Electrical Safety Products

Trelleborg Electrical Safety Products

A safe working environment is important in all industries, but in the electrical generation and supply industry, it is paramount.

Trelleborg specifically compounds its elastomers and tests its products to ensure the highest standard of electrical protection.

Rubber safety products are simple and easy to use. They fold and hang easily and are durable with a long service life.

We are able to manufacture, test and certify products to the following standards;

• AmericanSocietyofTestingandMaterials(ASTM)inbothlow and high voltage

• AustralianandNewZealandstandards(AS/NZS)inlowvoltage

• BritishStandards(BS)inlowvoltage

• InternationalElectrotechnicalCommision(IEC)

AsanISO9001-2000certifiedcompany, we are able to work with you to design and develop special safety products to meet your specific needs.

TRELLEBORG L.V. CABLE JOINTERS MAT•ManufacturedandtestedtoAS/NZS2978-1995(650VACnominalsafeworking)orspecified standard

•Taggedandcertified

•1500x900x6.5mm

•DesignedtoprovideLVprotection for pit joining operations

• Storagebagsavailable

TRELLEBORG L.V. SAFETY MATTING

• ManufacturedandtestedtoAS/NZS2978-1995(650VACnominalsafeworking)orspecified standard

• Tagged&certified

• ClassA-6.5mmthick,1000mmwideandupto10mlong, general purpose

• ClassB-3mmthick,1000mmwideandupto15mlong,suitable for smooth floor surfaces only

• Availableinblack,white*,blue*orred* (*Surchargeforcolour)

• Storagebagsavailable

TRELLEBORG L.V. CABINET DRAPE•Manufacturedandtestedto AS/NZS4202-1994(650vACnominalmaximumuseagevoltage)orspecifiedstandard

•Madetocustomersize(withinlimitations of the specified standard)

•Taggedandcertified

•RobustUVresistantEPDM/Naturalrubber

•Suppliedwitheithermagneticbuttons, holes or velcro

• Colours-Yellow/GreyorBlue

SUBSTATION L.V MAT KIT•SubstationLVMatKitforupto650V.Includesmagneticfasteners for quick attachment to any part of the panel.

•AS4202ClassIIContents:

•4of600x450x2mmduallayer insulating sheet

•2of1200x600x2mmdual layer insulating sheet

•1of1000x1000x3mmground mat

•1of1100x200x300mmRipstopzipperbag

TRELLEBORG CATENARY HARDWARE & CABLE COVER•Designedtocoverpole

connecting hardware and proximatecableofpotentiallyearthed pole sharing systems such as telephone or cable television

• Taggedandcertified

• Reducesriskofaccidentalcontact by live line workers operating nearby

• ManufacturedtoconformtotheappropriateL.V.standard,depending upon customer requirements

•Holes,Velcroand/ormagneticfasteners

• Storagebagsavailable

TRELLEBORG L.V. CROSSARM COVER•ManufacturedandtestedtoAS/NZS4202-1994(650VACnominalsafeworking)orspecified standard

•Taggedandcertified

•Standardsize1200x350drop.Madetoordersizesalsoavailable

•Reinforcedspine

• Availableinblack,yellow/greyor blue

•Holes,Velcroand/ormagneticfasteners

• Storagebagsavailable

TRELLEBORG CABLE WRAP•Usedextensivelyinpower

generation facilities and control rooms to provide temporary cover on test points whenphasinginH.V.motorsor controls

• Bluenaturalrubber/EPDMsupplied/GumRubberin2mmx100mmx1200mmrollswith500mmVelcrostrap

• Acceptancetestedtowithstand15kVinasinglethickness

TRELLEBORG BUS BAR & SWITCH COVERS•Madetocustomer

requirements

•300x300mmandlarger

•TestedtoeitherAS/NZS4202-1994(L.V.),orASTMD1048(H.V.)orotherspecifiedstandard

•Cabletie,peg,buttons,velcrofastened or magnetic buttons

TRELLEBORG L.V. LINE COVER (Double Drop)

• ManufacturedandtestedtoAS/NZS4202-1994(650VACnominalsafeworking)orspecified standard

• Taggedandcertified

• Standardsizesare900,1000and1200mmlongwitheither300,350or400mmdrop

• 2mm(lightweight)or3mm(heavyduty)rubbersheetmoulded&reinforcedtoconform to the line profile

• Suppliedasabasiccoverorwith sponge inserts for greater linegrip(appliesonlyto3mmheavyduty)

• Holes,Velcroand/ormagneticfasteners

• Availableinblack,yellow/greyor blue

• Storagebagsavailable

TRELLEBORG L.V. LINE HOSE•ManufacturedandtestedtoAS/NZS4202-1994(650VACnominalsafeworking)orspecified standard

•TaggedandCertified

•25mm&32mmdiameterbore

•Manufacturedtomaximumlengthof2.5metres

•Availableinblack

•DesignedtobeeasilyplacedonLVoverheadwire

TRELLEBORG U.V. & FLAME RESISTANT CABLE COVERS• ProoftestedtoAS/NZS4202-1994

•ManufacturedfromUV&Flame resistant polymer

•Cuttorequiredlengthonthejob

•Availablein15mmID,10mmIDand10mrolls

•Grey

•Designedtocoverexposedcopperconductors&links

•Remainresilientandflexible

•Specificallydevelopedtoreduce wildlife initiated outages on sub stations and deadfall initiated bush fires

• Prooftestingcertificatesavailable

TRELLEBORG CABLE END COVER•Temporary,re-useableand

durable cable end cover

•Manufacturedfromdurablehighvisibilityblue2mmnaturalrubber

•Sizestosuitcustomersrequirements

•Acceptancetestedtowithstand5kV

TRELLEBORG CABLE PROTECTOR•ManufacturedinUVstable,

abrasion resistant materials

•10mlengths

•Availableinblack,white,yellow and orange

•Designedtoprotectandconceal insulated cables in high volume and heavy traffic areas, including roadways

• Leadsareeasilyinsertedandwork-placesafetyisenhanced

TRELLEBORG STORAGE BAG•Manufacturedindurable

woven polyethylene to suit the followingproducts:

- L.V.SafetyMatting

- H.V.SafetyMatting

- L.V.CableJointersMat

- L.V.LineCover

- L.V.CrossarmCover

- CatenaryHardware&CableCover

TrelleborgBlanketsaremanufacturedtoASTM1048,Type2,Class4,StyleAandfeature a beaded edge with reinforced eyelets.

TrelleborgBlanketsareavailablein3sizes:

560x560mm 915x915mm 1220x1220mm.

They are proudly manufactured in Australia for Australian conditions and are available in orange.

ThespecialblendofEPDM/NaturalRubbergivessuperiorozoneresistance,tensilestrength,andflexibility.

AllTrelleborgBlanketsarefullycompliant and are supplied either, tested and certified, or untested.

They have also been proof tested @40kVacinaccordancewithASTMD-1048-05:Section9.1.

Speciallydesignedcarrybagsareavailable to protect the blankets when not in use.

HV ELECTRICAL INSULATING BLANKETS

ASTM class/Proof Test Volt

Type / Material Size (mm) Colour Weight

4/40kV EPDM/Natural 560x560 Orange 1.7

4/40kV EPDM/Natural 915x915 Orange 4.34

4/40kV EPDM/Natural 1220x1220 Orange 7.5

SLOTTED STYLE HV ELECTRICAL INSULATING BLANKETS TrelleborgSlottedStyleBlanketsaremanufacturedtoASTM1048,Type2,Class4,StyleAandthey feature a beaded edge with reinforced eyelets.

They are produced with a slot to add versatility to the product.

TheseBlanketsarenormallyused for protection over insulators,crossarmsand/orwires.

TrelleborgBlanketsareavailablein3sizes:

•560x560mm •915x915mm •1220x1220mm.

AllTrelleborgBlanketsarefully

compliant and are supplied tagged tested and certified.

They have also been tested @ 40kVacinaccordancewithASTMD-1048-05:Section9.1.

Speciallydesignedcarrybagsareavailable to protect the blankets when not in use.

ASTM class/Proof Test Volt

Type / Material Size (mm) Colour Weight(kg)

4/40kV EPDM/Natural 560x560 Orange 1.7

4/40kV EPDM/Natural 915x915 Orange 4.34

4/40kV EPDM/Natural 1220x1220 Orange 7.5

TRELLEBORG H.V. SAFETY MATTING

• ManufacturedandtestedtoASTMD178-93

• Taggedandcertified

• Class2-6.5mmthick(17kVnominalsafeworking)

• Class3-9.5mmthick(26.5kVnominalsafeworking)

• Class4-12mmthick(36kVnominalsafeworking)

• Maximumof10metreslongand1000mmwide

• Storagebagsavailable

TRELLEBORG H.V. DIAMOND PATTERN U.S. MILSPEC & IEC MATTING• ManufacturedinaccordancewithMIL-DTL-15562G(Navy)31May1996:ClassificationTypeIII

• Max.safeworking:30kV

• FireresistanttoMIL-STD-1623requirement

• Size:915mmx22metresx4.7mm(3ftx25ftx0.147inch).Cuttolengthavailable.

• Colour:Grey(Blueorgreenavailableasspecialorder)

• AlsomeetsIEC61111Class1requirmentsincluding20kVACwithstand test

TRELLEBORG H.V. LINE HOSE•ManufacturedandtestedtoASTMD1050-85class4(36kVnominalsafeworking)

•TaggedandCertified

•Manufacturedtomaximumlengthof5metreswitha35mmbore

•Hosesuppliedinorangeorblack

•Speciallydevelopedcompound allows for long terminstallationinhazardousenvironments

•Easilyplacedlockingsheath

FLAME RESISTANT SUBSTATION TERMINATION COVER•Manufacturedinflameresistant,selfextinguishingelastomer (IEC(V)flammabilitytestmethod)

•UVstable

•Reducesthepossibilityofwildlife or deadfall initiated supply outages or fires

•Easytofit‘knockon’lockingclips

•Australiandesignedandmanufactured

•Prooftestedto19kVflashover

•CompatiblewithTrelleborgUVresistant conductor and cable cover

968506/12

Brisbane Phone+61(7)38667444

Facsimile+61(7)32634912Email:tqr.info@trelleborg.com

www.trelleborg.com.au

Perth Phone+61(8)92566000

Facsimile+61(8)93535990Email:tqr.info@trelleborg.com

www.trelleborg.com.au

Other Trelleborg Products

Elastomeric Bridge Bearings Elastomeric Bearing Pads & Strips

Trelleborg Waterstops & Seals Rail Track Isolation SystemsTESA SBS - Sliding Bearing Strip

Acoustic Vibration Isolation Bearings

top related