KS1000 RT Roof TileOne Panel Eaves to Ridge

Installation Guide

I nsu la ted Pane ls

May 2008

I N S U L AT E D R O O F S Y S T E M S

bFix first panel (P1) with 3 No. mainfasteners per purlin (minimum)subject to wind loadings

aApply bead of 8mm Ø

gun-grade sealant

2

cApply a 6mm Ø approx. bead ofgun-grade sealant (white) at thebase of the side lap for air sealing

1

34

hInstall side lap stitchers every tilemodule positioned near base ofthe step at 325mm centres

gFix second panel (P2) with3 No. main fasteners perpurlin (minimum)

fLower the next panel (P2) into position

pushing in an upwards direction, ensuringthe roof tile module interlocks and the

panels are lined/levelled and square to oneanother. Check that the side laps are tighttogether at the eaves and ridge positions

jFix ridge flashing

iAdd the correct profile filler

applying gun-grade sealant bothtop and bottom. The filler should

be positioned 80 to 100mmbehind the ridge overlap edge to

prevent bird attack

5

P1

P1

Direction of lay

Direction of lay

Push panel in

Push p

anel

up

Direction of lay

P1 P2

dApply a 6mm Ø approx. beadof gun-grade sealant to top ofpanel at the side joint forweather sealing

eApply a 6mm Ø approx. beadof gun-grade sealant up panel

side joint in line with eaves andridge air sealing

Typicalverge detail

Completed Eaves Detail

Completed eavesto ridge assembly

Low profile colour headedstitching screws

325mm

Low profilecolour headed

stitching screws

Low profile headedpanel fastener

This installation guide should be read inconjunction with the ‘project specific’design drawings and method statements.

Although this ‘installation guide’ is deemedto be correct at the time of publication,Kingspan reserve the right to amend theinformation at any time in the future.Installation Guides are available for the fullrange of Kingspan Insulated Roof, Wall andFacade Systems

Please call Kingspan on:UK: +44 (0) 1352 716100Ire: +353 (0) 42 96 98500

Air seal - 8mm Øgun-grade sealant

Air seal - 8mm Øgun-grade sealant

Internal ridge flashing with 150mmoverlap sealed with air seal,

Vapourflex or gun-grade sealant

Air seal - 8mm Øgun-grade sealant

Air seal - 6mm Ø approx.bead of gun-grade sealant

Internal air seal by others

Note: If air sealing line is required with in the building linethis should be the responsibility of the general contractor.

Eaves beam bysteelwork contractor

see item d

see item e

see item c

3 No. main fastenersper purlin (minimum)

Half-round ridge trim

Apply a 6mm Øapprox. bead of gun-grade sealant uppanel side joint in linewith ridge air sealing

Ridge trim inner with150mm overlaps sealed

Ridge trim inner with150mm overlaps sealed

Weather seal between panelswith Vapourflex tape or similar

Gun applied fire rate canisterinsulation, site applied

Gun applied fire rate canisterinsulation, site applied

Stitching screws as required

Add the correct profile filler applyinggun-grade sealant both top andbottom. The filler should be positioned80 to 100mm behind the ridge overlapedge to prevent bird attack

Colour headed rivets or stitchingscrews at 400mm centres

Half round hip trim

Site applied 6mm Øbead of gun-grade

sealant for air sealingIn-situ weathering systemby specialist contractor

Roof tileprofile

removed

Site applied 6mm Ø gun-gradesealant for air sealing

Stitching screws as required

see item i

Air seal - 8mm Øgun-grade sealant

Primary/MainFastener

Fire-rated CanisterInsulation

Secondary/Stitching Screws

Gun-Grade Sealant

Profiled Verge Filler

Hip Reticulated Foam Filler

Profiled Ridge Filler

KS1000 RT Roof Panel

Components

Note: Ensure steel work is suitably lined,levelled and within tolerance.

Panels are manufactured to suit a left toright direction of lay.

Gun-grade sealant type - non-settingbutyl sealant.

Cleader angleprovided by others

see item d

see item e

see item c

Low profile headed stitcher at325 mm centres (every tile)

Hip Ridge Detail

Valley Ridge Detail

Air seal - 8mmbead of gun-grade sealant

Low profile panelfastener

Hip rafter

Gun applied fire rate canisterinsulation, site applied

Cleader angle bysteelwork contractor

Internal valley hip flashingwith 150mm overlap sealed withVapourflex or gun-grade sealant