IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA1

IntelligentTimeCodeDistributionAmplifierIBU-160i

OperationandMaintenanceManual

P/N:900000152REVA

ForBrandywineCommunicationsproducts

withthefollowingPartNumbers:01900100X

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA2

Safety Warnings

WARNING: This unit contains lethal AC voltages. Disconnect the unit from the AC supply before removing the cover.

WARNING:This unit contains dual power supplies. Isolate BOTH power supplied from AC Power before removing the top cover.

WARNING:The lightning flash with an arrowhead inside of an equilateral triangle is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure. The “dangerous voltage” may be of sufficient magnitude to constitute a risk of electrical shock to people. Do not attempt to repair the unit without first unplugging it.

CAUTION:The exclamation point inside of an equilateral triangle is intended to alert the user to the presence of important operation and maintenance instructions in the user guide. Only qualified personnel should repair this unit. Several board assemblies contain static sensitive devices. Appropriate procedures must be used when handling these board assemblies.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA3

RevisionHistory:Revision DateA 04/22/2016

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA4

TableofContents

1 INTRODUCTION 5

2 UNPACKINGTHEIBU-160I 52.1 INSTALLATION 52.1.1 MOUNTING 52.1.2 POWER 62.1.3 ETHERNET 62.1.4 TIMECODEINPUTS 62.1.5 TIMECODEOUTPUTS 62.1.6 CONSOLEPORT 62.1.7 ALARMOUTPUTPORT 6

3 SETTINGUPTHEIBU-160I 7

4 ACCESSINGTHEIBU-160I’SNETWORKINTERFACE 84.1 ACCESSINGFUNCTIONSONTHEIBU-160I 84.1.1 VIEWINGTHECURRENTSTATUSOFTHEIBU-160ISYSTEM 9

5 CHANGINGTHESETTINGSONTHEIBU-160I 105.1 SELECTINGAREFERENCE 105.1.1 CHANGINGTHEREFERENCESWITCHMODE. 115.2 ADJUSTINGTHEOUTPUTSETTINGS 125.3 CHANGINGTHEIPADDRESS 135.4 CHANGINGSNMPSETTINGS 145.4.1 MONITORINGTHEIBU-160IUSINGSNMP 145.5 CHANGINGTHELOCATIONSETTING 155.6 CHANGINGTHEACCESSPASSWORD 16

6 ALTERNATEACCESS 176.1.1 USERCOMMANDSANDRESPONSES 17

7 SUPPORTINFORMATION 20

8 FRONTPANELVIEW 21

9 REARPANELVIEW 22

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA5

1 IntroductionTheIRIGDistributorUnit(IBU-160i)provides16isolatedmodulatedtimecode

outputsbasedonaselectedinputreference.Thecodeoutputisalwaysthesameastheinput.TheIBU-160iprovidesreferenceselection,isolationandindividualamplitudeadjustment.

TheIBU-160iiscontainedinacompactIUrack-mountchassis.TheIBUacceptstwosetsofinputs,comprisingthereferenceIRIGinputandstatusfromthesource.TheIBUprovidesautomaticchangeovershouldoneoftheon-linesourceinputsfail.Manualsourceselectoverrideisavailableonthefrontpanel,orthroughtheEthernetinterface.

Avarietyofstatusindicatorsarelocatedonthefrontpanelforinstantvisualfeedback,togetherwithmanualcontrolsforsourceselection.

A10/100baseTEthernetinterfaceprovidesfullcontroloverthefunctionalityofthesystem,includingreferenceselectionandoutputamplitude(onaperchannelbasis).

Usercontroloftheunitisviaabuilt-inWebBrowserwithuser-friendlygraphicalinterface,orviaSNMPforsystemapplications.

ApplicationsfortheIBU-160iincludetestranges,satellitecontrolcenters,shipboardtimedistribution,airports,railterminals,andanysystemrequiringhighlyreliabletimecodedistribution.

2 UnpackingtheIBU-160iRemovetheIBU-160fromtheshippingcarton.Thefollowingitemsshouldbeincludedintheshipment:1xIBU-160i2xPowersupplycables1xQuickStartGuide

2.1 Installation

2.1.1 MountingTheIBU-160icanbeinstalledintoa19”rackmountcabineteitherusingrackslidesoronlyusingthefrontpanelflanges.Forstaticapplications,theshortdepthandlightweightoftheIBU-160iensuresthatthefrontpanelisnotstressedwhenonlythefrontpanelisusedforsupport.IftheIBU-160iisinstalledonamobileplatformandmustsurviveshockandvibration,theuseofslidesisrequired.Slidesareinstalledusing10-32UNF-2Bhardware.OptionalRackMountSlides:P/N002000123,SLIDE,RACK,24",21"TRAVEL,85LB

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA6

P/N002000150,SLIDE,RACK,28",27"TRAVEL,80LBOriginalManufacturer:GeneralDevicesChassisTrakTypeC300.

2.1.2 PowerInsertthepowercordoftheIBU-160iintoanelectricalsockettopoweruptheunit.ThePowerLEDindicatorwillilluminategreen.Ifdualredundantpowerisrequired,connectbothpowersourcestoindependentpowersources

2.1.3 EthernetConnectoneendofanEthernetpatchcabletotheIBU-160iEthernetportJ21.ConnecttheotherendoftheEthernetcabletothenetworkwithanEthernethuborswitch.

2.1.4 TimeCodeInputsConnectatimecodeinputsourcestothetimecodeinputconnectorsJ17and/orJ18.ChannelAInputisJ18,andChannelBisJ17.

2.1.5 TimeCodeOutputsConnectthetimecodeoutputsJ1throughJ16tothecoaxialinfrastructure.

2.1.6 ConsolePortConnectaDB-9FcabletoportJ20inordertoenableRS-232accesstotheunit.(Straight,pin3isRXpin2isTX)

2.1.7 AlarmOutputPortConnectaDB-9McabletoportJ19toaccessthealarmoutputport.Pleaseseethefollowingdiagramforthepinoutoftheconnector:

Figure1-Alarmoutputpinout

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA7

3 SettinguptheIBU-160iPoweronthesystembyflippingswitchesSW1andSW2ontherearoftheunittotheonposition.Thesystemwilldisplayitspower-oncycleonthefrontpanel.ThesystemwilluseLEDlampsD7throughD17toindicateeachoctetofthedevice’sIPAddress,NetworkMask,andGatewayaddress.Writethesevaluesdownandkeeptheminasafeplace.TodisplaytheIPaddressagain,thefrontpanelcanberesetbypressingtheRESETswitch(SW2)onthefrontpanel.

Figure2-IBU-160iShowingIPAddress

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA8

4 AccessingtheIBU-160i’sNetworkInterfaceConnecttotheIBU-160ibyenteringtheunit’sIPaddressintotheaddressbarofthewebbrowseronaPC,SmartphoneorTablet.

Figure3-IBU-160iWebPageInterface

UsethedropdownmenutoselectdifferentfunctionsoftheIBU-160itoviewthestatusofthesystemandtoadjustdifferentfunctionsoftheunit.

4.1 AccessingFunctionsontheIBU-160i

ToaccessdifferentfunctionsoftheIBU-160imanagementwebpage,selectthebuttonlabeled“MENU”inthetoplefthandcornerofthewebpage.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA9

4.1.1 ViewingtheCurrentStatusoftheIBU-160isystemFromthe“MENU”button,select“General”fromthestatusmenu.Thisshowsinformationsuchasthecurrentoutputtime,UTCtime,uptime,thecurrentinputreference,thecurrentoutputformat,currentsystemstate,andalarmstatus.

Figure4-IBU-160iStatusPage

OutputTime:ThecurrenttimeofdaybeingdisplayedorbeingoutputbytheIBU-160iUTCTime:ThecurrenttimeofdayfromtheGPSconstellationinUniversalTimeCoordinate(UTC)UpTime:ThelengthoftimethattheIBU-160ihasbeenpoweredonHourMeter:ThisistheaccumulatednumberofoperatinghourssincetheIBU-160iwasfirstbuilt.Reference:ThecurrentreferenceinputbeingusedbytheIBU-160iSystemAlarms:IfthesystemiscurrentlydisplayinganyalarmsOutputUnits:Thecurrentunitthesystemisusing

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA10

5 ChangingtheSettingsontheIBU-160i

Figure5-ReferenceSettingsPage

5.1 SelectingaReference

Fromthemenu,select“Reference”fromthesettingssubmenu.Fromthe“SelectReference”dropdownmenu,selectbetweenreferencesourcesA(J18)orB(J17).

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA11

5.1.1 Changingthereferenceswitchmode.Fromthedropdownlabeled,“SelectReferenceSwitchMode,”selectwhichmodetheunitusestoswitchreferencesintheeventofaproblem.Theavailablemodesarelistedbelow.

• Non-Reversionary: Iftheprimaryreferencesourcefailsorisoutofthreshold,thesystemwillautomaticallyswitchovertothesecondaryreferencesource,andcontinuetousethesecondaryuntilmanuallyswitchedbacktotheprimarysource,orthesecondarysourcefailsandthesystemautomaticallyswitchesbacktotheprimary.

• Reversionary: Thesystemwillswitchtothesecondarysourceautomaticallyiftheprimarysourcefailsorisoutofthreshold,howeveroncetheprimarysourceisrestored,theunitwillimmediatelyswitchback

• ReversionarywithDelay: Thesystemwillautomaticallyswitchtothesecondarysourceintheeventtheprimarysourcefailsorisoutofthreshold.Oncetheprimarysourceisrestored,itwillautomaticallyswitchbackafterwaitingforauser-specifieddelay.Thissettingisusefulforhelpingtheunitdealwithintermittentproblemsonaprimarytimecodesource.

5.1.1.1 Adjustingthereversionarydelay.Thetextbox“ReversionaryDelay”isusedtosetthedelaytimeinsecondsusedwhenthesystemissettothe“ReversionarywithDelay”ReferenceSwitchmode.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA12

5.2 AdjustingtheOutputSettings

Figure6-OutputSettings

Fromthemainmenu,select“Output”fromthesettingssubmenu.ThisletstheuserchangetheOutputlevelsofeachindividualtimecodeoutput.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA13

5.3 ChangingtheIPAddress

Fromthemainmenu,select“IP”fromthesettingssubmenu.Fromhere,theIPAddress,SubnetMask,andGatewayaddressoftheunitcanbeselected.Inaddition,itispossibletoenableDHCP,howeverthisactionisnotrecommended.

Figure7IPAddressSettings

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA14

5.4 ChangingSNMPSettings

Fromthemainmenu,select“SNMP”fromthesettingssubmenu.FromheretheReadCommunity,WriteCommunity,andTrapIPAddresscanbeset.

Figure8-SNMPSettings

5.4.1 MonitoringtheIBU-160iusingSNMPTomonitortheIBU-160iviaSimpleNetworkManagementProtocol(SNMP),downloadaMIBfilefromtheSupportDownloadssectionoftheBrandywineCommunicationswebsite.(http://www.brandywinecomm.com/product-support/downloads)

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA15

5.5 ChangingTheLocationSetting

Fromthemainmenu,select“Location”fromthesettingssubmenu.Thissettingtellstheuserwheretheunitisphysicallylocatedwithinafacility.(e.g.Room102)

Figure9-LocationSettingScreen

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA16

5.6 ChangingTheAccessPasswordFromthemainmenu,select“Password”fromthesettingssubmenu.Fromheretheaccesspasswordfortheunittopreventotherusersfromchangingsettingscanbeset.ThecurrentUsernameandPasswordarerequiredinordertoresettheexistingusernameandpassword.Thefactorydefaultlogincredentialsare:Username:BRANDYWINEPassword:BRANDYWINE

Figure10-PasswordSettings

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA17

6 AlternateAccessIftheunitisinanareawhereitcannotbeaccessedoverthenetwork,butphysicalaccesstothedeviceisstillpossible,theIBU-160icanstillbeaccessedandcontrolledviaRS-232overtheserialport.

6.1.1 UserCommandsandResponses TheIBU-160iSerialport(115200,8,1,1,noparity)providesstatusandsettingdataonrequestfromtheuser.TheusercanobtaininformationfromtheIBU160ibysendingHELPcommandterminatedbyCR.TheIBU160iwilldisplaytheHELPMENUasbelow:

-----------------------------------------------------------------------------------------------IBU160iSystemSetup-(925000120)1.01.05Jul92013SN#36770-HardwareVer:A-----------------------------------------------------------------------------------------------COMMANDDescription----------------------------------------------------------------------------------------------HELP ShowthisscreenIPADDR IPAddress(setto0.0.0.0toenableDHCP)(192.168.1.121)IPMASK IPMask(255.255.255.0)IPGATEWAY IPGateway(192.168.1.1)MACADDR MACAddress(00-21-34-00-02-EB)FACT FactoryResettoDefaultsSettingRESET ResetSystemEnteramenucommand:

TheIBU-160iusercommandsaredescribedinthetablebelow.

COMMAND FUNCTION COMMENTS HELP ShowHelp ShowHelpMenu

Example:HELP<CR>DisplaystheaboveHelpMenu.

IPADDR SetIPAddress SettheIPAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA18

Example:IPADRR<CR>New Setting:192.168.1.121<CR> SetstheIPaddressto192.168.1.121anddisplaystheaboveHelpMenu.ToenableDHCPenterIPaddress0.0.0.0<CR>

IPMASK SetIPMaskAddress

Set/GettheIPMaskAddress(decimalnumber)IP4,IP3,IP2,IP1andStoreintoNVM.Example:IPMASK<CR>New Setting:255.255.255.0<CR> SetsIPMaskanddisplaystheaboveHelpMenu.

IPGATEWAY SetGatewayAddress

Set/GettheGatewayAddress(decimalnumber)Gateway4,Gateway3,Gateway2,Gateway1andStoreintoNVM.ExampleIPGATEWAY<CR>NewSetting:192.168.1.1SetsIPGatewayanddisplaystheaboveHelpMenu.

MACADDR SetMACAddress Set/GettheMaskAddress(decimalnumber)Mask4,Mask3,Mask2,Mask1andStoreintoNVM.Example:MACADDR<CR>New Setting: 00-21-34-00-02-EB<CR>SetsMACaddressanddisplaystheaboveHelpMenu.

FACT RecallFactorydefaults

RecallallfactorydefaultsettingsExample:FACT<CR>

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA19

Areyousureyouwanttocontinue(Y/N)?YResetstofactorydefaultanddisplaystheaboveHelpMenu.

RESET ResettheUnit ResettheUnitExample:RESET<CR>Areyousureyouwanttocontinue(Y/N)?YResetSystemResetstheunitanddisplaystheaboveHelpMenu.

Upgrade Application

UsePIC32BootloaderApplicationprogramtoupgrademainapplicationthroughEthernet.Followthebelowcommands:1. RunthePIC32UBL.exe2. ChecktheEthernetEnablecheckedbox.Make

suretheIPAddress=192.168.254.100.3. Hitthe“LoadHexFile”.Browseto“IBU-

160i.hex”tosendthehexfile.4. Hitthe“Upload”button. 5. Waitfortheprogressionbarstartingbefore

recyclethepowersupplysothattheprogramjumptobootloadersection.Thestatusshoulddisplaythebootloaderfirmwareversionsuchas"V1.1". Table 2

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManual

P/N900000152REVA20

7 TroubleshootingProblem Solution

TheIBU-160iDoesnotpoweron Pleaseensurethatthesystemiscorrectlypluggedintopower,andthatbothpowersuppliesareconnected.

TheIBU-160ipowerson,thelightsflashbriefly,andthennothing.

Thesystemfirmwareisnotproperlyloaded.PleasecontactBrandywineCommunicationsforsupport

TheIBU-160ipowersupcorrectly,butthelightsflasherraticallyonceit’spoweredon.

Thesystemdoesnothaveavalidinputreferencefromeitherinputconnection.Pleasedouble-checktheinputconnectors.

8 SupportInformationAllBrandywineCommunicationsproductscomewithaone-yearwarranty.Iftheunitisstillexhibitingproblemsnotcoveredbytheabovetroubleshootingguide,pleasecontactusfortechnicalsupportatsupport@brandywinecomm.comorcallusat714-755-1050.Ifitbecomesnecessarytoreturntheunittothefactoryforrepairs,pleasecallusat714-755-1050extension113toarrangeanRMA.

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA

21

9 FrontPanelView

IBU-160i

IBU-160iIntelligentTimeCodeDistributionAmplifier–OperationandMaintenanceManualP/N900000152REVA

22

10 RearPanelView

top related