Innovative/Alternative Septic System Performance

System Performance and Tracking it with the Carmody

Database

Barnstable County Department of Health and Environment

By The NumbersPermit Breakdown by System Type and Year Permitted

System Type Number Percent

FAST 57 38%

Advantex 27 18%

Septitech 22 15%

Bioclere 14 9%

Waterloo Biofilter 12 8%

Singulair 6 4%

RSF 4 3%

Clivus 2 1%

Amphidrome 1 1%

CERES III 1 1%

Nitrex 1 1%

Puraflo 1 1%

Total 149  

Year Number Percent

2011 0 0%

2010 10 7%

2009 9 6%

2008 7 5%

2007 18 12%

2006 19 13%

2005 21 14%

2004 16 11%

2003 10 7%

2002 12 8%

2001 7 5%

2000 14 9%

Pre-2000 6 5%

Numbers are for the town of Eastham only.

By The NumbersPermit Breakdown by Residency, Permit Type and Installation Status

Permit Type Number Percent

General 71 48%

Provisional 41 28%

Remedial 30 20%

Pilot 5 3%

Status Count Percent

Installed

Yes 125 85.0%

No 8 5.4%

Unknown 14 9.5%

Started Up

Yes 121 82.3%

No 9 6.1%

Unknown 17 11.6%

Numbers are for the town of Eastham only.

Match Count Percent

Site and Mailing Address Match

Yes 39 26%

No 110 74%

Site and Mailing City Match

Yes 52 35%

No 97 65%

Site and Mailing State Match

Yes 108 72%

No 41 28%

Installation StatusResidency

DEP Permit Type

Box-Whisker Diagrams

50%

Probability Density Graph (“Bell Curve”)

Median – Middle Value

Min/Max ValueBox

Whiskers

What are they?

Min/Max Value

25% 25%

0

10

20

30

40

50

60

Box-Whisker DiagramsWhat Can We Use Them For?

A B C D

A – A “Good” System. Box and whiskers are short and compact.

B – A “Bad” System. Results are all over the place. Box and whiskers are stretched out.

C – A “Consistently Bad” System. Compact but well above TN limit (19 mg/l)

D – A “Usually Pretty Good” System. Compact but maybe a couple of high results.

Single Family all Types by Individual System

0

20

40

60

80

100

120

140

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Three or More Samples with Full Nitrogen Series

•75 systems with 3 or more TN samples

•46 of 75 (61%) with median TN <19 mg/l

Single Family all Types by System TypeThree or More Samples with Full Nitrogen Series

0

20

40

60

80

100

120

140

Clivus Advantex Waterloo Biofilter Bioclere Singulair FAST Septitech

System Type

To

tal

Nit

rog

en

(m

g/L

)

0

20

40

60

80

100

120

140

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family FASTThree or More Samples with Full Nitrogen Series

•41 systems with 3 or more TN samples

•27 of 41 (66%) with median TN <19 mg/l

0

10

20

30

40

50

60

70

80

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family BioclereThree or More Samples with Full Nitrogen Series

•7 systems with 3 or more TN samples

•5 of 7 (71%) with median TN <19 mg/l

0

10

20

30

40

50

60

70

Individual Systems

To

tal

Nit

rog

en

(m

g/L

)

Single Family AdvantexThree or More Samples with Full Nitrogen Series

•12 systems with 3 or more TN samples

•10 of 12 (83%) with median TN <19 mg/l

0

10

20

30

40

50

60

70

80

90

100

Individual Systems

To

tal

Nit

rog

en

(m

g/l

)

Single Family SeptitechThree or More Samples with Full Nitrogen Series

20 Hideaway Lane

0

10

20

30

40

50

60

6/16/06 7/12/06 8/30/06 7/18/07 7/24/08 8/29/08 7/28/09 9/2/09 8/26/10

To

tal

Nit

rog

en (

mg

/l)

20 Huckleberry Lane

0

10

20

30

40

50

60

70

80

90

7/27/04 9/15/04 7/27/05 9/2/09 8/26/10

To

tal

Nit

rog

en (

mg

/l)

26 Longstreet Lane

0

10

20

30

40

50

60

70

80

90

8/24/05 7/12/06 7/12/06 8/30/06 7/18/07 8/30/07 7/29/08 9/8/08 9/2/09

To

tal

Nit

rog

en (

mg

/l)

495 Campground Road

0

10

20

30

40

50

60

70

80

7/24/03 9/12/03 7/27/04 9/15/04 7/20/10

To

tal

Nit

rog

en (

mg

/l)

31R Martha Ave

0

10

20

30

40

50

60

70

80

90

8/30/06 7/18/07 8/30/07 7/29/08 7/28/10

To

tal

Nit

rog

en (

mg

/l)

Nitrex System at 15 Dory LaneInfluent versus Effluent Total Nitrogen

0

10

20

30

40

50

60

8/6/07 11/14/07 2/22/08 6/1/08 9/9/08 12/18/08 3/28/09 7/6/09 10/14/09 1/22/10

To

tal

Nit

rog

en

(m

g/l

)

Influent TN Effluent TN

Design Flow = 9,900 gpd40 Houses at Buildout30 Houses currently occupied, with 6 seasonal

Keeping Track of it All…Quickly Identifying Poorly Performing Systems

Sample Reports

Use to obtain a list of the most recent sample exceedances (anything

over 19 mg/l)

Two 25% Exceedances

Use to generate a list of systems with two

samples exceeding 19mg/l by 25% (24mg/l).

One 50% Exceedance

Use to generate a list of systems with one sample

exceeding 19 mg/l by 50% (30 mg/l)

Keeping Track of it All…Sample Reports Messages

25.83 mg/L > 19mg/L(36%) for Total Nitrogen 1 Consecutive 4 Non-Consecutive (25.83,8.54,43.4,29.35,24.1)

Amount of the Exceedance

Exceedance Percentage

Exceeding Parameter

Number of Consecutive Exceedances

Number of Non-Consecutive Exceedances

Results from the Last Five Samples

Keeping Track of it All…Quickly Identifying Poorly Performing Systems

Sample Reports

Use to obtain a list of the most recent sample exceedances (anything

over 19 mg/l)

Two 25% Exceedances

Use to generate a list of systems with two

samples exceeding 19mg/l by 25% (24mg/l).

One 50% Exceedance

Use to generate a list of systems with one sample

exceeding 19 mg/l by 50% (30 mg/l)

Keeping Track of it All…Sample Exceedance Report

List of the last 5 samples

Remove the flag for this system. Will reappear on this list with

another exceedance.

Select the Report Type: 2 over 24mg/l,

1 over 30mg/l or merged report.

Export the current list to MS

EXCEL

Keeping Track of it All…Exporting the Sample Exceedance Report to EXCEL

System ID Home Owner Municipality Sampling History

EASte595FAS

Savage, Joseph595 Steele RoadEastham,MA Eastham

5.28 10/7/201014.25 7/12/201011.23 10/14/200924.37 7/9/200952.1 8/21/2007

EAR06420ADV

Seatoller LLC, Steve Lang4205 State Highway Route 6Eastham,MA Eastham

28.84 3/9/201132.45 2/1/201145 1/5/2011

EATur265FAS

St. Aubin, Lucille and Carol265 Turnip RoadEastham,MA Eastham

24.03 9/27/201024.03 9/27/201013.49 6/26/200920.94 9/17/200819.5 6/25/200743.1 9/27/2006

EATur245FAS

St. Aubin, Lucille and Carol245 Turnip RoadEastham,MA Eastham

34.92 7/8/201016.87 12/10/20082.94 10/23/200829.9 3/4/200883.5 12/21/2007

Town of Eastham Sample Exceedance Report - 3/29/2011

System ID Home Owner Municipality Sampling History Median Average StDev

EASam300Sep

Baughman, James and Amanda300 Samoset RoadEastham,MA Eastham

19.61 8/26/201019.61 8/26/201022.56 7/28/201041.37 8/28/200924.44 7/28/200913.73 8/29/2008 21.085 23.55333 9.453086

EASun093Adv

Bechgaard, Candace93 Sunset AvenueEastham,MA Eastham

26.86 2/2/201115.06 7/27/201017.05 4/26/201027.86 1/28/20104.53 8/27/2009 17.05 18.272 9.569957

EAR06418RSF

Brown, Robert4180 Route 6Eastham,MA Eastham

80.6 11/2/201029.31 7/20/200940.1 6/9/200844.5 10/23/200715.3 10/3/2006 40.1 41.962 24.36052

EACam760FAS

Civita, George760 Campground RoadNorth Eastham,MA North Eastham

130.65 11/21/200877 6/9/200856.7 9/18/200723.9 5/14/200740 10/3/2006 56.7 65.65 41.33676

EABri220Bio

Conlin, Kevin220 Bridge RoadEastham,MA Eastham

20.46 1/5/201137.98 7/19/20106.65 1/8/201035.84 7/13/200921.06 1/2/2009 21.06 24.398 12.81631

Keeping Track of it All…“Cleaned Up” Sample Exceedance Report

• Exceedance reports will be delivered quarterly.

• BOH will decide what action to take, since each BOH will likely have a different policy.

Innovative/Alternative Septic System Performance

System Performance and Tracking it with the Carmody

Database

Barnstable County Department of Health and Environment