DataNet: Hardware
• 16-bit resolution data logging system
• 2 internal sensors for temperature and humidity direct measurement and recording
• 4 universal inputs for external sensors: PT-100, thermocouple, 0-1V, 0-50mV, 4-20mA, frequency and pulse counter
Data transmission from end-units to the
central computer utilizes innovative
ZigBee wireless telemetry protocol
DataNet: Units and Distances
RCUSB
DL
DL 1
8
DL
DL1
241 16
RP RP
RP RP
1 15 DL
DL 1
24
80m
(10-50m)
800m
(50-400m)80m
(10-50m)
80m
(10-50)
800m
(50-400m)
Maximum 65,000
units in one
network
Distances are for
Line Of SightPractical distances in
brackets ( )
RC
RP
DL
DL
RPDL
DL
RP RP
DL
DLRP
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DLDL DL DL
USB
DataNet: Mesh Network
DataNet: Short Range Repeater (SRR)
• New mode for DNL910 and DNL920:Short Range Repeater (SRR), no need for H/W change,F/W: 40, S/W: 1.1 or later
• Data loggers can operate now as ZigBee repeaters for short range (SRR), reducing network costs and increasing network robustness
• Data loggers in SRR mode must be connected to AC at all times, as with all DNR900 units
• SRR units can connect to 24 data loggers and 16 Repeaters (Repeaters can be DNR900, DNL920 & DNL910 in SRR mode)
DataNet: Short Range Repeater (SRR)
USB
SRR
RC
RP
DL
DL
RPDL
DL
RP RP
DL
DLRP
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DL
DLDL DL DL
DL
DL
800m
(50-400m)
80m
(10-50)
SRR
80m
(10-50m)
80m
(10-50)
80m
(10-50)80m
(10-50)
80m
(10-50m)
80m
(10-50m)
80m
(10-50m)
ZigBee wireless protocol: 2.4GHz license-free frequency RF Band
• DataNet units can also serve as transmission repeaters to neighboring units. Creating a reliable mesh network of up to 65,000 nodes.
Key ZigBee features include:• Reliable transmission, ensuring no data loss
• Transmission range can be constantly expanded by adding nodes
• Minimal costs due to wire-free infrastructure
• Portable units facilitating easy deployment in various environments
DataNet: ZigBee Telemetry Protocol
Internal rechargeable 4.8V NiMH battery
Operating keypads
Worldwide license-free RF band
Wireless data logging with no data loss
Detailed 2-line LCD Screen
4x recording channel inputs
4-20 mA, 0-50mV, 0-1V, PT100 2-wires,
Thermocouple J, K and T, Pulse counter
and Frequency (Input 4 only), User
defined sensors. Outputs: Normal
Open/Close, (input 1 only), 12V Excitation
Internal RH/Temp sensors
Multiple alarms including SMS
Storing up to 60,000 samples
View up to 65,000 network units
for long range monitoring
Neighboring units Back-up,
creating reliable network
DataNet – Key Benefits
• Multiple data display:Numeric, meter, or graph
• On-line collected data retrieval and display in real-time
• Map View displays all loggers’ location with the measured data
• New sensor definition
• Ability to read the defined sensor’s units on the logger’s display
DataNet – Software
• Full calibration of the loggers via the software
• Documentation and filing
• Alarm levels displayed graphically
• Export and import to and from spreadsheets
• Analytical functions, for professional analysis of the collected data
• Manual backup of calibration setting
• Over-the-air firmware update
DataNet – Software (cont.)
• Creates a network automatically
• Selects the least noisy channel
• Self routing correction
• Low power consumption
• Data handshake
DataNet – ZigBee Benefits
DataNet – Software
Real-time data in multiple
displays with full data analysisAlarm level setup with e-mail
&
SMS notifications
Over-the-air firmware
updates and calibrationMap View displaying unit
location and signal path
DataNet – Crossing Alarm Thresholds
S/W alarms:• Data logger changes color to red on Map view• Sensor changes color on sensor view • PC Screen
Data logger alarm:• Unit audio alarm - buzzer• Normally open/close on Port 1
Email to pre-defined contact/group list
SMS to pre-defined contact/group list
DataNet – Products
DataNet
DNR900 DNL910 DNL920 DNL808 DNL810
Wireless
Repeater &
Receiver
Wireless
Internal Temp.
4 x Ext. Sensors
Data Logger
Wireless
Internal Temp. +
RH
4 x Ext. Sensors
Data Logger
Wireless
External NTC
10KΏ
Mini Data
Logger
Wireless
Internal Digital
Temp + RH.
Mini Data
Logger
* DNL808 and DNL810 will be available during Q1/09
DataNet – Internal Temperature Sensor
While charging the DataNet units
(DNL910 & DNL920), battery charging
increases the internal temperature of the
loggers.
As a result the internal temperature sensor can
measure up to 14° Celsius more then the actual
outside temperature
DataNet – Charging Procedure
All units are connected to the AC and batteries are charged fully for 16 hours.
After that period the units will be charged for 1 minute daily.
Maintaining fully charged batteries, without any effect on internal sensors.
DataNet – Calibration
• All sensor inputs of the DataNet logger units are calibrated following manufacture
• A calibration certificate is added to each unit’s box
• External inputs calibrated include:– 0-20 mA– PT-100– TC/J, TC/K, TC/K– 0-1 V, 0-50 mV
DataNet – On-site Calibration
• The Factory Calibration (FC) is stored in the DataNet logger and at the Fourier Facilities
• DataNet loggers can also be calibrated on-site
• Calibration is done via DataNet S/W and parameters are sent by wireless transmission from the PC to the loggers
• Calibration parameters may be saved on the local PC and then reloaded into the logger
DataNet – On-site Calibration (cont.)
• DataNet logger units can be manually calibrated by right-clicking the Logger icon on the Map View
• Before performing logger calibration, the unit must be in a Stop mode
• DataNet employs two different calibration methods: Two points calibration and Offset calibration
DataNet – Calibration Menu Options
The Calibration menu options are:
• Calibration:Opens the main Calibration dialog box
• Save Calibration:Saves the logger’s current calibration settings
• Load Calibration:Loads a previously saved calibration settings
• Reset Calibration:Resets the logger’s calibration settings so that the raw hardware data is obtained, without any software calibration applied to these values
• Restore Factory Calibration Default:Restores the logger’s calibration settings to the factory calibration i.e. the calibration settings it received prior to shipment from Fourier
DL
RCUSB
DataNet – Calibration
FCCL
• Each DataNet logger keeps both: Factory Calibration Parameters (FC) Actual Calibration Parameters (CL)
• Each FC is saved as file at the Fourier facility
• Once out of the Fourier factory CL = FC
• Clients can re-calibrate the loggers’ sensor inputs, making new CL
• The CL file can be saved on and loaded from the local PC
• By doing Reset Calibration the CL = Nil
• If Reset calibration is done in the specific Sensor calibration menu it will clear only the specific sensor’s calibration parameters
top related