lighting analysis library ashutosh aniruddh

Post on 12-Jul-2015

271 Views

Category:

Design

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Lighting Analysis

Mahatma Gandhi Central Library,

IIT Roorkee

Aniruddh Jain and Jha Ashutosh

Floor Plan

Ground Floor

Plan

Study Area:

Reading Room

Reading Room

Plan with doors windows and columns.

Reading Room Images

Reading

Locations

J

I

H

G

F

E

D

C

B

A

1 2

Artificial Light Fixtures

Type Quantity Wattage

Non-integrated bi-pin

double-turn CFL

26w Radium G24d-3

Warm White

[26w - 149mm long,

27mm diameter]

28 26W

T8 4 ft tube 4 36WJ

I

H

G

F

E

D

C

B

A

1 2

Illuminance (Lumen/Sqm)A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 F1 F2 G1 G2 H1 H2 I1 I2 J1 J2

9AM 360 780 420 650 398 580 420 690 380 810 410 780 480 650 430 630 380 640 430 560

12PM 920 1350 960 1280 840 940 880 1020 780 920 840 1240 780 1070 910 960 870 1100 820 1400

3PM 840 1000 940 1200 860 920 750 970 800 950 820 1020 760 980 800 950 890 900 850 1200

6PM 153 230 180 210 90 190 110 210 110 220 100 180 70 110 80 120 80 120 90 180