greaves gcrt 175m rotavator (tractor mounted, pto …srfmtti.dacnet.nic.in/test reports upload...

Post on 20-Jul-2020

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Page 1 of 25

व्यावसाययक परीक्षण यरपोर्ट Z सखं्या@ No.: IMP-453/866

COMMERCIAL TEST REPORT माह:@ Month: June, 2018

GREAVES GCRT 175M ROTAVATOR

(Tractor Mounted, PTO Operated)

भारत सरकार Government of India

कृयष एवं यकसान कल्याण मंत्रालय

Ministry of Agriculture and Farmers Welfare

कृयष, सहकायरता एवं यकसान कल्याण यवभाग Department of Agriculture, Cooperation and Farmers Welfare

दयक्षणी के्षत्र कृयष मशीनरी प्रयशक्षण एवं परीक्षण संस्थान Southern Region Farm Machinery Training and Testing Institute

ट्रैक्र्र नगर, गालटयदने्न - 515 731, यिला: अनंतपुर (आं. प्र.) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.)

[An ISO 9001:2015 CERTIFIED INSTITUTE]

Website: http://srfmtti.dacnet.nic.in/

E-mail: fmti-sr@nic.in Tele./FAX: 08551-286441

IMP-

453/866

GREAVES GCRT 175M ROTAVATOR

(Tractor Mounted, PTO Operated) Commercial

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -

ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]

Page 2 of 25

GREAVES GCRT 175M ROTAVATOR

Report No. : IMP-453/866 Month: JUNE Year: 2018

Government of India

Ministry of Agriculture and Farmers Welfare

Department of Agriculture, Cooperation and Farmers Welfare

Southern Region Farm Machinery Training and Testing Institute

Tractor Nagar, Garladinne-515 731, District: Anantapur (A.P.)

[An ISO 9001:2015 CERTIFIED INSTITUTE]

Telephone: 08551-286441 Fax: 08551-286441

Website: http://srfmtti.dacnet.nic.in/ E-mail: fmti-sr@nic.in

Manufacturer

:

M/s. Osaw Udyog,

Village Manglai, P.O. Khuda Kallan,

Jagadhri Road, Ambala,

Haryana - 133 004, India.

Applicant : M/s. Greaves Cotton Ltd.,

Plot No.72, SIPCOT Industrial Complex,

Ranipet – 632 403, Vellore District,

Tamilnadu, India.

IMP-

453/866

GREAVES GCRT 175M ROTAVATOR

(Tractor Mounted, PTO Operated) Commercial

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -

ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]

Page 22 of 25

9. EASE OF OPERATION & ADJUSTMENTS

No difficulty was observed during the operation and adjustment of rotavator.

10. DEFECTS, BREAKDOWNS AND REPAIRS

No defect/breakdown and repair was occurred during entire period of field

& lab tests.

11. SUMMARY OF OBSERVATIONS, COMMENTS AND

RECOMMENDATION

11.1 No ingress of dust and water/mud in primary reduction gear box,

secondary reduction gear box, and rotary axle bearing cap was

observed.

11.2 Provisions for breather cap and oil level dipstick in primary and secondary

gearbox are provided.

11.3 Parking stand & safety device are provided in rotavator.

11.4 The specification of implement hitch is not conforming in full to the IS 4468

(Pt-I):1997.

11.5 Dimensions of PIC yoke is conforming where as PIC is not conforming to IS

4931:1995. This should be looked into for corrective action.

11.6 The hardness of rotor blades at edge and shank portion do not meet, the

requirement of IS 6690:1981. This should be looked into for corrective

action.

11.7 Carbon & Manganese content of rotor blades do not meet the requirement of

IS 6690:1981. This should be looked into for corrective action.

11.8 Most of parameters of labeling plate are declared as per IS requirement.