Gebhardt - Flow measuring device IMV
Fan RLM 56.250Impeller diameter 256 mm
Inlet cone diameter 16-0250
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 77 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : +49 (0) 79 42 1 01-0
Fax : +49 (0) 79 42 1 01-1 70
0
500
1000
1500
2000
2500
3000
3500
4000
4500
0 400 800 1200 1600 2000
Difference pressure at Inlet ∆pDü Pa
Flo
w r
ate
V m
³/h
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
1,1
1,2
Volu
menstr
om
V m
³/s
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.280Impeller diameter 288 mm
Inlet cone diameter 180 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 73 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
0 500 1000 1500 2000 2500 3000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.355Impeller diameter 363 mm
Inlet cone diameter 228 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 105 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
1000
2000
3000
4000
5000
6000
7000
8000
0 500 1000 1500 2000 2500 3000 3500 4000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.400Impeller diameter 406 mm
Inlet cone diameter 257 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 120 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
10000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.450Impeller diameter 455 mm
Inlet cone diameter 289 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 150 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
2000
4000
6000
8000
10000
12000
14000
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.500Impeller diameter 510 mm
Inlet cone diameter 325 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 190 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
2000
4000
6000
8000
10000
12000
14000
16000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.560Impeller diameter 570 mm
Inlet cone diameter 365 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 240 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
20000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.630Impeller diameter 640 mm
Inlet cone diameter 410 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Facor = 300 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
5000
10000
15000
20000
25000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.710Impeller diameter 718 mm
Inlet cone diameter 460 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 385 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
5000
10000
15000
20000
25000
30000
35000
0 1000 2000 3000 4000 5000 6000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.800Impeller diameter 808 mm
Inlet cone diameter 516 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 485 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
5000
10000
15000
20000
25000
30000
35000
40000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.900Impeller diameter 905 mm
Inlet cone diameter 582 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 620 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
10000
20000
30000
40000
50000
60000
0 1000 2000 3000 4000 5000 6000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.1000Impeller diameter 995 mm
Inlet cone diameter 652 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 790 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
10000
20000
30000
40000
50000
60000
70000
0 1000 2000 3000 4000 5000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.1120Impeller diameter 1120 mm
Inlet cone diameter 733 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 1000 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
10000
20000
30000
40000
50000
60000
70000
80000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.1250Impeller diameter 1250 mm
Inlet cone diameter 823 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 1260 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
20000
40000
60000
80000
100000
0 500 1000 1500 2000 2500 3000 3500 4000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
Gebhardt - Flow measuring device IMV
Fan RLM 56.1400Impeller diameter 1400 mm
Inlet cone diameter 908 mm
Remarus -
Diagram for determination of volume
Volume flow depending on difference presure at Inlet cone
Density of the medium ρ = 1,20 kg/m³
K10 - Factor = 1540 m²s/h
Gebhardtstraße 19-25
D-74638 Waldenburg
Tel. : (0 79 42) 1 01-0
Fax : (0 79 42) 1 01-1 70
0
20000
40000
60000
80000
100000
120000
0 500 1000 1500 2000 2500 3000 3500 4000
Difference pressure at Inlet ∆pDü
Flo
w r
ate
V
m3/h
Pa
&V K pDü= ⋅ ⋅10
2
ρ∆
top related