
5" x 17G
6" x 16G
DN = DIMENSIONLESS NUMBER
Standard Lengths
Straights up to and including: DN 125 outside diameter - 6 metres
DN 150 and over - Random 4 to 6 metres
* Available as annealed coil: DN 8 and below - 30 metre lengths
DN 10 and above - 18 metre lengths
18
AS 1571 : 1995 (Copper - Seamless tubes for airconditioning and refrigeration).
These tubes are supplied in both hard drawn straight lengths and annealed coils, after meticulous cleaning,
dehydrating and capping, to ensure that the internal cleanliness standards are fully met. The intended use for this
product is in airconditioning and refrigeration applications.
STRAIGHT LENGTHS
Size
(mm)
Inches
& SWG
Nominal
kg/m
* Safe Working Pressure KPa
SD = 33.9
50-75°C
SD = 32.7
100-125°C
SD = 28.0
150-175°C
SD = 21.9
175-200°C
6.4 x 0.91
9.5 x 0.91
12.7 x 1.02
12.7 x 0.91
15.9 x 0.91
19.1 x 1.02
19.1 x 0.91
22.2 x 1.22
22.2 x 0.91
25.4 x 1.22
25.4 x 0.91
28.6 x 1.22
28.6 x 0.91
31.8 x 1.22
31.8 x 0.91
34.9 x 1.22
34.9 x 0.91
38.1 x 1.22
38.1 x 0.91
41.3 x 1.22
41.3 x 0.91
44.5 x 1.22
44.5 x 0.91
50.8 x 1.63
50.8 x 1.22
50.8 x 0.91
54.0 x 1.63
54.0 x 1.22
54.0 x 0.91
1/4" x 20
3/8" x 20
1/2" x 19
1/2" x 20
5/8" x 20
3/4" x 19
3/4" x 20
7/8" x 18
7/8" x 20
1" x 18
1" x 20
1 1/8" x 18
1 1/8" x 20
1 1/4" x 18
1 1/4" x 20
1 3/8" x 18
1 3/8" x 20
1 1/2" x 18
1 1/2" x 20
1 5/8" x 18
1 5/8" x 20
1 3/4" x 18
1 3/4" x 20
2" x 16
2" x 18
2" x 20
2 1/8" x 16
2 1/8" x 18
2 1/8" x 20
0.139
0.221
0.335
0.302
0.383
0.416
0.464
0.721
0.545
0.829
0.626
0.938
0.708
1.047
0.789
1.156
0.870
1.265
0.951
1.373
1.032
1.483
1.114
2.253
1.700
1.276
2.398
1.809
1.357
9950
6395
5280
4670
3680
3420
3035
3525
2600
3060
2260
2700
2000
2425
1790
2200
1630
2010
1490
1850
1370
1700
1270
2015
1495
1110
1890
1400
1045
9590
6170
5095
4500
3550
3300
2930
3400
2500
2950
2180
2600
1925
2340
1725
2125
1570
1940
1435
1785
1320
1650
1225
1945
1445
1070
1825
1350
1000
8200
5280
4360
3860
3040
2825
2500
2900
2145
2530
1865
2235
1650
2000
1480
1820
1345
1660
1230
1530
1130
1415
1050
1665
1235
915
1560
1160
860
6425
4130
3400
3020
2380
2200
1960
2280
1675
1980
1460
1750
1290
1565
1155
1420
1050
1300
960
1195
885
1100
820
1300
965
715
1220
900
675
19
66.7 x 1.63
66.7 x 1.22
76.2 x 1.63
101.6 x 1.63
2 5/8" x 16
2 5/8" x 18
3" x 16
4" x 16
2.981
2.245
3.417
4.581
1520
1135
1330
990
1470
1095
1280
955
1260
935
1100
820
985
730
860
640
ANNEALED COIL
Size
(mm)
Inches
& SWG
Nominal
kg/m
* Safe Working Pressure KPa
SD = 33.9
50-75°C
SD = 32.7
100-125°C
SD = 28.0
150-175°C
SD = 21.9
175-200°C
4.8 x 0.91
4.8 x 0.71
4.8 x 0.56
6.4 x 1.22
6.4 x 0.91
6.4 x 0.71
6.4 x 0.56
7.9 x 0.91
7.9 x 0.71
7.9 x 0.56
9.5 x 0.91
9.5 x 0.71
9.5 x 0.56
12.7 x 0.91
12.7 x 0.81
12.7 x 0.71
12.7 x 0.56
15.9 x 0.91
15.9 x 0.81
15.9 x 0.71
15.9 x 0.56
19.1 x 0.91
19.1 x 0.71
22.2 x 0.91
3/16 x 20
3/16 x 22
3/16 x 24
1/4 x 18
1/4 x 20
1/4 x 22
1/4 x 24
5/16 x 20
5/16 x 22
5/16 x 24
3/8 x 20
3/8 x 22
3/8 x 24
1/2 x 20
1/2 x 21
1/2 x 22
1/2 x 24
5/8 x 20
5/8 x 21
5/8 x 22
5/8 x 24
3/4 x 20
3/4 x 22
7/8 x 20
0.098
0.081
0.066
0.176
0.139
0.113
0.091
0.180
0.144
0.116
0.221
0.176
0.141
0.302
0.271
0.239
0.191
0.383
0.343
0.303
0.241
0.464
0.366
0.545
13940
10400
7950
14040
9950
7520
5795
7840
5965
4620
6395
4890
3795
4670
4125
3590
2800
3680
3250
2840
2220
3030
2340
2595
13450
10040
7600
13540
9595
7250
5640
7580
5750
4450
6170
4700
3660
4500
3980
3460
2700
3550
3140
2740
2144
2930
2260
2500
11520
8600
6560
11600
8215
6200
4830
6470
4920
3800
5280
4030
3130
3860
3400
2965
2315
3040
2690
2340
1835
2500
1940
2145
9000
6700
5100
9000
6400
4850
3775
5060
3850
2980
4100
3150
2450
3020
2665
2320
1810
2380
2100
1830
1435
1960
1500
1670
* Safe working pressures calculated for annealed copper.
20
AS 1572 : 1998 (Copper - Seamless tubes for engineering purposes).
This Standard specifies seamless copper and copper alloy tubes for general purposes. It does not apply for heat
exchangers or tubes for airconditioning.
NZS 3501 : 1976 (Copper Tubes for water, gas and sanitation)
This copper tube is manufactured in straight lengths, in half hard condition and in fully annealed coils.
Table 1 - Copper Tubes For Water and Gas
Nominal
Bore*
Outside Diameter
Thickness
Hydrostatic
test
pressure
Max. working pressure #
Max. Min. Annealed Coil Half-hard As drawn
mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70
15 (½)
20 (¾)
25 (1)
32 (1¼)
40 (1½)
50 (2)
65 (3)
80
90 (3½)
100 (4)
14.73
21.08
27.43
34.19
40.54
53.24
65.94
79.45
92.56
105.66
14.65
21.00
27.35
34.11
40.46
53.16
65.79
79.30
92.41
105.51
1.02
1.02
1.02
1.22
1.22
1.22
1.22
1.63
1.83
2.03
5.55
3.90
2.95
2.85
2.40
1.85
1.50
1.65
1.60
1.55
6.85
4.70
-
-
-
-
-
-
-
-
8.95
6.10
4.65
4.45
3.70
2.80
-
-
-
-
-
-
-
-
-
-
2.65
2.95
2.80
2.75
Table 2 - Copper Tubes For Sanitation
Nominal
Bore*
Outside Diameter
Thickness
Hydrostatic
test
pressure
Max. working pressure #
Max. Min. Annealed Coil Half-hard As drawn
mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70
25 (1)
32 (1¼)
40 (1½)
50 (2)
65 (2½)
80 (3)
90 (3½)
27.43
34.19
40.54
53.24
65.94
79.04
92.15
27.35
34.11
40.46
53.16
65.79
78.89
92.00
1.02
1.22
1.22
1.22
1.22
1.42
1.63
2.95
2.85
2.40
1.85
1.50
1.45
1.40
-
-
-
-
-
-
-
4.65
4.45
3.75
2.80
-
-
-
-
-
-
-
2.65
2.55
2.50
21
100 (4)
125 (5)
150 (6)
200 (8)
104.85
130.25
156.06
194.50
104.70
130.00
155.76
194.25
1.63
1.63
1.83
3.00
1.25
1.00
0.95
1.25
-
-
-
-
-
-
-
-
2.20
1.80
1.65
2.20
Table 3 - Light Gauge Copper Tubes For Water and Gas
Nominal
Bore*
Outside Diameter
Thickness
Hydrostatic
test
pressure
Max. working pressure #
Max. Min. Annealed Coil Half-hard As drawn
mm mm mm mm MPa MPa F=46 MPa F=60 MPa F=70
15 (½)
20 (¾)
14.73
21.08
14.65
21.00
0.7
0.9
3.80
3.40
-
-
6.00
5.35
-
-
* The figures in brackets are the previous imperial inch dimensions
# Maximum working pressure at temperatures up to 65°C, from the following formula:
P=
2Ft
D-t
WHERE: P = PRESSURE (MPa)
F = ALLOWABLE STRESS FACTOR (MPa)
t = THICKNESS (mm)
D = OUTSIDE DIAMETER (mm)
1.Solder Joint Copper Fittings-ANSI/ASME B16.22-2001
C X CMueller Style: WE-500 5/8″Elkhart Style: 107-C 3/4″ O.D. SizeNibco Style: 9607-1 7/8″ 1/4″
1″ 3/8″1-1/8″ 1/2″1-1/4″ 5/8″1-3/8″ 3/4″1-1/2″ 7/8″1-5/8″ 1″1-3/4″ 1-1/8″2-1/8″ 1-3/8″2-5/8″ 1-5/8″
O.D. Size 3-1/8″ 2-1/8″1/4″ 3-5/8″ 2-5/8″
5/16″ 4-1/8″ 3-1/8″3/8″ 5-1/8″ 3-5/8″1/2″ 6-1/8″ 4-1/8″
5/8″3/4″ O.D. Size7/8″ 1/4″1″ 3/8″
1-1/8″ 1/2″1-1/4″ 5/8″1-3/8″ 3/4″1-1/2″ 7/8″1-5/8″ 1″1-3/4″ 1-1/8″2-1/8″ 1-3/8″2-5/8″ 1-5/8″
O.D. Size 3-1/8″ 2-1/8″1/4″ 3/5/8″ 2-5/8″
5/16″ 4/1/8″ 3-1/8″3/8″ 5-1/8″ 3-5/8″1/2″ 6-1/8″ 4-1/8″
Nibco style:9606-2
FTG X C
45ºElbow
Nibco style:9606
Mueller style:WE-505
45ºElbowC X C
Mueller style:WE-504
Elkhart style:106
90ºElbow-Short Radius
FTG X CMueller Style: WE-503Elkhart Style: 107-C-2Nibco Style: 9607-2
90ºElbow-Short Radius
Elkhart style:106-2
Copper Fittings Supplier
1/2″5/8″ 1/2″3/4″ 5/8″7/8″ 3/4″1″ 7/8″
1-1/8″ 1″1-1/4″ 1-1/8″1-3/8″ 1-1/4″1-5/8″ 1-3/8″2-1/8″ 1-5/8″2-5/8″ 2-1/8″
O.D. Size 3-1/8″ O.D. Size 2-5/8″1/4″ 3-5/8″ 1/4″ 3-1/8″3/8″ 4-1/8″ 3/8″ 4-1/8″
O.D. Size3/4″ 1/4"7/8″ 3/8"1″ 1/2"
1-1/8″ 5/8"1-1/4″ 3/4"1-3/8″ 7/8"1-1/2″ 1-1/8"1-5/8″ 1-3/8"1-3/4″ 1-5/8"2-1/8″ 2-1/8"
O.D. Size 2-5/8″ 2-5/8"1/4″ 3-1/8″ 3-1/8"
5/16″ 3-5/8″ 4-1/8"3/8″ 4-1/8″1/2″ 5-1/8″5/8″ 6-1/8″
Elkhart style:11
Nibco style:9611
Cap C
Elkhart Style: 117Nibco Style: 9617
Mueller Style: WC-415Equal Tee C X C X CMueller style:WT-600
90ºElbow-Long RadiusC X C
Mueller style:WE-500L
90ºElbow-long RadiusFTG X C
Mueller style:WE-503L
Elkhart style:107-L
Nibco style:9607-L
Elkhart style:107-L-2
Nibco style:9607-2-LT
1-3/8 x1-3/8 x 5/8
Reducing Tee C X C X C
3-1/8 x 3-1/8 x 1-1/83-1/8 x 3-1/8 x 1-3/8
3-1/8 x 3-1/8 x 2-5/8
1-3/8 x1-3/8 x 7/8
3-1/8 x 3-1/8 x 2-1/83-1/8 x 3-1/8 x 1-5/8
2-5/8 x 2-5/8 x 1-1/8
7/8 x 7/8 x 3/47/8 x 7/8 1-1/8
O.D. Size O.D. Size
2-5/8 x 2-5/8 x 5/8
4-1/8 x 4-1/8 x 3-1/8
4-1/8 x 4-1/8 x 1-1/8
2-5/8 x 2-5/8 x 2-1/8
1-1/8 x 7/8 x 7/81-1/8 x 1-1/8 x 3/8
7/8 x 5/8 x 7/8 3-1/8 x 3-1/8 x 7/8
1-1/8 x 7/8 x 5/8
7/8 x 7/8 x 5/8
Elkhart style:11
Nibco style:9611
Mueller style:WT-600
1-3/8 x1-3/8 x 1-5/81-3/8 x1-3/8 x 1-1/8
5-1/8 x 5-1/8 x 4-1/8
1-5/8 x 1-5/8 x 2-5/84-1/8 x 4-1/8 x 1-1/84-1/8 x 4-1/8 x 1-3/84-1/8 x 4-1/8 x 1-5/8
5/8 x 1/2 x 1/24-1/8 x 4-1/8 x 2-5/8
1-3/8 x1-3/8 x 3/8
1-1/8 x 1-1/8 x 1-3/81-1/4 x 1-1/4 x 1
1-3/8 x 1-1/8 x 1-1/8
1-1/8 x 1-1/8 x 1
6-1/8 x 6-1/8 x 4-1/86-1/8 x 6-1/8 x 5-1/8
4-1/8 x 4-1/8 x 2-1/8
5/8 x 5/8 x 3/4
1-1/8 x 1-1/8 x 7/8
1-1/8 x 5/8 x 5/8
4-1/8 x 4-1/8 x 1-5/84-1/8 x 4-1/8 x 2-1/84-1/8 x 4-1/8 x 2-5/8
6-1/8 x 6-1/8 x 3-1/8
4-1/8 x 4-1/8 x 3-1/85-1/8 x 5-1/8 x 3-1/85-1/8 x 5-1/8 x 4-1/8
5-1/8 x 5-1/8 x 3-1/8
6-1/8 x 6-1/8 x 3-1/8
1-3/8 x 7/8 x 7/81-5/8 x 1-3/8 x 1-3/81-5/8 x 1-5/8 x 5/8
1-5/8 x 1-5/8 x 2-1/8
7/8 x 5/8 x 5/8
2-5/8 x 2-5/8 x 1-3/82-5/8 x 2-5/8 x 1-5/8
1-3/8 x1-3/8 x 1/2
1-1/8 x 1-1/8 x 1/21-1/8 x 1-1/8 x 5/81-1/8 x 1-1/8 x 3/4
6-1/8 x 6-1/8 x 4-1/86-1/8 x 6-1/8 x 5-1/8
4-1/8 x 4-1/8 x 1-3/8
7/8 x 7/8 x 3/87/8 x 7/8 x 1/2
5/8 x 5/8 x 7/83/4 x 5/8 x 5/83/4 x 3/4 x 3/83/4 x 3/4 x 1/23/4 x 3/4 x 5/83/4 x 5/8 x 3/4
5/8 x 3/8 x 5/85/8 x 5/8 x 1/45/8 x 5/8 x 3/85/8 x 5/8 x 1/2
5/16 x 5/16 x 1/43/8 x 3/8 x 1/43/8 x 1/4 x 3/8
3/8 x 3/8 x 5/161/2 x 3/8 x 1/41/2 x 1/2 x 1/41/2 x 1/2 x 3/85/8 x 3/8 x 1/2
Coupling O.D. Size 1-1/8 x 3/8
1/4" 1-1/8 x 1/2
5/16" 1-1/8 x 5/8
3/8" 1-1/8 x 3/41/2" 1-1/8 x 7/85/8" 1-1/8 x 13/4" 1-3/8 x 3/87/8" 1-3/8 x 1/21" 1-3/8 x 5/8
1-1/8" 1-3/8 x 3/41-1/4" 1-3/8 x 7/8
1-3/8"" 1-3/8 x 1-1/81-1/2" 1-5/8 x 5/81-5/8" 1-5/8 x 3/41-3/4" 1-5/8 x 7/8
2-1/8" 1-5/8 x 1-1/8
2-5/8" 1-5/8 1-3/8
3-1/8" 2-1/8 x 1/2C X C 3-5/8" 2-1/8 x 5/8
4-1/8" 2-1/8 x 7/85-1/8" 2-1/8 x 1-1/86-1/8" 2-1/8 x 1-3/8
2-1/8 x 1-5/82-5/8 x 5/82-5/8 x7/8
2-5/8 x 1-1/82-5/8 x 1-3/82-5/8 x 1-5/8
O.D. Size 2-5/8 x 2-1/81/4 x 3/16 3-1/8 x 1-1/83/8 x 1/4 3-1/8 x 1-3/8
1/2 x 1/4 3-1/8 x 1-5/8
C X C 1/2 x 5/16 3-1/8 x 2-1/81/2 x 3/8 3-1/8 x 2-5/85/8 x 1/4 3-5/8 x 3-1/85/8 x 3/8 4-1/8 x 1-1/85/8 x 1/2 4-1/8 x 1-3/83/4 x 3/8 4-1/8 x 1-5/83/4 x 1/2 4-1/8 x 2-1/83/4 x 5/8 4-1/8 x 2-5/87/8 x 1/4 4-1/8 x 3-1/87/8 x 3/8 4-1/8 x 3-5/87/8 x 1/2 4-1/8x 2-1/87/8 x 5/8 5-1/8 x 3-1/87/8 x 3/4 5-1/8 x 4-1/8
Elkhart Style: 100
Elkhart Style: 101
Nibco Style: 9600-DS
Coupling
C X C – Staked Stop
Nibco Style: 9601
–Rolled StopCoupling
Coupling-No Stop
Elkhart Style: 100Nibco Style:9600-RS
Mueller Style: WC-400NS
Mueller Style: WC-400
Mueller Style: WC-400S Elkhart Style: 101-R
Reducing Coupling
Fitting ReducerFTG X C
Nibco Style: 9600-2Elkhart Style: 118Mueller Style: WC-403
Mueller Style: WC-400R
Nibco Style: 9600
C X C
Return BendC X C C X C
1/2×1-1/2 1-3/8 x 7/81/2×3 1-3/8 x 1-1/8
5/8×1-7/8 1-5/8 x 1-1/85/8×2 1-5/8 x 1-3/8
5/8×2-1/4 2-1/8 x 1-1/83/4×2-1/2 2-1/8 x 1-3/87/8×2-1/2 2/1/8 x 1-5/81-1/8×3 2-5/8 x 1-1/8
1-1/8×3-1/4 2-5/8 x 1-3/81-3/8×3 2-5/8 x1-5/8
1-3/8×3-3/4 2-5/8 x 2-1/8O.D. Size 1-3/8×4 O.D. Size 3-1/8 x 1-5/8
1/4×1 1-5/8×3-1/2 5/8 x 1/2 3-1/8 x 2-1/83/8×1-1/2 1-5/8×4-1/2 7/8 x 5/8 3-1/8 x 2-5/83/8×4-1/2 2-1/8×5-1/2 1-1/8 x 5/8 4-1/8 x 2-5/8
1-1/8 x 7/8 4-1/8 x 3-1/8
Nominal. Size C x C O.D. Size1/4" 1/2"3/8" 5/8"1/2" 3/4"3/4" 7/8"1" 1-1/
1-1/4" 1-3/8"1-1/2" 1-5/8"
2" 2-1/8"2-1/2"
3"
4"
C X M Nominal. Size C x C O.D. Size1/4" 5/8"3/8" 3/4"1/2" 7/8"3/4" 1-1/8"1" 1-3/8"
1-1/4" 1-5/8"1-1/2" 2-1/8"
2"2-1/2"
3"4"
Reducing 90°Elbow
Mueller Style: WE-500Elkhart Style: 107-CNibco Style: 9607-1
Elkhart Style: 123Nibco Style: 9698
Mueller Style: WE-512Elkhart Style: 138
Suction Line P-Traps
Mueller Style: WE-554P
Nibco Style: 9638
Female Adapter C X FMueller Style: WC-402
Cross-Over Coupling
Nibco Style : 9636
Nibco Style: 9604
Elkhart Style: 103
Elkhart Style: 104
Nibco Style: 9603
Male Adapter
Mueller Style: WC-401
Cross-Over CouplingC x C C X C
Nibco Style : 9636 O.D. Size5/8"7/8"
1-1/8"
2.Solder Ring Copper Fittings-ANSI/ASME B16.22-2001
C x C O.D. Size O.D. Size1/4 1/43/8 3/81/2 1/25/8 5/83/4 3/41 1
1-1/4 1-1/41-1/2 1-1/2
2 2
C x C O.D. Size O.D. Size1/4 1/43/8 3/81/2 1/25/8 5/83/4 3/41 1
1-1/4 1-1/41-1/2 1-1/2
2 2
Union
1-3/81-5/82-1/82-5/8
O.D. Size
1-1/8
1/25/87/8
45°Elbow 45°Elbow
FTG x C90°Elbow-Short Radius 90°Elbow-Short Radius
FTG x C
3-1/8
4-1/8
O.D. Size
1/43/81/25/83/41
1-1/41-1/22
1/2 x 3/8 x 3/85/8 x 1/2 x 1/23/4 x 1/2 x 1/23/4 x 1/2 x 3/41 x 1/2 x 1/21 x 3/4 x 1/21x 3/4 x 3/4
1-1/4 x 3/4 x 3/41-1/4 x 1 x 1
O.D. Size 1-1/2 x 1-1/4 x 1-1/41/2 x 1/4 x 3/8 2 x 1-1/4 x 1-1/41/2 x 1/4 x 1/2 2 x 1-1//2 x 1-1/2
O.D. Size3/8 x 3/8 x 1/21/2 x 1/2 x 5/81/2 x 1/2 x 3/43/4 x 3/4 x 1 O.D. Size1 x 1 x1-1/4 1/4
1-1/4 x 1-1/4 x 1-1/2 3/81-1/2 x 1-1/2 x 2 1/2
5/83/41
1-1/41-1/2
2
C x C x C
Reducing Tee
TeeEqual Tee
Reducing TeeC x C x C
O.D. Size
1/2 x 1/2 x 3/8
Reducing TeeC x C x C 1/2 x1/2 x 1/4
3/8 x 3/8 x 1/4
3/4 x 3/4 x 5/81x 1x 1/21x1x5/8
5/8 x 5/8 x 1/23/4 x 3/4 x 3/8
C x C x C
1-1/2 x 1-1/2 x11-1/2 x 1-1/2 x 1-1/4
2 x 2 x 1
2 x 2 x 1-1/42 x 2 x 1-1/2
Cap C
1x1x3/41/4x1-1/4x3/4
1-1/4 x 1-1/4 x 11-1/2 x 1-1/2 x 3/4
3/4 x 3/4 x 1/2
Nominal. Size Nominal. Size1/4 1/43/8 3/81/2 1/23/4 3/41 1
1-1/4 1-1/41-1/2 1-1/2
2 2
Reducing Coupling
C×CO.D. Size
1/43/81/25/83/41
1-1/4 Fitting Reducer1-1/2 FTG x C
Coupling-No Stop 2
5/8 x 1/2
1-1/4 x 11-1/2 x 1
2x1-1/4
Male Adapter Female Adapter
Coupling-Roll Stop C×C
C×C
C x M C x F
Coupling
3/4 x 3/83/4 x 1/23/4 x 5/8
2x 1-1/2
1-1/2 x 1-1/42x1
1 x 1/2
1x5/8
1x 3/4
1-1/4 x 5/8
1-1/4 x 3/4
5/8 x 3/8
O.D. Size
3/8 x 1/4
1/2 x 3/8
top related