harvey avenue - highway no. 97apps.kelowna.ca/citypage/devapps/dp20-0080 harvey ave...±5202 ±1324...

Post on 28-Mar-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

EXISTING

CARWASH

BUILDING

(±104.0 m² / 1,120 S.F.)

EXISTING

HOLDING

STALL

EXISTING

LANDSCAPE

AREA

EXISTING LANDSCAPE AREA

EXISTING PUMP

EXISTING CANOPY

ABOVE

EXISTING SELF-SERVE

SIGN & BASE

PROPOSED NEW

SIGNAGE LOCATION

EXISTING

1-STOREY

BUILDIpl NG

(307.1 m² / 3,305 S.F.)

EXISTING

TRASH

ENCLOSURE

EXISTING

LANDSCAPE

AREA

EXISTING

UNDERGROUND

FUEL TANKS.

EXISTING

UNDERGROUND

FUEL TANKS.

EXISTING PAINTED

PEDESTRIAN WALKWAY

EX

IS

TIN

G P

RO

PE

RT

Y LIN

E

HARVEY AVENUE - HIGHWAY NO. 97

SP

ALL R

OA

D

EXISTING CONC. SIDEWALK

EX

IS

TIN

G C

ON

C. S

ID

EW

ALK

EXISTING CONC. SIDEWALK

±13024

±25460

92° 05' 55" 86.07 m EXISTING PROPERTY LINE

02° 08' 05" 53.17 m

91° 42' 25" 71.30 m EXISTING PROPERTY LINE

A

R

C

.

=

1

6

.

0

1

m

R

A

D

.

=

2

4

.

0

0

m

EX

IS

TIN

G P

RO

PE

RT

Y LIN

E02° 10' 10" 58.90 m

EXISTING SELF-SERVE

SIGN & BASE

EXISTING ROOF

OUTLINE ABOVE

EXISTING ROOF

OUTLINE ABOVE

11

EXISTING

PARKING

EXISTING

PARKING

10

±8800

±13799

±3200

±7200

TRIPLE O's SIGNAGE

LOCATION

±16262

±16925

±7109

±1974

ARCHITECTURAL DRAWINGS

SHEET NO. SHEET NAME

A100SITE PLAN, KEY PLAN AND DRAWING LIST

A200

FLOOR PLAN, EXTERIOR ELEVATION, SCHEDULE &

PROPOSED ART WORK

SCALE:

2

A100

SITE PLAN

1:200

GENERAL NOTES

SITE PLAN AS RECEIVED FROM PARKLAND

DECEMBER 11, 2019 & PREPARED BY

CHEVRON MARKETING ENGINEERING FOR

BUILDING PERMIT APPLICATION. SITE PLAN

SHALL NOT BE MEASURED/ SCALED FROM.

N

LEGEND

EXISTING DT WINDOW

EXISTING BUILDING ENTRANCE/EXIT

EXISTING LANDSCAPING

EXISTING BUILDING

PROPERTY LINE

EXISTING BARRIER FREE

PARKING SPACE

PROJECT TITLE:

Date DwnDescription

DRAWING TITLE:

DRAWN BY: DRAWING NO:

CHECKED BY:

PROJECT NO:

PRINT DATE: SCALE:10-Feb-20

Date DwnDescription

REVISION

#

#

43036 (CHEVRON)1890 HARVEY AVE.

KELOWNA, BC

SN

AM/SL

43036

1 JSISSUED FOR DEVELOPMENT PERMITJAN. 17, 2020

ISSUE

4711 Yonge St.Suite 800Toronto, ON.M2N 6K8T.416.497.3662info@glsmith.cawww.glsmith.ca

· ALL CONSTRUCTION ACTIVITIES MUST FULLY COMPLY WITH THEPROVINCIAL BUILDING CODE, AS AMENDED, AND TO ALL OTHERAPPLICABLE LAWS.

· ALL DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTYOF THE ARCHITECT AND NO COPY AND/OR REPRODUCTION ISPERMITTED UNLESS A WRITTEN CONSENT HAS BEEN PROVIDED BYTHE ARCHITECT

· I HAVE EXERCISED RESPONSIBLE CONTROL WITH RESPECT TO DESIGNREVIEW ACTIVITIES.

· REVIEW WORK PERTAINS TO COMPLIANCE TO THE PROVINCIALBUILDING CODE FOR ARCHITECTURAL WORK ONLY. DRAWINGS OFOTHER PROFESSIONAL ENGINEERS INCLUDING STRUCTURAL,MECHANICAL, ELECTRICAL AND OTHER PROFESSIONAL DESIGNERSMUST BE REFERENCED ACCORDINGLY.

· DRAWINGS MAY BE USED FOR CONSTRUCTION, ONLY WHENSIGNED AND SEALED BY THE ARCHITECT

· CONTRACTOR CANNOT COMMENCE ANY ONSITE WORK UNLESSALL APPLICABLE BUILDING PERMITS ARE DISPLAYED ON SITE

GENERAL NOTES:

PROFESSIONAL STAMPS:

ON THE RUNCONVERSION

A100

SITE PLAN, KEY PLANAND DRAWING LIST

AS NOTED

SCALE:

1

A100

KEY PLAN

N.T.S.

EXISTING SITE STATISTICS

LEGAL DESCRIPTION

PARCEL IDENTIFIER - 003-851-877

LOT 1, SECTION 20, TP 26, ODYD, PLAN 30767

CIVIC ADDRESS: 1890 HARVEY AVENUE, KELOWNA, B.C.

ZONING: C10 - SERVICE COMMERCIAL

SITE AREA: 5,018.06 m² (54,014 S.F.)

BUILDING AREA:

Q.S.R. - 98.1 m²

SALES AREA - 60.4 m²

STORAGE/OFFICE - 116.1 m²

WASHROOMS - 23.4 m²

SITE COVERAGE:

ALOWABLE, 40% SITE AREA PROVIDED

BUILDING - 298 m²

CANOPY - 201.7 m²

CARWASH - 104.0 m²

TOTAL - 402.0 m²

PARKING REQUIREMENT:

REQUIRED - 10 SPACES

PROVIDED - 21 SPACES (EXISTING)

LOADING ZONE:

REQUIRED - 1 SPACE

PROVIDED - 1 SPACE (EXISTING)

SETBACKS

FRONT YARD: 2m

INTERIOR SIDE YARD: 0m

FLANKING SIDE YARD: 2m

REAR SIDE YARD: 0m

FINISH SCHEDULE

TYPE DESCRIPTIONS REMARKS

SUPPLIED

BY

INSTALLED

BY

ANGLED LINEWORK (TRANSLUCENT)

GC TO PURCHASE THROUGH MAXXIT GC GC

ANGLED LINEWORK (OPAQUE)

GC TO PURCHASE THROUGH MAXXIT GC GC

SE4-1

SE4-2

SIGN AND GRAPHIC SCHEDULE

TYPE DESCRIPTIONS REMARKS

SUPPLIED

BY

INSTALLED

BY

GENERAL NOTES

1. ALL PAINTED SURFACES TO RECEIVE ONE COAT PRIMER AND 2 COATS PAINT.

2. APPLY MIN. OF 2 COATS STAIN AND 3 COATS CLEAR LACQUER FINISH TO ALL STAINED SURFACES, 30% SHEEN.

3. PLASTIC LAMINATE WAINSCOTING JOINTS TO BE CONCEALED BETWEEN BOOTH DIVIDER WALLS.

4. APPLY ALUMINUM SCHLUTER EDGING TO ALL EXPOSED TILE EDGES.

5. CONTRACTOR IS RESPONSIBLE TO PROVIDE 5% - 10% MORE FINISH MATERIAL TO BE LEFT ON SITE AT THE END OF THE PROJECT FOR

FUTURE UPKEEP AND REPAIRS.

EXTERIOR WALL/ PARAPET FINISH

VICWEST CORRUGATED STEEL CLADDING (HORIZONTAL)

COLOUR TO MATCH REGENT GREY

GC GC

EXTERIOR METAL PANELS

MAIN SIGN BACKER - ACM METAL PANEL- COLOUR:

PANTONE P-130C + PEROSMATIC

GC GC

EXTERIOR WALL FINISH STUCCO - WHITE GC GC

EXTERIOR WALL FINISH STUCCO - CHARCOAL GC GC

EXTERIOR FINISH

BENJAMIN MOORE: GREY-CHARCOAL GREY

NOCTURNAL # 2121-10

GC GC

EXTERIOR FINISH

MANUFACTURER: BENJAMIN MOORE PAINTS

TYPE: FLAT LATEX GC GC

AE-2

AE-6

AE-7

PT-09

AE-7P

AE-5

MECH.

ROOM

HWT

WALK IN COOLER

FIRE

PLACE

(7) DOOR WALK IN

COOLER

RAISED PLATFORM:

160MM AFF

RAISED PLATFORM:

160MM AFF

SEATING

AREA

FD

ROOF

HATCH

LADDER

TO ABOVE

FD

METAL

FLOOR

HATCH

STORAGE

AREA

STORAGE

AREA

FCB BAG N

BOX & CO2

CO2

OFFICE

FD

WOMEN'S

WASHROOM

FD

MEN'S

WASHROOM

EXIST.

LOTTO

EXIST.

ICE CREAM

EXIST.

PROPANE-

HP

EXIST

ICE

EXIST

PROPANE-HP

STAFF WRM.

FD

SLIGHTLY

RELOCATED

ATM

NEW

COKE

COOLER

2ft x 60"

2ft x 60"

2ft x 60"

2ft x 54"

3FT or 4FT x 48"

BOOKCASE

NEW

EXTERIOR

MERCHANDISER

NEW

EXTERIOR

MERCHANDISER

NEW

ONE DR

FREEZER

FCBFCB

±4495

±308

0±44

2

±618 ±1199 ±622

±720 ±431 ±1315 ±622

±45

7

±991

±

2

5

5

2

254 ±1058

261

±820

49" CEILING

MOUNTED DIGITAL

SCREEN. REFER TO

PFC SPECS

±2386

1

1

7

5

1

1

0

0

M

I

N

.

1

2

3

0

1

1

0

0

M

I

N

.

1

1

5

0

1

1

0

0

M

I

N

.

1

1

5

2

1

1

0

0

M

I

N

.

11

44

110

0 M

IN

.

1

1

0

0

1

1

0

0

M

I

N

.

1

3

2

1

1

1

0

0

M

I

N

.

111

3

110

0 M

IN

.

32" CEILING MOUNTED

DIGITAL SCREEN.

REFER TO PFC SPECS

EXISTING WASHROOM TO

REMAIN, WALL TO BE

RE-FINISHED, G.C. TO PATCH

& REPAIR FIXTURES AS REQ'D

KENO TV

TRAVEL DISTANCE=17.03m

[17032 mm] TO EXIT

TRAVEL DISTANCE=16.59m

[16591 mm] TO EXIT

NEW FCB WALL

BUILT IN DISPENSER

FOR CUPS, LIDS,

STRAWS

LID DISPENSER WESTERN

REFRIGERATION FMVL-3

+ STRAW DISPENSER

WESTERN REFRIGERATION

FMVS-1

3-'FCB' CUP

DISPENSERS

WESTERN

REFRIGERATION

DISPENSE-RITE

ADV-2

OUTLINE OF

VAULTED CEILING

FOOD PARTNER

(TRIPLE O'S)

PAYPOINT

WARMER

TRAVEL DISTANCE=11.68 m

[11682 mm] TO EXIT

±5132 ±3161 ±15807 ±1535

±15

34

±114

90

±7452±3662±7997±1324±5202

±3

59

±2

805

±36

70

±1

01

4±3

675

±19

00

4308

18

90

16

75

300

0

176

822

11

3201

2389

4591

5252

5864

1078

1921

603

4

3595

11431

7959

5057

171

9

3473

41

32

47

73

EXTERIOR ELEVATIONS WAITING FOR FINAL PB FILE

SIGNAGE

DRIVE-THRU

OVERNIGHT

PAYPOINT

DRIVE-THRUAE-7 AE-7

EQ EQ

C

L SIGNAGE

AE-5

NEW ILLUMINATED LETTERS

REFER TO SIGNAGE SHOP

DRAWINGS BY SIGN COMPANY

63

5

4667

AE-7P

NEW FLASHING.

AE-7P

NEW FLASHING.

AE-7P

AE-7P

AE-7

AE-7

AE-7

PT-09

PT-09

PT-09

INSTALL HARDIE BOARD C/W

ACRYLIC STUCCO FINISH

OVER EXISTING CHEQUERED

TILES

NEW LED ILLUMINATED

GREEN BAND

INSTALL 'GREEN' 3M VINYL

STICKER TO EXISTING

ALUMINUM ACCENT STRIPES

AND REMOVE NEON

LIGHTING

AE-7

AE-7

AE-7

AE-7 SE4-1

INSTALL 'GREEN' 3M VINYL

STICKER TO EXISTING

ALUMINUM ACCENT STRIPES

AND REMOVE NEON

LIGHTING

INSTALL HARDIE BOARD C/W

ACRYLIC STUCCO FINISH

OVER EXISTING CHEQUERED

TILES

NEW LED ILLUMINATED

GREEN BAND

PT-09

PT-09

PT-09

PT-09

PT-09

PAINT EXISTING

COLUMNS TO

MATCH

TRIPLE O'S

SIGNAGE BY SIGN

COMPANY

EXISTING STONE VENEER

FINISH TO REMAIN.

AE-5

AE-7

AE-7

AE-7

AE-7

EXISTING STONE VENEER

FINISH TO REMAIN.

EXISTING STONE VENEER

FINISH TO REMAIN.

INSTALL HARDIE BOARD C/W

ACRYLIC STUCCO FINISH

OVER EXISTING CHEQUERED

TILES & PAINT TO

NEW LED ILLUMINATED

GREEN BAND, COLOUR TO

MATCH

PT-09

AE-7

INSTALL 'GREEN' 3M VINYL

STICKER TO EXISTING

ALUMINUM ACCENT STRIPES

AND REMOVE NEON LIGHTING,

COLOUR TO MATCH

PT-09

AE-7P

INSTALL HARDIE BOARD C/W

ACRYLIC STUCCO FINISH

OVER EXISTING CHEQUERED

TILES

PT-09

NEW LED ILLUMINATED

GREEN BAND, COLOUR TO

MATCH

PT-09

INSTALL 'GREEN' 3M VINYL

STICKER TO EXISTING

ALUMINUM ACCENT

STRIPES AND REMOVE

NEON LIGHTING, COLOUR

TO MATCH

PT-09

PT-09

AE-7

NEW LED ILLUMINATED

GREEN BAND BY

SIGNAGE COMPANY,

COLOUR TO MATCH

PT-09

SIGN PERMIT BY

OTHERS

AE-7

AE-7AE-7

AE-7

AE-7

EXISTING STONE VENEER

FINISH TO REMAIN.

EXISTING STONE VENEER

FINISH TO REMAIN.

AE-7P

PROJECT TITLE:

Date DwnDescription

DRAWING TITLE:

DRAWN BY: DRAWING NO:

CHECKED BY:

PROJECT NO:

PRINT DATE: SCALE:10-Feb-20

Date DwnDescription

REVISION

#

#

43036 (CHEVRON)1890 HARVEY AVE.

KELOWNA, BC

SN

AM/SL

43036

1 JSISSUED FOR DEVELOPMENT PERMITJAN. 17, 2020

ISSUE

4711 Yonge St.Suite 800Toronto, ON.M2N 6K8T.416.497.3662info@glsmith.cawww.glsmith.ca

· ALL CONSTRUCTION ACTIVITIES MUST FULLY COMPLY WITH THEPROVINCIAL BUILDING CODE, AS AMENDED, AND TO ALL OTHERAPPLICABLE LAWS.

· ALL DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTYOF THE ARCHITECT AND NO COPY AND/OR REPRODUCTION ISPERMITTED UNLESS A WRITTEN CONSENT HAS BEEN PROVIDED BYTHE ARCHITECT

· I HAVE EXERCISED RESPONSIBLE CONTROL WITH RESPECT TO DESIGNREVIEW ACTIVITIES.

· REVIEW WORK PERTAINS TO COMPLIANCE TO THE PROVINCIALBUILDING CODE FOR ARCHITECTURAL WORK ONLY. DRAWINGS OFOTHER PROFESSIONAL ENGINEERS INCLUDING STRUCTURAL,MECHANICAL, ELECTRICAL AND OTHER PROFESSIONAL DESIGNERSMUST BE REFERENCED ACCORDINGLY.

· DRAWINGS MAY BE USED FOR CONSTRUCTION, ONLY WHENSIGNED AND SEALED BY THE ARCHITECT

· CONTRACTOR CANNOT COMMENCE ANY ONSITE WORK UNLESSALL APPLICABLE BUILDING PERMITS ARE DISPLAYED ON SITE

GENERAL NOTES:

PROFESSIONAL STAMPS:

ON THE RUNCONVERSION

A200

FLOOR PLAN, EXTERIOR ELEVATIONSSCHEDULE & PROPOSED ART WORK

AS NOTED

SCALE:

1

A200

PROPOSED FLOOR PLAN

1:100

SCALE:

2

A200

PROPOSED FRONT ELEVATION

1:100

SCALE:

3

A200

PROPOSED SIDE ELEVATION

1:100

SCALE:

5

A200

SIDE RENDER CONCEPT

N.T.S.SCALE:

4

A200

C-STORE FRONT RENDER CONCEPT

N.T.S.

AutoCAD SHX Text
DRIVE-
AutoCAD SHX Text
THRU

top related