fire, safety and environmental cables
Post on 11-Jan-2017
222 Views
Preview:
TRANSCRIPT
ALSECUREFire, safety and environmental cables
Alsecure is the cable you can stake your
reputation on when safety and security
are critical – to maintain circuit integrity
for mains power, lighting, alarms, pumps,
and other essential services when under fire.
Trust Alsecure to keep you safe and secure.
Nexans Olex Alsecure range is highly flexible and can be
handled and installed safely and easily with standard tools
just like normal building cables.
For more information on these products or for information
on Nexans Olex power, industrial and mining products, visit
www.olex.com.au
Trust Alsecure to keep you safe and secure.
Contents
Introduction 2
Alsecure® Envirolex® 4
Building Flat 6
Flexible Single Core 8
Data 10
Alsecure® Premium® INFIT™ 12
Single Core 90ºC 14
Multicore 90ºC 16
Instrumentation (COMING SOON) 20
Technical
Nomenclature and Fire Resistance Cable Rating System 22
Installation Guide 24
The Cable Range 25
1
Sustainable development has become a major concern in
our society in recent years. For the construction industry,
particularly in buildings, sustainable development implies
a built environment which is habitable, safe and healthy.
Nexans Olex recognizes the importance of sustainable
development in the building and construction industry and
opportunities for advancement of cable design and technology.
As a result, Nexans Olex have developed a three tier offering
for its range of environmental, fire and safety cables for the
building and construction industry based on the following
considerations:
Adopting GBCA guidelines on Best Practice PVC, to ensure
this material is used (manufactured and processed) in a
responsible manner throughout our manufacturing plants,
suppliers’ value chain and end of life management.
Halogen free fire retardant products for a safe and healthy
building environment.
Long life cables made from materials with low
environmental impact both during and after service life.
Building a sustainable future with Nexans Olex.
2 |
Building a sustainable future with Nexans Olex.
Electric cables and their use can
contribute towards sustainable
construction because they can
be an important contributor
to energy efficiency, providing
a safe and healthy built
environment and protect people
and equipment in case of
emergency or fire.
Alsecure®
Premium INFIT™
(Ceramifiable)
Alsecure® Envirolex®
PVC Best Practice Manufactured CablesAs defined by GBCA
Fire Resistant Flame RetardantLow Smoke Zero HalogenNo Acid Gas & Hazardous Fume EmissionsMica Free
Medium Fire PerformanceFlame RetardantLow Smoke Zero HalogenReduced Acid Gas & Hazardous Fume EmissionsLead and other Heavy Metal Free
Environmental, fire and safety cables
Nexans Olex complies with GBCA PVC Best Practice Guidelines.
All PVC used in Nexans Olex manufactured cables follows the
guidelines for Best Practice PVC.
Using Nexans Olex manufactured PVC cables can contribute
to your project earning points towards your new building’s
GBCA Green Star rating (PVC Best Practice Audit document
is available upon request).
Extensive range of enhanced performance cables for the
construction industry engineered from low smoke halogen
free materials with improved fire retardant properties
(over standard PVC cables) reduced smoke, acid gas and
hazardous fume generation particularly under fire conditions,
while retaining the excellent mechanical and electrical
properties designed into Nexans Olex cables.
Complete range of high performance fire safety/ fire resistant
cables engineered from materials developed in conjunction
with CSIRO. This unique cable polymeric insulation material
hardens into a protective ceramic shield when exposed to fire,
maintaining circuit integrity and life-saving essential services.
In addition to its unique property, the material has low calorific
value and fire retardant properties with minimal generation of
hazardous smoke and corrosive fume emissions.
3
PVC Best Practice Manufactured Cables
Alsecure® Envirolex®
Alsecure® Premium INFIT® (Ceramifiable®)
For a safer environment, you can breathe easy.Alsecure® Envirolex® cables are an extensive range
of enhanced performance cables for the construction
industry engineered to dramatically reduce
environmental impact, particularly under fire conditions,
while retaining the excellent mechanical and electrical
properties designed into Nexans Olex cables.
Halogenfree
Lowsmoke
ClBr
Fl
4
ALSECURE®
ENVIROLEX®
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Alsecure® Envirolex® Building Flat 6
Alsecure® Envirolex® Flexible 8
Alsecure® Envirolex® Data 10
Alsecure® Envirolex®
Alsecure® Envirolex® cables are an extensive range of enhanced performance cables
for the construction industry engineered to dramatically reduce environmental impact,
particularly under fire conditions, while retaining the excellent mechanical and electrical
properties designed into Nexans Olex cables. Olex uses a variety of inorganically filled
polyolefin based materials to engineer the cables in the Alsecure® Envirolex® range to
meet a wide variety of end users and performance requirements.
Cable types from building wires, flexible, low voltage power, multicore control and data.
Advantages of Alsecure® Envirolex® Cables
Conductor range up to 630mm2 for single core cables
Improved performance in case if fire:
– Flame retardant/self-extinguishing
– Reduced acid, gas and smoke generation
– Non-corrosive
– Reduced toxicity
Halogen free (i.e. no chlorine, bromine etc.)
Lead free
Easy termination and installation requirements
Made in accordance with Australian Standards
Alsecure® Envirolex® cables have been tested according to and comply with the
requirements as specified in AS1660.5.6.
Alsecure® Envirolex® products include readily strippable cables for general construction
purposes as well as the tougher products commonly found in cables with high
performance capability.
Alsecure® Envirolex® materials can also be used as alternatives for all other low voltage
power and control cables (Refer Nexans Olex Handbook for Low Voltage power and
Control cable from pages 8 to 25). Cables are available on request, subject to minimum
production run.
Setting the highest standards
Properties Australian Standards International Standards
Flame Retardant AS/NZS1660.5.6 IEC60332-1
Bunched Retardance AS/NZS1660.5.1 IEC60332-3-2A
Low Smoke AS/NZS1660.5.2 IEC61034-2
Halogen Free AS/NZS1660.5.3 IEC60754-1
Non Corrosive AS/NZS1660.5.4 IEC60754-2
Applications
Get product and technical information wherever you are with the Olex Handbook app. See page 25 for details.
5
Nominal Main Nominal Nominal Earth Nominal Approx. Product conductor conductor insulation sheath conductor overall mass code area type thickness thickness area diameter mm2 mm mm mm2 mm kg/100m 2C+E 1.0 Solid Cu 0.6 0.9 1.0 9.0x4.2 5.7 CTCP02JA002 1.5 Strand Cu 0.6 0.9 1.5 10.0x4.6 7.2 CTCP05JA002 2.5 Solid Cu 0.6 1.0 2.5 11.2x5.0 11.0 CTCP06JA002 2.5 Strand Cu 0.6 1.0 2.5 11.7x5.3 11.1 CTCP07JA002 4.0 Strand Cu 0.7 1.1 2.5 13.4x6.2 15.2 CTCP09JA002 6.0 Strand Cu 0.7 1.1 2.5 14.5x6.8 19.2 CTCP11JA002 10.0 Strand Cu 0.7 1.2 4.0 17.0x7.8 29.8 CTCP13JA002 16.0 Strand Cu 0.7 1.3 6.0 19.7x8.9 43.7 CTCP15JA002 3C+E 1.5 Strand Cu 0.6 0.9 1.5 12.7x4.6 9.4 ETCP05JA003 2.5 Strand Cu 0.6 1.0 2.5 14.9x5.3 14.6 ETCP07JA003
Alsecure® Envirolex® cables have been tested according to and comply with the requirements of the single flame tests specified in AS/NZ1660-5.6. Alsecure® Envirolex® products include readily strippable cables for general construction purposes as well as the tougher products commonly found in cables with higher fire performance capability.
Construction 2 & 3 core + earth flat, 450/750V X-90 (XLPE) insulated,
HFS-90-TP sheathed to AS/NZS 5000.2, copper conductor, 90°C.
Alsecure® Envirolex® Building Flat
6 |
Specifications
Unenclosed Enclosed Buried Underground Three Cond. Spaced Touching Conduit in Unenclosed Unenclosed direct ducts phase size air round & partially & completely voltage or flat surrounded surrounded drop cable by thermal by thermal mV/A.m mm2 insulation insulation
Cu Cu Cu Cu Cu Cu Cu Cu 1.5 20 19 16 15 9 20 20 30 2.5 28 26 24 21 13 29 29 16.4
Unenclosed Enclosed Buried Underground Single Cond. Spaced Touching Conduit in Unenclosed Unenclosed direct ducts phase size air round & partially & completely voltage or flat surrounded surrounded drop cable by thermal by thermal mV/A.m mm2 insulation insulation
Cu Cu Cu Cu Cu Cu Cu Cu 1 18 17 16 14 9 19 19 54.1 1.5 24 22 20 18 11 24 24 34.7 2.5 34 31 28 25 16 34 34 18.9 4 45 42 37 33 21 45 45 11.8 6 57 53 46 42 27 56 56 7.85 10 78 73 63 58 36 75 75 4.68 16 104 97 82 78 49 132 98 2.95
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 7
ALSECURE®
ENVIROLEX®
Enhanced performance cables
Single Phase Current RatingsTwo core XLPE/PVC 90° 0.6/1kV cables. Table of ratings are also applicable to armoured cables.
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Three Phase Current RatingsThree and four core XLPE/PVC 90° 0.6/1kV cables. Table of ratings are also applicable to armoured cables.
Low Smoke
Flame Retardant
Self – Extinguishing
Halogen Free
Lead Free
Low Acidity
Non Corrosive in Fire Situations
No Special Termination or
Installation Requirements
.Applications
Power and Lighting
Nominal Maximum Nominal Approx. Product conductor diameter overall mass code area of wires diameter mm2 mm mm kg/100m 10 0.21 8.5 14 BZHX01AA001 16 0.21 9.8 20 BZHX02AA001 25 0.21 11.3 30 BZHX03AA001 35 0.21 12.6 40 BZHX04AA001 50 0.31 14.2 54 BZHX05AA001 70 0.31 16.2 74 BZHX06AA001 95 0.31 18.3 99 BZHX07AA001 120 0.51 20.7 125 BZHE87AA001 150 0.51 22.6 150 BZHE88AA001 185 0.51 24.6 179 BZHE89AA001 240 0.51 27.7 240 BZHE90AA001 300 0.51 31.0 290 BZHE91AA001 400 0.51 35.4 389 BZHE92AA001 500 0.51 40.0 498 BZHE93AA001 630 0.51 44.0 629 BZHE94AA001
Applications Flexible cable is intended for installations with moving equipment, electric appliances and for building sites. This cable can be installed in open air or buried (with extra mechanical protection).
Construction 110°C: 0.6/1kV cables, flexible, X-110 (XLPE) insulated and HFS-110-TP
sheathed to AS/NZS 5000.1 (Power) and AS/NZS 1995 (Welding, copper conductors,
110°C continuous, LSOH.
Note: Also available in green/yellow earth 10-120mm2
Alsecure® Envirolex® Flexible
8 |
Specifications
Unenclosed Enclosed Buried Underground Single Cond. Spaced Spaced Touching Conduit Partially Completely direct ducts phase size from in air surrounded surrounded voltage surface by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu 10 103 99 81 78 62 40 119 88 97 4.97 16 137 131 107 104 83 53 154 115 127 3.12 25 183 175 143 137 109 72 198 148 163 1.99 35 225 214 176 165 132 88 238 177 195 1.43 50 276 261 215 205 164 – 282 214 236 1.07 70 349 328 272 255 204 – 346 262 288 0.751 95 434 406 339 321 257 – 416 321 352 0.556 120 505 471 394 369 296 – 473 366 400 0.453 150 581 540 454 430 344 – 531 420 448 0.382 185 673 624 527 493 394 – 601 477 517 0.323 240 806 743 630 594 476 – 698 561 600 0.271 300 934 857 730 – – – 789 648 694 0.240 400 1094 998 853 – – – 898 738 790 0.216 500 1278 1155 990 – – – 1018 837 921 0.199 630 1498 1334 1146 – – – 1148 973 1045 0.185
Unenclosed Enclosed Buried Underground Single Cond. Spaced Spaced Touching Conduit Partially Completely direct ducts phase size from in air surrounded surrounded voltage surface by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu 10 99 86 81 71 57 40 77 77 88 4.3 4.3 16 132 114 107 93 74 53 130 99 115 2.7 2.71 25 177 153 143 125 100 72 168 130 148 1.72 1.72 35 218 188 176 151 121 88 201 155 176 1.24 1.25 50 267 230 215 182 146 – 237 184 212 0.924 0.929 70 339 291 272 234 187 – 291 230 259 0.65 0.657 95 422 363 339 285 228 – 348 277 315 0.481 0.491 120 492 422 394 337 269 – 396 322 357 0.392 0.403 150 565 486 453 382 306 – 445 362 400 0.331 0.344 185 656 564 526 449 359 – 503 415 461 0.28 0.296 240 786 674 629 548 439 – 583 492 533 0.235 0.252 300 912 780 727 626 501 – 657 556 617 0.208 0.227 400 1069 910 847 718 575 – 746 631 700 0.187 0.208 500 1248 1053 981 865 692 – 843 736 815 0.172 0.195 630 1462 1217 1132 983 787 – 947 827 920 0.160 0.184
Three Phase Current RatingsThree single core R-HF-110, R-E-110, X-HF-110° cables
ALSECURE®
ENVIROLEX®
Enhanced performance cables
Features and Benefits
110°C
Flame Retardant
No Heavy Metals
No Corrosive Emissions
Low Smoke
Flexible
Halogen Free
Applications
Welding Flex
Switchboard
Mains Power
Flexible Robotic Cable
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 9
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Single Phase Current RatingsTwo single core R-HF-110, R-E-110, X-HF-110° cables
Applications Offering you an alternative to standard PVC sheath cables, a range of LSZH cables for security, data and fire is now available from Nexans Olex.
Alsecure® Envirolex® Data/Comms
10 |
Number of Nominal Nominal Stranding Approximate Maximum Sheath colour Pack sizes Product cores/pairs conductor overall mass for conductor code area diameter cable resistance @20°C mm2 mm2 No./mm kg/100m ohm/km 4 pairs 0.22 5.3 1/0.50 3.2 93.8 Blue 300m reel JCAT5ELSZHA3 4 pairs 0.22 5.3 1/0.50 3.2 93.8 Grey 300m reel JCAT6LSOH
LAN
Number of Nominal Nominal Stranding Approximate Maximum Sheath colour Pack sizes Product cores/pairs conductor overall mass for conductor code area diameter cable resistance @20°C mm2 mm2 No./mm kg/100m ohm/km 2 cores 1.5 5.3 7/0.50 5 13.6 Red 300m reel JRSI502A3LSOH
Number of Nominal Nominal Stranding Approximate Maximum Sheath colour Pack sizes Product cores/pairs conductor overall mass for conductor code area diameter cable resistance @20°C mm2 mm2 No./mm kg/100m ohm/km 6 cores 0.22 5.5 7/0.20 4.7 95.3 Grey 300m box JD6CSLSOH 2 pairs 0.35 4.3 7/0.25 3 55 Grey 300m box JD2PISLSOHB30
Number of Nominal Nominal Stranding Approximate Maximum Sheath colour Pack sizes Product cores/pairs conductor overall mass for conductor code area diameter cable resistance @20°C mm2 mm2 No./mm kg/100m ohm/km N/A 6.2 – 1/0.60 5.5 62 Black 500m reel JBCRG59CCTVLSOH
Number of Nominal Nominal Stranding Approximate Maximum Sheath colour Pack sizes Product cores/pairs conductor overall mass for conductor code area diameter cable resistance @20°C mm2 mm2 No./mm kg/100m ohm/km 4 cores 0.5 4.7 14/0.20 3.4 45.2 White 300m box JSC5WT4LSOHB30 N/A 0.75 3.0x6.0 24/0.20 3.1 26.4 White/blk stripe 500m reel JSF75WTBKLSOH
Unscreened Security
Unscreened Alarm
Screened Data
Coaxial
ALSECURE®
ENVIROLEX®
Enhanced performance cables
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 11
Features and Benefits
Low Smoke
Halogen Free
Flame Retardant
Lead Free
Low Acidity
No Special Termination
or Installation Requirements
Applications
Security System
Access Control
Railway Stations
Hospitals
Cinemas
Shopping and Commercial Centres
Government Buildings/Schools
Airports
Tunnels
Over the past few years there has been an increase in the awareness
and demand for safety within public places, such as, hospitals,
government buildings, airports, tunnels and railway stations etc.
Contractors are now being asked to install cables which, in the
event of fire are non hazardous to the public and the environment.
Nexans Olex has produced a range of LSZH cables which in the
event of a fire, have three main characteristics with safety in mind,
low smoke, low hazardous fumes and low flame propagation.
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Ultimate fire protection.Fire may destroy everything else in its path, but Alsecure®
Ceramifiable® literally gets tougher. Ceramifiable’s insulation layer
hardens into a protective ceramic shield when exposed to fire,
maintaining circuit integrity and life-saving essential services.
Alsecure® Ceramifiable® stands up to fire without mica tape, making
it more flexible and easier to strip then traditional fire rated cables.
12
Alsecure Projects
Brisbane Airport LinkValue: $10 million AUDContract: To supply 1,100kms Alsecure Premium Fire Resistant CablesCable types supplied: 10mm2-630mm2 Single Core, 4mm2-95mm2 Multicore, InstrumentationProject completed: April 2012Application: Tunnel Cabling – (alarms, pumps, fans, essential services)
Bligh Street ProjectValue: $2 million AUDContract: To supply Alsecure Premium Fire Resistant CablesCable types supplied: 10mm2 to 630mm2 Single Core, 2.5mm2 to 95mm2 Multicore Project completed: 2010Application: Mains power for essential services
Next Distribution CentreValue: $600kContract: To supply Alsecure Premium Fire Resistant CablesCable types supplied: 10mm2 to 630mm2 Single Core, 2.5mm2 to 95mm2 MulticoreProject completed: 2012Application: Mains power for essential services
Rolleston Coal ProjectValue: $330kContract: To supply Alsecure Premium Fire Resistant CablesCable types supplied: 300mm2 Single CoreProject completed: 2012Application: Mains power for essential services
ALSECURE®
PREMIUM INFIT™
Alsecure® Premium INFIT™
Single Core Flex 90°C 14
Multicore 90ºC 16
Instrumentation and Data
(COMING SOON) 20
Alsecure Premium INFIT™ – Breakthrough in Fire Safety Cables
Originally developed in conjunction with the CSIRO & Cooperative Research Centre for
Polymers, Alsecure® Premium INFIT™ utilises the latest in polymer composite technology.
Unlike conventional polymers that breakdown in a fire emergency, the INFIT (previously
known as Ceramifiable®) polymer technology transforms from a flexible, plastic covering
into a tough insulating ceramic barrier that preserves circuit integrity (no breaks or short
circuits) of essential/critical services and equipment such as fire alarms, emergency
lighting, pumps, fans and important process safety continue to operate for period
of time.
How does Alsecure® Premium® INFIT™ work?
INFIT™ technology operates by including the components to form a ceramic material
into a polymeric matrix that is the insulation of the cable. These components are able to
form a ceramic when activated by the high temperature of a fire. The aspect that defines
the product is that the transition is seamless, in that the ceramic is forming at the same
time as the polymer is degrading. This means that the insulation shape and size remains
approximately the same before and after a fire.
Features and Benefits
Superior fire performance
Zero hazardous fume emissions
Halogen free
Fire resistant
Superior thermal performance
Environmentally friendly – no mica, lead or toxic materials
High flexibility
Safe, easy to use, terminable and handle
Resistant to mechanical and water impacts
Setting the highest standards
Properties Australian Standards International Standards
Flame Retardant AS/NZS1660.5.6 IEC60332-1
Fire Retardant AS/NZS 3013 WS52W
Circuit Integrity AS/NZS 1660.5.5 IEC60331.11
Flame Retardant AS/NZS 1660.5.1 IEC60332-3
Low Smoke AS/NZS 1660.5.2 IEC61034-2
Halogen Free AS/NZS 1660.5.3 IEC60754-1
Non Corrosive AS/NZS 1660.5.4 IEC60754-2
For more details on the features and benefits, please email us at
olex.marketing@nexans.com
Applications
| 13
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Get product and technical information wherever you are with the Olex Handbook app. See page 25 for details.
Nominal Nominal Nominal Nominal Approx Minimum bending Maximum Product conductor insulation sheath overall mass radius during pulling code cross section thickness thickness cable installation tension area diameter mm2 mm mm mm kg/100m mm kN 10 1.0 1.4 9.5 16 45 0.2 PXKX01AA001 16 1.0 1.4 10.5 22 50 0.3 PXKX02AA001 25 1.2 1.4 12.2 33 60 0.5 PXKX03AA001 35 1.2 1.4 13.4 42 80 0.8 PXKX04AA001 50 1.4 1.4 15.4 59 90 1.1 PXKX05AA001 70 1.4 1.4 17.1 78 105 1.5 PXKX06AA001 95 1.6 1.5 19.4 105 115 2.1 PXKX07AA001 120 1.6 1.5 21.6 128 130 2.6 PXKE87AA001 150 1.8 1.6 23.6 156 140 3.3 PXKE88AA001 185 2.0 1.7 26.1 189 155 4.0 PXKE89AA001 240 2.2 1.8 29.3 249 175 5.2 PXKE90AA001 300 2.4 1.9 32.4 303 195 6.5 PXKE91AA001 400 2.6 2.0 36.3 390 220 8.7 PXKE92AA001 500 2.8 2.1 41.7 508 250 10.9 PXKE93AA001 630 2.8 2.2 45.9 647 275 13.7 PXKE94AA001
Colours – insulation white (natural), outer sheath – red.
Construction 0.6/1 kV, Single Conductor, Stranded Flexible (Class 6 to AS/NZS 1125)
Plain Annealed Copper, INFIT™ Ceramifiable® (HFI-90-TP to AS/NZS 3808) Insulated,
Halogen Free Flame Retardant (HFS-90-TP to AS/NZS 3808) Sheathed Cable to AS/NZS 5000.1,
90°C Maximum Operating Temperature, WS52W Fire Rated to AS/NZS 3013.
14 |
Alsecure® Premium INFIT™
(Ceramifiable) Single Core Flex 90ºC
Applications Suitable for use in power circuits, consumer mains, sub mains including lift sub mains, pumps and essential circuits – 0.6/1KV.
Specifications
Unenclosed Enclosed Buried Underground Single Cond. Spaced Spaced Touching Conduit Partially Completely direct ducts phase size from in air surrounded surrounded voltage surface by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu 10 83 81 64 64 51 32 77 77 86 4.87 16 110 106 85 82 66 43 136 98 110 3.10 25 147 141 114 109 87 57 173 127 142 2.00 35 183 174 141 132 105 71 210 154 171 1.43 50 231 218 178 167 134 – 256 190 212 1.00 70 292 274 225 204 163 – 312 232 257 0.718 95 351 328 271 248 198 – 364 276 299 0.558 120 418 389 322 286 229 – 419 319 350 0.448 150 483 448 373 336 269 – 473 368 395 0.375 185 555 512 428 377 301 – 528 412 450 0.323 240 668 613 515 452 361 – 616 486 523 0.269 300 772 705 594 – – – 693 548 604 0.239 400 933 843 715 – – – 804 650 700 0.211 500 1090 975 830 – – – 906 733 812 0.195 630 1288 1135 969 – – – 1031 860 931 0.181
Unenclosed Enclosed Buried Underground Single Cond. Spaced Spaced Touching Conduit Partially Completely direct ducts phase size from in air surrounded surrounded voltage surface by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu Cu 10 81 69 64 55 44 32 66 66 78 4.22 4.22 16 106 91 85 73 59 43 115 85 99 2.68 2.68 25 142 121 114 94 75 57 146 109 128 1.73 1.74 35 177 151 141 118 94 71 176 134 154 1.24 1.24 50 223 191 178 144 115 – 215 163 191 0.869 0.875 70 283 241 225 183 146 – 261 203 231 0.622 0.630 95 341 290 271 214 171 – 304 237 268 0.483 0.492 120 406 346 322 256 205 – 349 279 313 0.388 0.399 150 470 400 372 291 233 – 394 316 352 0.325 0.338 185 540 459 427 334 267 – 440 357 401 0.280 0.295 240 651 553 514 391 313 – 511 416 465 0.233 0.251 300 752 637 591 458 366 – 575 479 537 0.207 0.227 400 909 764 709 533 426 – 664 554 620 0.183 0.204 500 1062 884 821 630 504 – 746 642 717 0.169 0.192 630 1256 1030 956 719 575 – 846 729 818 0.157 0.181
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 15
Fire Rated – Ceramifiable®
ALSECURE®
PREMIUM INFIT®
Single Phase Current RatingsTwo single core HFI-90-TP, 90° 0.6/1kV cables
Features and Benefits
Easy to Install
No Mica Tape
No Protective Equipment Needed
Fire Resistant
Non Hazardous
No Heavy Metals
No Corrosive Emissions
Low Smoke
Low Calorific Value
Flexible
Applications
Power Circuit
Consumer Mains and Subs Mains
Lift Sub Mains
Pumps
Essential Circuits
Three Phase Current RatingsThree single core HFI-90-TP, 90° 0.6/1kV cables
Corrosionresistant
Operatingtemp 110°C
Highflexibility
Flameretardant
Operatingtemp 110°C
Physicaltoughness
Highflexibility
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Flameretardant
Operatingtemp 90°C
Highflexibility
Flameretardant
Highflexibility
Flameretardant
Electro magneticinterference
Operatingtemp 90°C
Highflexibility
Flameretardant
Chemicalresistance
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
Lowsmoke
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Lowsmoke
Lowsmoke
Lowsmoke
Lowsmoke
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Halogenfree
ClBr
Fl
Corrosionresistant
Corrosionresistant
Corrosionresistant
Fireresistant
Fireresistant
Fireresistant
Chemicalresistance
Chemicalresistance
Chemicalresistance
Chemicalresistance
Fireresistant
Applications Suitable for use in power circuits, consumer mains and sub mains including lift sub mains, pumps and essential circuits – 0.6/1KV.
Construction 0.6/1 kV, Multiple Conductor, Stranded (Class 2 to AS/NZS 1125) Plain Annealed
Copper, INFIT™ Ceramifiable® (HFI-90-TP to AS/NZS 3808) Insulated, Halogen Free Flame Retardant
(HFS-90-TP to AS/NZS 3808) Sheathed Cable to AS/NZS 5000.1, 90°C Maximum Operating
Temperature, WS52W Fire Rated to AS/NZS 3013.
Alsecure® Premium INFIT™
(Ceramifiable) 90ºC Multicore
16 |
Specifications
Number Nominal Nominal Nominal Nominal Approx. Product of conductor insulation sheath overall mass code cores cross section thickness thickness diameter area mm2 mm mm mm kg/100m 2 0.75 1.0 1.8 10.6 14.1 PEKE99AA002* 3 0.75 1.0 1.8 11.1 16.0 PEKE99AA003* 4 0.75 1.0 1.8 12.0 18.6 PEKE99AA004* 3+E 1.5 1.0 1.8 11.9 19.8 PDKP05AA003 4 1.5 1.0 1.8 12.2 20.3 PEKP05AA004 4+E 1.5 1.0 1.8 12.9 23.4 PDKP05AA004 2 2.5 1.0 1.8 11.8 22.8 PEKP07AA002 2+E 2.5 1.0 1.8 12.2 22.4 PDKP07AA002 3 2.5 1.0 1.8 12.4 23.1 PEKP07AA003 3+E 2.5 1.0 1.8 13.2 26.6 PDKP07AA003 4+E 2.5 1.0 1.8 14.3 31.2 PDKP07AA004 2 4.0 1.0 1.8 12.9 27.9 PEKP09AA002 2+E 4.0 1.0 1.8 13.1 27.1 PDKP09AA002 3 4.0 1.0 1.8 13.6 29.5 PEKP09AA003 3+E 4.0 1.0 1.8 14.2 32.7 PDKP09AA003 4+E 4.0 1.0 1.8 15.4 39.8 PDKP09AA004 Colours: 2 Core – red, black
3 Core – red, white, blue 4 Core – red, white, blue, black
*Coming soon.
Unenclosed Enclosed Partially Buried Underground Single Cond. Spaced Touching Conduit surrounded Completely direct ducts phase size in air by thermal surrounded voltage insulation by thermal drop mm2 insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu 1 16 14 13 12 7 16 16 46.8 1.5 20 19 16 15 9 20 20 30 2.5 28 26 24 21 13 29 29 16.4 4 38 35 30 28 18 37 37 10.2
Features and Benefits
Easy to Install
No Mica Tape
No Protective Equipment Needed
Fire Resistant
Non Hazardous
No Heavy Metals
No Corrosive Emissions
Low Smoke
Low Calorific Value
Applications
Power Circuit
Consumer Mains and Subs Mains
Lift Sub Mains
Pumps
Essential Circuits
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 17
Fire Rated – Ceramifiable®
ALSECURE®
PREMIUM INFIT®
Single Phase Current RatingsTwo Core or Two Core and Earth HFI-90-TP, 90° Cables 0.6/1kV
Three Phase Current RatingsThree Core or Three/Four Core and Earth HFI-90-TP, 90° Cables 0.6/1kV
Unenclosed Enclosed Partially Buried Underground Single Cond. Spaced Touching Conduit surrounded Completely direct ducts phase size in air by thermal surrounded voltage insulation by thermal drop mm2 insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu 1 18 17 16 14 9 19 19 54.1 1.5 24 22 20 18 11 24 24 34.7 2.5 34 31 28 25 16 34 34 18.9 4 45 42 37 33 21 45 45 11.8
Operatingtemp 90°C
Lowsmoke
Halogenfree
ClBr
Fl
Corrosionresistant
Fireresistant
Flameretardant
Chemicalresistance
Number Nominal Nominal Nominal Nominal Approx. Product of conductor insulation sheath overall mass code cores cross section thickness thickness diameter area mm2 mm mm mm kg/100m 2+E 6 1.0 1.8 14.3 29 PDTP11AA002 3+E 6 1.0 1.8 15.4 37 PDTP11AA003 4+E 6 1.0 1.8 16.9 45 PDTP11AA004 2+E 10 1.0 1.8 16.0 40 PDTP13AA002 3+E 10 1.0 1.8 17.3 52 PDTP13AA003 4+E 10 1.0 1.8 18.9 65 PDTP13AA004 3+E 16 1.0 1.8 19.4 73 PDTP15AA003 4+E 16 1.0 1.8 21.3 94 PDTP15AA004 3+E 25 1.2 1.8 23.6 108 PDTC17AA003 4+E 25 1.2 1.8 26.3 137 PDTC17AA004 3+E 35 1.2 1.8 24.7 139 PDTC18AA003 4+E 35 1.2 1.8 27.4 176 PDTC18AA004 4+E 50 1.4 2.0 33.2 242 PDTC19AA004 Colours: 2 Core – red, black 3 Core – red, white, blue 4 Core – red, white, blue, black
Applications Suitable for use in power circuits, consumer mains and sub mains including lift sub mains, pumps and essential circuits – 0.6/1KV.
18 |
Specifications
Alsecure® Premium INFIT™
(Ceramifiable) 90ºC Multicore
Construction 0.6/1 kV, Multiple Conductor, Stranded (Class 2 to AS/NZS 1125) Plain Annealed
Copper, INFIT™ Ceramifiable® (HFI-90-TP to AS/NZS 3808) Insulated, Halogen Free Flame Retardant
(HFS-90-TP to AS/NZS 3808) Sheathed Cable to AS/NZS 5000.1, 90°C Maximum Operating
Temperature, WS52W Fire Rated to AS/NZS 3013.
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 19
Fire Rated – Ceramifiable®
ALSECURE®
PREMIUM INFIT®
Features and Benefits
Easy to Install
No Mica Tape
No Protective Equipment Needed
Fire Resistant
Non Hazardous
No Heavy Metals
No Corrosive Emissions
Low Smoke
Low Calorific Value
Applications
Power Circuit
Mains and Subs Mains
Lift Sub Mains
Power to Fire Pumps
Essential Circuits
Unenclosed Enclosed Buried Underground Single Cond. Spaced Touching Conduit Partially Completely direct ducts phase size in air surrounded surrounded voltage by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu 6 48 45 38 36 22 46 46 6.8 10 66 62 53 49 31 63 63 4.05 16 88 83 68 66 41 110 81 2.55 25 119 111 91 89 56 143 107 1.61 35 147 137 114 110 69 172 130 1.17 50 180 168 136 134 - 204 155 0.868
Single Phase Current RatingsTwo Core or Two Core and Earth HFI-90-TP, 90° Cables 0.6/1kV
Three Phase Current RatingsThree Core or Three/Four Core and Earth HFI-90-TP, 90° Cables 0.6/1kV
Unenclosed Enclosed Buried Underground Single Cond. Spaced Touching Conduit Partially Completely direct ducts phase size in air surrounded surrounded voltage by thermal by thermal drop mm2 insulation insulation mV/A.m
Cu Cu Cu Cu Cu Cu Cu Cu 6 57 53 46 42 27 56 56 7.85 10 78 73 63 58 36 75 75 4.68 16 104 97 82 78 49 132 98 2.95 25 140 131 110 105 66 170 128 1.86 35 173 162 132 129 81 205 154 1.35 50 211 197 162 158 - 244 185 1.00
Operatingtemp 90°C
Lowsmoke
Halogenfree
ClBr
Fl
Corrosionresistant
Fireresistant
Flameretardant
Chemicalresistance
Number Nominal Approx. Minimum Maximum Product of diameter mass bending radius pulling code pairs during installation tension mm2 kg/100m mm kN Conductor 0.75mm2
1 7.8 6.6 115 0.06 PBKP03AA001 2 12.2 13.0 185 0.12 PBKP03AA002 4 13.5 20.5 200 0.24 PBKP03AA004 6 16.3 29.3 240 0.36 PBKP03AA006 8 18.6 38.2 280 0.48 PBKP03AA008 10 20.4 46.2 310 0.60 PBKP03AA010 12 22.3 55.0 340 0.72 PBKP03AA012 16 25.5 71.7 380 0.96 PBKP03AA016 20 28.3 88.5 430 1.20 PBKP03AA020 24 30.9 105.2 460 1.40 PBKP03AA024 Conductor 1.5mm2
1 8.4 8.0 125 0.12 PBK184AA001 2 13.2 15.8 200 0.24 PBK184AA002 4 14.7 25.6 220 0.48 PBK184AA004 6 17.6 36.9 270 0.72 PBK184AA006 8 20.2 48.2 300 0.96 PBK184AA008 10 22.4 59.6 340 1.20 PBK184AA010 12 24.5 71.0 370 1.40 PBK184AA012 16 28.0 92.7 420 1.90 PBK184AA016 20 31.1 114.5 470 2.40 PBK184AA020 24 33.9 136.2 500 2.90 PBK184AA024
Colours – insulation natural/black, outer sheath red only.
Individual/Overall Screened and Triple are available upon request. MOQ applies.
Applications Suitable for use in alarms, pumps, fans and instrumentation. Designed for use as instrumentation cables 110V AC/150V DC.
20 |
Specifications
Alsecure® Premium INFIT™
(Ceramifiable) Instrumentation & Data
COMING SOON
Construction 110 V AC / 150 V DC , Multiple Paired Conductor, Stranded Plain Annealed Copper , INFIT™
Ceramifiable® (HFI-90-TP to AS/NZS 3808) Insulated, Overall Screened with a Polyester/Aluminium laminate tape
and Stranded Tinned Annealed Copper Drain Wire, Halogen Free Flame Retardant (HFS-90-TP to AS/NZS 3808)
Sheathed Cable, 90°C Maximum Operating Temperature, WS51W Fire Rated to AS/NZS 3013.
Note: WS51W Fire rating.
Nominal Maximum Conductor Inductive Insulation conductor conductor DC resistance at reactance at resistance at area resistance at 50Hz 50Hz 20°C 20°C mm2 Ohm/km Ohm/km Ohm/km MegOhm/km 0.75 21.2 27 0.119 15 1.5 13.6 17.3 0.111 13
FIRE, SAFETY AND ENVIRONMENTAL CABLES | 21
Fire Rated – Ceramifiable®
ALSECURE®
PREMIUM INFIT®
COMING SOON
Features and Benefits
Easy to Install
No Mica Tape
No Protective Equipment Needed
Fire Resistant
Halogen Free
Non Hazardous
No Heavy Metals
No Corrosive Emissions
Low Smoke
Low Calorific Value
Applications
Pumps and Sprinkler Systems
Fire Alarms
Process Control Safety Systems
Smoke and Gas Detection Systems
Alsecure Premium Ceramifiable Instrumentation & Data
Lowsmoke
Halogenfree
ClBr
Fl
Corrosionresistant
Fireresistant
Flameretardant
Chemicalresistance
AS/NZS 3013:2005 specifies a rating system for wiring code.
Characteristic letters – WS (‘Wiring System’)
Fire protection period – 1 to 5
Rating against mechanical damage – 1 to 5
Circuit integrity subjected to water after a fire – W
Note
Where a value is not yet determined or applicable an
‘x’ is inserted
WS means wiring system
W means water test after fire
Fire Rating
X N/A
1 15 minutes
2 30 minutes
3 60 minutes
4 90 minutes
5 120 minutes
Technical Information
22 |
Sample characteristicsSamples vertically tied on a ladderNumber depending on the non metallic volume per metre of ladder and the targeted categoryMinimum length 3500mm
Test characteristicsAir input 5000 l/min20.5kW burnerDuration 40min (cat A-B) 20min (cat C-D)
RequirementFlame spread ≤ 2.5metres
Fire Tests – Fire Retardancy – Bunched Cable Test – AS/NZS1660.5.1
Nomenclature and Fire Resistance Cable Rating System
Sample characteristicsCompound 0.5 to 1g/test
Test characteristicsFurnace temperature NFC20453 800°C others 900°CDuration NFC20453 20min EN & IEC 30min
Test outputsCorrosivity (pH) and conductivity
RequirementTo water pH ≥ 3.5To water conductivity ≤ 100µ5cm
Acid Corrosivity Test – AS/NZS1660.5.4
Sample characteristicsLength 600mmSample positioned vertically in a standardised cabin
Test characteristicsCalibrated flame 1kWFlame angle 45°/sampleFlame blue tip touching the cableFlame application time 1 to 4min depending on the cable diameter
RequirementTo H1 > 50mmTo H2 < 540mm
Fire Retardant – Single Cable Test – AS/NZS1660.5.6
Sample characteristicsCable length 1.0m
Number External diameter Number of test sample (mm) Cables Bundles D > 40 1 20 < D ≤ 40 2 10 < D ≤ 20 3 5 < D ≤ 10 N1
1 < D ≤ 5 - N2
N1 = 45/D & N2 = 45/3D
Test characteristicsStandardised alcohol fire source below the samples
RequirementCable specification (≥ 80; 70; 60%)
Low Smoke – AS/NZS1660.5.2
Sample characteristicsCable diameter mmMinimum length 1200mm
Test characteristicsFlame temperature 750ºCRing number cable dia ≤ 10 to 5 cable dia ≤ 10 to 5Voltage cable nominal voltageDuration 105min (90min with fire + 15min under voltage)
RequirementFunction continuity ≥ 105min
Circuit Integrity Test – AS/NZS1660.5.5
23
Note: It is the contractor’s responsibility to ensure that Alsecure® Fire Rated cables are installed in accordance with the relevant standards and regulations for fire rated areas. Contact your local Nexans Olex sales office for further guidelines on suitable fixing methods and materials.
The following installation guide details procedures required to maintain the fire performance features of the Alsecure® – FR range.
This guide is intended to cover typical installation situations, however common sense should always be adopted. In all cases it is the contractor’s
responsibility to ensure that the various standards and regulations applicable to the installation are observed.
AS/NZS 3013: 2005 RATED
Fixed direct onto wall/structure
Laid into trays
Tied onto ladders/struts
Suspended onto catenary
Fixing Devices Fixing Distances Fasteners
Building Structures Equally Fire Rated Walls and Structures (2 hours to AS1530.4)
Where Cable Mechanical Rating Where Additional Mechanical Protection Adequate Protection Required
10 x OD(6 x OD)
For emergency lighting, use fire rated junction boxes
within the fire zone.Fire Rated
BarrierFire Rated Barrier
Greaterthan 90°
Lessthan 45°
Max 1000mm Max 500mm
Fire Zone
Max 250mm
45°
90°
WS x 1
WS x 1WS x 2
Steel Catenary must support cable over total span.Anchor points fire rated.
Steel Mesh or Steel Sheet Cover
Steel Cover
Steel Pipe
Under SteelBeam
In Corner Position
WS x 2
*Installation load shall not exceed 50% of manufacturer’s recommended load bearing capacity.
8 No joins or terminations in fire zone.
4 Bends must be supported.
4
Maximum bending radius of 10 x OD based on rigid conductors (Class 2) and 6 x OD based on flexible conductors (Class 6)
4 Double point (WS x 2)
Single point (WS x 1) galvanised saddles*
4 Galvanised steel clips*
4 Stainless steel ties*
8 NO rope/wire/nylon ties
4 Steel percussion bolts*
4 Steel screw & bolt*
4 Steel expansion bolts*
8 NO plastic/nylon/aluminium
Alsecure® Fire Rated Installation Guide
24 |
The Nexans Olex Cable Range
Low voltage power and control cablesBuilding wires
Flats
PVC/PVC SDIs
XLPE/PVC single cores
PVC/PVC circulars
XLPE/PVC multicores
Armoured PVC/PVC circulars
Armoured XLPE/PVC multicores
Multicore control
Armoured multicore control
Neutral screened
Aerial
Varolex® screened VSD/EMC
Fire performance cablesPyrolex™ Ceramifiable® Fire Rated (FR)
– single core ES110
– multicore ES90
Fire Safe (FS) power
Rolling stock
Locomotive
Envirolex®
Instrolex® instrumentation cablesOverall screened
Overall screened armoured
Individual & overall screened
Individual & overall screened armoured
Thermocouple extension wire
Flexible power and control cablesVersolex® – XLPE/TPE
– Power
– Welding
– EMC/VSD
– Submersible
Flexolex® EPR/CPE power
Titanex®
PVC/PVC power
PVC/PVC control
Data & communications cablesDatolex® – Security
– Figure 8
– Category 5e
– Coaxial
Gardolex™ Garden Lighting
Audiolex™ – Speaker
– Coaxial
Fibre – Multi Mode
– Single Mode
Telephone – Internal
– External
Data
Mining cables (flexible) to 33kVReeling and trailing cables
to AS/NZS 1802 and 2802
Feeder cables
Machine cables
Specialised industrial cables Airport lighting cables:
– Primary and secondary cables
Automation cables
Offshore Oil and gas cables
Defence cables – AO 14,000
– VG cables
– Milspec cables
Rolling stock cables
Materials handling cables
Marine cables
Wind turbine cables
HV transmission cablesExtra High Voltage U/G XLPE to 330kV
(joints, terminations, engineering
services, condition monitoring)
Bare overhead conductors– All Aluminium
– All Aluminium alloy 1120
– ACSR
– Steel earth wire and stay wire
(galvanised or aluminium clad)
HV distribution cablesU/G XLPE to 33kV
Paper insulated lead covered to 33kV
Aerial bundled cable XLPE to 33kV
(metallic and non-metallic screened)
Covered Conductor
Single Point Suspension
HV submarine cables11kV to 33kV (EHV also)
XLPE, EPR or PILC insulation
Radial water barrier:
– Al/HDPE, LAS, stainless steel sheath
Mechanical protection:
– Single, double wire armour, HDPE,
hessian served
25
The right cable at your fingertips.
The new Olex Handbook app now available. Search your app store for ‘Olex Handbook’ or scan a QR code.
LOW VOLTAGE INDUSTRIAL HIGH VOLTAGE FIRE RATED DATA/COMMS MINING