Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 125 January 2005
Standards and Regulations for intelligent buildingsBRE - Garston – 27 January 2005
KNX – the European Standard for Home and Building Electronic Systems – EN 50090
Mr. J. Demarest - Konnex Certification and Administration Director
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 225 January 2005
Contents of Presentation
• The road towards KNX: the Convergence Process
• Konnex Association : current activities
• The KNX system: the technology in a nutshell
• KNX system : current technical status
• KNX : from an industry standard to a European standard
• Outlook on future international standardisation activities
• Summary
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 325 January 2005
• before 1997 : 3 major bus associations in Europe– Batibus Club International
• Promotion of Batibus solution• installation bus medium originally developed by Schneider Electric• especially successful in France• use especially in electrical material and HVAC appliances
– EIBA• Promotion of EIB solution• installation bus medium/protocol originally developed by Insta-Siemens-Merten• especially successful in German speaking countries• use especially in electrical material and HVAC appliances• Attempt to standardise EIB in the framework of CENELEC TC205 – only standardisation of HBES hardware requirements in EN 50090-2-2 succeeded
– EHSA• Promotion of European Home Systems• Bus medium/protocol emanating from a European project for automatic configuration of networked white (washing machine, …) and brown (video, …) goods
The road towards KNX: Convergence Process – history (1)
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 425 January 2005
The road towards KNX: Convergence Process – history (2)
• ‘97 : Start of the convergence process - goals– Bundling activities of BCI, EIBA, EHSA in a new association
•A non-profit organisation with registered office in Belgium• Income : annual member contributions (staggered according to company size) – certification fees
•Members : – Manufacturers, Service Providers (e.g. telecom, …) and interested parties
(e.g. software houses, …), no licensees•organisational structure: General Assembly, Executive Board, Technical and Marketing Boards (with respective expert and working groups)
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 525 January 2005
The road towards KNX: Convergence Process – history (3)
• ‘97 : Start of the convergence process - goals (ctd.)– Creation of a joint standard for a new bus system « KNX »– European Standardisation of the KNX standard by becoming co-
operation partner of CENELEC (European Committee for Electrotechnical Standardisation)
– Registration of a new trademark– Start of a Certification procedure
for KNX compatible devices
• 14 April 1999 : Founding of Konnex Association in Brussels with 9 founding members
• 20 March 2001 : first General Assembly
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 625 January 2005
Konnex : current status association
• Konnex tasks around the KNX system:– Elaboration and extension of the KNX-Specifications– Technical Hotline-support– International Standardisation– Protection of the KNX (and legacy) Trademarks– Certification of KNX compatible products– Standardisation of Training documentation – Certification of
training Centres– Communication – Promotion – National Organisations– Partnerschip for Universities and Technical Institutes –
Organisation of the annual Scientific Conference
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 725 January 2005
Konnex: current status association(s)• Non-commercial activities of Batibus, EIBA and EHSA by contract
delegated to Konnex : Konnex from April 2003 onwards responsible for:– Rest promotional activities for the legacy systems– Clarifications of the (frozen) legacy specifications (if still needed)– Support for the legacy systems (if still needed)– Certification procedure of the legacy systems EIB and EHS– Further granting of EIB Partnerships– all work in the legacy expert/working groups has in principle
been suspended• EIBA remains in existence however only for
– Specification, Marketing and sale of EIB/KNX tools (a.o. ETS)– Statutes have been changed to better reflect this reduction of activities
• Batibus transformed into Konnex France
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 825 January 2005
Konnex: miscellaneous
• Size of the current association : – Over 90 members (also companies, which had not been a
member in the legacy associations) from such fields of application as:
• Lighting control• Shutter control• Heating, Ventilation, Airconditioning• Alarm/intrusion systems• Household appliances
– Membership for new companies now only possible in Konnex
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 925 January 2005
KNX : the technology in a nutshell - overview
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween mediaRF …IP …
TP1/PL110 : original EIB TP media
PL132 : original EHS PL medium
TP0 : original Batibus Medium
RF : new KNX development
IP : new KNX development - tunneling and routing of KNX frames via IP
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1025 January 2005
KNX : the technology in a nutshell - overviewU
nified kernel
Addressing, communication and transport
Network/Device-Management
Point to Point
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween mediaRF …IP …
Common set of system mechanism for groupand point-to-point communication based on
EIB protocol
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1125 January 2005
KNX : the technology in a nutshell - overview
extended
Addressing, communication and transport
Network/Device-Management
Point to Point
Unified kernel
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween mediaRF …IP …
Extended system mechanisms forHVAC applications
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1225 January 2005
KNX : the technology in a nutshell - overview
Linking of products and parameterization by means of PC tool with product databases:
ETS 3 Professional or ETS Startersystem modesystem mode
PC based tool
‘‘SS’’
Addressing, communication and transport
Network/Device-Management U
nified kernel
Point to Point
extended
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween mediaRF …IP …
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1325 January 2005
For EIB/KNX certified contractor
Allows full flexibility
Supports entire address range + maximum number of devices
Multi-vendor and multi-application
KNX : the technology in a nutshell – ETS Professional
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1425 January 2005
For non-EIB/KNX certified contractor
CBT delivered with software - teaches system fundamentals
Maximum number of devices : 64
Only subset of products are starter-compliant
Multi-vendor and multi-application
KNX : the technology in a nutshell – ETS Starter
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1525 January 2005
easy modeeasy mode
Log. Tag(& supervised)
Push-Button
Con-troller
‘‘EE’’
Addressing, communication and transport
Network/Device-Management U
nified kernel
Point to Point
extended
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween media
system modesystem mode
PC based tool
‘‘SS’’
RF …IP …
KNX : the technology in a nutshell - overviewLinking of products
and parameterization by
means of e.g. central controller –fixed functionality –limited number of
devices
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1625 January 2005
AutoAuto--modemode
Configuration-Master
‘‘AA’’
Addressing, communication and transport
Network/Device-Management U
nified kernel
Point to Point
extended
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween media
system modesystem mode
PC based tool
‘‘SS’’ easy modeeasy mode
Log. Tag(& supervised)
Push-Button
Con-troller
‘‘EE’’
RF …IP …
Plug and play Linking of products and parameterization – for loose goods
KNX technology
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1725 January 2005
KNX technology
Addressing, communication and transport
Network/Device-Management U
nified kernel
Point to Point
extended
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween media
AA--2000 mode2000 mode
Configuration-Master
‘‘AA’’system modesystem mode
PC based tool
‘‘SS’’ easy modeeasy mode
Log. Tag(& supervised)
Push-Button
Con-troller
‘‘EE’’
RF …IP …
Linking of different modes via ETS planned
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1825 January 2005
KNX technologyCommon Logo
Unified object defintions / RunUnified object defintions / Run--time Interworkingtime Interworking
RunRun--time Interworkingtime Interworking• Data point types• Functional blocks• Application models
Addressing, communication and transport
Network/Device-Management U
nified kernel
Point to Point
extended
Media Twisted Pair Powerline …Twisted PairTP 0 & 1 PL 110 + PL 132Media couplerMedia couplerbetween mediabetween media
AA--2000 mode2000 mode
Configuration-Master
‘‘AA’’system modesystem mode
PC based tool
‘‘SS’’ easy modeeasy mode
Log. Tag(& supervised)
Push-Button
Con-troller
‘‘EE’’Linking of different modes via ETS planned
RF …IP …
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 1925 January 2005
KNX: current status technical• KNX Specifications Version 1.0 published (May 2002)• IPR Clearance of these specifications positively concluded :
– All patent rights of the members that are according to the specifications necessary for the development of a KNX compatible product, are licensed free of charge to other Konnex members for use in KNX certifiedproducts.
– No other bus association has a similar open and comprehensive system for Home and Building Control
• First KNX (only) devices for Radio Frequency and HVAC Applications submitted for certification
• KNX Specifications Version 1.1– Published in March 2004– clearance process ongoing– Extensions:
• Improvements A-mode• Radio Frequency• KNX via IP (pre-standard version) • USB-interface, distributed Power supply, new Line coupler
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 2025 January 2005
• 06/2000– Konnex Association (at that time still called EHBESA) becomes co-operating partner
of CENELEC– authorizes Konnex to directly submit standard proposals to CENELEC Bureau
Technique (BT)– CENELEC cooperating partners are meant to « represent with a sufficient degree of
representativity a sector of the electotechnical field » : therefore assessment in relevant technical committee appointed by BT of editorial nature
• 12/2001 - Submission to CENELEC Bureau Technique– KNX Twisted pair standard– KNX kernel (LL, NL, TL, AL)– KNX Network Management Procedures
• 05/2002 : Konnex internal publication of version 1.0 of the KNX standard• 11/2002 – Submission to BT of KNX Powerline standard• 12/2002 – Submission of above EN 50090 parts to six months Unique
Acceptance procedure – approval by relevant national committees• 06/2003 – positive vote of national committees - submission for ratification to BT• 12/2003 – ratification received by BT
KNX: from an industry standard to EN
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 2125 January 2005
• Referencing of EN 50090 in CEN– Will replace the ENV 13154-2 specifying the individual KNX legacy
systems• Referencing of EN 50090 in ISO/IEC SC25• Submission of additional standard parts for EN 50090 to
CENELEC BT– Radio Frequency specifications– KNX Interworking Model
• Submission of additional standard parts in CEN– KNX over IP specifications for integration into ENV 13321-2 as
successor to EIBnet IP specifications
Future scheduled standardisation work
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 2225 January 2005
Standards for intelligent buildings: summary• Added value of « intelligence » of buildings can only
be achieved by systems that– Are offered by a large variety of manufacturers,
preferably organised in manufacturer/standardisation associations
– Cover different application domains– Have low threshold for starting contractors and planners– Can be used for smallscale (residential) as well
commercial projects (offices, hotels, airports, …) – ensure multi-vendor and cross-discipline
interoperability– Have system and interworking requirements that are
verified through a solid certification procedure using third party test houses
– Conform to European standards as this increases user’s feeling of security/quality
Konnex Association
The Konnex Certification and AdministrationJoost Demarest
Page No. 2325 January 2005
Thank you for your attention!