“liquid incineration” for a cleaner environment the vtx process innovative remediation...

Post on 16-Dec-2015

215 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

“Liquid Incineration” for a Cleaner Environment

The VTX Process

Innovative Remediation Technologies, Inc

• VTX is an organic catalyst that reacts with various oxidizing agents to produce hydroxyl radicals.

• No sludge is produced as a result of the process in normal use.

• Safe and easy to apply.

• Application of catalyst requires no materials of special construction.

VTX VTX

Relative Oxidation Potential Reactive Species Relative Oxidation Power* Fluorine 2.23 Hydroxyl radicals 2.06 Atomic oxygen (singlet) 1.78 Ozone 1.52 Persulfate 1.48 Hydrogen peroxide 1.31 Permanganate 1.24 Hypochlorous acid 1.10 Chlorine 1.00*

Odor & Corrosion Control

Treatment of Sulfide

The VTX ProcessTreatment of Sulfide• VTX rapidly converts

sulfide (H2S, HS-, S=) to elemental sulfur.

• Immediate reduction of odor and corrosion due to H2S.

• VTX is suited for control of sulfide in:

Landfills

Food Production

Animal Waste

Municipal and Industrial Wastewater Treatment

0

20

40

60

80

100

Part

s Pe

r Mill

ion

BeforeTreatment

After 1Minute

After 2Minutes

After 3Minutes

Rapid Oxidation ofSulfide

Reaction Time and Dosage Comparison:

H2O2 Alone vs. VTX ProcessTreatment of Hydrogen Sulfide

Hydrogen Peroxide AloneH2S + H2O2 S0 + 2H2OReaction time: 20-30 minutesEffective dosage (mass H2O2/mass H2S): 1.5 to 4.0 : 1.0

VTX ProcessH2S + VTX /H2O2 S0 + 2H2O + salts + CO2 + [VTX]*Reaction time: <3 minutesEffective Dosage (mass VTX/mass H2S): 1.5 to 2.5: 1.0* Note: [VTX] = remaining un-reacted VTX

0

5

10

15

20

0 5 10 15 20 25 30Time (minutes)

Su

lfid

e (

pp

m)

Peroxide Dosage at 2.5 times the Mass of Sulfide

Comparative Treatment of Sulfides in Wastewater Hydrogen Peroxide vs. VTX Process

H2O2 only H2O2 w/ variable VTX dosages

Corrosion Control

Melbourne, Florida3 year old pipe

Melbourne, Florida3 year old pipe

N. Brevard, Florida Headworks7 years old – currently closed for repairs

Estimated Affect of S= on Infrastructure Life Expectancy

(3’ Diameter Concrete Pipe in Gravity Sewer)

S= (ppm) Life Expectancy (Years)* 0.5 >50 1.0 25-50 1.5 25 2.0 10-25 2.5 10 3.0 10 4.0 5-10 7.0 5 >7.0 <5*Varies based on alkalinity and pH scenarios

Capital and Operational Savings

The VTX Catalytic Process can rapidly eliminate >95% of the

sulfides entering the headworks of a wastewater plant.

York River STPScrubber Influent H2S

Treatment initiated @ 06:45, Stopped @ 14:45

Case StudyCalifornia Wastewater Treatment Plant

Case StudyCalifornia Wastewater Treatment Plant

Before and After TreatmentMelbourne, Florida Lift Station

Atmospheric H2S

Before and After TreatmentMelbourne, Florida Lift Station

Aqueous Sulfide

02

468

101214

161820

Par

ts P

er M

illio

n (

pp

m)

12:00 AM

1:00 AM

2:00 AM

3:00 AM

4:00 AM

5:00 AM

6:00 AM

7:00 AM

8:00 AM

9:00 AM

10:00 AM

11:00 AM

12:00 PM

1:00 PM

2:00 PM

3:00 PM

4:00 PM

5:00 PM

6:00 PM

7:00 PM

8:00 PM

9:00 PM

10:00 PM

11:00 PM

Time of Day

Before Treatment After Treatment

024

68

1012

141618

20

Par

ts P

er M

illio

n (

pp

m)

12:00 AM

1:00 AM

2:00 AM

3:00 AM

4:00 AM

5:00 AM

6:00 AM

7:00 AM

8:00 AM

9:00 AM

10:00 AM

11:00 AM

12:00 PM

1:00 PM

2:00 PM

3:00 PM

4:00 PM

5:00 PM

6:00 PM

7:00 PM

8:00 PM

9:00 PM

10:00 PM

11:00 PM

Time of Day

0

5

10

15

20

25

30

Pa

rts

pe

r M

illi

on

(p

pm

)

7:00 8:15 9:30 10:45 12:00 13:15

Time of Day

VTX - Turned On

VTX - Turned Off

VTX Sludge Treatment StudyTotal Sulfide Destruction

Springville, Utah Wastewater Treatment Plant

VTX Calibration Period

VTX Facts

• VTX for treatment of organic and selected inorganic chemicals is patent pending.

• VTX as a disinfectant is also patent pending.

• VTX is EPA TSCA approved for use in the environment.

top related