dcnm-cbcplr cable couplers - bosch security...
Post on 29-May-2018
266 Views
Preview:
TRANSCRIPT
Communications Systems | DCNM-CBCPLR Cable couplers
DCNM-CBCPLR Cable couplers
www.boschsecurity.com
u Provides an easy way to interconnect DICENTIScable assemblies
u Provides an easy way to interconnect DICENTIScables assemblies with non-DICENTIS cable
u Provides an easy way to create a connection fortemporary devices, like a rostrum microphone
u Provides an easy way to use an external powersupply for your devices
The DICENTIS cable coupler enables Technicians toconnect DICENTIS cable assemblies (with one anotheror with standard CAT-E cable) without the need forspecial tools.The cable coupler can be used to:
• Connect two DICENTIS cables so you can easilyincrease cable length.
• Connect two DICENTIS cables, where one is alwayspresent and ends in a “floor pod” and the other cableis only connected when it is required (for example, arostrum microphone which will not always be used).The cable coupler can be fixed with screws to thefloor pod.
• Interconnect DICENTIS cable with standard CAT5-Ecable and power cable so you can comply with localregulations or make use of current availableinfrastructure.
• Interconnect DICENTIS cable with standard CAT5-Ecable and a 48VDC power supply close to the devices.
• Create a circuit to power on a system without theneed of a Multimedia device, a PC running theMeeting application, or Synoptic control.
Functions
• Makes it is easier to adjust cables to the requiredlength when installing rental systems. Offers a meansto create cables for the desired length by justinterconnecting standard cables without the need ofspecial tools.
• Makes it easy to connect “temporary” devices (forexample, a rostrum microphone) to the DICENTISsystem. At the location of the rostrum microphone,the cable coupler is used as the endpoint of the cable(mounted in a floor pod).
• Makes it possible to comply to the most stringentnorms for fixed/installation cable in buildings.Enables you to use standard CAT-5E and power cablefor the part where the norms have to be met, andDICENTIS cable in the conference room.
• Makes it easy to re-use existing infrastructure/networks (for example, if a CAT-5E network is alreadyin place).
• Makes it possible to place a 48 VDC power supply(not part of the Bosch portfolio) close to theparticipant devices.
• Create a circuit to power on a system without theneed of a Multimedia device, a PC running theMeeting application, or Synoptic control. You can setup two cable couplers with a switch that can be usedto power up the system.
Parts included
Quantity Component
6 pcs DCNM‑CBCPLR Cable couplers
Technical specifications
Electrical
Power supply 48 VDC
Nominal current 3 A
Mechanical
Mounting Using two 2.5 mm screws
Dimensions (H x W x D) 23 x 77 x 29 mm(0.90 X 3.03 x 1.14 in)
Weight 0.035 kg (0.077 lb)
Color Jet black (RAL 9005)
Ordering information
DCNM-CBCPLR Cable couplersTo create connections between DICENTIS cableassemblies.Order number DCNM-CBCPLR
2 | DCNM-CBCPLR Cable couplers
Represented by:
Europe, Middle East, Africa: Germany: North America: Asia-Pacific:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284emea.securitysystems@bosch.comemea.boschsecurity.com
Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanywww.boschsecurity.com
Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 9180onlinehelp@us.bosch.comwww.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems11 Bishan Street 21Singapore 573943Phone: +65 6571 2808Fax: +65 6571 2699apr.securitysystems@bosch.comwww.boschsecurity.asia
© Bosch Security Systems 2017 | Data subject to change without notice25838620043 | en, V2, 20. Nov 2017
top related