intools version 6

Post on 31-Dec-2016

312 Views

Category:

Documents

8 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Process, Power and Marine Division Streamline E&I design schedules

Henk Uiterwijk09-02-2005

© 2004. Intergraph Corporation. All Rights Reserved.

Agenda

SmartPlant Instrumentation SmartPlant Electrical Off-Site Projects AsBuilt / Project environment Intergration Benefits Demonstration

© 2004. Intergraph Corporation. All Rights Reserved.

What is SmartPlant Instrumentation (SPI)?

SPI is a instrumentation design and maintenance package.

SPI is part of the SmartPlant Enterprise. SPI is a Client – Server application SPI is used world-wide by leading Operating

Owners

© 2004. Intergraph Corporation. All Rights Reserved.

SPI Product Highlights

Supporting Oracle and MS SQL Server Import/Export data to/from almost any source Project Environment Generate documents on-the-fly Revision management Part of SmartPlant Enterprise Use of 3rd party suppliers data

Demo

Demo

© 2004. Intergraph Corporation. All Rights Reserved.

What is SmartPlant Electrical?

An easy and flexible tool for electrical engineers to design and maintain electrical

power distribution networks.

© 2004. Intergraph Corporation. All Rights Reserved.

What is SmartPlant Electrical?

• Creation of consistent data, using reference data, and conventions.

• No drawing tool but it creates the main electrical documents from the database.

• Organizing plant / project power consumption and spare capacity.

• Adding automation and efficiency: Create data once, use it many times.

• Data centric engineering tool

© 2004. Intergraph Corporation. All Rights Reserved.

Share data between SPI and SPEL

• Tag Number

• Power Supply

• Wiring Data

• Loop Data

• Panel Data

© 2004. Intergraph Corporation. All Rights Reserved.

Ability to view and embed SPI loop drawings in SPEL schematics (and vice versa, ability to view schematics in SPI)

Retrieve of PLC card termination data into Schematics

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

© 2004. Intergraph Corporation. All Rights Reserved.

Centralize Databases (Off-Site)

CitrixDatabase

Server

Local

Engineering Department

EPC 1

Project B

Country X

EPC 1

Project A

Country X

EPC 2

Project A

Country Y

© 2004. Intergraph Corporation. All Rights Reserved.

Centralized Database (Off-Site)

Minimize ‘on-site’ employees No confusion with As-Built data Consistent Data Entry No Data Hand-over Shorter engineering times Re-use AsBuilt data in a Project. From Project to Asbuilt < 1 Day

© 2004. Intergraph Corporation. All Rights Reserved.

AsBuilt / Project Environment

AsBuilt Site

Project A

Project B

Claimeddata

© 2004. Intergraph Corporation. All Rights Reserved.

Benefits Project Environment

Check work progress All parties using same reference data Correct non-compliancy in early stage No data hand-over No document hand-over Shorter project times

© 2004. Intergraph Corporation. All Rights Reserved.

Why a DCS Interface? – Benefits

Improve engineering performance Reuse of intellectual investment Reduce risks throughout the entire plant life cycle Improved decision support Automatic generation of project documentation Single source of information throughout the entire plant life

cycle SPI providing Validation Rules preventing design mistakes,

such as:– incorrect terminal layout including terminal numbering– incorrect channel type for every terminal– Control on naming of different parts to the DCS configuration (e.g.

panel name, nest / rack name, etc.)– Control over other parameters of the card configuration

© 2004. Intergraph Corporation. All Rights Reserved.

When a DCS Interface? New Greenfield Projects

Exiting Brownfield:- Plant Expansion- Plant Revamp / Modification- DCS Upgrade- Plant Upgrade to

Foundation FieldBus- Process Design Changes- Information As-building- Production Changes and

Simulation Re-runs- Etc, Etc,

© 2004. Intergraph Corporation. All Rights Reserved.

DCS Current Vendor Alliance status Single Direction Interface (SPI >> DeltaV) available since V6.0 Bi-Directional I/F (SPI – DeltaV) dev starting on SPF Adaptors soon... Successfully proto-types of AMS – SPI interface using SPI - API

Bi-Directional I/F (SPI – CS3000) available since V7.0 Continue improve the interface with tight cooperation with Yokogawa

Bi-Directional I/F (SPI – System 800xA) available (V6.0 / V7.0) = PETI ABB Catalog Manager available from V7.0.2 Note - PETI sold only by ABB

Honeywell standardized on SPI for Global projects EPKS Catalog Manager available from V7.0.2Bidirectional Interface in SPI V8

© 2004. Intergraph Corporation. All Rights Reserved.

EngineeringSP Instrumentation DeltaV Resources Configured

Control System

Select Components

Download Components

Upload DeltaV Configuration

Download DeltaV Configuration Updates (SPI V8.0)DeltaVReconcileFile

DeltaV System

DeltaV Components

SPI

The Interface

© 2004. Intergraph Corporation. All Rights Reserved.

The CS 3000 Interface

© 2004. Intergraph Corporation. All Rights Reserved.

ROI Sample (1)

Process, Power and Marine Division

Integrating the Engineering Enterprise…

top related