2011/7/4 1
IEC/EN 61347-2-13
LED Driver IEC/EN 61347-2-13 的驗證要求說明LED Driver IEC/EN 61347-2-13 的驗證要求說明
.
-
2011/7/4 2
IEC/EN 61347-2-13
本課程主要內容
IEC/EN 61347 標準介紹
名詞定義
標示
零件要求
結構要求
測試項目
-
2011/7/4 3
IEC/EN 61347-2-13
IEC/EN 61347 系列標準介紹
一般要求: IEC 61347-1:2007, EN 61347-1:2008Lamp controlgear-Part 1: General and safety requirements
常用的 Part 2 個別要求 (Particular requirements)
IEC/EN 61347-2-1: for starting devices other than glow starter (Ignitor, Electronic starter) --- 點火器
IEC/EN 61347-2-2: for d.c. or a.c. supplied electronic step-down convertors forfilament lamps) --- 電子式變壓器
IEC/EN 61347-2-3: for a.c. supplied electronic ballasts for fluorescent lamps --- 電子式安定器
-
2011/7/4 4
IEC/EN 61347-2-13
常用的 Part 2 個別要求 (Particular requirements)
IEC/EN 61347-2-8: for ballast for fluorescent lamps (Winding type ballast) --- 線圈式安定器
IEC/EN 61347-2-9: Particular requirements for ballast for discharge lamp excluding fluorescent lamps (Winding type ballast) --- HID 安定器
IEC/EN 61347-2-10: for electronic invertors and convertor for high-frequencyoperation
IEC/EN 61347-2-11: for miscellaneous electronic circuits used with luminaires
IEC/EN 61347-2-12: for Electronic ballast for discharge lamp (HID Ballast) --- HID 電子式安定器
IEC/EN 61347-2-13: for d.c. or a.c. supplied electronic controlgear for LED modules --- 照明用LED 電源供應器
-
2011/7/4 5
IEC/EN 61347-2-13
IEC 61347-1: 2007EN 61347-1: 2008Lamp controlgear-General and safety requirements
IEC 61347-2-13: 2006EN 61347-2-13: 2006Particular requirements for d.c. or a.c. suppliedelectronic controlgear for LED modules
-
2011/7/4 6
IEC/EN 61347-2-13
IEC/EN 61347-2-13 的應用範圍
電源輸入:
≤ 250 Vdc 或≤ 1000 Vac, 50Hz or 60Hz
輸出電壓:
SELVSELV equivalent (等效SELV)Higher voltages
-
2011/7/4 7
IEC/EN 61347-2-13
名詞定義
-
2011/7/4 8
IEC/EN 61347-2-13
名詞定義
-
2011/7/4 9
IEC/EN 61347-2-13
Built in controlgear ?(內置於燈具, 線盒, 外殼內)
Independent SELV controlgear ?(可裝置於燈具外無須額外之外殼, 且具有其標示所示之保護功能)
Additional compliance of Annex I
符合 IEC 60598-1 相關要求
-
2011/7/4 10
IEC/EN 61347-2-13
Built in type or Independent type ?
-
2011/7/4 11
IEC/EN 61347-2-13
Marking:
必須標示
依產品狀況而定
50/60Hz
-
2011/7/4 12
IEC/EN 61347-2-13
Marking:
其它標示要求如下:
可更換零件的清楚說明
接地符號
定電壓輸出形式的產品: 額定輸出電壓 (V)
定電流輸出形式的產品: 額定輸出電流 (A), 額定最大輸出電壓 (V)
The controlgear is suitable for operation with LED modules only.
(只供 LED 模組使用)
-
2011/7/4 13
IEC/EN 61347-2-13
Marking or manufacturer’s catalogue or similar:
-
2011/7/4 14
IEC/EN 61347-2-13
-
2011/7/4 15
IEC/EN 61347-2-13
Fail-safe controlgear不正確使用下功能失效,無危險性
Non-short-circuit proof controlgear 無短路保護
Short-circuit proof controlgear具短路保護
Inherently short-circuit proof controlgear 保護元件失效下, 過載或短路時溫度不會超過限制值,過載或短路移除後產品可恢復正常運作
Non-inherently short-citcuitproof controlgear 過載或短路時,保護元件動作
-
2011/7/4 16
IEC/EN 61347-2-13
必須符合 DIN VDE 0710-14
組裝說明書或使用手冊, 必須標示產品使用時的周圍環境,
範例圖示如下:
? mm
? mm
? mm ? mm
-
2011/7/4 17
IEC/EN 61347-2-13
不正常運作下, 外殼最高溫度 ≤ 130°C
不正常運作下, 外殼最高溫度 ≤ 110°C
正常運作下, 外殼最高溫度 ≤ 95°C
不正常運作下, 外殼最高溫度 ≤ 115°C
tc 正常運作下, 外殼最高溫度 ≤ tc°C
-
2011/7/4 18
IEC/EN 61347-2-13
Components:
重要零件需提供歐規TUV或VDE(IEC/EN)證書
電流保險絲必須為歐規認可品
Independent controlgear 的電源線絕緣材質必須為歐規認可品, 且電源
線線徑必須至少 0.75 mm2
若產品定義防水防塵 (IP code) (IPX1 or higher),
則 independent controlgear 的電源線絕緣材質必須是橡膠
(rubber, H05RN-F), 且線徑必須至少 1.0 mm2
-
2011/7/4 19
IEC/EN 61347-2-13
Construction: Built in SELV controlgear:
Primary Secondary
Earth
L
N
Cl. 1.7mmCr. 2.5mm
B: Cl. 2.0mmB: Cr. 2.5mm
R: Cl. 4.0mmR: Cr. 5.0mm
R: Reinforced insulation
B: Basic insulation
Between fuse terminations: Cr. 2.5mm, Cl. 1.7mm
變壓器絕緣距離 依工作電壓查表 (IEC60065, Tables 8-11)
Supposed Input 250Vac
?
-
2011/7/4 20
IEC/EN 61347-2-13
Construction: Independent SELV controlgear:
Primary Secondary
Earth
L
N
Cl. 3.0mmCr. 3.0mm
B: Cl. 3.0mmB: Cr. 3.0mm
R: Cl. 6.0mmR: Cr. 6.0mm
R: Reinforced insulation
B: Basic insulation
S: Supplementary insulation
S: Cl./ Cr. 依工作電壓查表
Between fuse terminations: Cr. 3.0mm, Cl. 3.0mm
變壓器絕緣距離 依工作電壓查表 (IEC 61347-2-13, Table I.7)
Earthed enclosure
Supposed Input 250Vac
no connection
-
2011/7/4 21
IEC/EN 61347-2-13
Construction: Independent SELV controlgear:
Primary Secondary
R: Reinforced insulation
Plastic Enclosure
R: Cl. 6.0mmR: Cr. 6.0mm
R: Cl. 6.0mmR: Cr. 6.0mm
R: Cl./ Cr. 依工作電壓查表
Supposed Input 250Vac
user accessible part
-
2011/7/4 22
IEC/EN 61347-2-13
Construction: Independent SELV controlgear:
Distance through insulation (R) - three layers of thin sheet insulation: 0.3mm (output > 100VA)
0.2mm (output: 25VA ∼ 100VA) 0.1mm (output: < 25VA)
S
P
P
-
2011/7/4 23
IEC/EN 61347-2-13
Construction: Independent SELV controlgear:
Distance through insulation (R): 1.0mmInput terminals output terminals: ≥ 25 mm
-
2011/7/4 24
IEC/EN 61347-2-13
Construction: Screw Terminal clause 14 of IEC 60598-1
‧線材的線徑必須能完全插入terminal,且必須完全被夾住
‧線材在螺絲鎖完後不能鬆落
‧線材線徑大小必須符合規範要求
常見的 screw terminal
-
2011/7/4 25
IEC/EN 61347-2-13
Construction: Screwless Terminal clause 15 of IEC 60598-1
常見的 screwless terminal
-
2011/7/4 26
IEC/EN 61347-2-13
Test Items: - Discharge test (1 min., ≤ 50V)- Protection of contact with live part: 10N force- Output exposed terminals test (for SELV-or SELV
equivalent controlgear)< 25 Vrms under load < 33 Vrms or 33√2 Vpeak under no-load
- Grounding test25A/1min. < 0.5 Ω
- Humidity test 91-95%, 20-30°C, 48h
-
2011/7/4 27
IEC/EN 61347-2-13
Test Items: - Insulation resistance test (immediately after humidity)
500V, 1min. B: > 2MΩ, D/R: > 4MΩ- Electric strength test Output circuit metal enclosure ?
-
2011/7/4 28
IEC/EN 61347-2-13
Supplementary information:
-
2011/7/4 29
IEC/EN 61347-2-13
Test Items: Transformer Heating test
Normal operation: comply IEC 60065 Table 3Abnormal operation: comply IEC 60065 Table 3
-
2011/7/4 30
IEC/EN 61347-2-13
Test Items: Heating test
Enclosure for testing: Annex F
Annex D
Note: Temp. shall be measured under ta.
-
2011/7/4 31
IEC/EN 61347-2-13
Test Items: - Fault condition test (component failure)
(temp. shall be measured under enclosure temp. tc)- Abnormal test (test for 1 hour)
I/P: -10%/+10% of supply voltageLength of cable for testing: 20cm and 200cmFor constant voltage output type* No LED module inserted* Double the LED module load (two LEDs connected in parallel)* Output shorted (multiple output, each output short-circuite in turn)
(temp. shall be measured under enclosure temp. tc)
-
2011/7/4 32
IEC/EN 61347-2-13
Test Items: - For constant current output type
* No LED module inserted* Double the LED module load (two LEDs connected in series)* Output shorted
(multiple output, each output short-circuite in turn)
(temp. shall be measured under enclosure temp. tc)
-
2011/7/4 33
IEC/EN 61347-2-13
Test Items: - Power cord pull test:
60N, 0.15Nm displacement < 2.0mm
- Torque test for screw terminal 測試次數: 5 次測試力距: 依照 IEC 60598-1 Table 14.4 或 Figures 12-16 中適用螺絲的力距, 以較大的力距測試
-
2011/7/4 34
IEC/EN 61347-2-13
Test Items: - Live part measurement
I/P: rated voltage* Measured according to IEC60990 circuit (measured point: part concerned earth)
* non-inductive resistance 50kΩ, >34Vpeak is live part (measured point: part concerned accessible part)
U2/500 mA
Note: one pole of the test supply shall be at earth potential.
-
2011/7/4 35
IEC/EN 61347-2-13
Test Items: - Ball pressure test
* 125°C for parts retaining live parts in position* 75°C for other parts providing protection against
electric shock
- Glow-wire test650°C, 30s for external parts of insulating material
- Needle-frame test10s for insulating material retaining live parts in position
-
2011/7/4 36
IEC/EN 61347-2-13
Supplementary information:
-
2011/7/4 37
IEC/EN 61347-2-13
Test Items: For Independent SELV controlgear- Heating test (comply Table I.1)
-
2011/7/4 38
IEC/EN 61347-2-13
Test Items: For Independent SELV controlgear- Short-circuit and overload protection (comply Table I.3)
-
2011/7/4 39
IEC/EN 61347-2-13
Test Items: For Independent SELV controlgear- Insulation resistance test (according to Table I.5)
-
2011/7/4 40
IEC/EN 61347-2-13
Test Items: For Independent SELV controlgear- Electric strength test (according to Table I.6)
-
2011/7/4 41
IEC/EN 61347-2-13
判定標準: 外殼不可破裂, 導致無法符合
EN 60598其他章節之求. (例如: 帶電體可被測試手指碰觸, 防水防塵等級無法
維持等)
Test Items: For Independent SELV controlgear- Mechanical strength test (EN 60598-1 Table 4.3)
-
2011/7/4 42
IEC/EN 61347-2-13
Questions ?