harvey avenue - highway no. 97apps.kelowna.ca/citypage/devapps/dp20-0080 harvey ave...±5202 ±1324...
Post on 28-Mar-2020
1 Views
Preview:
TRANSCRIPT
EXISTING
CARWASH
BUILDING
(±104.0 m² / 1,120 S.F.)
EXISTING
HOLDING
STALL
EXISTING
LANDSCAPE
AREA
EXISTING LANDSCAPE AREA
EXISTING PUMP
EXISTING CANOPY
ABOVE
EXISTING SELF-SERVE
SIGN & BASE
PROPOSED NEW
SIGNAGE LOCATION
EXISTING
1-STOREY
BUILDIpl NG
(307.1 m² / 3,305 S.F.)
EXISTING
TRASH
ENCLOSURE
EXISTING
LANDSCAPE
AREA
EXISTING
UNDERGROUND
FUEL TANKS.
EXISTING
UNDERGROUND
FUEL TANKS.
EXISTING PAINTED
PEDESTRIAN WALKWAY
EX
IS
TIN
G P
RO
PE
RT
Y LIN
E
HARVEY AVENUE - HIGHWAY NO. 97
SP
ALL R
OA
D
EXISTING CONC. SIDEWALK
EX
IS
TIN
G C
ON
C. S
ID
EW
ALK
EXISTING CONC. SIDEWALK
±13024
±25460
92° 05' 55" 86.07 m EXISTING PROPERTY LINE
02° 08' 05" 53.17 m
91° 42' 25" 71.30 m EXISTING PROPERTY LINE
A
R
C
.
=
1
6
.
0
1
m
R
A
D
.
=
2
4
.
0
0
m
EX
IS
TIN
G P
RO
PE
RT
Y LIN
E02° 10' 10" 58.90 m
EXISTING SELF-SERVE
SIGN & BASE
EXISTING ROOF
OUTLINE ABOVE
EXISTING ROOF
OUTLINE ABOVE
11
EXISTING
PARKING
EXISTING
PARKING
10
±8800
±13799
±3200
±7200
TRIPLE O's SIGNAGE
LOCATION
±16262
±16925
±7109
±1974
ARCHITECTURAL DRAWINGS
SHEET NO. SHEET NAME
A100SITE PLAN, KEY PLAN AND DRAWING LIST
A200
FLOOR PLAN, EXTERIOR ELEVATION, SCHEDULE &
PROPOSED ART WORK
SCALE:
2
A100
SITE PLAN
1:200
GENERAL NOTES
SITE PLAN AS RECEIVED FROM PARKLAND
DECEMBER 11, 2019 & PREPARED BY
CHEVRON MARKETING ENGINEERING FOR
BUILDING PERMIT APPLICATION. SITE PLAN
SHALL NOT BE MEASURED/ SCALED FROM.
N
LEGEND
EXISTING DT WINDOW
EXISTING BUILDING ENTRANCE/EXIT
EXISTING LANDSCAPING
EXISTING BUILDING
PROPERTY LINE
EXISTING BARRIER FREE
PARKING SPACE
PROJECT TITLE:
Date DwnDescription
DRAWING TITLE:
DRAWN BY: DRAWING NO:
CHECKED BY:
PROJECT NO:
PRINT DATE: SCALE:10-Feb-20
Date DwnDescription
REVISION
#
#
43036 (CHEVRON)1890 HARVEY AVE.
KELOWNA, BC
SN
AM/SL
43036
1 JSISSUED FOR DEVELOPMENT PERMITJAN. 17, 2020
ISSUE
4711 Yonge St.Suite 800Toronto, ON.M2N 6K8T.416.497.3662info@glsmith.cawww.glsmith.ca
· ALL CONSTRUCTION ACTIVITIES MUST FULLY COMPLY WITH THEPROVINCIAL BUILDING CODE, AS AMENDED, AND TO ALL OTHERAPPLICABLE LAWS.
· ALL DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTYOF THE ARCHITECT AND NO COPY AND/OR REPRODUCTION ISPERMITTED UNLESS A WRITTEN CONSENT HAS BEEN PROVIDED BYTHE ARCHITECT
· I HAVE EXERCISED RESPONSIBLE CONTROL WITH RESPECT TO DESIGNREVIEW ACTIVITIES.
· REVIEW WORK PERTAINS TO COMPLIANCE TO THE PROVINCIALBUILDING CODE FOR ARCHITECTURAL WORK ONLY. DRAWINGS OFOTHER PROFESSIONAL ENGINEERS INCLUDING STRUCTURAL,MECHANICAL, ELECTRICAL AND OTHER PROFESSIONAL DESIGNERSMUST BE REFERENCED ACCORDINGLY.
· DRAWINGS MAY BE USED FOR CONSTRUCTION, ONLY WHENSIGNED AND SEALED BY THE ARCHITECT
· CONTRACTOR CANNOT COMMENCE ANY ONSITE WORK UNLESSALL APPLICABLE BUILDING PERMITS ARE DISPLAYED ON SITE
GENERAL NOTES:
PROFESSIONAL STAMPS:
ON THE RUNCONVERSION
A100
SITE PLAN, KEY PLANAND DRAWING LIST
AS NOTED
SCALE:
1
A100
KEY PLAN
N.T.S.
EXISTING SITE STATISTICS
LEGAL DESCRIPTION
PARCEL IDENTIFIER - 003-851-877
LOT 1, SECTION 20, TP 26, ODYD, PLAN 30767
CIVIC ADDRESS: 1890 HARVEY AVENUE, KELOWNA, B.C.
ZONING: C10 - SERVICE COMMERCIAL
SITE AREA: 5,018.06 m² (54,014 S.F.)
BUILDING AREA:
Q.S.R. - 98.1 m²
SALES AREA - 60.4 m²
STORAGE/OFFICE - 116.1 m²
WASHROOMS - 23.4 m²
SITE COVERAGE:
ALOWABLE, 40% SITE AREA PROVIDED
BUILDING - 298 m²
CANOPY - 201.7 m²
CARWASH - 104.0 m²
TOTAL - 402.0 m²
PARKING REQUIREMENT:
REQUIRED - 10 SPACES
PROVIDED - 21 SPACES (EXISTING)
LOADING ZONE:
REQUIRED - 1 SPACE
PROVIDED - 1 SPACE (EXISTING)
SETBACKS
FRONT YARD: 2m
INTERIOR SIDE YARD: 0m
FLANKING SIDE YARD: 2m
REAR SIDE YARD: 0m
FINISH SCHEDULE
TYPE DESCRIPTIONS REMARKS
SUPPLIED
BY
INSTALLED
BY
ANGLED LINEWORK (TRANSLUCENT)
GC TO PURCHASE THROUGH MAXXIT GC GC
ANGLED LINEWORK (OPAQUE)
GC TO PURCHASE THROUGH MAXXIT GC GC
SE4-1
SE4-2
SIGN AND GRAPHIC SCHEDULE
TYPE DESCRIPTIONS REMARKS
SUPPLIED
BY
INSTALLED
BY
GENERAL NOTES
1. ALL PAINTED SURFACES TO RECEIVE ONE COAT PRIMER AND 2 COATS PAINT.
2. APPLY MIN. OF 2 COATS STAIN AND 3 COATS CLEAR LACQUER FINISH TO ALL STAINED SURFACES, 30% SHEEN.
3. PLASTIC LAMINATE WAINSCOTING JOINTS TO BE CONCEALED BETWEEN BOOTH DIVIDER WALLS.
4. APPLY ALUMINUM SCHLUTER EDGING TO ALL EXPOSED TILE EDGES.
5. CONTRACTOR IS RESPONSIBLE TO PROVIDE 5% - 10% MORE FINISH MATERIAL TO BE LEFT ON SITE AT THE END OF THE PROJECT FOR
FUTURE UPKEEP AND REPAIRS.
EXTERIOR WALL/ PARAPET FINISH
VICWEST CORRUGATED STEEL CLADDING (HORIZONTAL)
COLOUR TO MATCH REGENT GREY
GC GC
EXTERIOR METAL PANELS
MAIN SIGN BACKER - ACM METAL PANEL- COLOUR:
PANTONE P-130C + PEROSMATIC
GC GC
EXTERIOR WALL FINISH STUCCO - WHITE GC GC
EXTERIOR WALL FINISH STUCCO - CHARCOAL GC GC
EXTERIOR FINISH
BENJAMIN MOORE: GREY-CHARCOAL GREY
NOCTURNAL # 2121-10
GC GC
EXTERIOR FINISH
MANUFACTURER: BENJAMIN MOORE PAINTS
TYPE: FLAT LATEX GC GC
AE-2
AE-6
AE-7
PT-09
AE-7P
AE-5
MECH.
ROOM
HWT
WALK IN COOLER
FIRE
PLACE
(7) DOOR WALK IN
COOLER
RAISED PLATFORM:
160MM AFF
RAISED PLATFORM:
160MM AFF
SEATING
AREA
FD
ROOF
HATCH
LADDER
TO ABOVE
FD
METAL
FLOOR
HATCH
STORAGE
AREA
STORAGE
AREA
FCB BAG N
BOX & CO2
CO2
OFFICE
FD
WOMEN'S
WASHROOM
FD
MEN'S
WASHROOM
EXIST.
LOTTO
EXIST.
ICE CREAM
EXIST.
PROPANE-
HP
EXIST
ICE
EXIST
PROPANE-HP
STAFF WRM.
FD
SLIGHTLY
RELOCATED
ATM
NEW
COKE
COOLER
2ft x 60"
2ft x 60"
2ft x 60"
2ft x 54"
3FT or 4FT x 48"
BOOKCASE
NEW
EXTERIOR
MERCHANDISER
NEW
EXTERIOR
MERCHANDISER
NEW
ONE DR
FREEZER
FCBFCB
±4495
±308
0±44
2
±618 ±1199 ±622
±720 ±431 ±1315 ±622
±45
7
±991
±
2
5
5
2
254 ±1058
261
±820
49" CEILING
MOUNTED DIGITAL
SCREEN. REFER TO
PFC SPECS
±2386
1
1
7
5
1
1
0
0
M
I
N
.
1
2
3
0
1
1
0
0
M
I
N
.
1
1
5
0
1
1
0
0
M
I
N
.
1
1
5
2
1
1
0
0
M
I
N
.
11
44
110
0 M
IN
.
1
1
0
0
1
1
0
0
M
I
N
.
1
3
2
1
1
1
0
0
M
I
N
.
111
3
110
0 M
IN
.
32" CEILING MOUNTED
DIGITAL SCREEN.
REFER TO PFC SPECS
EXISTING WASHROOM TO
REMAIN, WALL TO BE
RE-FINISHED, G.C. TO PATCH
& REPAIR FIXTURES AS REQ'D
KENO TV
TRAVEL DISTANCE=17.03m
[17032 mm] TO EXIT
TRAVEL DISTANCE=16.59m
[16591 mm] TO EXIT
NEW FCB WALL
BUILT IN DISPENSER
FOR CUPS, LIDS,
STRAWS
LID DISPENSER WESTERN
REFRIGERATION FMVL-3
+ STRAW DISPENSER
WESTERN REFRIGERATION
FMVS-1
3-'FCB' CUP
DISPENSERS
WESTERN
REFRIGERATION
DISPENSE-RITE
ADV-2
OUTLINE OF
VAULTED CEILING
FOOD PARTNER
(TRIPLE O'S)
PAYPOINT
WARMER
TRAVEL DISTANCE=11.68 m
[11682 mm] TO EXIT
±5132 ±3161 ±15807 ±1535
±15
34
±114
90
±7452±3662±7997±1324±5202
±3
59
±2
805
±36
70
±1
01
4±3
675
±19
00
4308
18
90
16
75
300
0
176
822
11
3201
2389
4591
5252
5864
1078
1921
603
4
3595
11431
7959
5057
171
9
3473
41
32
47
73
EXTERIOR ELEVATIONS WAITING FOR FINAL PB FILE
SIGNAGE
DRIVE-THRU
OVERNIGHT
PAYPOINT
DRIVE-THRUAE-7 AE-7
EQ EQ
C
L SIGNAGE
AE-5
NEW ILLUMINATED LETTERS
REFER TO SIGNAGE SHOP
DRAWINGS BY SIGN COMPANY
63
5
4667
AE-7P
NEW FLASHING.
AE-7P
NEW FLASHING.
AE-7P
AE-7P
AE-7
AE-7
AE-7
PT-09
PT-09
PT-09
INSTALL HARDIE BOARD C/W
ACRYLIC STUCCO FINISH
OVER EXISTING CHEQUERED
TILES
NEW LED ILLUMINATED
GREEN BAND
INSTALL 'GREEN' 3M VINYL
STICKER TO EXISTING
ALUMINUM ACCENT STRIPES
AND REMOVE NEON
LIGHTING
AE-7
AE-7
AE-7
AE-7 SE4-1
INSTALL 'GREEN' 3M VINYL
STICKER TO EXISTING
ALUMINUM ACCENT STRIPES
AND REMOVE NEON
LIGHTING
INSTALL HARDIE BOARD C/W
ACRYLIC STUCCO FINISH
OVER EXISTING CHEQUERED
TILES
NEW LED ILLUMINATED
GREEN BAND
PT-09
PT-09
PT-09
PT-09
PT-09
PAINT EXISTING
COLUMNS TO
MATCH
TRIPLE O'S
SIGNAGE BY SIGN
COMPANY
EXISTING STONE VENEER
FINISH TO REMAIN.
AE-5
AE-7
AE-7
AE-7
AE-7
EXISTING STONE VENEER
FINISH TO REMAIN.
EXISTING STONE VENEER
FINISH TO REMAIN.
INSTALL HARDIE BOARD C/W
ACRYLIC STUCCO FINISH
OVER EXISTING CHEQUERED
TILES & PAINT TO
NEW LED ILLUMINATED
GREEN BAND, COLOUR TO
MATCH
PT-09
AE-7
INSTALL 'GREEN' 3M VINYL
STICKER TO EXISTING
ALUMINUM ACCENT STRIPES
AND REMOVE NEON LIGHTING,
COLOUR TO MATCH
PT-09
AE-7P
INSTALL HARDIE BOARD C/W
ACRYLIC STUCCO FINISH
OVER EXISTING CHEQUERED
TILES
PT-09
NEW LED ILLUMINATED
GREEN BAND, COLOUR TO
MATCH
PT-09
INSTALL 'GREEN' 3M VINYL
STICKER TO EXISTING
ALUMINUM ACCENT
STRIPES AND REMOVE
NEON LIGHTING, COLOUR
TO MATCH
PT-09
PT-09
AE-7
NEW LED ILLUMINATED
GREEN BAND BY
SIGNAGE COMPANY,
COLOUR TO MATCH
PT-09
SIGN PERMIT BY
OTHERS
AE-7
AE-7AE-7
AE-7
AE-7
EXISTING STONE VENEER
FINISH TO REMAIN.
EXISTING STONE VENEER
FINISH TO REMAIN.
AE-7P
PROJECT TITLE:
Date DwnDescription
DRAWING TITLE:
DRAWN BY: DRAWING NO:
CHECKED BY:
PROJECT NO:
PRINT DATE: SCALE:10-Feb-20
Date DwnDescription
REVISION
#
#
43036 (CHEVRON)1890 HARVEY AVE.
KELOWNA, BC
SN
AM/SL
43036
1 JSISSUED FOR DEVELOPMENT PERMITJAN. 17, 2020
ISSUE
4711 Yonge St.Suite 800Toronto, ON.M2N 6K8T.416.497.3662info@glsmith.cawww.glsmith.ca
· ALL CONSTRUCTION ACTIVITIES MUST FULLY COMPLY WITH THEPROVINCIAL BUILDING CODE, AS AMENDED, AND TO ALL OTHERAPPLICABLE LAWS.
· ALL DRAWINGS AND SPECIFICATIONS ARE THE EXCLUSIVE PROPERTYOF THE ARCHITECT AND NO COPY AND/OR REPRODUCTION ISPERMITTED UNLESS A WRITTEN CONSENT HAS BEEN PROVIDED BYTHE ARCHITECT
· I HAVE EXERCISED RESPONSIBLE CONTROL WITH RESPECT TO DESIGNREVIEW ACTIVITIES.
· REVIEW WORK PERTAINS TO COMPLIANCE TO THE PROVINCIALBUILDING CODE FOR ARCHITECTURAL WORK ONLY. DRAWINGS OFOTHER PROFESSIONAL ENGINEERS INCLUDING STRUCTURAL,MECHANICAL, ELECTRICAL AND OTHER PROFESSIONAL DESIGNERSMUST BE REFERENCED ACCORDINGLY.
· DRAWINGS MAY BE USED FOR CONSTRUCTION, ONLY WHENSIGNED AND SEALED BY THE ARCHITECT
· CONTRACTOR CANNOT COMMENCE ANY ONSITE WORK UNLESSALL APPLICABLE BUILDING PERMITS ARE DISPLAYED ON SITE
GENERAL NOTES:
PROFESSIONAL STAMPS:
ON THE RUNCONVERSION
A200
FLOOR PLAN, EXTERIOR ELEVATIONSSCHEDULE & PROPOSED ART WORK
AS NOTED
SCALE:
1
A200
PROPOSED FLOOR PLAN
1:100
SCALE:
2
A200
PROPOSED FRONT ELEVATION
1:100
SCALE:
3
A200
PROPOSED SIDE ELEVATION
1:100
SCALE:
5
A200
SIDE RENDER CONCEPT
N.T.S.SCALE:
4
A200
C-STORE FRONT RENDER CONCEPT
N.T.S.
top related