Datalogger DL2Mounting
Connection
Operation
*48003740*
4800
3740
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 2
Table of contents
1. Description of symbols .................................22. Disposal ..........................................................23. Information about the product ...................34. Installation .....................................................44.1 Mounting ........................................................................ 44.2 Connection ................................................................... 45. Operation ......................................................56. Data transfer .................................................57. Display ............................................................57.1 Status LED ..................................................................... 57.2 Fill level of data memory ........................................... 68. Connecting the datalogger ..........................6
Scope of delivery:• DataloggerDL2,readytoplugin,withmainsadapterand
RESOL VBus®-cable• Networkcable,1m• Dowelsandscrews• Screwterminal(forextendingtheRESOLVBus® -cable)
9. Quickguide Configuration ...........................710. Start screen web interface DL2 ...................... 710.1 State ................................................................................ 511. Data ............................................................................... 912. Configuration ........................................................... 912.1 Configuration: General ............................................. 1012.2 Configuration:Network ........................................... 1012.3 Configuration: Time ................................................... 1012.4 Configuration:FirmwareUpdate ........................... 1112.5 Configuration: Remote Access ............................... 1112.6 About DL2 .................................................................. 1113. Source code ................................................................ 11Imprint ...................................................................................... 12
Safety advice
Pleasepayattentiontothefollowingsafetyadviceinordertoavoiddangeranddamagetopeopleandproperty.
Attention should be paid to
- thestatutoryprovisions forpreventionof industrial accidents,
-thestatutoryprovisionsforenvironmentalprotection,
-theHealthandSafetyatWorkAct1974
-PartPoftheBuildingRegulations2005
- BS7671 Requirements for electrical installations and relevant safety regulations
Subjecttotechnicalchange.Errorsexcepted.
Thismanualcontainsimportantinformationaboutsafeandproperusageofthisproduct.Pleasekeepthismanual forfuture reference.
1. Description of symbols
2. Disposal
WARNING!Warnings are indicated with a warning triangle!
Signalwordsdescribethedangerthatmayoccur,whenitis not avoided.
- Warningmeansthatinjuriesorevendangeroflifecanoccur.
- Disposeofthepackaginginanenvironmentallysoundmanner.
- Disposeofoldappliancesinanenvironmentallysoundmanner.Uponrequestwewilltakebackyouroldappli-ancesboughtfromusandguaranteeenvironmentally-friendlydisposalofthedevices.
3. Information about the product
Proper usage
ThedataloggerDL2mayonlybeusedinconjunctionwithcon-trollerswithVBus®outputinordertologandaccessdataincompliancewiththetechnicaldataspecifiedinthismanual.
Improperuseexcludesallliabilityclaims.
CE-Declaration of conformity
Theproductcomplieswith therelevantdirectivesandisthereforelabelledwiththeCEmark.TheDeclarationofConformityisavailableuponrequest,pleasecontactRESOL.
Theseinstructionsareexclusivelyaddressedtoauthorisedskilledpersonnel.
-Onlyqualifiedelectriciansshouldcarryoutelectricalworks.
-Initialinstallationmustbeeffectedbyqualifiedpersonnelnamedbythemanufacturer
© R
ESO
L 08
228
dl2.
mon
en.in
dd
3 |
Thisadditionalmoduleenablestheacquisitionandstorageoflargeamountsofdata(suchasmeasuringandbalanceva-luesofthesolarsystem)overalongperiodoftime.TheDL2canbeconfiguredandread-outwithastandardinternetbrowser via its integrated web interface. For transmission ofthedatastoredintheinternalmemoryoftheDL2toaPC,anSDcardcanbeused.
TheDL2isappropriate forallcontrollerswithRESOLVBus®. It can be connected directly to a PC or router for remoteaccessandthusenablescomfortablesystemmoni-toring for yield monitoring or for diagnostics of faults.
• Visualisationofsystemstates
• Yieldcontrol
• Easyconfigurationbyintegratedwebinterfacefor standard internet browsers
• OptionalSDcard
• Exportfunctionforfurtherdataprocessinginspreadsheet programs
• DirectconnectionofPCorrouterforremoteaccess
Technical data
Housing: Plastic PC-ABS and PMMA
Protection type: IP20/DIN40050
Ambient temperature: 0 ... 40 °CDimensions: Ø130mm, depth45mmMounting: wall mounting
Display: BarLEDformonitoringthememorycapacity,1 illuminatedpush-button for presentation of the SDcard status
Interfaces: VBus® for connection to RESOL controllers. Ethernet (LAN),Auto MDIX 10/100 Base TX
Power supply: Inputvoltageofmainsadapter: 100 ... 240 VRated current: 350 mAInputvoltageofDatalogger: 5V DC ± 5 %Memory: 180 MB internal memory,for logging interval of 5 min. sufficient for:
• 30monthsforasystemswithoneDeltaSol®M,oneHKMandoneWMZmodule
• 60months for a systemwithoneDeltaSol®MandoneHKM
• 120monthsforasystemwithoneDeltaSol® M
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 4
4.1 Mounting
The datalogger is designed for the use as a mobile unit as well as a wall-mounted unit. Please pay atten -tion to the following instructions when using the data logger as a wall mounted unit:
Theunitmustonlybelocatedindryinteriorlocations.Itis not suitable for installation inhazardous locations andshouldnotbeplacedclose toanyelectromagneticfields.Pleasepayattentiontoseparateroutingofsensorcablesand mains cables.
1. Chooseamountingplace2. Drilltwoholes(Ø6mm)nexttoeachotheratadistance
of113mmandinserttheencloseddowels.2. Attach the base by means of the enclosed screws
(4x40mm)(1).
4. Installation WARNING!Always disconnect the device from power supply before opening the housing!
4.2 Connection
(1)
Connect the datalogger (pos.1) to other modules in the following order:
1. Connect the data cable (RESOLVBus®, pos.3) to the RESOLcontroller(pos.4).Extend,ifnecessary,withen-closedscrewterminaland(twisted)two-wirecable.
2. Plugmainsadapter(Pos.2)intothemainssocket.
3. Fordirect connectionof a routerorPC,connect thedataloggertotherouter(pos.7)orPC(pos.8)bymeansofthenetworkcable(enclosed,pos.6).
Router 1
2
3
4
6
7
8
Thepowersupplytothedevicemustbecarriedoutviaanexternalmainsadapterandthesupplyvoltagemustbe100...240V~(50...60Hz).
The DL2 is supplied with connected mains adapter andVBus®-cable.
VBus® connection at terminals: 1 / 2 = VBus®- connection 13 / 4 = VBus®- connection 2
LEDs
SD cardLANsocket
© R
ESO
L 08
228
dl2.
mon
en.in
dd
5 |
off no SD card or no mains voltage
green flashing SD card has been recognised; DL2dataarebeingcopiedtotheSDcard. Do notremovetheSDcard.
green SD card can be removed.
5. Operation
ThestatusLED(integratedintothebutton)visualisestheoperatingstateoftheDL2.
Thedataloggercanbeconfigured,readoutanddeletedviatheintegratedwebinterface.TheDL2isadditionallyequip-pedwithamanualresetbutton.Thefollowingfunctionscanbecarriedoutbypushingthebutton:
• Deleting the internal memory; the settings will not bedeleted.Forthispurpose,pressthebuttonformorethan5butlessthan10seconds.AllLEDswillbeflashing.
• Resettingthedataloggertothefactorysettings.Forthispurpose,pressthebuttonformorethan10seconds.AllLEDswillbeilluminated.Thisresetprocesscantakeseveralminutes.
7. Displays
7.1 Status LED
fill leveldata memory
reset button
Status LED
side view: SD card slot
sideview:LANsocket
FordatatransferfromtheinternalmemoryoftheDL2,an SD card can be used:
1. InserttheSDcardintothecardslot2. ThestatusLEDflashesgreen:Thecardhasbeen recognised and data are being automatically transferred3. Afterdatatransfer,thestatusLEDisilluminated (green),theSDcardcanberemoved
ForfurtherinformationaboutfurtherprocessingseeRESOL ServiceCenter manual
Note:theSDcardisnotusedforincreasingtheinternalmemorycapacity.Itisusedfordatatransferonly.
6. Data transfer
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 6
8. Connecting the datalogger
ThedataloggerisdesignedfordirectconnectiontoaPCviaaLANconnectionorarouterandisusedforremoteaccess.Pleasecarryoutthefollowingsteps:
1. Installthesearchtool: The search tool can either be started from theCD (DL2DiscoverToolSetup.exe) or from theinternet(http://www.resol-dl2.de/discover/) (Confirmthesecurityenquiryaboutthedigitalsignature)
2a.Startingthetoolfromtheinternet: Thedataloggerwillautomaticallybesearchedanddis-playedassoonasitisfoundbythesearchtool
2b.InstallationfromtheCD:
• Start„DL2DiscoverToolSetup.exe“.Thesearchtoolwillbeinstalledunder„Programme\RESOL\DL2Discover-Tool“
• StarttheDL2Discovertool.TheDL2willautomaticallybesearchedanddisplayedassoonasitisfoundbythesearchtool.
• Markthedataloggerfoundbythetoolbyclickingonit
• Clickon„Open“
3. Thestandardwebbrowseropens
• Enterusernameandpassword.Usernameandpasswordare„admin“(factorysetting).
7.2 Fill level of data memory ThefilllevelLEDsvisualisethecurrentfilllevelofthedata-logger,i.e.theinternalmemorycapacityused.
Onebarcorrespondsto10%ofthe internalmemorycapacity:Permanentilluminationmeansthatthememorycapacity is fullyused.FlashingLEDsindicatethelevelatwhichdataarebeingstored.
Example:Whenthe3rdbarfromthebottomisflashing,thecapacityusedislargerthan20%butsmallerthan30%.
Note: WhentheDL2 isused inconjunctionwithaGigabit-Networkdevice(laptop,switch,etc.),problemscanoccurwhentheconnectionisbeingestablished.Inthiscase,werecommendusinga100Mbit-switchbetweenthetwodevices.
© R
ESO
L 08
228
dl2.
mon
en.in
dd
7 |
9. Quickguide Configuration 1.Changeusernameandpassword
2. Adjust date and time
3.Enablefirmwareupdate
4.Changetheremoteaccesspassword
5. Print configuration
TheDL2isnowreadyforuse
10. Start screen of the DL2 Web Interface
navigation bar
language selection
variable main window
• Clickonthetabinthenavigationbarinordertoaccessthedifferentsub-windowsofthewebinterface
10.1 State Thestatewindowconsistsoftwodifferentsub-windows:„General“and„Network“.
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 8
State: General
1: currenttimesettingoftheDL2
1a: timeshifttoGMT(inhours)
2: time since last reset
3: sum of all bytes received since last reset
4: sumofalldatapacketsreceivedsincelastreset
5: numberofpacketsinacommunicationcycle
6: sumofalldataloggedintheinternalmemoryoftheDL2
7: freememorycapacity
8: estimated remaining logging time
1
32
4
1a
678
5
State: Network
ThiswindowshowsthecurrentnetworkconfigurationoftheDL2.
{
© R
ESO
L 08
228
dl2.
mon
en.in
dd
9 |
Data: Data download Selectthedataformatfordatadownload:
• Text(Tabulatorcharacter,Windows): generatesatextfilewhichisoptimisedforfurtherpro-cessinginWindows.Atabulatorcharacterseparatesthedatafromeachother.
• Text(Semicolon,Windows): generatesatextfilewhichisoptimisedforfurtherpro-cessinginWindows.Asemicolonseparatesthedatafromeachother.
• Text(Tabulatorcharacter,Linux): generatesatextfilewhichisoptimisedforfurtherpro-cessinginLinux/MacOSX,etc.Atabulatorcharacterseparatesthedatafromeachother.
• Text(Semicolon,Linux): generatesatextfilewhichisoptimisedforfurtherpro-cessinginLinux/MacOSX,etc.Asemicolonseparatesthedatafromeachother.
• HTMLTable: dataarerepresentedinatableinaHTMLfile
• HTMLList: dataarerepresentedinaHTMLfileasanestedlist.
• Excel: dataareissuedinExcelformatfordirectprocessinginExcel(max.60.000datarecords)
• VBusProtocolData: dataareissuedinafileformatsuitableforfurtherpro-cessingintheRESOLServiceCenterorintheRESOLData Center
Inthissub-window,thedatastoredintheinternalmemoryoftheDL2canberead.
TheDL2webinterfaceprovidesdifferenttabswhicharedescribedinthefollowingsection.
11. Data
Data: Live-Data Thecurrentdataof theconnectedVBus®-devices are displayed,suchas:temperature,pumpspeed,heatquan-tity,etc.Thevalueswillautomaticallybeupdatedevery10seconds.
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 10
12.3 Configuration: Time Intheconfigurationwindow„Time“,carryoutthefollowingsettings:
• Enterthetimezone
• Adjusttheupdateinterval
• Enable/disablethenetworktimesynchronisationfunction
• EnterNTPserveraddress
• Manuallyadjustthetimesettings
Data: Erase Inordertodeletealldata,clickonthe„Yes,eraseallloggeddata“button.
12.2 Configuration: Network In theconfigurationwindow„Network“, thesettingsmentionedbelowhavetobecarriedout.Whentheauto-configurationisnotenabled,allnetworkparametershavetobeenteredmanuallyintothefieldsbelow.
• Enable/disabletheLANautoconfiguration
• InformationsuchasIPaddress,IPnetmask,etc.isindicated.
12. Configuration Inthefollowingsub-windowsofthewebinterface,theset-tingsoftheDL2canbechanged.
• Inordertosavethechanges,clickon„Savechanges“.
The„PrintConfiguration“button:
• Inordertoprintthecurrentconfigurationofthewebinterface,clickon„PrintConfiguration“.
Logging modeTherearetwotypesofloggingmodes:
• Cyclic (factorysetting): IftheinternalmemoryoftheDL2isfull,theoldestdatapacketswillbeoverwritten.
• Linear: IftheinternalmemoryoftheDL2isfull,nofurtherdatawill be logged.
12.1 Configuration: General Intheconfigurationwindow„General“carryoutthefollowingsettings:
• Enterusername
• Enterpassword
• Repeatpassword
• Enterdevicename(characterspermitted:letters,
numbers,underlinecharacter)
• Adjustlogginginterval(1...86400s;thesmallerthe
interval,themorecapacityisrequired)
• Adjustloggingmode
Usernameandpasswordarerequiredforthenextaccesstothewebinterface
© R
ESO
L 08
228
dl2.
mon
en.in
dd
11 |
12.4 Configuration: Firmware Update Intheconfigurationwindow„FirmwareUpdate“,carryoutthefollowingsettings:
• Enable/disableautomaticfirmwareupdate
• EnterupdateURL
• Adjustupdateinterval
12.6 About DL2 Inthiswindow,detailsaboutopensourceapplicationsandlibrariescoveredareshown.
12.5 Configuration: Remote access
• Enteroldremoteaccesspassword(factorysetting:vbus) • Enternewremoteaccesspassword • Confirmnewpassword
TheseadjustmentsarerequiredforaccessingthecontrollerviathedataloggerbymeansoftheServiceCenterSoftwareortheRESOLDataCenter.
13. Source code YoucanorderacopyofthecorrespondingsourcecodesandcompilationscriptsonDVDforahandlingandshippingfeeofEUR20,-from:
RESOL-ElektronischeRegelungenGmbHHeiskamstraße1045527HattingenGERMANY
Pleaseincludetheversionnumberofyourfirmwareinyourorder.(e.g.:„1.0(200805241128)“indicatedatthebottomofeverywebinterfacepage).Youmustnotspecifymorethanoneversionperorder.
© R
ESO
L 08
228
dl2.
mon
en.in
dd
| 12
Notes
Distributed by:
Please note:Thedesignandthespecificationsaretobechangedwithoutnotice.Theillustrationsmaydifferfromtheoriginal
Important notice:Wetookalotofcarewiththetextsanddrawingsofthismanualandtothebestofourknowledgeandconsent.Asfaultscanneverbeexcluded,pleasenote:Yourowncalcu-lationsandplans,underconsiderationofthecurrentstan-dards and DIN-directions should only be basis for yourprojects.Wedon´tofferaguaranteeforthecompletenessofthedrawingsandtextsofthismanual-theyonlyrepre-sentsomeexamples.Theycanonlybeusedatyourownrisk. No liability is assumed for incorrect, incomplete orfalseinformationand/ortheresultingdamages.
top related